0% found this document useful (0 votes)
170 views1 page

Lateral Earth Pressure

1. This document provides design calculations for lateral earth pressure on a retaining wall including soil properties, groundwater conditions, surcharge loads, and seismic parameters. 2. Key parameters determined include earth pressures under at-rest and active soil conditions, as well as a pseudostatic earthquake load using the Seed & Whitman method. 3. Soil properties, groundwater table, surcharge loads, and a peak ground acceleration are used to calculate lateral earth pressures and seismic loads on the retaining wall.

Uploaded by

Kramyer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
170 views1 page

Lateral Earth Pressure

1. This document provides design calculations for lateral earth pressure on a retaining wall including soil properties, groundwater conditions, surcharge loads, and seismic parameters. 2. Key parameters determined include earth pressures under at-rest and active soil conditions, as well as a pseudostatic earthquake load using the Seed & Whitman method. 3. Soil properties, groundwater table, surcharge loads, and a peak ground acceleration are used to calculate lateral earth pressures and seismic loads on the retaining wall.

Uploaded by

Kramyer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

DESIGN CALCULATIONS

PMD/ENGINEERING/DESIGN SERVICES/CIVIL-STRUCTURAL

LATERAL EARTH PRESSURE

Height of soil layer, H 7 m


Depth of water table, Hw = 3 m
Dead Load on Top, PD = 0 kPa
Live Load on Top, PL = 12 kPa

SOIL DATA

γmoist = 18.36 kN/m3


ω= 16.74 %
Gs = 2.54
φ= 27 deg
γw = 9.81 kN/m3

γdry = γmoist/(1+ω) = 15.727 kN/m3


γsat = (Gs + Gsω)γw/(1+Gsω) = 20.410 kN/m3
Ko = 1-sinθ = 0.546
Ka = (1-sinθ)/(1+sinθ) = 0.376
Kp = (1+sinθ)/(1-sinθ) = 2.663

SEISMIC PARAMETERS

amax = 0.40 g *peak ground acceleration

SURCHARGE

qD = PD = 0 kPa
qD+L = PD + PL = 12.0 kPa

SOIL PRESSURES

At-rest Condition
Po1 = KoγmoistHw = 30.07 kPa
Po2 = Po1+Ko(γsat-γw)(H-Hw) = 53.23 kPa
Psur = KoqD = 0.00 kPa
Pw = γw(H-Hw) = 39.24 kPa

Active Condition
Pa1 = KaγmoistHw = 20.68 kPa
Pa2 = Pa1+Ka(γsat-γw)(H-Hw) = 46.00 kPa
Psur = KaqD+L = 4.51 kPa
Pw = γw(H-Hw) = 39.24 kPa

PSEUDOSTATIC EARTHQUAKE LOAD (using Seed & Whitman Method)

PE = (3/8)(amax/g)H2γmoist = 134.946 kN
P1 = (2/5)(PE/H) = 7.71 kPa
P2 = (8/5)(PE/H) = 30.84 kPa

QESH-SP –IMS-06F1 MAYNILAD WATER SERVICES, INC.


Revision: 0 MWSS COMPLEX, KATIPUNAN AVE., BALARA, QUEZON CITY, 1105
Page 1 of 1 TEL. NO. +632 981 3433