DS211 User Manual
DS211 User Manual
DS211 User Manual
V1.07
Contents
I. Product Overview P1
III. Functions P2
IV. Parameters P3
V. Operational Environment P3
1
III. Functions
1uS/Div~2S/Div
Horizontal sensitivity
(1-2-5sequence step)
20mV/Div~10V/Div(x1probe)
Vertical sensitivity
0.2V/Div~100V/Div(x10probe)
Analog input impedance >500KΩ
Coupling AC/DC
10Hz~1MHz
Inbuilt signal Generator
(1-2-5sequence step)
2
IV. Parameters
Weight 66g
Battery 500mAH
Size 106mm×55.5mm×11mm
V. Operational Environment
Humidity:
3
VI. General Inspections
When you get a new DS211 oscilloscope, you are advised to inspect
the product by the following steps.
1. Inspect damages caused by shipping.If the packaging carton or
the protection pad is seriously damaged, keep the package until the
oscilloscope & accessories pass the electrical and the mechanical test.
2. Inspect the product.Please contact the dealer if the following
problems occur to DS211: 1) product appearance is damaged, 2)
product doesn't work properly, 3) product does not pass performance
test.If the damage to DS211 is resulted from shipping, please keep
the package.
4
IX. Firmware Upgrading
Menu
5
See below for functions of each button:
Run/pause button
Save parameter
+ Slide Up
- Slide Down
On/Off Sub-menu
M
Save BMP(long press)
Auto Fit(double press)
A B C D E F G H
Parameters
Options
Parameters
I J K L
Main Screen
6
XI. Measurement Instructions
1、Parameters Introduction
F Trigmode:Rising/
falling edge
H AUTO/NORM/SINGL/SCAN Automatic/Normal/Single/Scan
7
2、Options Introduction
Use the "+" or "-" key to choose the options on the sliding option
area, press “M” to unfold option setting menu; use the "+" or "-"
key to select the parameter option you need and change the
current parameter value at blinking cursor via the “ ” or “ ”key.
Note: After all the changes to setting are finished, long press “ ”
to save the changes in accordance with prompts.
8
1)Yn Parameter Notes
9
3)Tr Parameter Notes
10
5)Ex Parameter Notes
11
6)Fn Parameter Notes
Save Bmp Save bmp file (waveform figure) into flash disk
Save Dat Save dat file into flash disk
Save Buf Save buf file (sampling buffer data) into flash disk
Save Csv Save csv file (export sampling buffer data) into flash disk
Save Svg Save svg file (sampling buffer figure) into flash disk
Load Dat Load Dat file
Load Buf Load Buf file
12
7)Sn Parameter Notes
PowerOff Adjust power off time(Press or to choose a power-off timeof 0-60 mins)
When connected to PC via USB data cord, it will not activate auto
power-off.
13
XII. Certification Marks
14