Pump Cycle Calculator: Input Data

This document contains a pump cycle calculator that takes input data like wet well diameter, pump down distance, average pump flow, and average inflow to calculate results like pump down volume, wet well fill time, run time with and without inflow, and starts per hour with inflow. It provides these calculations for a range of average inflow values from 50 to 250 gallons per minute. A graph shows the relationship between starts per hour and inflow in gallons per minute.

Uploaded by

Gustavo1722
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views2 pages

Pump Cycle Calculator: Input Data

This document contains a pump cycle calculator that takes input data like wet well diameter, pump down distance, average pump flow, and average inflow to calculate results like pump down volume, wet well fill time, run time with and without inflow, and starts per hour with inflow. It provides these calculations for a range of average inflow values from 50 to 250 gallons per minute. A graph shows the relationship between starts per hour and inflow in gallons per minute.

Uploaded by

Gustavo1722
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

PUMP CYCLE CALCULATOR

INPUT DATA

Wet Well Diameter (inches) 96


Pump Down Distance (feet) 3.0
Average Pump Flow (gpm) 500
Surcharge Volume (if applicable) 0
Average InFlow (gpm) 50 100 150 200 250

CALCULATED RESULTS

Pump Down Volume (gal) 1127


Wet Well Fill Time (min) 22.5 11.3 7.5 5.6 4.5
Run Time (min) No inflow 2.3
Run Time (min) With Inflow 2.5 2.8 3.2 3.8 4.5
Starts / hr With Inflow 2.4 4.3 5.6 6.4 6.7

Enter the required data in cells D8 through D12. You may enter
additional inflows in cells D12 through H12 for a comparison.

If a surcharge volume is entered in D11, it will be included in


in all calculations.

Starts
Inflow
Run / hour graph
time 50.0
2.5
2.4 55.6
2.5
2.6 62.5
2.6
2.9 71.4
2.6
3.3 83.3
2.7
3.7 100.0
2.8
4.3
7

300 4

1
3.8
0
0 50 100 150 200 250 300 350 400 450 500
5.6
6.4

Starts / Hour versus Inflow in GPM


hrough D12. You may enter
gh H12 for a comparison.

D11, it will be included in

125.0
3.0
5.0 166.7
3.4
5.9 250.0
4.5
6.7 333.3
6.8 416.6667
5.9 13.5
3.7 454.5
24.8
2.2