Open Frame Series
Open Frame Series
Open Frame Series
OUTLINE DIMENSIONS
1 .1 2 5
(2 8 .6 ) W
TABLE 1
.0 2 0 M IN .3 5 0
(0 .5 1 ) (8 .8 9 )
.1 2 5 (3 .1 8 )
. 0 2 2 ( 0 . 5 6 ) + /- .0 0 5 (0 .1 2 )
.1 0 0 (2 .5 4 )
1 .0 0 0
D IA . (T Y P ) o r . 1 5 0 ( 3 .8 1 )
(2 5 .4 )
TABLE 1
CONTACT FORM
1A or 1C 2A, 1B, 1J or 1K 3A 2B 2C 4A
W (1.000 x .100) .440 (11.18) .425 (10.79) .525 (13.33) .550 (13.97) .550 (13.97) .640(16.26)
W (1.000 x .150) .440 (11.18) .550 (13.97) NA .550 (13.97) .550 (13.97) NA
Notes:
1. Dimensions are in inches (mm) 3. Unused terminals are deleted.
2. Tolerance unless otherwise specified is
+\- .015” (0.38 mm)
Contact Ratings:
Power (Resistive load) 10 Watts 3 Watts
Voltage (Max. switching) 200 VDC 100 VDC
Current (Max. switching) 0.5 Amps 0.25 Amps
(Max. carrying) 2.0 Amps 1.2 Amps
Breakdown Voltage (Min.) (Across contact) 300 VDC 200 VDC
Contact Resistance (Max. Initial) 0.2 Ohms 0.2 Ohms
Operating Time (Typical) 0.5 mSec 0.5 mSec
Release Time (Typical) 0.2 / 0.5 mSec 0.5 mSec
Bounce Time (Typical) 0.25 mSec NO / NC : 0.5 / 1.5 mSec
10
Insulation Resistance (Min.) 10 Ohms 109 Ohms
Capacitance (Typical) 0.2 pF 0.8 pF
Life Expectancy:
Low level: 100 x 106 Operations 50 x 106 Operations
6 6
Rated load: 10 x 10 Operations 5 x 10 Operations
o o
-40 C to +85oC
o
Operating Temperature -40 C to +85 C
Vibration 20G, 10 to 2000 Hz 20G, 10 to 2000 Hz
Shock 50G @ 11 MS durations 50G @ 11 MS durations
OPTIONAL FEATURES:
1. Change the last digit (O) of a part number to (A) for Magnetic shield, to (B) for Electro-static shield, and to
(C) for both Magnetic and Electro-static shields.
2. For .150” pin spacing, change the first digit (C) to (F) for end coil, and (D) to (G) for side coil.
American Relays, Inc. (562) 944-0447, Fax (562) 944-0590, E-mail: [email protected]
2
OPEN FRAME SERIES REED RELAYS
PART NUMBERS AND COIL DATA (@ 25OC)
Coil
Nom. Max. Must Must Schematic Schematic
Contact Part Number Part Number Res.
Voltage Voltage Operate Release Top-view Top-view
Form (End coil) (Side coil) Ohms
VDC VDC VDC VDC (End coil) (Side coil)
+/-10%
C051A1RO D051A1RO 125
C051A2RO D051A2RO 5 7.5 500 3.8 0.5
C051A3RO D051A3RO 750
C061A1RO D061A1RO 125
2 1 2
C061A2RO D061A2RO 6 9 500 4.5 0.6
3 4
1A C061A3RO D061A3RO 750 3 4
1 E E
C121A1RO D121A1RO 750
C121A2RO D121A2RO 12 18 1000 9.0 1.2
C121A3RO D121A3RO 2000
C241A2RO D241A2RO 2000
24 36 18.0 2.4
C241A3RO D241A3RO 4000
C052A1RO D052A1RO 100
C052A2RO D052A2RO 5 7.5 300 3.8 0.5
C052A3RO D052A3RO 500
C062A1RO D062A1RO 100
C062A2RO D062A2RO 6 9 300 4.5 0.6 2 1 2
3 4
2A C062A3RO D062A3RO 500 3 4
5 6
C122A1RO D122A1RO 300 5 6
1 E E
C122A2RO D122A2RO 12 18 750 9.0 1.2
C122A3RO D122A3RO 1500
C242A2RO D242A2RO 1500
24 36 18.0 2.4
C242A3RO D242A3RO 3000
C053A1RO D053A1RO 75
C053A2RO D053A2RO 5 7.5 250 3.8 0.5
American Relays, Inc. (562) 944-0447, Fax (562) 944-0590, E-mail: [email protected]
3
OPEN FRAME SERIES REED RELAYS
PART NUMBERS AND COIL DATA (@ 25OC)
Coil
Nom. Max. Must Must Schematic Schematic
Contact Part Number Part Number Res.
Voltage Voltage Operate Release Top-view Top-view
Form (End coil) (Side coil) Ohms
VDC VDC VDC VDC (End coil) (Side coil)
+/-10%
C051C1RO D051C1RO 125
American Relays, Inc. (562) 944-0447, Fax (562) 944-0590, E-mail: [email protected]
4
OPEN FRAME SERIES REED RELAYS
PART NUMBERS AND COIL DATA (@ 25OC)
Coil
Nom. Max. Must Must Schematic Schematic
Contact Part Number Part Number Res.
Voltage Voltage Operate Release Top-view Top-view
Form (End coil) (Side coil) Ohms
VDC VDC VDC VDC (End coil) (Side coil)
+/-10%
C052B1RO D052B1RO 100
5 7.5 3.8 0.5
C052B2RO D052B2RO 300
C051K1RO D051K1RO 75
C061K1RO D061K1RO 75
1A + + - +
C061K2RO D061K2RO 6 9 250 4.5 0.6 2 61 2
LATCH E 3 4
DUAL C061K3RO D061K3RO 375
3 4E
COIL
C121K1RO D121K1RO 375 1- -5 5+ -6
(1K)
C121K2RO D121K2RO 12 18 500 9.0 1.2
NOTES:
1. On latching relays, either coil will close the contact(s) with the polarity shown on the schematic. Reversing the
polarity opens the contact(s).
2. Open frame reed relays with contact forms, coil resistances and operating voltages other than shown in this catalog
are available.
3. Electrostatic shield is optional (Shield pin is E on schematic).
American Relays, Inc. (562) 944-0447, Fax (562) 944-0590, E-mail: [email protected]