ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

Advanced
metering
applications
Advanced high performance meters are designed for mains or critical loads
on MV/LV networks. They provide analysis of efficiency, losses and capacity,
bill verification, power quality compliance monitoring, problem notification and
diagnosis and control of loads, etc.

104 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

Advanced
metering
Power quality meters are classified as advanced meters designed to monitor service entrances and
critical network locations to maximize power availability and reliability by providing a comprehensive
system load profile, power quality and root cause analyses.

• • PowerLogic™ PM8000
• • PowerLogic™ ION9000
PB113687
P115913

METSEPM8240 M7650

Version: 1.0 - 29/08/2019


PLSED309005EN_06
105
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

PM8000 Series
The PowerLogic™ PM8000 series meters are compact, cost-effective multifunction power meters that
will help you ensure reliability and efficiency of your power-critical facility.
Reveal and understand complex power quality conditions. Measure, understand and act on insightful data gathered from
your entire power system. Designed for key metering points throughout your energy infrastructure, the PowerLogic PM8000
series meter has the versatility to perform nearly any job you need a meter to do, wherever you need it!

Applications
Ideal for low to high voltage applications in industrial facilities, data centers, infrastructure and other
critical power environments.
PB113687

METSEPM8240

106 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

PM8000 series
The solution for Power management solutions
Markets that can benefit from a solution that includes PowerLogic Schneider Electric provides innovative
PM8000 series meters: power management solutions to increase
• Industry your energy efficiency and cost savings,
• Data centers maximize electrical network reliability and
• Infrastructure availability, and optimise electrical asset
• Healthcare performance.
• Buildings

Conformity of standards
Benefits • EN 50160 • IEC 62053-11
• EN 50470 • IEC 62053-22
• Makes understanding power quality simple to help
• IEC 61000-4-30 • IEC 62053-23
operations personnel avoid downtime and helps ensure
increased productivity and equipment life. • IEC 61010-1 • IEC 62053-24
• Makes energy and power quality immediately relevant and • IEC 61326-1 • IEC 62586-2
actionable to support your operational and sustainability • IEC 61557-12 • IEEE 519
goals. • IEC 62052-11 • UL 61010-1

Competitive advantages
• Modular, flexible patented ION technology architecture
enables a simple building block approach.
• Disturbance direction detection, modularity and compliance
with latest power quality standards.
• Color screen.
• Multiple communication options.
• Excellent accuracy.

Version: 1.0 - 29/08/2019


PLSED309005EN_06
107
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

PM8000 series Main characteristics


• Precision metering:
–– IEC 61557-12 PMD/SD/K70/0.2 and PMD/SS/K70/0.2 3000m (performance
PB113641

measuring and monitoring functions).


–– Class 0.2S accuracy IEC 62053-22, ANSI C12.20 Class 0.2 (active energy).
–– Industry leading Class 0.5S accuracy for reactive energy (IEC 62053-24).
–– Cycle-by-cycle RMS measurements updated every ½ cycle.
–– Full ‘multi-utility’ WAGES metering support.
–– Net metering.
–– Anti-tamper protection seals.

• PQ compliance reporting and basic PQ analysis:


–– Monitors and logs parameters in support of international PQ standards,
–– IEC 61000-4-30 Class S (test methods as per IEC 62586-2).
–– Generates onboard PQ compliance reports accessible via onboard web pages:
–– Basic event summary and pass/fail reports, for EN 50160 for power frequency,
supply voltage indication, supply voltage dips, short and long interruptions,
temporary over voltages, voltage unbalance and harmonic voltage.
PowerLogic PM8000 series meter.
–– ITIC (CBEMA) and SEMI curves, with alarm categorization to support
further analyses.
–– NEMA Motor Derating curve.
PB113668

–– Pass/fail report for IEEE 519 for voltage and current harmonic limits.
–– Harmonic analysis:
–– THD on voltage and current, per phase, min/max, custom alarming.
–– Individual harmonic magnitudes and angles on voltage and current,
up to the 63rd harmonic.
–– High resolution waveform capture: triggered manually or by alarm,
captured waveforms available directly from the meter via FTP in a
COMTRADE format.
–– Disturbance detection and capture: sag/swell on any current and voltage channel,
alarm on disturbance event, waveform capture with pre-event information.
–– Patented disturbance direction detection: provides indication of the captured
disturbance occurring upstream or downstream of the meter; timestamped results
provided in the event log, with degree of certainty of disturbance direction.
PowerLogic PM8000 series meter - rear view.
• Used with Schneider Electric’s sophisticated software tools, provides
detailed PQ reporting across entire network:
–– EN 50160 report.
–– IEC 61000-4-30 report.
PB113692

–– IEEE 519 harmonic compliance report.


–– PQ compliance summary.
–– Display of waveforms and PQ data from all connected meters.
–– Onboard web-based waveform viewer.
–– Energy reports for consumption analysis and cost management.
–– WAGES dashboards and reports.
–– EcoStruxure Power Events Analysis, including alarm management,
sequence of events, and root cause analysis.

• Cybersecurity:
–– Security events logging with Syslog protocol support.
PowerLogic PM8000 DIN rail mounted meter. –– HTTPS secure protocol.
–– Ability to enable or disable any communication port and any protocol per port.
–– Anti-tamper protection seals and hardware metrology lock.
–– User accounts with strong passwords.

• Data and event logging:


–– Onboard data and event logging.
–– 512 MB of standard non-volatile memory.

108 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

PM8000 series M Main characteristics

Main characteristics (contd.)


–– No data gaps due to network outages or server downtime.
–– Min/Max log for standard values.
PB113669

–– 50 user-definable data logs, recording up to 16 parameters on a cycle-by-


cycle or other user definable interval.
–– Continuous logging or ‘snapshot’ triggered by setpoint and stopped after
defined duration.
–– Trend energy, demand and other measured parameters.
–– Forecasting via web pages: average, minimum and maximum for the next
four hours and next four days.
–– Advanced time-of-use capability.
–– Security / event log: alarm conditions, metering configuration changes,
power outages, firmware download, and user login/logout all timestamped
PowerLogic PM8000 series meter with remote display. to ±1 millisecond.

• Alarming and control:


–– 50+ definable alarms to log critical event data, trigger waveform recording,
or perform control function.
–– Trigger on any condition, with 1/2-cycle and 1-second response time.
PB113671

–– Combine alarms using Boolean logic and to create alarm levels.


–– Alarm notification via email.
–– In conjunction with Schneider Electric’s EcoStruxure software, alarms,
software alarms, and alarm frequency are categorized and trended
enabling sequence of events and root cause analyses.

Usability
• Easy installation and setup:
–– Panel and DIN rail mounting options, remote display option.
–– Pluggable connectors.
–– Free setup application simplifies meter configuration.
PowerLogic I/O module. –– Auto-discovery using DPWS (Device Profile Web Services).
–– DHCP for automatic IP address configuration.

• Front panel:
–– Easy to read color graphic display.
–– Simple, intuitive menu navigation with multi-language (8) support.

• Flexible remote communications:


–– Multiple simultaneously operating communication ports and protocols
allow interfacing with other automation systems; (e.g. waveforms, alarms,
billing data, etc.) can be uploaded for viewing/analysis while other systems
access real-time information.
–– Supports Modbus, ION, DNP3, IEC 61850.
–– Dual port Ethernet: 10/100BASE-TX; supports IPV4 and IPV6; daisy-
chaining capability removes need for additional switches.
–– Secure web interface with HTTPS and TLS 1.2 with support for user-
provided certificates.
–– Create redundant network loop using Rapid Spanning Tree Protocol (RSTP)
and managed Ethernet switches.
–– Customize TCP/IP port numbers and enable/disable individual ports.
–– RS-485 2-wire connection, up to 115,200 baud, Modbus RTU, ION and
DNP3 protocols.
–– Ethernet to serial gateway with Modbus Master functionality, connecting to
31 downstream serial Modbus devices. Also supports Modbus Mastering
over TCP/IP (Ethernet) network.
–– Full function web server with factory and customizable pages to access
real-time and PQ compliance data.
–– Push historical data via email.
–– Advanced security: Up to 50 configurable user accounts.

Version: 1.0 - 29/08/2019


PLSED309005EN_06
109
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

PM8000 series
• Time synchronization via:
PB113686

–– GPS clock (RS-485) or IRIG-B (digital input) to ±1 millisecond.


–– Network Time Protocol (NTP/SNTP).
–– Precision Time Protocol (PTP - IEEE 1588 / IEC 61588).
–– Time set function from Schneider Electric software server.

Adaptability
–– ION™ frameworks allow customisable, scalable applications, object-oriented
programming, compartmentalizes functions, and increases flexibility and
adaptability.
–– Applications include: access and aggregate data from Modbus devices
on serial port or across the network (Modbus TCP/IP), logging and/or
PowerLogic PM8000 series meter with I/O modules. processing data by totaling, unit conversion or other calculations, applying
complex logic for alarming or control operations, data visualization via web
pages.

Standard meter I/O


PB119094

• 3 digital status/counter inputs.


• 1 KY (form A) energy pulse output for interfacing with other systems.

Modular I/O options


• Optional expansion modules.
• Up to 4 modules per meter.

Option modules include:


• Digital module:
–– 6 digital status/counter inputs.
PowerLogic PM8000 series waveform web page sample
–– 2 Form C relay outputs, 250 V, 8 A.
• Analog module:
–– 4 analog inputs (4-20 mA; 0-20 mA; 0-30 V).
–– 2 analog outputs (4-20 mA; 0-20 mA; 0-10 V) for interfacing with building
PB119093

management sensors and systems.

PowerLogic PM8000 series CBEMA web page sample


PB119095

PowerLogic PM8000 series PQ harmonics web page sample

110 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

PM8000 series
PB113696

Feature guide PM8000

General
Use on LV, MV, and HV systems b
Current accuracy 0.1 % reading
Voltage accuracy 0.1 % reading
Active energy accuracy 0.2 Class
Number of samples/cycle or sample frequency 256
Instantaneous rms values
Current, voltage, frequency b
Active, reactive, apparent power Total and per phase b
Power factor Total and per phase b
Current measurement range (autoranging) 0.05 - 10 A
Energy values
Active, reactive, apparent energy b
Settable accumulation modes b

Demand values
Underside of PM8000 meter (DIN rail version).
Current Present and max. values b
Active, reactive, apparent power Present and max. values b
Predicted active, reactive, apparent power b
Synchronization of the measurement window b
Feature selection Setting of calculation mode Block, sliding b
Commercial Power quality measurements
Description
reference number b
Harmonic distortion Current and voltage
96 x 96 panel mount meter, Via front panel and web page 63
METSEPM8240 Individual harmonics
AC/DC power.
Via EcoStruxure™ software 127
96 x 96 panel mount meter, Waveform capture b
METSEPM8210
LV DC power. b
Detection of voltage swells and sags
DIN rail mount meter, Fast acquisition 1/2 cycle data b
METSEPM8243
AC/DC power. b
EN 50160 compliance checking
DIN rail mount meter, IEEE 519 compliance checking b
METSEPM8213
LV DC power. b
Customizable data outputs (using logic and math functions)
DIN rail mount meter with remote Data recording
METSEPM8244
display, AC/DC power.
Min/max of instantaneous values b
DIN rail mount meter with remote b
METSEPM8214 Data logs
display, LV DC power.
Event logs b
METSEPM82401 MID approved panel mount meter. Trending/forecasting b
SER (Sequence of event recording) b
RMICAN approved panel mount
METSEPM82403 Time stamping b
meter.
GPS synchronization (+/- 1 ms) b
RMICAN sealed panel mount
METSEPM82404 Memory (in Mbytes) 512
meter.
Display and I/O
Accessories Description Front panel display b
Wiring self-test b
Remote display, 3 metre cable,
mounting hardware for Pulse output 1
30 mm hole (nut & centering pin),
METSEPM89RD96 27 digital
mounting hardware Digital or analog inputs(max)
16 analog
for DIN96 cutout (92 x 92 mm)
adapter plate 1 digital
Digital or analog outputs (max, including pulse output) 8 relay
Digital I/O module (6 digital 8 analog
METSEPM89M2600
inputs & 2 relay outputs)
Communication
Analog I/O module (4 analog
METSEPM89M0024 RS-485 port 1
inputs & 2 analog outputs)
Ethernet port 2
Replacement hardware kit
Serial port (Modbus, ION, DNP3) b
METSEPM8HWK (connectors, screws, retainer
clips, mounting template) Ethernet port (Modbus/TCP, ION TCP, DNP3 TCP, DHCP, DNS, IPv4, IPv6, b
IEC 61850)
Ethernet gateway b
Alarm notification via email b
HTTP/HTTPs web server with waveform viewer b
SNMP with custom MIB and traps for alarms b
SMTP email b
PTP and NTP time synchronization b
FTP file transfer b

Version: 1.0 - 29/08/2019


PLSED309005EN_06
111
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

PM8000 series
Technical specifications
Electrical characteristics
Type of measurement True rms to 256 samples per cycle

Current & voltage Class 0.2 as per IEC 61557-12

Active Power Class 0.2 as per IEC 61557-12

Power factor Class 0.5 as per IEC 61557-12

Measurement Frequency Class 0.02 as per IEC 61557-12


accuracy
Class 0.2S IEC 62053-22
Active energy
Class 0.2 IEC 61557-12, ANSI C12.20 Class 0.2

Reactive Energy Class 0.5S IEC 62053-24*

MID Directive EN 50470-1, EN 50470-1, AnnexB & AnnexD (optional model)

Display refresh rate 1/2 cycle or 1 second

Specified accuracy voltage 57 - 400 V L-N / 100 - 690 V L-L

Impedance 5 MW per phase


Input-voltage Specified accuracy 42 to 69 Hz
characteristics frequency - Frequency (50/60 Hz nominal)

Limit range of operation -


20 to 450 Hz
frequency

Rated nominal current 1 A (0.2S), 5 A (0.2S) , 10 A (0.2 ANSI)

Specified accuracy Starting Current: 5 mA


current range Accurate Range: 50 mA - 10 A
Input-current
characteristics Permissible overload 200 A rms for 0.5s, non-recurring

Impedance 0.0003 W per phase


Burden 0.01 VA max at 5 A

AC 90-415 V AC ±10 % (50/60 Hz ±10 %) 90-120 V AC +/- 10% (400 Hz)

DC 110-415 V DC ±15 % (20-60 V DC ±10 % for PM8210

Power supply 100 ms (6 cycles at 60 Hz) min., any condition


AC/DC Ride-through time 200 ms (12 cycles at 60 Hz) typ., 120 V AC
500 ms (30 cycles at 60 Hz) typ., 415 V AC

Typical: 7.7 W / 16 VA at 230 V (50/60 Hz)


Burden
Fully optioned: max. 18 W / 40 VA at 415 V (50/60 Hz).

DC 20 to 60 V DC ±10 %
Power supply
LV DC
Burden Fully optioned: max. 18 W at 18 to 60 V DC

3 digital inputs (30 V AC/60 V DC)


Meter Base Only
1 form A (KY) solid state digital output (30 V AC/60 V DC, 75 mA).
Input/outputs
Digital - 6 digital inputs (30 V AC / 60 V DC) wetted + 2 form C relay outputs (250 V AC, 8 A)
Optional
Analog - 4 analog inputs (4-20 mA, 0-30 V DC) + 2 analog outputs (4-20 mA, 0-10 V DC).

Mechanical characteristics
Integrated Display Model 0.581 kg
DIN rail mounted Model 0.528 kg
Weight
IO modules 0.140 kg
Remote display 0.300 kg
IP 54, UL type 12: Panel mount and Remote display, front.
IP degree of protection
IP 30: Panel mount rear, DIN rail mount, I/O modules.
Excellent quality ISO 9001 and ISO 14000 certified manufacturing.
Panel mount model 96 x 96 x 77.5 mm
DIN model 90.5 x 90.5 x 90.8 mm
Dimensions
Remote display 96 x 96 x 27 mm
IO modules 90.5 x 90.5 x 22 mm

112 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

PM8000 series
Environmental conditions
Operating temperature -25 ºC to 70 ºC

Remote Display Unit -25 ºC to 60 ºC

Storage temperature -40 ºC to 85 ºC

Humidity rating 5 % to 95 % non-condensing

Installation category III

Operating altitude (maximum) 3000 m above sea-level

Electromagnetic compatibility
EMC standards IEC 62052-11 and IEC 61326-1

Immunity to electrostatic discharge IEC 61000-4-2

Immunity to radiated fields IEC 61000-4-3

Immunity to fast transients IEC 61000-4-4

Immunity to surges IEC 61000-4-5

Immunity to conducted disturbances IEC 61000-4-6

Immunity to power frequency


IEC 61000-4-8
magnetic fields

Immunity to conducted disturbances,


CLC/TR 50579
2-150kHz

Immunity to voltage dips &


IEC 61000-4-11
interruptions

Immunity to ring waves IEC 61000-4-12

Conducted and radiated emissions EN 55022, EN 55011, FCC part 15 Class B, EN55011, EN55022 Class B, ICES-003 Class B

Surge withstand Capability (SWC) IEEE / ANSI C37.90.1

Safety
IEC/EN 61010-1 ed.3, CAT III, 400 V L-N / 690 V L-L
Safety Construction UL 61010-1 ed.3 and CSA-C22.2 No. 61010-1 ed.3, CAT III, 347 V L-N / 600 V L-L
IEC/EN 62052-11, protective class II.

Communication
Ethernet to serial line gateway Communicates directly with up to 31 unit load devices.

Web server Customisable pages, new page creation capabilities, HTML/XML compatible.

Serial port RS-485 Baud rates of 2400 to 115200, pluggable screw terminal connector.

Ethernet port(s) 2x 10/100BASE-TX, RJ45 connector (UTP).

Protocol Modbus, ION, DNP3, IEC 61850, HTTPS, FTP, SNMP, SMTP, DPWS, RSTP, NTP, PTP, NTP/SNTP, GPS, IPv4 /IPv6, DHCP, Syslog protocols.

Firmware characteristics
Down to 1/2 cycle interval burst recording, stores detailed characteristics of disturbances or outages. Trigger
High-speed data recording
recording by a user-defined setpoint, or from external equipment.

Harmonic distortion Up to 63rd harmonic (127th via Schneider Electric software) for all voltage and current inputs.

Analyse severity/potential impact of sags and swells: magnitude and duration data suitable for plotting on voltage
Sag/swell detection
tolerance curves per phase triggers for waveform recording, control.

Determine the location of a disturbance more quickly and accurately by determining the direction of the
Disturbance direction detection disturbance relative to the meter. Analysis results are captured in the event log, along with a timestamp and
confidence level indicating level of certainty.

High accuracy of standard speed (1s) and high-speed (1/2 cycle) measurements, including true rms per phase
Instantaneous and total for: voltage, current, active power (kW),reactive power (kvar), apparent power (kVA), power factor,
frequency, voltage and current unbalance, phase reversal.

Channel assignments (800 channels via 50 data recorders) configurable for any measurable parameter, including
Load profiling historical trend recording of energy, demand, voltage, current, power quality, or any measured parameter. Trigger
recorders based on time interval, calendar schedule, alarm/event condition, or manually.

Historical trends and future forecasts to better manage demand, circuit loading, and other parameters. Provides
Trend curves average, min, max and standard deviation every hour for last 24 hours, every day for last month, every week for last
8 weeks and every month for last 12 months.

Simultaneous capture of all voltage and current channels, sub-cycle disturbance capture, ability to record from 210
Waveform captures cycles at 256 sample per cycle to over 2880 cycles at 16 points per cycle with user selectable sampling speed as
well as pre- and post-trigger length.

Threshold alarms: adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type
Alarms
of alarm, user-defined or automatic alarm threshold settings, user-defined priority levels (optional automatic alarm setting).

Advanced Time of Use (TOU) 6 seasons; 3 different day types: weekend, weekday, and holiday; up to 8 tariffs per day type.

Version: 1.0 - 29/08/2019


PLSED309005EN_06
113
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

PM8000 series
Firmware characteristics (cont.)
Advanced security Up to 50 users with unique access rights. Perform resets, time sync, or meter configurations based on user privileges.

Memory 512 MB.

Firmware update Update via the communication ports.

Display characteristics
Integrated or Remote display 320 x 240 (1/4 VGA) Color LCD, configurable screens , 5 buttons and 2 LED indicators (alarm and meter status).

Languages English, French, Spanish, Russian, Portugese, German, Italian, Chinese.

Notations IEC, IEEE.

The HMI menu includes


Alarms Active alarms, historic alarms (50+ alarms).

Basic Reading Voltage, current, frequency, power summary.

Power Power summary, demand, power factor.

Energy Energy total, delivered, received.

Events Timestamped verbose event log.

Power Quality EN 50160, IEEE 519, harmonics, phasor diagrams.

Inputs/Outputs Digital inputs, digital outputs, analog inputs, analog outputs.

Nameplate Model, serial and FW version.

Custom Screens Build your own metrics.

Meter setup, communications setup, display setup, date/time/clock setup, alarm setup, language setup, time of use
Setup Menu setup, resets, password setup.

PM8000 series parts


PB119092

PB113642

A Voltage inputs P Alarm icon


B Control power Q Display
C Digital inputs R Navigation icons
D Revenue lock LED (green) Up
E Status LED (green/red) Down
F Revenue lock switch Select
G Digital output
Cancel
H Sealing gasket
I Infrared energy pulsing LED Edit
J Energy pulsing LED More
K RS-485
L Current inputs S Navigation buttons
M Ethernet (2) T Home button
N Date/time U Alarm LED (red)
O Revenue lock icon V Bar graph

114 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING DIMENSIONS AND CONNECTION

PM8000 series
PM8000 panel mount meter dimensions
PB119087

PM8000 DIN rail mount meter dimensions


PB119088

PM8000 remote display dimensions


PB119089

PM8000 with I/O modules dimensions


PB119090

PB119086

Please see the appropriate Installation Guide for accurate and complete information on the installation of this product.

Version: 1.0 - 29/08/2019


PLSED309005EN_06
115
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

ION9000 Series
The PowerLogic™ ION9000 is your 24/7 power quality expert, providing information, not just data.
With a comprehensive, industry-leading Power Quality Instrument (PQI) performance designation according to IEC 62586-
1/-2, the PowerLogic ION9000 is third-party certified ANSI C12.20 Class 0.1 and IEC 62053-22 Class 0.1S accurate, the
most accurate power meter available today. Lab-verified power quality and safety ensure reliable, precision performance
that is perfect for supply- or demand-side applications. Its patented Disturbance Direction Detection also helps you pinpoint
the source of power quality issues faster. Capable of sampling at 10 MHz, the ION9000T captures extremely fast voltage
events that are missed by most other power meters, enabling advanced diagnostics and high-resolution event associations
for fast, conclusive diagnosis and resolution to transient voltages.

Highly customizable and modular, the ION9000’s field programmability can adapt to satisfy any solution, protecting your
investment now and in the future. All designed to align with your comprehensive grid cybersecurity policies and backed by
Schneider Electric’s global services and support.

Applications
Ideal for critical power and large energy users who cannot afford to be shut down, the ION9000T has High-Speed Transient
Capture (HSTC) to detect and record transient events that exceed the voltage withstand of sensitive equipment.
PB115917

METSEION92040

116 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

The market solution for Power management solutions


Markets that benefit from a solution that includes PowerLogic Schneider Electric provides innovative
ION9000 series meters: power management solutions to increase
• Data centers your energy efficiency and cost savings.
• Healthcare facilities Maximize electrical network reliability and
• Semiconductor availability, and optimize electrical asset
• Pharmaceutical & chemical performance.
• Energy industries
• Mining, Minerals, & Metals
• Renewable energy interconnects
Conformity of standards
• Medium voltage distribution & energy automation • ANSI C12.20 • IEC 62052-11
• ANSI C37.90.1 • IEC 62052-31
• IEC 61000-4-15 • IEC 62053-22
Benefits • IEC 61000-4-30 • IEC 62053-23
• IEC 61010-1 • IEC 62053-24
• Makes understanding power quality simple which helps
• IEC 61326-1 • IEC 62586
operations personnel avoid downtime and increase
productivity and equipment life • IEC 61557-12 • UL 61010-1
• Makes energy and power quality data immediately • IEC 61850
actionable and relevant to operational and sustainability
goals

Competitive advantages
• Modular, flexible, patented ION™ programmable technology
• Utility grade energy accuracy
• Patented Disturbance Direction Detection
• Third-party, lab-verified compliance with latest PQ standards
• Onboard pass/fail PQ characterization and assessment
according to EN50160 and IEEE519
• Cybersecurity event logging, Syslog protocol, HTTPS, SFTP,
and full control of each communication port
• High-speed impulsive and oscillatory transient detection

Version: 1.0 - 29/08/2019


PLSED309005EN_06
117
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

Main characteristics
• PQ compliance reporting and basic PQ analysis:
–– Monitors and logs parameters according to IEC 61000-4-30 Class A
PB115917

international PQ standards (test methods as per IEC 62586-2).


–– High resolution waveform capture: triggered manually or by event.
Captured waveforms available directly from the meter via SFTP in a
COMTRADE format, and viewable in the meter’s web interface.
–– Generates onboard PQ compliance reports accessible via onboard web
pages:
–– Pass/fail report for IEEE 519 for voltage and current harmonic limits.
–– ITIC (CBEMA) and SEMI curves, with alarm categorization to support
further analyses.
–– NEMA Motor Derating curve.
–– Harmonic analysis:
–– THD and TDD per phase, min/max, custom alarming.
–– Individual harmonic magnitudes and angles on voltage and current,
up to the 63rd harmonic.
PowerLogic™ ION9000 series meter with RD192 display –– Disturbance detection and capture: sag/swell on any current and voltage
channel, alarm on disturbance event, and waveform capture.
–– Patented Disturbance Direction Detection: provides indication of the
captured disturbance occurring upstream or downstream of the meter;
timestamped results provided in the event log, with degree of certainty of
PB115914

disturbance direction.
• Transient detection and capture: events 20 microseconds or longer in
duration on any voltage channel with alarm, event log, and waveform capture.
• PowerLogic ION9000T also provides High-Speed Transient Capture (HSTC)
of voltage events 100 nanoseconds or longer in duration and up to 10,000 V
in magnitude with high-speed and disturbance waveform captures, as well as
per-event statistics on each transient.

• Metering precision:
–– IEC 61557-12 PMD/SD/K70/0.2 and PMD/SS/K70/0.2 3000m (Performance
Measuring and Monitoring devices (PMD)).
–– Class 0.1S accuracy IEC 62053-22, ANSI C12.20 Class 0.1 (active energy).
–– Industry leading Class 0.5S accuracy for reactive energy (IEC 62053-24).
PowerLogic™ ION9000 RD192 remote display –– Cycle-by-cycle RMS measurements updated every ½ cycle.
–– Full ‘multi-utility’ WAGES metering support.
–– Net metering.
–– Anti-tamper protection seals and hardware metrology lock.
PB115918

• Cybersecurity:
–– Security events logging with Syslog protocol support.
–– HTTPS and SFTP secure protocols.
–– Ability to enable or disable any communication port and any protocol per
port.
–– Anti-tamper protection seals and hardware metrology lock.
–– User accounts with strong passwords.

PowerLogic™ ION9000 front view

118 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

• Used with Schneider Electric’s advanced software tools, provides


detailed PQ reporting across entire network:
PB115916

–– EN 50160 compliance report.


–– IEEE 519 harmonic compliance report.
–– IEC 61000-4-30 report.
–– Power quality compliance summary.
–– Energy reports for consumption analysis and cost management.
–– WAGES dashboards and reports.
–– Display of waveforms and PQ data from all connected meters.
–– Onboard web-based waveform viewer.
–– EcoStruxure Power Events Analysis, including alarm management,
PowerLogic ION9000 with panel mounting adapter sequence of events, and root cause analysis.

• Data and event logging:


–– Onboard data and event logging.
–– 2 GB of standard non-volatile memory.
PB115919

–– No data gaps due to network outages or server downtime.


–– Min/max log for standard values.
–– 100 user-definable data logs, recording up to 16 parameters at a 1/2 cycle
or other user definable interval.
–– Continuous logging or snapshot, triggered by setpoint and stopped after
defined duration.
–– Trend energy, demand and other measured parameters.
–– Forecasting via web pages: average, minimum and maximum for the next
four hours and next four days.
–– Advanced time-of-use capability.
–– Security/event log: alarm conditions, metering configuration changes, power
PowerLogic ION9000 front with two option modules outages, firmware download, and user login/logout with timestamp.

• Alarming and control:


–– 50+ definable alarms to log critical event data, trigger waveform recording,
or perform control function.
–– Trigger on any condition, with 1/2-cycle and 1-second response time.
PB115920

–– Combine alarms using Boolean logic enabling customization of alarms.


–– Alarm notification via email.
–– In conjunction with Schneider Electric’s EcoStruxure software, alarms,
software alarms, and alarm frequency are categorized and trended
enabling sequence of events and root cause analyses.

Usability
• Auto-discovery using DPWS (Device Profile Web Services).
• DHCP for automatic IP address configuration.
• Full function web server enables simple web commissioning.
PowerLogic ION9000 bottom with two option modules • Free setup wizard simplifies meter configuration.
• Front panel:
–– Easy to read color graphic display.
–– Simple and intuitive menu navigation with multiple language
interface and support.
• DIN rail mounting options.
• Remote display option.
• Pluggable connectors.

(1) For 50 Hz line frequency; 17µs for 60 Hz line frequency.

Version: 1.0 - 29/08/2019


PLSED309005EN_06
119
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

• Flexible remote communications:


PB115915

–– Multiple simultaneously operating communication ports and protocols allow


interfacing with other automation systems, e.g. waveforms, alarms, billing
data, etc. Data can be uploaded for viewing/analysis while other systems
access real-time information.
–– Supports: Modbus, ION, DNP3, DLMS/COSEM, SNMP, and IEC 61850.
–– Dual port Ethernet: 2x 10/100BASE-TX; supports IPV4 and IPV6; daisy-
chaining capability removes need for additional switches.
–– Create redundant network loop using Rapid Spanning Tree Protocol (RSTP)
and managed Ethernet switches.
–– Secure web interface with HTTPS and TLS 1.2 with support for user-
provided certificates.
–– Customize TCP/IP port numbers and enable/disable individual ports.
–– RS-485 2-wire connection, up to 115,200 baud, Modbus RTU, ION and
DNP3 protocols.
–– Ethernet to serial gateway with Modbus Master functionality, connecting
PowerLogic ION9000 Harmonics display
to 31 unit loads of downstream serial Modbus devices. Also supports
Modbus Mastering over TCP/IP (Ethernet) network.
–– Full function web server with factory and customizable pages to access
real-time and PQ compliance data.
–– Push historical data via email.
–– Advanced network security: Up to 50 configurable user accounts.

• Time synchronization via:


–– Precision network time protocol (PTP) based on IEEE 1588 / IEC 61588.
–– GPS clock (RS-485) or IRIG-B (digital input) to ±1 millisecond.
–– Network Time Protocol (NTP/SNTP).
–– Automatic time synchronization available through Schneider Electric
software server.

Adaptability

• ION™ frameworks are customizable, scalable applications with object-


oriented programming that compartmentalizes functions, and increases
flexibility and adaptability.
• Applications include: access and aggregate data from Modbus devices on
serial port or across the network (Modbus TCP/IP), logging and/or processing
data by totaling, unit conversion or other calculations, applying complex logic
for alarming or control operations, data visualization via web pages.

Standard meter I/O


• 8 digital status/counter inputs with ±1 millisecond timestamp.
• 4 solid state digital outputs (Form A) for energy pulsing, interfacing with other
systems or control.
• 2 Form C relay outputs for control applications.

Modular I/O options


• Optional expansion modules.
• Up to 4 modules per meter.

Option modules include:


• Digital module:
–– 6 digital status/counter inputs.
–– 2 Form C relay outputs, 250 V AC, 8 A.
• Analog module:
–– 4 analog inputs (0-20 mA, 4-20 mA; 0-30 V).
–– 2 analog outputs (0-20 mA, 4-20 mA; 0-10 V) for interfacing with building
management sensors and systems.

120 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

ION9000 series Feature guide


ION9000 ION9000T
General
Use on LV, MV, and HV systems b b
Current accuracy: 0.1 % reading b b
Voltage accuracy: 0.1 % reading b b
Active energy accuracy: 0.1 Class b b
Number of samples/cycle or sample frequency: 1024 b b
High-Speed Transient Capture: 10 MHz b
(200 k for 50 Hz, 167 k for 60 Hz)
Instantaneous rms values
Current, voltage, frequency b b
Active, reactive, apparent power: Total and per phase b b
Power factor: Total and per phase b b
Energy values
Active, reactive, apparent energy b b
Settable accumulation modes b b
Demand values
Current: Present and max. values b b
Active, reactive, apparent power: Present and max. values b b
Predicted active, reactive, apparent power b b
Synchronization of the measurement window b b
Setting of calculation mode: Block, sliding b b
Power Quality measurements
Harmonic distortion: Current and voltage b b
Individual harmonics: via front panel and web page: 63 b b
via EcoStruxure™ software: 511
Waveform capture b b
Detection of voltage swells and sags b b
Fast acquisition: 1/2 cycle data b b
EN 50160 compliance checking b b
Customizable data outputs (using logic and math functions) b b
IEEE 519 compliance checking b b
Data recording
Min/max of instantaneous values b b
Data logs b b
Event logs b b
Trending/forecasting b b
SER (Sequence of event recording) b b
Time stamping b b
GPS synchronization (± 1ms) b b
Memory: 2000 MB b b
Display and I/O
Front panel display, 2 options: 96 mm & 192 mm b b
Pulse output: 2 b b
Digital or analog inputs(max): 32 digital, 16 analog b b
Digital or analog outputs (max, including pulse output): 4 b b
digital, 10 relay, 8 analog
Communication
RS-485 port(s): 2 b b
Ethernet port(s): 2x 10/100BASE-TX, RJ45 connector, b b
CAT5/5e/6/6a cable
Serial port protocols (Modbus, ION, DNP3, DLMS/COSEM) b b
Ethernet port protocols (Modbus, ION, DNP3, DLMS/COSEM, b b
IEC 61850)
Ethernet gateway b b
Alarm notification via email b b
HTTP/HTTPS web server with waveform viewer b b
SNMP with custom MIB and traps for alarms b b
SMTP email b b
PTP and NTP time synchronization b b
SFTP file transfer b b

Version: 1.0 - 29/08/2019


PLSED309005EN_06
121
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

ION9000 series
Technical specifications
ION9000 ION9000T

Electrical characteristics
Type of measurement True rms to 1,024 samples per cycle b b
High-speed transient detection, 10 MHz, 10 kV b
Measurement accuracy Current & voltage Class 0.1 as per IEC 61557-12 b b
Active Power Class 0.1 as per IEC 61557-12 b b
Power factor Class 0.5 as per IEC 61557-12 b b
Frequency Class 0.02 as per IEC 61557-12 b b
Active energy Class 0.1S IEC 62053-22 b b
Class 0.1 IEC 61557-12
Class 0.1 ANSI C12.20

Reactive Energy Class 0.5S IEC 62053-24 b b


Display refresh rate HMI display updated once per second; data refresh rate 1/2 cycle b b
or 1 second

Input-voltage Specified accuracy 57 - 400 V L-N / 100 - 690 V L-L b b


characteristics voltage

Impedance 5 MW per phase b b


Specified accuracy 42 to 69 Hz b b
frequency (50/60 Hz nominal)

Limit range of operation 20 to 450 Hz b b


- frequency

Input-current Rated nominal current 1 A (0.1S), 5 A (0.1S); current class 2, 10, 20 A (0.1 ANSI) b b
characteristics
Specified accuracy Starting Current: 1 mA (no accuracy) b b
current range Accurate Range: 10 mA - 20 A

Permissible overload 500 A rms for 1.0s b b


Impedance 0.0003 W per phase b b
Burden 0.01 VA max at 5 A b b
Power supply AC 90-480 V AC ±10 % (50/60 Hz ±10 %) 90-120 V AC ±10% (400 Hz) b b
AC/DC
DC 110-480 V DC ±15 % b b
Ride-through time 100 ms (5 cycles at 50/60 Hz) typ., 120 V AC b b
(Values for meters with 400 ms (20 cycles at 50/60 Hz) typ., 240 V AC
no optional accessories) 1,200 ms (60 cycles at 50/60 Hz) typ., 480 V AC

Burden Typical: 16.5 W / 38 VA at 480 V (50/60 Hz) b b


Fully optioned: max. 40 W / 80 VA at 480 V (50/60 Hz).

Input/outputs Meter base Only 8 digital inputs (30 V AC/60 V DC) b b


4 Form A (KY) solid state digital output (30 V AC/60 V DC, 75 mA)
2 Form C relays (8 A at 250 V AC, 5 A at 24 V DC)

Optional Digital - 6 digital inputs (30 V AC / 60 V DC) wetted + 2 Form C relay b b


outputs (250 V AC, 8 A)

Analog - 4 analog inputs (0-20 mA, 4-20 mA, 0-30 V DC) + 2 b b


analog outputs (0-20 mA, 4-20 mA, 0-10 V DC).

Mechanical characteristics
Weight DIN rail mount meter 1.5 kg b b
IO modules 0.140 kg
Touchscreen display 0.300 kg

IP degree of protection IP 65, UL type 12: Panel mount and touchscreen display, front. b b
IP 30: Panel mount rear, DIN rail mount, I/O modules.
Excellent quality ISO 9001 and ISO 14000 certified manufacturing. b b

Dimensions Panel mount 160 x 160 x 135.3 mm b b


DIN rail mount meter 160 x 160 x 135.3 mm b b
Color remote display 197 x 175 x 27.5 mm touchscreen b b
(2 options) 96 x 96 x 27 mm pushbutton
I/O modules 90.5 x 90.5 x 22 mm b b
Touchscreen display(s) 192 mm and 96 mm b b

(1) Consult the ION7550 / ION7650 installation guide for complete specifications. (2) IEC 62051-22B with serial ports only.

122 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

ION9000 series
Environmental conditions ION9000 ION9000T
Operating temperature -25 to 70 ºC b b
Remote Display Unit -25 to 60 ºC b b
Storage temperature -40 to 85 ºC b b
Humidity rating 5 to 95 % non-condensing b b

Installation category III b b


Operating altitude (maximum) 3,000 m above sea-level b b
Electromagnetic compatibility
EMC standards IEC 62052-11, IEC 61326-1, IEC 61000-6-5 b b
Immunity to electrostatic discharge IEC 61000-4-2 b b
Immunity to radiated fields IEC 61000-4-3 b b
Immunity to fast transients IEC 61000-4-4 b b
Immunity to surges IEC 61000-4-5 b b
Immunity to conducted IEC 61000-4-6 b b
disturbances

Immunity to power frequency IEC 61000-4-8 b b


magnetic fields

Immunity to conducted CLC/TR 50579 b b


disturbances, 2-150kHz

Immunity to voltage dips & IEC 61000-4-11 b b


interruptions

Immunity to ring waves IEC 61000-4-12 b b


Conducted and radiated emissions EN 55011 and EN 55032 Class B, FCC part 15 Class B, ICES-003 Class B b b
Surge withstand Capability (SWC) IEEE/ANSI C37.90.1 b b
Safety
Safety Construction IEC/EN 61010-1 ed.3, CAT III, 400 V L-N / 690 V L-L, UL 61010-1 ed.3 and CSA-C22.2 No. b b
61010-1 ed.3, CAT III, 347 V L-N / 600 V L-L, IEC/EN 62052-31, protective class II.

Communication
Ethernet to serial line gateway Communicates directly with up to 31 serial devices. b b
Web server Customizable pages, new page creation capabilities, HTML/XML compatible. b b
Serial port RS-485 2x, Baud rates of 2,400 to 115,200, pluggable screw terminal connector. b b
Ethernet port(s) 2x 10/100BASE-TX, RJ45 connector, CAT5/5e/6/6a cable. b b
Protocol HTTPS, SFTP, SNMP, SMTP, DPWS, RSTP, PTP, NTP/SNTP, GPS, Syslog, DHCP, IPv4, IPv6. b b
Firmware characteristics
High-speed data recording Down to 1/2 cycle interval recording, stores detailed characteristics of disturbances b b
or outages. Trigger recording by a user-defined setpoint, or from external equipment.

Harmonic distortion Up to 63rd harmonic (511th via Schneider Electric EcoStruxure software) for all b b
voltage and current inputs.

Sag/swell detection Analyze severity/potential impact of sags and swells: magnitude and duration data suitable for b b
plotting on voltage tolerance curves per phase triggers for waveform recording.

Disturbance direction detection Determine the location of a disturbance more quickly and accurately by determining b b
the direction of the disturbance relative to the meter. Results are captured in the
event log, along with a timestamp and confidence level indicating level of certainty.

Detection and capture of transients As short as 20 μs at 50 Hz (17 μs at 60 Hz) b b


High-speed transient capture Detection and capture of high-speed impulsive and oscillatory transients as short as 100 ns in b
duration and up to 10 kV in magnitude. (PowerLogic ION9000T).

Instantaneous High accuracy of standard speed (1s) and high-speed (1/2 cycle) measurements, b b
including true rms per phase and total for: voltage, current, active power
(kW),reactive power (kvar), apparent power (kVA), power factor, frequency, voltage
and current unbalance, phase reversal.

Load profiling Channel assignments (1600 channels via 100 recorders) configurable for any b b
measurable parameter, including historical trend recording of energy, demand,
voltage, current, power quality, or any measured parameter. Trigger recorders based
on time interval, calendar schedule, alarm/event condition, or manually.

Trend curves Historical trends and future forecasts to better manage demand, circuit loading, and other b b
parameters. Provides average, min, max, and standard deviation every hour for last 24 hours,
every day for last month, every week for last 8 weeks and every month for last 12 months.

Version: 1.0 - 29/08/2019


PLSED309005EN_06
123
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

ION9000 series
Firmware characteristics (cont.) ION9000 ION9000T
Waveform captures Simultaneous capture of voltage and current channels, sub-cycle disturbance captures of b b
180-cycles @ 1,024 samples/cycle to 7,200-cycles @ 16 sample/cycle, retriggerable.

High-speed transient waveform Simultaneous capture of voltage channels, impulsive and oscillatory transient capture b
captures of up to 1-cycle @ 200 k samples per cycle (50 Hz) along with coincidence disturbance
waveform capture (PowerLogic ION9000T).

Alarms Threshold alarms: adjustable pickup and dropout setpoints and time delays, numerous activation b b
levels possible for a given type of alarm, user-defined or automatic alarm threshold settings, user-
defined priority levels (optional automatic alarm setting).

Advanced Time of Use (TOU) 4 seasons; 5 different day types: weekend, weekday, and holiday; up to 4 tariffs per day type. b b
Advanced network security Up to 50 users with unique access rights. Perform resets, time sync, or meter b b
configurations based on user privileges.

Memory 2,000 MB. b b


Firmware update Update via the communication ports. b b
Display characteristics
96 mm pushbutton display 320 x 240 (1/4 VGA) color LCD, configurable screens, 5 buttons and 2 LED indicators b b
(alarm and meter status).

192 mm touchscreen display 800 x 480 pixels, 177.8 mm (7”) Color LCD, +/- 85 degree view angle, sunlight readable, b b
dual capacitive touch, usable when wet or through Class 0 lineman gloves, impact
resistant to 5 joules, IP65 rating.

Languages English, French, Spanish, Russian, Portugese, German, Italian, Chinese. b b


Notations IEC, IEEE. b b

ION9000 Commercial reference numbers


Commercial reference
Description
number
METSEION92030 ION9000 meter, DIN mount, no display, hardware kit

METSEION92040 ION9000 meter, DIN mount, 192 mm display, B2B adapter, hardware kit

METSEION95030 ION9000T meter, HSTC, DIN mount, no display, hardware kit

METSEION95040 ION9000T meter, HSTC, DIN mount, 192 mm display, B2B adapter, hardware kit

METSEPM89RD96 Remote display, color LCD, 96 x 96 mm

METSERD192 Remote display, color touchscreen, 192 x 192 mm

METSEPM89M2600 I/O module, 2 relay outputs, 6 digital inputs

METSEPM89M0024 I/O module, 2 analog outputs, 4 analog inputs

METSE9HWK ION9000 meter hardware kit – plugs, terminal guards, spare grounding screw, DIN clips

METSERD192HWK RD192 remote display hardware kit

METSE9B2BMA ION9000 B2B (back to back) mounting adapter

METSE9USBK ION9000 USB cover hardware kit

METSE9CTHWK ION9000 current input hardware kit – terminal screws and covers

METSE7x4MAK ION7x50 mounting adapter kit

Contact your Schneider Electric representative for complete ordering information.

124 Version: 1.0 - 29/08/2019


PLSED309005EN_06
ADVANCED METERING DIMENSIONS AND CONNECTION

ION9000 series
ION9000 meter dimensions ION9000 mounting template

PB119714_m
PB119707

ION9000 back-to-back (B2B) dimensions

PB119705

ION9000 192 mm display dimensions


PB119712_m

ION9000 96 mm display dimensions


PB119713_m

Please refer to ION9000 Series Meter Installation Sheet for accurate and complete information on the installation of this product.

Version: 1.0 - 29/08/2019


PLSED309005EN_06
125
ADVANCED METERING FUNCTIONS AND CHARACTERISTICS

ION9000 series
ION9000 meter DIN rail dimensions ION7x50 mounting adapter dimensions
PB119706

PB119714
ION9000 meter click installation
PB119708

126 Version: 1.0 - 29/08/2019


PLSED309005EN_06