WIND LOAD CALCULATION
LOCATION: ILIGAN CITY
TOPOGRAPHY: FLAT
HEIGHT: 7.5
NSCP: 2015
EXPOSURE CATEGORY: C
IMPORTANCE FACTOR: 1
OCCUPANCY CATEGORY: RESIDENTIAL
BASIC WIND SPEED FORMULA
qz=47.3x10^-6KzKztKdV^2Iw
Parameter Value Unit
Zone 3 n/a
V 125 Kph
Kz 0.75 n/a
Kzt 1 n/a
Kd 0.85 n/a
Iw 1.15 n/a
G 0.85 n/a
Pressure Value Unit
qz 0.541825195 kPa
Velocity Pressure
Variable Description
q=qz For windward Wall
q=qz For Leeward Wall
qf=qh For Enclosed Building
G Gust Effect Factor
Ch External Pressure Coefficient
Gcpi Internal Pressure Coefficient
p=qGCp-qf(Gcpi)
Enclosure Classification Gcpi
Open Buildings 0
Partially Enclosed Buildings 0.55
Enclosed Buildings 0.18
Wall Pressure Coefficient, Cp
Surface L/B Cp Use with
Windward All Values 0.921 qz
Leeward 0-1 -0.674 qh
2 -0.325
>4 -0.236
Side All Values -0.789 qh
Pressure Value Unit
Windward 0.88 kPa
Leeward -0.568 kPa
Wind Overturning Moment
Moment Value Unit
Moment 9.23 kN-m