DESIGN CALCULATIONS
PMD/ENGINEERING/DESIGN SERVICES/CIVIL-STRUCTURAL
LATERAL EARTH PRESSURE
Height of soil layer, H 7 m
Depth of water table, Hw = 3 m
Dead Load on Top, PD = 0 kPa
Live Load on Top, PL = 12 kPa
SOIL DATA
γmoist = 18.36 kN/m3
ω= 16.74 %
Gs = 2.54
φ= 27 deg
γw = 9.81 kN/m3
γdry = γmoist/(1+ω) = 15.727 kN/m3
γsat = (Gs + Gsω)γw/(1+Gsω) = 20.410 kN/m3
Ko = 1-sinθ = 0.546
Ka = (1-sinθ)/(1+sinθ) = 0.376
Kp = (1+sinθ)/(1-sinθ) = 2.663
SEISMIC PARAMETERS
amax = 0.40 g *peak ground acceleration
SURCHARGE
qD = PD = 0 kPa
qD+L = PD + PL = 12.0 kPa
SOIL PRESSURES
At-rest Condition
Po1 = KoγmoistHw = 30.07 kPa
Po2 = Po1+Ko(γsat-γw)(H-Hw) = 53.23 kPa
Psur = KoqD = 0.00 kPa
Pw = γw(H-Hw) = 39.24 kPa
Active Condition
Pa1 = KaγmoistHw = 20.68 kPa
Pa2 = Pa1+Ka(γsat-γw)(H-Hw) = 46.00 kPa
Psur = KaqD+L = 4.51 kPa
Pw = γw(H-Hw) = 39.24 kPa
PSEUDOSTATIC EARTHQUAKE LOAD (using Seed & Whitman Method)
PE = (3/8)(amax/g)H2γmoist = 134.946 kN
P1 = (2/5)(PE/H) = 7.71 kPa
P2 = (8/5)(PE/H) = 30.84 kPa
QESH-SP –IMS-06F1 MAYNILAD WATER SERVICES, INC.
Revision: 0 MWSS COMPLEX, KATIPUNAN AVE., BALARA, QUEZON CITY, 1105
Page 1 of 1 TEL. NO. +632 981 3433