Sample Computation PDF
Sample Computation PDF
Volume Collected:
1000 𝑚𝐿 = 1 𝐿 = 0.001 𝑚3
Time to Collect:
𝑡 = 15.19 𝑠
𝑉 0.001𝑚3
𝑄𝑣 = = = 𝟔. 𝟓𝟖𝟑𝟐𝟕𝟖𝟒𝟕𝟑 × 𝟏𝟎−𝟓 𝒎𝟑 /𝒔
𝑡 15.19𝑠
Velocity, V:
𝑄𝑣 6.583278473×10−5 𝑚/𝑠
𝑉= = = 𝟎. 𝟏𝟑𝟒𝟑𝟓𝟐𝟔𝟐𝟏𝟗 𝒎/𝒔
𝐴 490×10−6 𝑚2
Dynamic Head:
𝑣2 0.1343526219 𝑚/𝑠
= = = 𝟔. 𝟖𝟒𝟕𝟕𝟑𝟖𝟏𝟏𝟗 × 𝟏𝟎−𝟑 𝒎
2𝑔 2(9.81 𝑚/𝑠 2 )
Total Head: