100% found this document useful (2 votes)
225 views5 pages

Compressor Choke: by TMI Staff & Contributors On August 27, 2019

Choke occurs when the process does not create enough restriction to the compressor flow and the compressor operates at its maximum flow for a given performance level. Control systems are available to protect the compressor from surge, but not always from choke. Investigation of several catastrophic failures using diagnostics tools point to choke (not surge) as the root cause of the failure due to fatigue of a rotating blade or fixed vane. Operation in deep choke, especially of axial compressors.

Uploaded by

Tusar Kole
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
225 views5 pages

Compressor Choke: by TMI Staff & Contributors On August 27, 2019

Choke occurs when the process does not create enough restriction to the compressor flow and the compressor operates at its maximum flow for a given performance level. Control systems are available to protect the compressor from surge, but not always from choke. Investigation of several catastrophic failures using diagnostics tools point to choke (not surge) as the root cause of the failure due to fatigue of a rotating blade or fixed vane. Operation in deep choke, especially of axial compressors.

Uploaded by

Tusar Kole
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

COMPRESSOR CHOKE

By  TMI Staff & Contributors  · On August 27, 2019

THE CATASTROPHIC EFFECT OF CHOKE IN


AXIAL COMPRESSORS AND PREVENTION MEASURES
BY LEYDEN LOPEZ

Axial compressors are used in large-scale processes where a significant amount of gas is
required at a relatively low pressure. Typical applications are at the oil refinery’s fluid catalytic
cracking unit (FCCU) as the main air blower, at the steel-mill as the blower for the blast furnace
or as part of an industrial or aeroderivative gas turbine. Centrifugal compressors are more
commonly used due to their versatility: they can compress a wide range of flows to a high
discharge pressure. The stable operation of axial and centrifugal compressors is limited by surge
and choke. Surge is a violent flow reversal that occurs when the process restricts the compressor
flow below a certain minimum value.

Choke occurs when the process does not create enough restriction to the compressor flow and
the compressor operates at its maximum flow for a given performance level. Control systems are
available to protect the compressor from surge, but not always from choke. Investigation of
several catastrophic failures using diagnostics tools point to choke (not surge) as the root cause
of the failure due to fatigue of a rotating blade or fixed vane. Operation in deep choke, especially
of axial compressors during unloaded operation, therefore, should be avoided. The effect of
choke in centrifugal compressors is generally overlooked and is typically of no major concern.
This is in great part due to the natural shape of the performance curve that represents a
significant change in flow from the limit of surge to the limit of choke (Figure 1).

In axial compressors, however, this distance is significantly less (Figure 2). The more stages a
compressor has, the higher the pressure ratio but the smaller the operational margin between
surge and choke regions. Figure 2 shows the performance curves of a 12-stage axial
compressor. The operational margin of a performance curve is significantly less than the one of a
6-stage centrifugal compressor shown in Figure 1.

OEMs are not always clear about the precise location of the choke line as most attention is given
to the surge line. The same mistake is transferred to control systems, which focus exclusively on
protection from surge. However, ignoring the effect of choke in axial compressors has cost
refinery owners months of production loss due to the catastrophic failure of the axial main air
blower (MAB), one the most critical pieces of machinery in the refinery. Compressor choke or
stonewall is an unstable operating condition, which occurs when the compressor is operating at
low discharge pressure and high f low rate. This leads to increased gas velocity in the
compressor.

The increase in gas velocity occurs until it reaches sonic velocity or resonance at the blade throat
(Mach 1). At this point, no more flow can pass through the compressor, causing high frequency
and low amplitude vibration of the rotor blades or stator vanes. During choke, the flow channels
between blade rows may experience blockage effects.
Choke can occur at any performance level, i.e., speed or position of the variable stator vanes
(VSV) for a constant speed machine. Although the choke increases with the performance level,
long-term operation even at low-performance level in a deep-choke condition can be damaging
due to its low visibility and cumulative effect.

Choke is difficult to detect by conventional vibration monitoring systems. When a compressor


transits back and forth from the stable area to the choke area, a minor change in noise frequency
can sometimes be heard specially at higher performance levels. Currently, no dedicated
instruments are used for choke detection. Therefore, an axial compressor can be operating in a
deep choke condition for a long period of time during unload condition at low performance levels
(low speed or closed VSV position) without being noticed by the machinery operator.

The opposite is true when the compressor is operating in surge condition. The negative impact
on the process and the potentially damaging effects of compressor surge are clearly observable.
The cumulative effect of choke means that the most vulnerable part (rotor blade or stator vane)
has a limited number of cycles prior to failure by fatigue. Material analysis of failed rotor blades
has concluded that the initiation points of fracture related to operation in deep choke are located
at the blade’s suction side (convex or curved side).

Fracture begins to develop causing a continuous decline in the blade’s moment of resistance,
and bending stresses increase permanently until they exceed material yield strength. Fracture
eventually occurs during operation at high load. Therefore, choke can easily go unnoticed for
years until it produces enough cumulative cycles leading to component failure by fatigue. In the
case of an FCCU, operation in choke condition typically occurs during the startup of the MAB
prior to or during the dry-out period. Since the process is not yet ready to accept the full amount
of air, no attention is given to the fact that the compressor requires some back-pressure to
operate safely. Consequently, no pressure resistance is created from the process side. Further,
the anti-surge valve may remain open.

The MAB, therefore, is accumulating a significant number of additional choke cycles that will
eventually lead to failure. In many cases, catastrophic failure will not take place for ten or even
twenty years of apparently stable operation after many apparently successful startups. The
cumulative effect of choke-induced fatigue gradually leads to the failure of blower components.
This is most likely to occur when the MAB is operating at a peak high load that is far away from
the surge and choke regions. Without advanced diagnostic tools and proper analysis, damage is
likely to be attributed to severe surging.

In industrial gas turbine applications, investigation has pointed to choke as the cause of
premature fracture failure of blades in the first row of the axial compressor due to long and
unstable operation of the combustion chamber during startup periods. Choke conditions
Operators should be aware of the various operating conditions under which a compressor is
likely to get into a choke condition such as during failure (open) of the anti-surge valve, or when
the compressor is undersized for the desired operating conditions.
During start-up and under unloaded operation, too, choke can occur when the
anti-surge valve is opened too much or for too long, and no back-pressure is created by the
process. If the anti-surge valve is oversized, high travel limitation (clamp) must be established in
the controller to make sure the compressor operating point enters the stable operating envelope
as soon as it starts and remains there during operation in unload condition. It is vital to
avoid compressor operation in a deep choke condition from the beginning of
startup (Figure 3).

Another choke condition takes place during loaded operation in combination


with excessive opening of the anti-surge valve due to manual operation or by valve low travel
limitation (clamp) set by the operator. The operator sometimes applies low clamping during
startup while the process is stabilizing to add extra cushion and prevent surge or fast opening of
the antisurge valve by the control system.
In centrifugal compressors, low clamping wastes energy. But in axial compressors, it may also
push the blower into the choke area (due to the narrow operating area between surge and
choke). Therefore, clamping must be avoided or used with special care with axial compressors.

One further choke condition should be noted: In compressors operating in parallel, when one
compressor trips, the natural response of a load sharing control system is to increase the
performance of the running compressor to compensate for the loss. However, if process
resistance remains unchanged, the running compressor will be pushed into the choke area.
To avoid such conditions, certain control measures should be implemented:
• Install an anti-choke valve immediately downstream of the anti-surge blowoff/recycle line and
set up proper antichoke control, which must be independent from the anti-surge controller.
Separate transmitters must be used as the distortion of a shared transmitter signal may have
conflicting effects on the anti-surge and anti-choke controllers
• Make sure the process is always ready to provide enough back-pressure for
the compressor as soon as it is started. For example, place an initial set point of 10-15 psig at
the FCCU regenerator. The slide valves should also be kept closed at the mechanical stop to
help creating back-pressure. In the case of power recovery trains, the expander inlet and bypass
valves can stay closed during startup of the train. If an anti-choke valve is present, start the
compressor with that valve initially closed, then slowly ramp it open
• Perform a choke test in addition to a surge test to determine the choke line and establish a
choke control line. Make sure the compressor can operate safely in the area close to the
expected choke limit. A portable accelerometer can be used to determine if the axial blower is
operating in a choke condition. In the author’s experience, radial vibration or axial displacement
do not increase in a deep choke condition. An accelerometer placed in the casing
near the blower inlet has shown a clear acceleration peak when operating in a choke condition.
At higher performance levels, choke can also be perceived by
a variation of the normal operating sound
• Graphically illustrate in the HMI the exact location of the choke line, surge line and control lines.
As choke is not noticeable (unlike surge), it is
vital that it be graphically shown on a real-time compressor
map
• When operation near choke is detected, the control system should generate an alarm. In the
absence of a choke valve, the operator may be able
to apply corrective measures, such as increasing the regenerator
pressure
• Properly size and test the anti-surge valve to make sure it does not allow for operation in choke
when 100% open in an unloaded condition. The
selection criteria for the capacity of anti-surge valves may be different for axial compressors
compared to centrifugal
• Have an advanced diagnostic tool that stores high resolution trends and events so catastrophic
damage can be correctly attributed
• It is recommended that vendors develop and install an additional signal to the vibration system,
such as an accelerometer from the compressor
case to generate an alarm and trip due to operation in choke condition for a certain period of
time.
Leyden Lopez is Director of Leyden Turbomachinery Corporation of Houston, TX, providing
commissioning and consulting services on turbomachinery controls. For more information, visit
www.leydentcs.com

You might also like