Landmark ™

Performance Marked by Flexibility

Commercial Packaged Rooftop Units


Standard- and High-Efficiency
2- to 25-Ton KG/KC/KH Models

Up to 13.0 SEER, 14.5 IEER


and 12.7 EER
Performance Marked by Flexibility™
When it comes to reliable and efficient performance, Landmark® rooftop units have always been a standout for light commercial
applications. Now we’ve built more flexibility into the line, making Landmark an excellent choice for virtually any application.

Configuration choices for greater


energy-savings potential
Landmark® rooftop The advantages of Landmark rooftop units lie
units at a glance: not only in its flexibility and simplicity, but also
in its efficiency. Landmark units are now
Engineered for installation
available in standard- and high-efficiency models,
flexibility, energy-efficient performance
and easy serviceability and with the addition of the optional MSAV®
supply fan, are up to 27% more efficient.* For
2- to 25-ton gas/electric and additional savings, high-efficiency models
electric/electric units; qualify for many state and local utility rebates.
2- to 20-ton heat pump units

Standard- and high-efficiency Over 30 features designed to reduce


units available installation and service time
Building automation integration
More than 100 field-selectable Landmark rooftop units have been designed
improves efficiency and comfort
options to ensure fast and so that installation and service time are
easy installation reduced. An isolated compressor compartment All Landmark units can now be integrated
means easier, more accurate charge with the industry's leading building automation
Optional MSAV® supply fan confirmation. The slide-out blower makes system protocol using the BACnet option.
technology with variable frequency
cleaning the blower wheel and belt tensioning, BACnet allows remote monitoring and
drive that delivers fan power savings
of up to 61% adjustment or replacement quicker and easier. adjusting of the building's heating, cooling
And the accessible gas compartment allows and humidity levels; as well as control of the
Available through select Lennox easy access to all gas components, making rest of the building's systems, like signs,
PartsPlus™ stores and Lennox analysis and service quicker. lighting, refrigeration and more.
commercial warehouses

Readily available for


your specific light
EFFICIENCY RATING commercial application
Up to 13.0 SEER, 14.5 IEER Every Lennox commercial distribution
and 12.7 EER facility has Landmark units ready for
WARRANTIES immediate shipment, thanks to daily
restocking. In many major markets, units
15-Year Limited Warranty
can be picked up the same day they’re
on stainless steel gas heat exchanger
ordered, and units are available within
10-Year Limited Warranty
48 hours or less to 98% of North America.
on aluminized gas heat exchanger
5-Year Limited Warranty
on compressor
3-Year Limited Warranty
on Environ™ Coil System Call 1-877-792-0024 to get quotes within minutes,
1-Year Limited Warranty and to check availability in your area.
on covered components
See warranty certificate for actual details. *Part load, IEER improvement. Comparing standard 10.9 Ieer system to optional MSAV 13.8 IEER system.
Field-installed options allow
extensive customization

Landmark is ready to conform to your application


Landmark units are available in 2- to 25-ton gas/electric and electric/electric and 2- to 20-ton heat pump configurations. With
more than 100 field-installed options available, installers can have exactly the right solution for their needs at the job site, and
customers can get the unit that fits their application perfectly.

Field-installed accessories for fast • LPG Conversion Kit (Gas/Electric only) Factory options or
replacement • -40°F cold weather kit (Gas/Electric only)
field accessories
Landmark® units include convenient For maximum time and cost flexibility,
• Combustion air intake and flue exhaust
­features like plug connections for wiring, choose to have these options installed in
extensions (Gas/Electric only)
panel knock-outs and pre-installed accessory the field or at the factory.
framing. You can choose a stock unit and • Blower proving switch
• Economizers
quickly install accessories for those • Dirty filter switch
fast-track replacement jobs. • Barometric relief dampers
• Manual outdoor air dampers (25%)
• Field-powered GFI • High- and low-static drive kits
• Motorized outdoor air dampers
• Disconnects • Heaters (electric/electric only)

• Economizers with single or dual • BACnet module


enthalpy control Factory-installed options
• Novar 2051 ETM module
for fast installation
• Electric heat
For quick, built-to-order solutions,
• 50% constant-volume power exhaust fan
Landmark units can be built and tested
• CO2 sensor at the factory to exact specifications in
weeks with these options:
• Return and supply air smoke detectors
• MSAV® (Multi-Stage Air Volume) supply
• Low ambient kits
fan option
• Hail guards
• Coil corrosion protection
• Coil guards
• Stainless steel heat exchanger
• Link to the L Connection® Network line of
• Hinged doors
commercial controls with an optional
Network Thermostat Controller
Landmark®
Environ™ Coil System: Uses up to 52% less refrigerant, is
1 
up to 59% lighter and has up to 20% fewer brazed joints
than typical units (standard on all 7.5- to 25-ton G/E
and E/E models; heat pump models use tube and fin coils). 4 8
2 Scroll Compressor: Standard on all units for reliable
5
long-term operation.
High-Pressure Switch: Improves reliability by safeguarding
3  1
compressor from extreme operating conditions. 9 3
12 2
Slide-Out Blower: Reduces time needed to adjust fan
4  6
11
speed, belt tensioning or blower cleaning. 7
5 Predefined Supply Fan Motor/Drive Combinations: 10
Make selecting components to meet static and airflow
requirements quick and easy.
Easy-Access Gas Compartment: Allows access to all
6 
gas components. Fork Slots on Three Sides: Easy to pick up and transport
•• 
units from almost any angle.
7 Corrosion-Resistant, Removable Drain Pan: Provides
application flexibility, durability and improved Full-Perimeter Base Rail (with Rigging Holes): Provides
•• 
serviceability. Bottom drain capability also standard. greater structural integrity, so the unit is easier to handle
when rigging and transporting.
8 Independent Motor Mount: Allows for easy and efficient
service access without removing the top panel. Hinged Access Panels: Factory option provides quick
12 
access to components and protects panels and roof from
9 Isolated Compressor Compartment: Allows performance
damage during servicing.
check during normal compressor operation without
disrupting airflow.

Landmark® high-efficiency rooftop unit performance specifications


Cooling Data Heating Input Physical data
NOM. DIMENSIONS SHIP WT.
TON MODEL EER IEER LOW STD. MED. HIGH H X W X L [INCHES] [LBS.]
7.5 KGA092H4B/M 12.5 13.0/14.0 — 130 180 240 47 x 61 x 102 1,154
8.5 KGA102H4B/M 12.2 12.9/14.0 — 130 180 240 47 x 61 x 102 1,174
10 KGA120H4B/M 12.0 13.0/13.8 — 130 180 240 47 x 61 x 102 1,222
Gas/ 13 KGA156H4B/M 12.0 13.6/14.1 — 260 360 — 55 x 91 x 108 2,135
Electric
15 KGA180H4B/M 12.0 13.5/13.7 — 260 360 480 55 x 91 x 133 2,315
Units
17.5 KGA210H4B/M 12.0 13.0/14.0 — 260 360 480 55 x 91 x 133 2,440
20 KGA240H4B/M 12.0 13.2/14.5 — 260 360 480 55 x 91 x 133 2,525
25 KGA300H4B/M 10.5 10.9/13.8 — 260 360 480 55 x 91 x 133 2,630
KW Range
7.5 KCA092H4B/M 12.7 13.0/14.0 7.5 15.0 22.5 30.0 45.0 47 x 61 x 102 1,112
8.5 KCA102H4B/M 12.4 12.9/14.0 7.5 15.0 22.5 30.0 45.0 47 x 61 x 102 1,132
10 KCA120H4B/M 12.2 13.2/14.0 15.0 22.5 30.0 45.0 60.0 47 x 61 x 102 1,187
ELECTRIC/ 13 KCA156H4B/M 12.0 13.6/14.1 15.0 30.0 45.0 60.0 — 55 x 91 x 108 1,985
Electric
15 KCA180H4B/M 12.0 13.5/13.7 15.0 30.0 45.0 60.0 — 55 x 91 x 133 2,165
Units
17.5 KCA210H4B/M 12.0 13.0/14.0 15.0 30.0 45.0 60.0 90.0 55 x 91 x 133 2,290
20 KCA240H4B/M 12.0 13.2/14.5 15.0 30.0 45.0 60.0 90.0 55 x 91 x 133 2,375
25 KCA300H4B/M 10.5 10.9/13.8 15.0 30.0 45.0 60.0 90.0 55 x 91 x 133 2,480
Landmark® standard-efficiency rooftop unit
performance specifications

Cooling Data Heating Input Physical data


NOM SEER OR DIMENSIONS SHIP WT.
TON. MODEL EER IEER LOW STD. MED. HIGH H X W X L [INCHES] [LBS.]
2 KGA024S4D 11.4 13.0 — 65 — — 39 x 47 x 86 591
2.5 KGA030S4D 11.2 13.0 — 65 — — 39 x 47 x 86 593
3 KGA036S4B 10.7 13.0 — 65 105 — 39 x 47 x 86 594
Gas/Electric Units

4 KGA048S4B 11.0 13.0 — 65 105 150 39 x 47 x 86 631


5 KGA060S4B 11.2 13.0 — 65 105 150 39 x 47 x 86 661
6 KGA072S4B 11.0 11.2 — 65 105 150 47 x 47 x 86 760
7.5 KGA090S4B 11.0 11.2 — — 105 150 47 x 47 x 99 865
7.5 KGA092S4B/M 11.0 11.8/13.0 — 130 180 240 47 x 61 x 102 1,052
8.5 KGA102S4B/M 11.0 11.8/13.0 — 130 180 240 47 x 61 x 102 1,072
10 KGA120S4B/M 11.0 11.8/13.0 — 130 180 240 47 x 61 x 102 1,112
12.5 KGA150S4B/M 11.0 11.4/12.0 — 130 180 240 47 x 61 x 102 1,202
15 KGA180S4B/M 10.8 11.0/12.6 — 260 360 480 55 x 92 x 108 1,990
17.5 KGA210S4B/M 10.8 12.0/13.1 — 260 360 480 55 x 92 x 108 2,135
20 KGA240S4B/M 10.8 11.0/13.0 — 260 360 480 55 x 92 x 133 2,380
25 KGA300S4B/M 10.0 10.0/12.0 — 260 360 480 55 x 92 x 133 2,380
KW Range*
2 KCA024S4D 11.4 13.0 7.5 10.0 — — — 39 x 47 x 86 555
2.5 KCA030S4D 11.2 13.0 7.5 10.0 — — — 39 x 47 x 86 557
electric/electric units

3 KCA036S4B 10.7 13.0 7.5 15.0 — — — 39 x 47 x 86 558


4 KCA048S4B 11.0 13.0 7.5 15.0 — — — 39 x 47 x 86 595
5 KCA060S4B 11.2 13.0 7.5 15.0 22.5 — — 39 x 47 x 86 625
6 KCA072S4B 11.2 11.4 7.5 15.0 22.5 30.0 — 47 x 47 x 86 724
7.5 KCA090S4B 11.2 11.4 7.5 15.0 22.5 30.0 — 47 x 47 x 99 827
7.5 KCA092S4B/M 11.2 12.0/13.2 7.5 15.0 22.5 30.0 45.0 47 x 61 x 102 1,052
8.5 KCA102S4B/M 11.2 12.0/13.2 7.5 15.0 22.5 30.0 45.0 47 x 61 x 102 1,072
10 KCA120S4B/M 11.2 12.0/13.2 15.0 22.5 30.0 45.0 60.0 47 x 61 x 102 1,112
12.5 KCA150S4B/M 11.2 11.6/12.2 15.0 23.0 30.0 45.0 60.0 47 x 61 x 102 1,202
15 KCA180S4B/M 11.0 11.2/12.8 15.0 30.0 45.0 60.0 — 55 x 92 x 108 1,840
17.5 KCA210S4B/M 11.0 12.2/13.3 15.0 30.0 45.0 60.0 90.0 55 x 92 x 108 1,985
20 KCA240S4B/M 11.0 11.2/13.2 15.0 30.0 45.0 60.0 90.0 55 x 92 x 133 2,230
25 KCA300S4B/M 10.1 10.1/12.1 15.0 30.0 45.0 60.0 90.0 55 x 92 x 133 2,230
47 Cap. HSPF/COP 47 17 Cap. COP 17
2 KHA024S4D 11.2 13.0 24,000 7.7/3.4 14,400 2.3 39 x 47 x 86 591
2.5 KHA030S4D 11.3 13.0 29,200 7.7/3.5 17,600 2.3 39 x 47 x 86 593
3 KHA036S4B 10.9 13.0 36,400 7.7/3.6 22,000 2.3 39 x 47 x 86 595
4 KHA048S4B 10.7 13.0 48,000 7.7/3.5 29,500 2.4 39 x 47 x 86 617
Heat Pumps

5 KHA060S4B 10.9 13.0 60,500 7.7/3.6 36,000 2.4 47 x 47 x 86 727


6 KHA072S4B 11.0 11.2 70,000 3.3 40,000 2.25 47 x 47 x 99 810
7.5 KHA092S4B/M 11.0 12.2/12.5 89,000 3.3 53,000 2.25 47 x 61 x 102 1,137
8.5 KHA102S4B/M 11.0 12.2/12.5 100,000 3.3 55,000 2.25 47 x 61 x 102 1,169
10 KHA120S4B/M 11.0 11.3/12.5 116,000 3.3 72,000 2.25 47 x 61 x 102 1,235
12.5 KHA150S4B/M 10.6 10.7/12.0 138,000 3.3 82,000 2.05 47 x 61 x 124 1,435
15 KHA180S4B/M 10.6 12.2/13.2 178,000 3.2 104,000 2.05 55 x 92 x 130 2,150
20 KHA240S4B/M 10.6 11.2/13.0 220,000 3.2 128,000 2.05 55 x 92 x 130 2,350

Certified in accordance with the USE certification program which is based on ARI Standard 210/240: 95ºF outdoor air temperature and 80ºF dB/67ºF wb entering evaporator coil air.
Certified in accordance with the ULE certification program which is based on ARI standard 340/360: 95°F outdoor air temperature and 80°F dB/67°F wb entering evaporator air;
minimum external duct static pressure.
Direct-drive blower motors available for 2- to 5-ton models.
  *Nominal electric heat capacities are rated at 240V, 480V and 600V.
**Heating CFM for gas models varies dependent upon heat option selected. Minimum heating CFM for heat pumps does not include supplemental electric heat.
Note: Due to Lennox’ ongoing commitment to quality, all specifications, ratings and dimensions are subject to change.
Solutions for customized comfort
Don’t just choose a Lennox® product—choose a Lennox Commercial Comfort System.
These complete packages of HVAC solutions provide tools to create a healthy and comfortable environment.

Packaged Units Commercial Controls

• Energence® Rooftop Units • Systems Integration Solutions


• Strategos Rooftop Units
®
• Commercial Thermostats
• Landmark Rooftop Units
®
• L Connection® Network
• Raider™ Rooftop Units

Solar Ready Indoor Air Quality

• SunSource® Commercial • Humiditrol® Dehumidification System


Energy System • Demand Control Ventilation
• Air Filters
• UVC Lamps

Split Systems Heating

• S-Class® Air Conditioners/Heat Pumps • Unit Heaters


• T-Class Air Conditioners/Heat Pumps
™ • Duct Furnaces
• Air Handlers • Furnaces
• Indoor Coils

Visit us at www.lennox.com, or contact us at 1-877-726-0024. Litho U.S.A.

© 2013 Lennox Industries Inc.


For a complete list of the registered and common law trademarks owned
by Lennox Industries Inc., please visit www.lennox.com. 36W72 05/13 PC74739

You might also like