Ael-2597-Mec-Cl-0305-R0 - Design Calculation of Heating Coil

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

STANDBY SRU & ADDITIONAL TANKS

IOCL - PARADIP REFINERY


DOCUMENT NUMBER: DESIGN CALCULATION OF HEATING COIL ARTSON
TANK 203-TK-012 (VGO-HDT FEED) 78200 ID X 15500 ENGINEERING
AEL-2597-MEC-CL-0305-R0 HT FIXED DOME ROOF LTD.

DESIGN CALCULATION OF HEATING COIL


(TANK SIZE: 78.2 M DIA X 15.5 M HT)
(TAG NO: 203-TK-012)

Revision and Authorization Record

0 15-01-2021 Issued for Review/Approval CPK CPK ACS

Rev Date Issued Issue Purpose Prepared By Checked By Approved By


TANK NO. 203-TK-012 (VGO-HDT FEED) 78200 ID X 15500 HT FIXED
DOME ROOF
DESIGN CALCULATION OF HEATING COIL

VGO HDT FEED STORAGE TANK (203-TK-012)

Heating Coil Installation = Horizontal (Tank bottom)

Product = VGO-HDT FEED

3
Tank Volume = 72000 m

Heat Load / Tank Heat losses, Q = 1631 KW (Ref Tank PDS, Doc no 080557C-203-PDS-2520-003)
5871600 KJ/h

2
Heating Medium = Steam @ 4 Kg/cm

Steam Temperature, Ts = 152 °C

Steam Latent Heat of Vaporization, λ = 2107 KJ/Kg

Steam Consumption (Qs) = ms x λ


ms = Qs / λ
Steam Consumption, ms = 2786.7 kg/h

Steam Density @ 4 Kg/cm2 = 2.669 kg/m3

Steam Volumetric Flow, qs = 1044.10 m3/hr


0.29 m3/sec

Max. allowable velocity of steam, v = 40 m/s

Steam Coil Size =Sqrt (qs / (v x 0.7854))

Pipe C/A Required = 0.007250715 m2

Pipe Size Required = 0.096082652 m 4 in

Outer Diameter of Pipe = 0.10229 m 102.29 mm

Heat Transfer Area, A = Q / U x (Ts - Tm)

Overall Heat Transfer Coefficient, U = 0.04 KW / m2 °C

Product Mean Temperature, Tm = 45.65 °C

Heat Transfer Area, A = 368.18 m2

Heat transfer area with 10% Margin = 405.0 m2


A = 3.14 x D x L
Coil Length, L = A / (3.14 x D)

Length of Coil, L = 1261 m

Result Summary:

Steam Coil Size = 4 in (To limit allowable steam velocity of 40 m/s)


Heat Transfer Area = 405 m2 (Arrived based on Heat load / tank heat losses provided)
Steam Coil Length = 1261 m