Fuel Cell System

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

UTILIZING AN EXTEMPORE ELECTROLYZER—FUEL CELL SYSTEM

INTRODUCTION
ELECTROLYSIS
Water electrolysis is a process wherein Time Volume
Amperes Volts n​e
(minutes) (mL/H​2​)
an oxidation-reduction of water that occurs
0 0.186 0.57 0 0
when electrical energy is applied, and the 0.15867
water disassociates into oxygen and hydrogen 2 0.162 0.50 2
7
gas. In this process, a reduction reaction occurs 4 0.147 0.45 4 0.19429
at the cathode to generate hydrogen, and an 8
oxidation reaction occurs at the anode to 6 0.137 0.42 6 0.22337
2
generate oxygen.
8 0.131 0.40 8 0.24528
3
Fuel cells produce electricity by 0.16432
Average 0.1526 0.468
combining oxygen and hydrogen through a 6
chemical reaction, and continue as long as fuel Table 1: Data table for recorded data during electrolysis.
is sufficient.
FUEL CELL
Time Volume
In this activity, the researchers will Amperes Volts n​fc
(minutes) (mL/H​2​)
attempt making an electrolyzer-fuel cell system 0 0.196 0.66 8 0
wherein voltage will be produced via the 2 0.195 0.68 5 4.126714
conversion of energy from heat to electricity. 4 0.194 0.67 2 20.22588
The overall efficiency of the system will also be 5:20 0.190 0.46 0 3.022246
7 0 0 0 0
determined in hopes of further understanding Average 0.155 0.494 5.474968
its effectiveness. Table 2: Data table for recorded data during electric energy
production of fuel cell from produced H2 and O2 in preceding
METHODOLOGY water electrolysis.

For the first part of the experiment n​e n​fc


(water electrolysis), solar panels were wired to 0.164326 5.474968
water fuel cell, the cell having both of its
chambers filled with water. The fuel cell is then n​over-all 0.899680613
wired to a transformer, which will show the Table 3: Overall efficiency.
voltage and ampere readings as well as
facilitate the flow of electricity. The panels are The researchers computed for the
subjected to light, and electrolysis will take efficiency of the electrolysis and the fuel-cell
place. Important data such as electric current, system using the gathered data and used the
voltage, and volume will be recorded by the
averages to determine the overall efficiency of
researchers with an interval of two minutes
until the volume of produces Hydrogen gas is at the system.
8mL. It is

The next part of the experiment CONCLUSION AND RECOMMENDATIONS


(fuel-cell electricity production) will require
the same used fuel cell—now fueled with Results may be affected by slight delays
hydrogen and oxygen gas—to be wired to the in tallying the data, hence the intervals not
transformer. Important data such as electric being very exact. This may cause it to be
current, voltage, and volume will be recorded slightly inaccurate.
by the researchers with an interval of two
minutes until the volt and ampere readings REFERENCES
reach 0.

Data interpretation and computations


will follow.

RESULTS AND DISCUSSION