Refrigeration Research Receivers:

These receivers are hydrogen brazed for cleanliness and pressure tested
for reliability. A 430⁰ F fusible plug is installed on al receivers. All valves
are supplied with steel stem caps with copper gaskets and brass flare
nuts and caps.

VERTICAL MOUNT

Part # *Pump down Diameter & Inlet Outlet Wt.


capacity Length lbs.
Over end caps

5774 2 LB 3 X 10 ¼ SAE ¼ SAE VALVE 3

9028 2 LB 3 X 10 ¼ ID SWEAT ¼ ID SWEAT 2


VALVE
1920 2 LB 3½X7½ ¼ SAE ¼ SEA VALVE 2.9

1917 3 LB 3 ½ X 10 ¼ SAE ¼ SAE VALVE 3.5

9017 3 LB 3 ½ X 10 ¼ ID SWEAT ¼ ID SWEAT 3.5


VALVE
1921 4 LB 4 X 10 ¼ SAE ¼ SAE VALVE 4.5

9021 4 LB 4 X 10 ¼ ID SWEAT ¼ ID SWEAT 4.5


VALVE
1918 6 LB 5 X 10 ¼ SAE ¼ SAE VALVE 7.2

5315 6 LB 5 X 10 3/8 SAE 3/8 SAE VALVE 7.3

6848 6 LB 5 X 10 3/8 ID SWEAT 3/8 ID SWEAT 7.3


VALVE
1911 10 LB 6 X 12 3/8 SAE 3/8 SAE VALVE 10.9

6801 10 LB 6 X 12 3/8 ID SWEAT 3/8 ID SWEAT 10.9


VALVE
3212 16 LB 6 X 18 ½ SAE ½ SAE VALVE 15.6

9027 16 LB 6 X 18 ½ SAE SWEAT ½ ID SWEAT 15.6


VALVE

*90% AT 90⁰ FOR R 22, R 134A AND R502, - FOR R 12 MULTIPLY BY 1.1 – FOR R402b and R404 MULTIPLY BY .09
500psi Working Pressure
Refrigeration Research Oil Separators
Oil separators for either single or multiple (parallel)
Compressor systems. These oil separators contain
An internal mechanical float to provide the return
of oil to the crankcase of the compressor or the oil receiver.

Part # Nom. Diam Length Disc Oil Capacity in tons of Refrigeration 0°F
Tons Line Return R 12 R 22 R 502
8399 1 4 7 3/4 3/8 3/8 .9 1.3 1.3
8408 2 4 9 3/4 1/2 3/8 1.25 1.75 1.75
8409 4 4 14 5/8 3/8 3.5 5 5
8410 5 4 17 3/4 3/8 4.5 6 7
8411 8 6 12 7/8 3/8 7 9.5 10
8412 11 6 13 1/2 1 1/8 3/8 9 11.5 13
8413 14 6 15 1/2 1 3/8 3/8 10.5 13.5 17.5
8415 20 6 19 2 1/8 3/8 19.5 27.5 32.5

Refrigeration Research Accumulators


Air conditioning, heat pump, truck refrigeration
and many other applications require intermittent
operation of the refrigeration compressor. In
remote applications, the suction line may trap
or hold quantities of liquid which are suddenly
dumped into the compressor as it starts up.
Proper installation of the suction accumulator in
the suction line, just before the compressor, eliminates
damage. Liquid is temporarily held in the suction
accumulator and metered back to the compressor long
with any oil, at a controlled rate, through the metering device.

Vertical Mount Max. Ref. Holding Capacity lbs.


Part # Diam. Height Conn. Size R12 R134a R22 R404A
3701 4 6.63 5/8 2.4 2.2 2.9 1.9
3702 4 10.63 5/8 4.5 4.2 4.1 3.6
3703 4 10.63 3/4 5.2 4.5 4.1 3.7
3738 5 13.00 7/8 8.6 8.0 7.9 6.9
3700 6 15.00 1 1/8 14.2 13.1 12.9 11.4
3706 6 20.25 1 3/8 19.3 17.8 17.5 15.4

Heat Pump Accumulators


Vertical Mount
HP 3701 4 6 5/8 5/8 2.4 2.2 2.1 1.9
HP 3702 4 10 5/8 5/8 4.5 4.2 4.1 3.6
HP 3703 4 10 5/8 3/4 4.4 4.1 4
HP 3738 5 13 7/8 8.6 8.0 7.9 6.9
HP 3700 6 20 ¼ 1 3/8 14.2 13.1 12.9 11.4

Larger sizes are available