0% found this document useful (0 votes)
69 views1 page

Flange Management / Bolt Tightening: 1 7 C 3 2 0 0 B Sub-System NO. Test Package

This document provides instructions for bolting a flange connection between an upper and lower stream near JT.1. It specifies using 8 bolts with a 5/8 inch diameter and torquing each bolt to 120 Nm using a wrench. No pump pressure or other tools are required. Two notes provide additional guidance: install all pipe supports first and grease each bolt with thread lubricant.

Uploaded by

angelito bernal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views1 page

Flange Management / Bolt Tightening: 1 7 C 3 2 0 0 B Sub-System NO. Test Package

This document provides instructions for bolting a flange connection between an upper and lower stream near JT.1. It specifies using 8 bolts with a 5/8 inch diameter and torquing each bolt to 120 Nm using a wrench. No pump pressure or other tools are required. Two notes provide additional guidance: install all pipe supports first and grease each bolt with thread lubricant.

Uploaded by

angelito bernal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

PP-008

1FLANGE MANAGEMENT / BOLT TIGHTENING


7 1 of 1
C
317C3200B
Project No. Area AEU/C1600
2
0
SUB-SYSTEM 0 TEST
### N-1700-P-05-01 N-1700-P-05-01-P-A004
NO. B PACKAGE

TENSION
FLANGE BOLTS Pump Pressure TORQUE
Width Bolt
Across Stress (PSI)
Flat Nmm2 Pump
Flange Nominal Number Number
Diameter Tools Pass A Pass B Mom. Nm Tools Pressure
Number Diameter Off Off
(PSI)
Torque
4 1 5/8 NA NA NA NA NA NA 120 Wrench N/A
Torque
Upper & Lower Stream Near JT.1

4 2 5/8 NA NA NA NA NA NA 120 Wrench N/A


C1700A1A-P-17190-02

Torque
4 3 5/8 NA NA NA NA NA NA 120 Wrench N/A
Torque
4 4 5/8 NA NA NA NA NA NA 120 Wrench N/A
Torque
4 5 5/8 NA NA NA NA NA NA 120 Wrench N/A
Torque
4 6 5/8 NA NA NA NA NA NA 120 Wrench N/A
Torque
4 7 5/8 NA NA NA NA NA NA 120 Wrench N/A
Torque
4 8 5/8 NA NA NA NA NA NA 120 Wrench N/A

Note 1 : Prior to pulling up joints, ensure all pipe supports have been installed and completed as per the P&IDs.

Note 2: Grease each bolt with thread lubricant (Type: TBA).

AG&P CTCI OWNER Comments / Remarks:

Name

Signature

Date

Rev. 0, 03-Oct-18