This product data sheet provides information on the KT5W-2N1116 contrast sensor. It has a sensing distance of 10 mm, LED light source, 1.2 x 4.2 mm light spot, vertical light emission, static 2-point teach-in mode, 10-30V DC power supply, and IP67 enclosure rating. Key specifications include a response time of 50 microseconds and switching frequency of 10 kHz.

Uploaded by

Abu Naeem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
102 views8 pages

Datasheet KT5W-2N1116 1018045 en

This product data sheet provides information on the KT5W-2N1116 contrast sensor. It has a sensing distance of 10 mm, LED light source, 1.2 x 4.2 mm light spot, vertical light emission, static 2-point teach-in mode, 10-30V DC power supply, and IP67 enclosure rating. Key specifications include a response time of 50 microseconds and switching frequency of 10 kHz.

Uploaded by

Abu Naeem
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Product data sheet

KT5W-2N1116
KT5

CONTRAST SENSORS
KT5W-2N1116 | KT5
CONTRAST SENSORS

A Ordering information

Type Part no.

B KT5W-2N1116 1018045

C Other models and accessories www.sick.com/KT5

D
E
F
Detailed technical data
Features

H
Dimensions (W x H x D) 30.4 mm x 53 mm x 80 mm

Sensing distance 10 mm 1)


Housing design (light emission) Rectangular

I Light source LED, RGB 2)


Wave length 470 nm, 525 nm, 640 nm

J Light emission
Light spot size
Long and short side of housing, exchangeable

1.2 mm x 4.2 mm

K Light spot direction

Adjustment
Vertical 3)
Teach-in button

L Teach-in mode

1)
 From front edge of lens.
Static 2-point teach-in

M
2)
 Average service life: 100,000 h at TU = +25 °C.
3)
 In relation to long side of housing.

Mechanics/electronics
N Supply voltage 10 V DC ... 30 V DC 1)
Ripple ≤ 5 Vpp 2)

O Power consumption < 80 mA 3)


Switching frequency 10 kHz 4)

P Response time 50 µs 5)

Q
1)
 Limit values when operated in short-circuit protected network: max. 8 A.
2)
 May not exceed or fall below Uv tolerances.
3)
 Without load.

R
4)
 With light/dark ratio 1:1.
5)
 Signal transit time with resistive load.
6)
 Short-circuit-proof.
7)
 Reference voltage DC 50 V.

S
T 2 REGISTRATION SENSORS | SICK Product data sheet | 2020-03-11 11:43:34
Subject to change without notice
KT5W-2N1116 | KT5
CONTRAST SENSORS

Switching output NPN

Switching output (voltage) NPN: HIGH = approx. VS / LOW ≤ 2 V

Output current Imax. 100 mA 6)


Input, teach-in (ET) NPN
Teach: U < 2 V
Run: U = 10 V ... < UV

Retention time (ET) 25 ms, non-volatile memory

Connection type Male connector M12, 5-pin

Protection class II 7)


Circuit protection UV connections, reverse polarity protected
Output Q short-circuit protected
Interference pulse suppression
Enclosure rating IP67

Weight 400 g

Housing material Metal, Zinc diecast

1)
 Limit values when operated in short-circuit protected network: max. 8 A.
2)
 May not exceed or fall below Uv tolerances.
3)
 Without load.
4)
 With light/dark ratio 1:1.
5)
 Signal transit time with resistive load.
6)
 Short-circuit-proof.
7)
 Reference voltage DC 50 V.

Ambient data
Ambient operating temperature –10 °C ... +55 °C

Ambient storage temperature –25 °C ... +75 °C

Shock load According to IEC 60068

Classifications
ECl@ss 5.0 27270906

ECl@ss 5.1.4 27270906

ECl@ss 6.0 27270906

ECl@ss 6.2 27270906

ECl@ss 7.0 27270906

ECl@ss 8.0 27270906

ECl@ss 8.1 27270906

ECl@ss 9.0 27270906

ETIM 5.0 EC001820

ETIM 6.0 EC001820

UNSPSC 16.0901 39121528

2020-03-11 11:43:34 | Product data sheet REGISTRATION SENSORS | SICK 3



Subject to change without notice
KT5W-2N1116 | KT5
CONTRAST SENSORS

A Dimensional drawing (Dimensions in mm (inch))


KT5-2 Teach-in, KT5-2 Display

B 9 (0.35)
56 (2.20)
28
(1.10)
Sensing distance
10 mm (0.39 inch)
Sensing distance
20 mm (0.79 inch)
Sensing distance
40 mm (1.57 inch)

Ø 25.5

Ø 25.6

(1.02)
(1.20)
(0.83)

(1.00)

(1.00)

Ø 26
30.4
M5

1
21

D
3.5 4.5 17.4
(0.14) (0.18) (0.69)

E
2
25 (0.98)

53 (2.09)
M

40 (1.57)
5

F 13 28 (1.10) 4
(0.12)
3

(0.51) 52 (2.05)
17 80 (3.15) 3
(0.67)
①  Lens (light transmission), can be exchanged for pos. 4

H ②  M5 threaded mounting hole, 5.5 mm deep


③  See dimensional drawings of lenses
④  Blind screw can be replaced by pos. 1
⑤  Connector M12 (rotatable up to 90°)

I
J Adjustments
KT5-2 Teach-in, KT5G-xxx6, KT5W-xxx6

K RUN

L
T
E
1 Q A
C
2
H

M 3

N TEACH

①  Function signal indicator (yellow)

O ②  Pre-selection switch
③  Teach-in button

P
Q
R
S
T 4 REGISTRATION SENSORS | SICK Product data sheet | 2020-03-11 11:43:34
Subject to change without notice
KT5W-2N1116 | KT5
CONTRAST SENSORS

Connection diagram
Cd-323

BN 1
+(L+)
BK 4
Q
BU 3
-(M)
WH 2
Not connected
GY 5
Teach

Concept of operation
KT5-2 Teach-in, teach-in static

1. Position mark 2. Position background

RUN RUN
T T
E E
A A
C C
H H

Turn rotary switch to “Teach” Press and hold teach-in button


position. Press and hold > 1 s.
teach-in button > 1 s. Yellow LED goes out.
Red emitted light and yellow
LED flash.

Example
Dark switching Light switching

Internal signal
received
Switching Switching
threshold threshold
Internal signal
received
Output Q Output Q

Switching characteristics
The optimum emitted light is selected automatically.
Light/dark setting is defined using teach-in sequence.
The switching threshold is set in the center between the background and the mark.
Teach-in can also be performed using an external control signal.

2020-03-11 11:43:34 | Product data sheet REGISTRATION SENSORS | SICK 5



Subject to change without notice
KT5W-2N1116 | KT5
CONTRAST SENSORS

A Sensing distance
Sensing distance

B 100

90
1
C 80

70

D 60

50
2
E
Relative sensitivity in %

40

30

F 20

10
3

0 10 20 30 40 50
(0.39) (0.79) (1.18) (1.57) (1.97)
Sensing distance in mm (inch)

H ①  Sensing distance 10 mm


②  Sensing distance 20 mm
③  Sensing distance 40 mm

I
J Recommended accessories

K Other models and accessories www.sick.com/KT5

Brief description Type Part no.

L
Universal bar clamp systems
Plate G for universal clamp bracket, steel, zinc coated, Universal clamp (2022726), BEF-KHS-G01 2022464
mounting hardware

M Plate K for universal clamp bracket, steel, zinc coated, Universal clamp (2022726),
mounting hardware
BEF-KHS-K01 2022718

N Universal clamp bracket for rod mounting, steel, zinc coated, without mounting hard- BEF-KHS-KH1 2022726
ware

O Mounting bar, straight, 200 mm, steel, steel, zinc coated, without mounting hardware BEF-MS12G-A 4056054

P
Mounting bar, straight, 300 mm, steel, steel, zinc coated, without mounting hardware BEF-MS12G-B 4056055

Mounting bar, L-shaped, 150 mm x 150 mm, steel, steel, zinc coated, without mounting BEF-MS12L-A 4056052
hardware

Q Mounting bar, L-shaped, 250 x 250 mm, steel, steel, zinc coated, without mounting
hardware
BEF-MS12L-B 4056053

R
S
T 6 REGISTRATION SENSORS | SICK Product data sheet | 2020-03-11 11:43:34
Subject to change without notice
KT5W-2N1116 | KT5
CONTRAST SENSORS

Brief description Type Part no.

Plug connectors and cables


Head A: female connector, M12, 5-pin, straight, A-coded YF2A15- 2096239
Head B: Flying leads 020VB5XLEAX
Cable: Sensor/actuator cable, PVC, unshielded, 2 m
Head A: female connector, M12, 5-pin, straight, A-coded YF2A15- 2096240
Head B: Flying leads 050VB5XLEAX
Cable: Sensor/actuator cable, PVC, unshielded, 5 m
Head A: female connector, M12, 5-pin, straight, A-coded YF2A15- 2096241
Head B: Flying leads 100VB5XLEAX
Cable: Sensor/actuator cable, PVC, unshielded, 10 m
Head A: female connector, M12, 5-pin, angled, A-coded YG2A15- 2096215
Head B: Flying leads 020VB5XLEAX
Cable: Sensor/actuator cable, PVC, unshielded, 2 m
Head A: female connector, M12, 5-pin, angled, A-coded YG2A15- 2096216
Head B: Flying leads 050VB5XLEAX
Cable: Sensor/actuator cable, PVC, unshielded, 5 m
Head A: female connector, M12, 5-pin, angled, A-coded YG2A15- 2096217
Head B: Flying leads 100VB5XLEAX
Cable: Sensor/actuator cable, PVC, unshielded, 10 m
Head A: female connector, M12, 5-pin, straight DOS-1205-G 6009719
Cable: unshielded

Head A: female connector, M12, 5-pin, angled DOS-1205-W 6009720


Head B: -
Cable: unshielded

Lenses and accessories


Lens, 40 mm sensing distance, M20 x 0.75 OBJ-210 2010945
Lens, 10 mm sensing distance, M20 x 0.75 OBJ-211 1004936
Lens, 20 mm sensing distance, M20 x 0.75 OBJ-212 1011506

2020-03-11 11:43:34 | Product data sheet REGISTRATION SENSORS | SICK 7



Subject to change without notice
SICK at a glance
Online data sheet

SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica-
tions. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.

We have extensive experience in a wide range of industries and understand their processes and require-
ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.

Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the ma-
chine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

Worldwide presence:
Contacts and other locations – www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com

You might also like