Miniature Power Relays: MY (S) Versatile Plug-In Relay
Miniature Power Relays: MY (S) Versatile Plug-In Relay
Miniature Power Relays: MY (S) Versatile Plug-In Relay
Refer to Connection Socket and Mounting Bracket Selection Table on page 25 in Options for information on the
possible combinations of Models with Plug-in Terminals and Sockets.
1
MY(S)
Contents
Model Number Structure............................................................................................. 1
Specifications
Coil Ratings ............................................................................................................ 2
MY2(S)/MY4(S)/MY4Z(S).............................................................................................. 3
Engineering Data ......................................................................................................... 6
Detailed Information on Models Certified for Safety Standards, MY2(S)/MY4(S)/MY4Z(S) ......... 8
Models Other Than MY(S) Models
MY2ZN ..................................................................................................................... 9
MY@F..................................................................................................................... 11
Detailed Information on Models Certified for Safety Standards, MY2ZN and MY@F.......... 14
MY4Z-CBG ............................................................................................................ 15
MYQ4 ..................................................................................................................... 17
MY2K ..................................................................................................................... 19
MY4(Z)H................................................................................................................. 21
Socket for MY............................................................................................................. 23
Options.................................................................................................................. 25
Safety Precautions .................................................................................................... 34
Specifications
Coil Ratings
MY(S)
Must Must
Coil inductance Max. Power
Rated current Coil operate release
Rated voltage (reference value) voltage consumption
resistance voltage voltage
(approx.)
50 Hz 60 Hz Arm. OFF Arm. ON % of rated voltage
6V 214.1 mA 183 mA 12.2 Ω 0.04 H 0.08 H
12 V 106.5 mA 91 mA 46 Ω 0.17 H 0.33 H
24 V 53.8 mA 46 mA 180 Ω 0.69 H 1.30 H Approx. 0.9 to
AC 30% min.
48/50 V 24.7/25.7 mA 21.1/22.0 mA 788 Ω 3.22 H 5.66 H 1.3 VA (60 Hz)
2
MY(S)
Specifications
Contact Ratings
DPDT 4PDT 4PDT (bifurcated)
Item Resistive load Inductive load Resistive load Inductive load Resistive load Inductive load
(cos φ = 1) (cos φ = 0.4, L/R = 7 ms) (cos φ = 1) (cos φ = 0.4, L/R = 7 ms) (cos φ = 1) (cos φ = 0.4, L/R = 7 ms)
5A, 250 VAC 2A, 250 VAC 3 A, 250 VAC 0.8 A, 250 VAC 3 A, 250 VAC 0.8 A, 250 VAC
Rated load
5A, 30 VDC 2 A, 30 VDC 3 A, 30 VDC 1.5 A, 30 VDC 3 A, 30 VDC 1.5 A, 30 VDC
Carry current 10 A (see note) 5 A (see note)
Max. switching 250 VAC
voltage 125 VDC
Max. switching
10 A 5A
current
Contact
Ag Au cladding + Ag alloy
materials
Failure rate
5 VDC, 1 mA 1 VDC, 1 mA 1 VDC, 100 μA
(reference value)
Note: Don’t exceed the carry current of a Socket in use. Please see page 23.
Characteristics
Item All Relays
Contact resistance 100 mΩ max. (50 mΩ: 4PDT bifurcated)
Operate time 20 ms max.
Release time 20 ms max.
Mechanical:18,000 operations/hr
Max. operating frequency
Electrical:1,800 operations/hr (under rated load)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1.0 min (1,000 VAC between contacts of same polarity)
Destruction:10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Vibration resistance
Malfunction:10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Destruction:1,000 m/s2
Shock resistance
Malfunction:200 m/s2
Endurance See the following table.
Ambient temperature Operating: –55 to 70°C (with no icing)
Ambient humidity Operating: 5 to 85% RH
Weight Approx. 35 g
Note: The values given above are initial values.
Endurance Characteristics
Electrical life
Contact form Mechanical life (at 18,000 operations/hr)
(at 1,800 operations/hr under rated load)
DPDT AC:50,000,000 operations min. 500,000 operations min.
4PDT DC:100,000,000 operations min. 200,000 operations min.
4PDT (bifurcated) 20,000,000 operations min. 100,000 operations min.
3
MY(S)
Dimensions (Unit: mm)
List of Models
MY2@@(S) Series
2.6
6.3
0.5
28 max.
5
Note: The picture is lockable test Terminal Arrangement/Internal Connections (Bottom View)
button type.
MY2IN(S) MY2IN(S) MY2IN-D2(S) MY2IN-CR
(AC Model) (DC Models) (DC Models Only) (AC Models Only)
1 4 1 4 1 4 1 4
5 8 5 8 5 8 5 8
9 12 9 12 9 12 9 12
− + − +
13 14 13 14 13 14 13 14
MY2IN1(S) MY2IN1-D2(S)
(DC Models) (DC Models Only)
1 4 1 4
5 8 5 8
9 12 9 12
+ − + −
13 14 13 14
Note: For the DC models, check the coil polarity when wiring and wire all connections correctly.
4
MY(S)
MY4@@(S) series
2.6
6.3
0.5
28 max.
5
Note: The picture is lockable test Terminal Arrangement/Internal Connections (Bottom View)
button type.
MY4(Z)IN(S) MY4(Z)IN(S) MY4(Z)IN-D2(S) MY4(Z)IN-CR(S)
(DC Models) (AC Models) (DC Models Only) (AC Models Only)
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8
9 10 11 12 9 10 11 12
− + − +
13 14 13 14 13 14 13 14
MY4(Z)IN1(S) MY4(Z)IN1-D2(S)
(DC Models) (DC Models Only)
1 2 3 4 1 2 3 4
5 6 7 8 5 6 7 8
+ − + −
13 14 13 14
Note: For the DC models, check the coil polarity when wiring and wire all connections correctly.
5
MY(S)
Engineering Data MY2(S)/ MY4(S)/MY4Z(S)
Maximum Switching Capacity Endurance Curve
MY2(S) MY2(S) MY2(S)
10,000 10,000
50 5,000 5,000
0.5 50 50
0.1 10 10
1 3 5 10 30 50 100 250 500 0 2 4 6 8 10 0 1 2 3 4 5
Contact voltage (V) Contact current (A) Contact current (A)
MY4(S) and MY4Z(S) MY4(S) MY4(S)
100 10,000 10,000
Number of operations (×103 operations)
50 5,000 5,000
250 VAC
30 3,000 3,000
resistive load
30 VDC
inductive load
10 AC resistive load AC inductive load 1,000 1,000
(cos φ = 0.4)
30 VDC 30 VDC
5 500 500
resistive load inductive load
3 300 300
30 VDC
DC resistive load resistive load 250 VAC
1 100 100 inductive load
250 VAC
0.5 50 50 250 VAC
resistive load
inductive load
0.3 DC inductive load 30 30
(L/R = 7)
0.1 10 10
1 3 5 10 30 50 100 250 500 0 1 2 3 4 5 0 0.5 1 1.5 2
Contact voltage (V) Contact current (A) Contact current (A)
MY4Z(S) MY4Z(S)
10,000 10,000
Number of operations (×103 operations)
5,000 5,000
3,000 3,000
100 100
30 VDC 250 VAC
resistive load inductive load
50 50
250 VAC
30 30
resistive load 250 VAC
inductive load
10 10
0 1 2 3 4 5 0 0.5 1 1.5 2
Contact current (A) Contact current (A)
250
550 600
Z 600 X'
400
Unit: m/s2
600
Y'
6
MY(S)
Engineering Data MY(S) (MY2ZN, MY@F)
Ambient Temperature vs. Ambient Temperature vs. Coil Temperature Rise
Must-operate and Must-release Voltage
MY2 AC Models MY2 AC Models, 50 Hz MY2 DC Models
100 Number of Relays: 10 120 120
Must-operate voltage
(average value) Must-release voltage 110 When rated voltage is applied 110 When rated voltage is applied
80 100 Operating temperature limit value 100 Operating temperature limit value
(E-class insulation, 120° C) (E-class insulation, 120° C)
90 90
80 80
60
70 70
30 No contact current 30
20
20 20 No contact current
10 10
0
−60 −30 0 30 60 90 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C)
MY2 DC Models MY4 AC Models, 50 Hz MY4 DC Models
100 120 120
Temperature rise (°C)
100 Operating temperature limit value 100 Operating temperature limit value
80 (E-class insulation, 120° C) (E-class insulation, 120° C)
90 90
80 80
60 70 70
60 60
3 A contact current × 4 circuits
40 50 50
3 A contact current × 4 circuits
40 1.5 A contact current × 4 circuits 40
1.5 A contact current × 4 circuits
30 No contact current 30
20
20 20 No contact current
10 10
0
−60 −30 0 30 60 90 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C)
Models with built-in diodes
MY4 AC Models The diode absorbs surge from the coil. This type is best suited for applications with semiconductor circuits.
With Diode Without Diode
100
Number of Relays: 10 Must-operate voltage
Must-operate/must-release voltage (%)
80
ON OFF ON OFF
60
40 140 V
24 VDC A
20 To digital
Di memory To digital
24 VDC
memory
A’ A’
0
−60 −30 0 30 60 90
Note: 1. Make sure that the polarity is correct.
Ambient temperature (°C)
2. The release time will increase, but the 20-ms specification for standard models is satisfied.
MY4 DC Models 3. Diode properties:The diode has a reversed dielectric strength of 1,000 V.
Forward current: 1 A
100
Number of Relays: 10
Models with Built-in CR Circuits
Must-operate voltage
Must-operate/must-release voltage (%)
80
With CR Without CR
60 282 V
282 V 2.5
msec
ms
40
80 V
20
4.12 ms
9.4 ms 600 V
A
0 A
−60 −30 0 30 60 90 C = 0.033 μF To digital
200 AC
Ambient temperature (°C) R = 6.8 kΩ 200 AC memory
scope
A’ A’
7
MY(S)
Detailed Information on Models Certified for Safety Standards, MY2(S)/MY4(S)/MY4Z(S)
VDE-certified Models (No. 112467UG, EN61810-1)
Model Coil ratings Contact form Contact ratings File No. Certified number of operations
6, 12, 24, 48/50, 100/ 10 A, 250 VAC (cos φ = 1)
110, 110/120, 200/ DPDT MY2: 10,000 operations
10 A, 30 VDC (L/R = 0 ms)
MY@ 220, and 220/240 VAC 6692 (VDE0435) MY4: 100,000 operations
6, 12, 24, 48, 100/ 5 A, 250 VAC (cos φ = 1) MY4Z: 50,000 operations (AC)
4PDT
110, and 125 VDC 5 A, 30 VDC (L/R = 0 ms)
8
MY(S)
Specifications
Contact Ratings
Load Inductive load Type Standard Model with built-in operation
Resistive load
Item (cos φ = 0.4, L/R = 7 ms) Item models indicator, diode, or CR circuit
5 A at 220 VAC 2 A at 220 VAC Ambient
Rated load
5 A at 24 VDC 2 A at 24 VDC operating −55 to 70° C −55 to 60° C*2
temperature*1
Rated carry current 5A
Ambient
Maximum contact voltage 250 VAC, 125 VDC
operating 5% to 85%
Maximum contact current 5A humidity
Contact form DPDT (Bifurcated) *1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.
Contact materials Au plating + Ag
Characteristics
Item MY2ZN series
Contact resistance*1 50 mΩ max.
Operation time*2 20 ms max.
Release time*2 20 ms max.
Maximum Mechanical 18,000 operations/h
operating
frequency Rated load 1,800 operations/h
9
MY(S)
Dimensions (Unit: mm)
MY2ZN, MY2ZN-D2
MY2ZN MY2ZN MY2ZN-D2
(AC Models) (DC Models) (DC Models Only)
2.6
0.5
28 max.
36 max. 6.4 (The coil has no polarity.) Check the coil polarity when wiring
21.5 max. and wire all connections correctly.
Check the coil polarity when wiring
* For the MY2Z-CR and MY2ZN-CR, and wire all connections correctly.
this dimension is 53 mm max.
Note: 1. An AC model has coil disconnection self-diagnosis.
2. For the DC models, check the coil polarity when wiring and wire all connections
correctly.
3. The indicator is red for AC and green for DC.
4. The operation indicator indicates the energization of the coil and does not
represent contact operation.
10
MY(S)
Specifications
Contact Ratings
Contact form DPDT 4PDT, 4PDT (Bifurcated)
Load Inductive load Inductive load
Resistive load Resistive load
Item (cos φ = 0.4, L/R = 7 ms) (cos φ = 0.4, L/R = 7 ms)
5 A at 220 VAC 2 A at 220 VAC 3 A at 220 VAC 0.8 A at 220 VAC
Rated load
5 A at 24 VDC 2 A at 24 VDC 3 A at 24 VDC 1.5 A at 24 VDC
Rated carry current 5A 3A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 5A 3A
Contact form DPDT 4PDT, 4PDT (Bifurcated)
Contact materials Ag Au plating + Ag
Type
MY@F
Item
*
Ambient operating temperature −55 to 70° C
Ambient operating humidity 5% to 85%
* With no icing or condensation.
Characteristics
Item Contact form DPDT 4PDT, 4PDT (Bifurcated)
Contact resistance*1 50 mΩ max.
Operation time*2 20 ms max.
Release time*2 20 ms max.
Maximum Mechanical 18,000 operations/h
operating
frequency Rated load 1,800 operations/h
*3
Insulation resistance 100 MΩ min.
Between coil and contacts
Between contacts of 2,000 VAC at 50/60 Hz for 1 min.
Dielectric
different polarity
strength
Between contacts of the
1,000 VAC at 50/60 Hz for 1 min.
same polarity
10 to 55 to 10 Hz, 0.5-mm single amplitude
Destruction
Vibration (1.0-mm double amplitude)
resistance 10 to 55 to 10 Hz, 0.5-mm single amplitude
Malfunction
(1.0-mm double amplitude)
Shock Destruction 1,000 m/s2
resistance Malfunction 200 m/s2
AC: 50,000,000 operations min.
Mechanical DC: 100,000,000 operations min.
(switching frequency: 18,000 operations/h)
Endurance
500,000 operations min. 200,000 operations min.
Electrical*4 (rated load, switching (rated load, switching
frequency: 1,800 operations/h) frequency: 1,800 operations/h)
11
MY(S)
Dimensions (Unit: mm)
Flange mounting
MY@F
2.6
Mounting Hole Dimensions
38 ±0.2
4.35
0.5
29 max. 38 44 max.
12
MY(S)
Engineering Data MY@F
Maximum Switching Capacity Endurance Curve
MY2F MY2F MY2F
10
0.1
10 10
5 10 50 100 500 0 1 2 3 4 5 6 7 0 1 2 3
Contact voltage (V) Contact current (A) Contact current (A)
MY4F and MY4ZF MY4F MY4F
AC resistive load
5
500 500
1 220 VAC resistive load 110 VAC inductive load (cos φ = 0.4)
100 100
0.5
DC resistive load 50 50
DC inductive load
(L/R = 7 ms) 30 VDC
220 VAC inductive load 30 VDC inductive load
resistive load
0.1 10 10 (cos φ = 0.4) (L/R = 7 ms)
500 500
100 100
110 VAC inductive load (cos φ = 0.4)
50 50
220 VAC resistive load
24 VDC inductive load (L/R = 7 ms)
10 10
24 VDC resistive load
220 VAC inductive load (cos φ = 0.4)
250
550 600
Z 600 X'
400
Unit: m/s2
600
Y'
13
MY(S)
Detailed Information on Models Certified for Safety Standards, MY2ZN and MY@F
• The standard models are certified for UL and CSA standards.
• The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use.
TÜV-certified Models (File No. R50030059) CSA-certified Models (File No. LR31928)
Coil Contact Certified number Coil Contact Certified number
Model Contact ratings Model Contact ratings
ratings form of operations ratings form of operations
6 to 125 DPDT 5 A, 250 VAC (cos φ = 1.0) 7A, 240 VAC (Resistive)
VDC 3 A, 120 VAC (cos φ = 1.0) 7A, 24 VDC (Resistive)
MY@ 10,000 operations
6 to 240 4PDT 0.8 A, 120 VAC (cos φ =
VDC 5A, 240 VAC (General Use) 6,000
0.4)
DPDT 5A, 250 VAC (Resistive)
UL-certified Models (File No. E41515)
5A, 30 VDC (Resistive)
Coil Contact Certified number
Model Contact ratings 1/6HP, 250 VAC
ratings form of operations 1,000
1/10HP, 120 VAC
7A, 240 VAC (General Use)
7A, 240 VAC (General Use)
7A, 24 VDC (Resistive) 6 to 240
(Same polarity)
VAC
5A, 240 VAC (General Use) MY@
6,000 6 to 125 7A, 24 VDC (Resistive)
5A, 250 VAC (Resistive) VDC (Same polarity)
5A, 30 VDC (Resistive) 5A, 240 VAC (General Use)
DPDT (Same polarity) 6,000
3A, 265 VAC (Resistive)
4PDT 5A, 30 VDC (Resistive)
1/6HP, 250 VAC
5A, 250 VAC (Resistive)
1/8HP, 265 VAC 1,000 (Same polarity)
1/10HP, 120 VAC 0.2A, 120 VDC (Resistive)
B300 Pilot Duty 6,000 1/6HP, 250 VAC
1,000
6 to 240 5A, 28 VDC (General Use) 1/10HP, 120 VAC
VAC (Same polarity)
MY@
6 to 125 5A, 240 VAC (General Use) • When ordering models that are certified for Lloyd’s Register (LR) Standards,
VDC (Same polarity) be sure to specify “LR-certified Model” with your order.
14
MY(S)
Specifications
Contact Ratings Characteristics
Load Inductive load Contact resistance*1 100 mΩ max.
Resistive load
Item (cos φ = 0.4, L/R = 7 ms) Operation time*2 20 ms max.
1 A at 220 VAC 0.3 A at 220 VAC Release time*2 20 ms max.
Rated load
1 A at 24 VDC 0.5 A at 24 VDC
Maximum Mechanical 18,000 operations/h
Rated carry operating
1A Electrical 1,800 operations/h
current frequency
Maximum contact Insulation resistance*3 100 MΩ
250 VAC, 125 VDC
voltage Between coil
Maximum contact and contacts
1A 2,000 VAC at 50/60 Hz for 1 min.
current Dielectric Between contacts
Contact form 4PDT (Crossbar bifurcated) strength of different polarity
Between contacts
Contact materials Au cladding + AgPd 700 VAC at 50/60 Hz for 1 min.
of the same polarity
10 to 55 to 10 Hz, 0.5-mm single amplitude
Destruction
Vibration (1.0-mm double amplitude)
resistance 10 to 55 to 10 Hz, 0.5-mm single amplitude
Malfunction
(1.0-mm double amplitude)
Shock Destruction 1,000 m/s2
resistance Malfunction 200 m/s2
5,000,000 operations min. (operating
Mechanical
frequency: 18,000 operations/hr)
Endurance
50,000 operations min. (switching
Electrical*4
frequency: 1,800 operations/h) at rated load
Failure rate P value (reference value)*5 100 μA at 1 VDC
Ambient operating temperature −25 to 70°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 35 g
Note: The above values are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied, not including
contact bounce.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for
dielectric strength measurement.
*4. Ambient temperature condition: 23° C
*5. This value was measured at a switching frequency of 120 operations per
minute.
Engineering Data
Maximum Switching Capacity Contact Reliability Test
(Modified Allen Bradley Circuit)
Contact load: 5 VDC, 1 mA resistive load
MY4Z-CBG Malfunction criteria level: Contact resistance of 100 Ω
10 30
Contact resistance (mΩ)
Contact current (A)
0.5
24
DC resistive load
15
MY(S)
Dimensions (Unit: mm)
MY4Z-CBG
Terminal Arrangement/Internal
2.6 Connections (Bottom View)
Standard Models
0.5
28 max.
6.3
Safety Precautions
Refer to the Common Relay Precautions.
Applicable Sockets
Use only combinations of OMRON Relays and Sockets.
16
MY(S)
Characteristics
Contact resistance*1 50 mΩ max.
Operation time *2
20 ms max.
Release time*2 20 ms max.
Maximum Mechanical 18,000 operations/h
operating
frequency Rated load 1,800 operations/h
Between coil and contacts 1,500 VAC at 50/60 Hz for 1 min.
Dielectric
strength
Between contacts of different polarity 1,500 VAC at 50/60 Hz for 1 min.
Between contacts of the same polarity 1,000 VAC at 50/60 Hz for 1 min. Note: The values at the left are initial
values.
Insulation resistance*3 100 MΩ min. *1. Measurement conditions: 1 A at 5
VDC using the voltage drop
Vibration Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) method
resistance Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) *2. Measurement conditions: With
rated operating power applied, not
Destruction 1,000 m/s2 including contact bounce.
Shock Ambient temperature condition:
resistance Malfunction 200 m/s2 23° C
*3. Measurement conditions: For 500
AC: 50,000,000 operations (5,000,000*4) min., DC: 100,000,000 operations VDC applied to the same location
Mechanical
(5,000,000*4) min. (switching frequency: 18,000 operations/h) as for dielectric strength
Endurance measurement.
200,000 operations min. (100,000 operations*4) (rated load, switching *4. This value is for bifurcated
Electrical*5
frequency: 1,800 operations/h) contacts.
*5. Ambient temperature condition:
Weight Approx. 35 g 23° C
Engineering Data
Maximum Switching Capacity Endurance Curve H2S Gas Data Malfunctioning Shock
MYQ4(Z) MYQ4 MYQ4 Y
10 1,000 80 Energized
Contact resistance (mΩ)
Number of operations (×104 operations)
550
Contact current (A)
17
MY(S)
Dimensions (Unit: mm)
2.6
21.5 max.
28 max. 28 max.
35.5 max. 21.5 max. Check the coil polarity when wiring (The coil has no polarity.)
and wire all connections correctly.
Note: 1. An AC model has coil disconnection self-
diagnosis.
2. For the DC models, check the coil polarity
when wiring and wire all connections
correctly.
Safety Precautions
• For models with built-in operation indicators, check the coil polarity when Relay Replacement
wiring and wire all connections correctly (DC operation).
• Use only combinations of OMRON Relays and Sockets. To replace the Relay, turn OFF the power supply to the load and Relay coil
sides to prevent unintended operation and possible electrical shock.
18
MY(S)
Specifications
Coil Rating
Set coil Reset coil Power consumption (VA, W)
Item Set voltage Reset Maximum
Rated current (mA) Coil Rated current (mA) Coil (V) voltage (V) voltage (V) Set coil Reset coil
Rated voltage (V) 50 Hz 60 Hz resistance (Ω) 50 Hz 60 Hz resistance (Ω)
12 57 56 72 39 38.2 130
Approx. 0.6 Approx. 0.2
AC 24 27.4 26.4 320 18.6 18.1 550 to 0.9 to 0.5
(at 60 Hz) (at 60 Hz)
100 7.1 6.9 5,400 3.5 3.4 3,000 110% max. of
80% max. 80% max.
12 110 110 50 235 rated voltage
DC 24 52 470 25 940 Approx. 1.3 Approx. 0.6
48 27 1,800 16 3,000
Note: 1. The rated current for AC is the value measured with a DC ammeter in half-wave rectification.
2. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for the AC rated current and ±15% for the
DC coil resistance.
3. The AC coil resistance is a reference value only.
4. Operating characteristics were measured at a coil temperature of 23°C.
5. The maximum voltage capacity was measured at an ambient temperature of 23°C.
19
MY(S)
Engineering Data
MY2K
Maximum Switching Capacity Endurance Curve
5 AC resistive load
500 500
AC inductive load
(cos φ = 0.4) 110 VAC resistive load
110 VAC inductive load
1 (cos φ = 0.4)
220 VAC resistive load 100
100
0.5 DC resistive load
50 50
DC inductive load
(L/R = 7 ms) 30 VDC resistive load 220 VAC 30 VDC inductive load
0.1 10 inductive load (L/R = 7 ms)
10
(cos φ = 0.4)
Percentage
change (%)
400 60
N = 20 90
40
300 Measurement: Shock was applied 2 20 Set voltage
400
times each in 6 directions along 3 80 60 40
80
350
axes with the Relay energized and not −20
40 60 80
Z’
1000
X’
1000 energized to check the shock values −40
Reset voltage
70
900 that cause the Relay to malfunction. −60
−80
1000 Unit: m/s2 Criteria: Non-energized: 200 m/s2 60
Y’
Energized: 200 m/s2 0 50 100 300 500 1,000 5,000 10,000
Uniform magnetic field strength (0e) Elapsed time (h)
For AC
2.6
0.5
28 max.
6.3
Note: R is a resistor for ampere-turn correction. This resistor is
0.5
21.5 max.
built-in to 50-VAC and higher models.
36 max. 6.4 (The coil has no polarity.)
Safety Precautions
• For applications that use a 200 VAC power supply, connect external resistors Rs and Rr to a 100 VAC Relay.
• Do not apply a voltage to the set and reset coils at the same time. If you apply the rated voltage to both coils 1 4
simultaneously, the Relay will be set.
5 8
• The minimum pulse width in the performance column is the value for the following measurement conditions: an ambient
temperature of 23° C with the rated operating voltage applied to the coil. The performance values given here may not be 9 10 11 12
satisfied due to use over time and a reduction in latching performance due to changes in the ambient temperature or in
the conditions of the application circuit. 13 14
For actual use, apply the rated operating voltage with a pulse width based on the actual load and reset the Relay at least Rr
once per year to prevent degradation over time.
• If the Relay is used in an environment with strong magnetic fields, the surrounding magnetic field can demagnetize the Rs Rs: 7.3 kΩ, 3 W min.
magnetic body and cause unintended operation. Therefore, do not use these Relays in environments with strong Set power supply
Rr: 14.3 kΩ, 1 W min.
magnetic fields. Reset power supply
Relay Replacement
To replace the Relay, turn OFF the power supply to the load and Relay coil sides to prevent unintended operation and possible electrical shock.
Applicable Sockets
Use only combinations of OMRON Relays and Sockets.
20
MY(S)
Specifications
Contact Ratings Characteristics
Load MY4H MY4ZH Contact resistance*1 50 mΩ max.
Inductive load Inductive load Operation time*2 20 ms max.
Resistive Resistive
Item cos φ = 0.4 cos φ = 0.4
load load Release time*2 20 ms max.
L/R = 7 ms L/R = 7 ms
3 A at 110 VAC 0.8 A at 110 VAC 3 A at 110 VAC 0.8 A at 110 VAC Maximum Mechanical 18,000 operations/h
Rated load operating
3 A at 24 VDC 1.5 A at 24 VDC 3 A at 24 VDC 1.5 A at 24 VDC Rated load 1,800 operations/h
frequency
Rated carry
3A Insulation resistance*4 100 MΩ min.
current
Maximum contact 125 VAC Between coil
voltage 125 VDC Dielectric and contacts 1,000 VAC at 50/60 Hz for 1 min.
Maximum contact strength Between contacts (700 VAC between contacts of the same polarity.)
3A of different polarity
current
Contact form 4DPDT 4DPDT (Bifurcated) 10 to 55 to 10 Hz, 0.5-mm single amplitude
Destruction
Vibration (1.0-mm double amplitude)
Contact materials Au plating + Ag
resistance 10 to 55 to 10 Hz, 0.5-mm single amplitude
Malfunction
Ambient operating (1.0-mm double amplitude)
temperature
−25 to 60° C*
Shock Destruction 1,000 m/s2
Ambient operating resistance Malfunction 200 m/s2
humidity
5% to 85%
50,000,000 operations (5,000,000 operations*4) min.
Mechanical
* With no icing or condensation. (operating frequency: 18,000 operations/h)
Endurance
100,000 operations (50,000 operations*4) min. rated
Electrical*5
load, switching frequency: 1,800 operations/h)
Failure rate P value Single contacts: 100 μA at 1 VDC
(reference value)*6 Bifurcated contacts: 100 μA at 100 mVDC
Weight Approx. 50 g
Note: The above values are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied, not including
contact bounce.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for
dielectric strength measurement.
*4. This value is for bifurcated contacts.
*5. Ambient temperature condition: 23° C
*6. This value was measured at a switching frequency of 120 operations per
minute.
Engineering Data
Maximum Switching Capacity Endurance Curve
MY4(Z)H MY4H
Number of operations (×104 operations)
Contact current (A)
AC resistive load
5
500
AC inductive load
110 VAC resistive load
(cos φ = 0.4)
0.5 50
DC resistive load
DC inductive load
(L/R = 7 ms)
0.1 10
110 VAC inductive load
(cos φ = 0.4) 24 VDC inductive load (L/R = 7 ms)
5 10 50 100 500 0 1 2 3
Contact voltage (V) Contact current (A)
Note: The durability of bifurcated contacts is one-half that of single contacts.
21
MY(S)
Dimensions (Unit: mm)
2.6
0.5
28.5 max.
(The coil has no polarity.)
35 max. 6.4
Safety Precautions
Applicable Sockets
Use only combinations of OMRON Relays and Sockets.
Application Environment for Hermetically Sealed
Relays
Humid environments can cause insulation problems, which may result in short-
circuiting or unintended operation.
Solution
Do not use these Relays in any environment where the Relay will come into
contact with water vapor, condensation, or water droplets. This can reduce the
surface tension of the insulating beads and cause short-circuiting or unintended
operation due to poor insulation.
Relay Replacement
To replace the Relay, turn OFF the power supply to the load and Relay coil
sides to prevent unintended operation and possible electrical shock.
22
MY(S)
Sockets for MY
DIN-rail-mounted (DIN-rail) Socket
Conforms to VDE 0106, Part 100
• Snap into position along continuous sections of any
mounting DIN-rail.
• Facilitates sheet metal design by standardized mounting
dimensions.
• Design with sufficient dielectric separation between
terminals eliminates the need of any insulating sheet.
Specifications
Terminal No. of Dielectric Insulation resistance
Mounting Appearance Model Carry current
type poles withstand voltage (see note 2)
2 PYF-08-PU 10 A
Push-In Plus
2,000 VAC, 1 min 1,000 MΩ min
terminals
4 PYF-14-PU 6A
PYFZ-08-E/
10 A 2,250 VAC, 1 min
PYFZ-08
PYF08A-E/
2 7A 1,000 MΩ min
PYF08A
DIN-rail-mounted
Socket Screw terminals
PYFZ-14-E/
6A 2,250 VAC, 1 min
PYFZ-14
PYF14A-E/
4 5A 1,000 MΩ min
PYF14A
PYF14-ESS-B
Rise-Up 2 and 4
12 A > 3 KV > 5 MΩ
terminals Common
PYF14-ESN-B
23
MY(S)
PY08/
2 7A 1000 MΩ min.
PY08-Y1
Solder terminals
PY14/
4 3A
PY14-Y1
PY08QN/
2 7A
PY08QN-Y1
Back-connecting 1,500 VAC, 1 min
Wrapping
terminals 100 MΩ min.
PY14QN/
4 3A
PY14QN-Y1
2 PY08-02 7A
Relays with
PCB terminals
4 PY14-02 3A
24
MY(S)
25
MY(S)
MY
80 82
70 (87) 66 (83) 67.5 63.1
61
42.5 28.1
27
PYF-@-PU (3.9)
PYFZ-@(-E)
PYF14-ESN-B PYF14-ESS-B
PYF@A-(@)
Back-mounting Sockets
Solder terminals/Wrapping terminals Relays with PCB Terminals
(PY@) (PY@-02)
39 (56) MY MY
48.2
PY@
PY@-02
26
MY(S)
PYF-08-PU 71.5
A1 A2
(13) (14)
Two M3 screw
67.5 holes or
30.8 two 3.5-dia. holes
28.1 108
(4.2) 25.6
12 42
(1) (4)
14 44
(5) (8)
90 35.3
11 41 Note 1: Pull out the hooks
(9) (12)
to mount the Socket
with screws.
27.35 Note: The numbers in
parentheses are Note 2: DIN-rail mounting is also
traditionally used possible. Refer to page 34
3.9 25.6
31 (4.2) terminal numbers. for supporting DIN-rails.
34.3
43
52.1
PYFZ-08-E +0.2
Two, 4.2 × 5 6−0.1 Two, M3, M4, or 4.5-dia. holes
mounting Eight, M3 × 8
holes
72 max. 35.4
(TOP VIEW)
4 Note: DIN-rail mounting is also
6 possible. Refer to page 34
23 max.
31 max. for supporting DIN-rails.
PYF08A-E +0.2
Two, 4.2 x 5 6−0.1
mounting Two, M3, M4, or 4.5-dia. holes
Eight, M3 x 8
holes
72 max.
(TOP VIEW)
Note: DIN-rail mounting is also
6 possible. Refer to page 34
23 max.
31 max. for supporting DIN-rails.
+0.2
6−0.1
PYF08A-N 42 12
Eight, M3×8 4 1
44 14
4 1 8 5
42 12
8 5
44 14 3.0 dia.
12 9
41
PYF-08A-N
11
73 41 11
12 9
14 14 13
A2 A2 A1
A2 A2 A1
Note: DIN-rail mounting is also
14 14 13
possible. Refer to page 34
Note: Figures in parentheses for supporting DIN-rails.
indicate DIN standard
22 max. 30 max. numbers.
27
MY(S)
Terminal arrangement/
Socket Dimensions Internal connections Mounting holes
(top view)
72 max. 35.4
4 (TOP VIEW)
6 Note: DIN-rail mounting is also
23 max.
possible. Refer to page 34
30 max.
for supporting DIN-rails.
72 max. 35.4
(TOP VIEW)
4 Note: DIN-rail mounting is also
possible. Refer to page 34
6 for supporting DIN-rails.
23 max.
30 max.
PYF-14-PU 71.5
A1 A2
(13) (14)
Two M3 screw
67.5 holes or
30.8 two 3.5-dia. holes
28.1 108
(4.2) 25.6
12 22 32 42
(1) (2) (3) (4)
14 24 34 44
90 (5) (6) (7) (8)
35.3
Note 1: Pull out the hooks
11 21 31 41
(9) (10) (11) (12)
to mount the Socket
with screws.
27.35
Note: The numbers in Note 2: DIN-rail mounting is also
parentheses are possible. Refer to page 34
3.9
31 (4.2) 25.6 traditionally used for supporting DIN-rails.
34.3 terminal numbers.
43
52.1
72 max. 35.4
(TOP VIEW)
4
Note: DIN-rail mounting is also
6 possible. Refer to page 34
29.5 max.
31 max. for supporting DIN-rails.
28
MY(S)
Terminal arrangement/
Socket Dimensions Internal connections Mounting holes
(top view)
PYF14A-E
+0.2
Two, 4.2 x 5 6−0.1
Two, M3, M4, or 4.5-dia. holes
mounting
holes Fourteen, M3 x 8
sems screws
72 max.
(TOP VIEW)
6 Note: DIN-rail mounting is also
29.5 max. possible. Refer to page 34
31 max.
for supporting DIN-rails.
PYF14A-N 42 32 22 12
6+0.2
−0.1 4 3 2 1
Fourteen, M3×8 44 34 24 14
8 7 6 5 Two, 4.5 dia. or M4
4 3 2 1
42 32 22 12
8 7 6 5
44 34 24 14
67 max.
26
PYF-14A-N 12 11 10 9
41 31 21 11
12 11 10 9 73 41 31 21 11
A2 A2 A1
14 14 13 Note: DIN-rail mounting is also
14 14 13
PYFZ-14
Two, M3, M4, or 4.5-dia. holes
Two, 4.2 × 5 6+0.2
–0.1
mounting holes
14-M3 × 8
72 max. 35.4
4 (TOP VIEW)
6 Note: DIN-rail mounting is also
29.5 max.
30 max. possible. Refer to page 34
for supporting DIN-rails.
72 max. 35.4
4 (TOP VIEW)
6 Note: DIN-rail mounting is also
29.5 max.
possible. Refer to page 34
16.5
30 max.
for supporting DIN-rails.
29
MY(S)
Terminal arrangement/
Socket Dimensions Internal connections (top view)/
mounting holes
PYF14-ESN-B
27 42.5
Label
27
9
NO
Relay
NC
4.45 4.45 4.45
82 75
3.2 4.1
6.3
PYC-35-B 6.4
COIL
COM.
24
22.5 Module
53
80
PYF14-ESS-B 27
61
9
COM.
NO
NC
4.45 4.45 4.45
83 3.2 75 4.1
6.3
PYC-35-B 6.4
COIL
29
22.5
55
82
30
MY(S)
Terminal arrangement/
Socket Dimensions Internal connections Mounting holes
(top view)
25.5 max.
29.5 max.
20 max. 24 max.
42 max.
PY08QN/
PY08QN-Y1
(See note) 29.5 max.
22 max.
41.5 max.
24 max.
42 max.
PY08-02
25.5 max.
29.5 max.
PY14/PY14-Y1
(See note) Fourteen, 3 x 1.2 elliptical holes
25.5 max.
29.5 max.
20 max. 24 max.
42 max.
PY14QN/
PY14QN-Y1
(See note)
29.5 max.
41.5 max.
42 max. 22 max.
24 max.
PY14-02
25.5 max.
29.5 max.
22 max.
16.5 max. Fourteen, 1.3-dia.
holes
Note: Use a panel with plate thickness of 1 to 2 mm for mounting the Sockets.
31
MY(S)
L
3.90 15.1 2 PYDN-7.75-020@
2.25 1.57
224.35
* Replace the box (@) in the model number with the specification code for the covering color. B: Black, S: Blue, R: Red
Note: When using short bar to coil terminals of PYF-@@-PU, make sure to use PYDN-31.0-080@ (31mm).
* Replace the box (@) in the model number with the specification code for the covering color. B: Black, Y: Yellow
22 40°
29 40°
* Replace the box (@) in the model number with the specification code for the covering color. B: Black, S: Blue, R: Red
32
MY(S)
Safety Precautions
Maximum Carry Current
• Do not allow the total current for all shorted contact form to exceed the maximum carry current of the Short Bar.
• Do not exceed the maximum carry current of the relay contacts for individual contact form.
• If you use more than one Socket, use End Plates (PFP-M).
Hold-down Clips
PYC-A1 PYC-E1 For sockets PYF14-ESN/-ESS
(2 pcs per set) (2 pcs per set)
Model Description
Metal spring clip (Used with
PYC-0
Relay only)
Plastic holding clip (Used with
36.3 36.3 PYC 35
Relay only)
PYC TR1 Thermoplastic writable label
Note: For total dimensions with plastic clip please
refer to drawings of the sockets.
4.5 5.75
4.25
4.5 1.2 4.5±0.1
28
29 max.
3.3
53
38.5 52 58.2
4.5
4.5 1.2
0
21.2 29 -0.1
PYCZ-C08 PYCZ-C14
72 max.
72 max.
34 max.
33 max. 29.5 max.
23 max.
33
MY(S)
72 elliptical holes
t=1.6
PYP-18
72 elliptical holes
35±0.3 27±0.15
1
15 25 25 25 25 15 (5)
10 10
1000 (500) *
PFP-100N2
16
4.5
35±0.3 27 24 29.2
15 25 25 25 10 25 15 1 1.5
10 1000
Spacer
End Plate
PFP-S
PFP-M
16
10
5 12
M4 x 8 pan head screw 6.2
1.8
1
34.8
50 35.5 35.3 44.3
1.8
11.5
10 1.3
16.5
M4 spring washer 4.8
34
MY(S)
Safety Precautions
Refer to the Common Relay Precautions.
Refer to Products Related to Common Sockets and DIN Tracks for precautions on the applicable Sockets.
Refer to PYF-@@-PU/P2RF-@@-PU for precautions on Push-In Plus Terminal Block Sockets.
Precautions for Correct Use
Handling
For models with a built-in operation indicator, models with a built-in diode, or
high-sensitivity models, check the coil polarity when wiring and wire all
connections correctly (DC operation).
Installation
• There is no specifically required installation orientation, but make sure that
the Relays are installed so that the contacts are not subjected to vibration or
shock in their movement direction.
• Use two M3 screws to attach Flange-mounted models (MY@F) and tighten the
screws securely (tightening torque: 0.98 N•m).
Latching Levers
• Turn OFF the power supply when operating the latching lever. After you use
the latching lever always return it to its original state.
• Do not use the latching lever as a switch.
• The latching lever can be used for 100 operations min.
Relay Replacement
To replace the Relay, turn OFF the power supply to the load and Relay coil
sides to prevent unintended operation and possible electrical shock.
35
OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • automation.omron.com
OMRON CANADA, INC. • HEAD OFFICE OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com São Paulo, SP, Brasil • 55 11 5171-8920 • automation.omron.com
J199I-E3-06 Note: Specifications are subject to change. © 2020 Omron. All Rights Reserved. Printed in U.S.A.