Tengs Distribution
Tengs Distribution
el = 314.85 = 0.33 m
959.81
eb = 695.79 = 0.72 m
959.81
From Teng's Chart
el/L = 0.33 = 0.047 m K = 2.1
7.00 x = 0.12
eb/B = 0.72 = 0.117 m y = 0.12
6.20
CASE 2 IS APPLICABLE
3 6.750 2
1.00
ML
L
5.50 3.50
MT 1.00
4
1
2.75 1.25 2.75
MODIFIED AREA OF FOOTING = 37.13 m2
3
MODIFIED ZL = 34.03125 m
4
MODIFIED ZT = 41.765625 m
P1 = P - ML + MT = 12.946
A ZL ZT
P2 = P + ML + MT = 53.838
A ZL ZT
P3 = P + ML - MT = 38.760
A ZL ZT
P4 = P - ML - MT = -2.131
A ZL ZT
CASE 2
1.00
10 11
ML
5.50 3.50 0.00
4
12 13
MT
YxB 1.00
AREA
UNDER XxL 5 1
TENSION 2.75 1.25 2.75
K = 2.1
X = 0.12
Y = 0.12
2
= 54.29 T/m < 81.00 Hence OK
AREA UNDER TENSION
2
0.5 X 0.81 X 0.66 = 0.27 m
P M L' MT'
960 678 293