66e User Instructions PDF

This document provides instructions for operating an AuditGard 66e high security electronic lock. It summarizes the lock's features, including multiple user codes, time delay functionality, acoustic and visual signals, low battery warnings, and optional features like dual authorization, alarm integration, and audit logging. The summary also outlines procedures for common actions like opening the lock, changing codes, enabling/disabling user codes, and checking the lock's audit log.

Uploaded by

SXHXC
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
246 views4 pages

66e User Instructions PDF

This document provides instructions for operating an AuditGard 66e high security electronic lock. It summarizes the lock's features, including multiple user codes, time delay functionality, acoustic and visual signals, low battery warnings, and optional features like dual authorization, alarm integration, and audit logging. The summary also outlines procedures for common actions like opening the lock, changing codes, enabling/disabling user codes, and checking the lock's audit log.

Uploaded by

SXHXC
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

AuditGard 66e

High Security Lock for Safes & Vaults

User Operating Instructions


Standard Specification
With additional instruction for Dual Mode, Alarm Signals and Time Delay Override
Available users and default codes Time delay
Time Delay is a feature requiring a period of time to
User User ID Default Code elapse before the lock system can be opened, to
Master N/A 9-8-7-6-5-4-3-2 prevent a user being forced to open the lock
Manager N/A 1-2-3-4-5-6 immediately.
Users 2-9 2-9 Deleted – Must be added The Time Delay period can be set from 1 – 99 minutes
by the Manager The Open Window is the period of time after time delay
has expired during which the lock can be opened which
Default codes must be changed immediately. The can be set from 1-19 minutes.
master code contains 8 digits, all other codes contain 6
digits. Low battery warning
If the battery is running low, repeated beeping during
Acoustic and visual signals opening will indicate the need to change the battery.
The lock system will indicate status with beeps and LED
Penalty
flashes on the keypad
Entry of 4 consecutive incorrect codes results in a 5
minute penalty - all lock functions are disabled. During
Signal Indication
Short beep & LED flash Button pressed correctly
penalty, the LED flashes at 10 second intervals and a
Double beep & LED flash Code or function entered key press will result in 3 beeps. After the penalty has
correctly expired, 2 further consecutive incorrect codes will
Triple beep & LED flash Code or function entered initiate the penalty. Once a correct code is entered, the
incorrectly
penalty trigger resets to 4 wrong tries.
5 beeps on a key press Remote disable is active
LED flash every second The lock is in time delay
Check user status
LED flash twice per second The lock is in the open window
and beep every 10 The status of users, whether enabled, disabled or
seconds deleted may be audited using the keypad.
LED flash every 10 The lock is in penalty
seconds Optional Features Available On Request
Repeated beeping and Low battery warning
flashing during opening Audit
An audit can be taken of the last 512 lock events,
Command Keys showing opening activity and other operations. The
audit shows time and date information. To take an audit,
All of the functions available to the master, manager a PC is required along with software and a cable
and users are accessible using command keys. To use interface kit, items sold separately.
a command key, enter a valid code and hold down the
last digit until 2 sets of double beeps have sounded and Dual mode
the LED stays on. Press the relevant command key and The lock system can be set up so that 2 codes are
follow the remaining instruction. required to open the lock and carry out manager special
functions.
Key Function
0 Change Code Alarm signals
1 Add a user / enable a disabled user / check user The lock can be set up so that a silent signal is sent to
status
2 Disable a user an alarm system when a duress code is entered, in
3 Delete a user addition to one of the following options:
7 Download an audit  When an input signal is received from an alarm
9 Enter time delay values system, the lock is disabled from opening.
 When an input signal is received from an alarm
Standard Features
system, the lock is disabled from opening, and any
command functions are disabled.
Codes & Users An alarm box, sold separately, is required to interface
with the alarm system.
The master code holder can:
 Change Code  Audit the lock Time delay override
User 9 is able to override time delay. This feature is
The manager code holder can:
intended for cash carriers who may require immediate
 Open the lock  Change code
 Add, enable, disable  Audit the lock
access to the safe.
and delete users  Set time delay values Dallas Key / eKey / Dual Token
 Check user status
Users must insert a Dallas key into the reader on the
There are 8 user codes numbered 2-9. Users can: keypad in addition to entering their code to open the
 Open the lock  Change code lock system. This feature requires eKeys which are sold
separately.
To open the lock Manager Functions continued…

Enter a valid 6 digit code. Within 4 seconds, turn the To disable a user
safe handle and/or turn the keypad. A user can be temporarily disabled without deleting their
code
To close the lock
Enter the manager code and hold down the last digit
until 2 sets of double beeps sound and the LED stays
Turn the safe handle and/or turn the keypad.
on.
To open the lock when time delay is active Press 2, a double beep will sound
Enter the user ID number 2-9. A single beep will sound
Enter a valid 6 digit code. Wait for the time delay period and the LED will turn off.
to elapse.
The open window will be indicated with LED flashes To enable a user
twice every second, and a beep every 10 seconds If a user has been disabled, their code can be enabled
Enter a valid 6 digit code. Within 4 seconds, turn the Enter the manager code and hold down the last digit
safe handle and/or turn the keypad. until 2 sets of double beeps sound and the LED stays
on.
To change code Press 1, a double beep will sound
Enter the user ID number 2-9. A single beep will sound
Codes should always be changed and tested with the and the LED will turn off.
safe or vault door open, with the bolt in the locked
position. To check user status
Enter the old code and hold down the last digit until 2 Enter the manager code and hold down the last digit
sets of double beeps sound and the LED stays on until 2 sets of double beeps sound and the LED stays
Press 0, a double beep will sound on
Enter the new code, a double beep will sound Press and hold 1 until 2 sets of double beeps sound
Enter the new code again to confirm, a double beep will and the LED stays on
sound Press each user ID 2-9 in turn. The signals below
Test that the new code works whilst the door is open. indicate the user’s status
New codes which differ from the existing code by only 1  A single beep - user is active
digit will not be accepted  A double beep - user is disabled
 A triple beep - user is deleted
Manager Functions
Press 0 to exit
To add a user
If a user is deleted, the user can be activated with a To audit the lock
new code. Full technical instructions for taking an audit are
Enter the manager code and hold down the last digit available with the audit software. The command
until 2 sets of double beeps sound and the LED stays required on the lock is:
on Enter the manager code and hold down the last digit
Press 1, a double beep will sound until 2 sets of double beeps sound and the LED stays
Enter a user ID number from 2-9. A double beep will on
sound (If a single beep sounds and the LED turns off, Press 7 to start the audit transmission.
that user is already activated and can be disabled or
deleted) To enter time delay values
The user should enter their 6 digit code, a double beep Enter the manager code and hold down the last digit
will sound. until 2 sets of double beeps sound and the LED stays
The user should enter their 6 digit code again to on.
confirm, a double beep will sound. Press 9, a double beep will sound
The user should check the code to ensure correct entry Enter 2 digits to indicate the time delay period 01-99
whilst to door is open. minutes. Enter 2 digits to indicate the open window
period 01-19 minutes
To delete a user A double beep will sound
If a user’s code is no longer required it can be deleted Re-enter the 4 digits to confirm
Enter the manager code and hold down the last digit A double beep will sound to confirm that the values
until 2 sets of double beeps sound and the LED stays have been set
on.
Press 3, a double beep will sound
Enter the user ID number from 2-9
A single beep will sound to confirm deletion of the user.
Manager Functions continued… Optional Feature – Alarm signals

To enter a duress code


To increase time delay values
If the feature has been enabled, a duress code can be
To increase time delay values follow the steps in “To
entered which will open the lock and also send a silent
enter time delay values”
signal to the alarm system to notify others that the lock
is being opened under duress.
To decrease or remove time delay values
The duress code is the user’s normal code, but the last
To decrease or remove time delay values, the operation
digit should be decreased or increased by 1, for
must be performed during the open window before the
example:
user or manager code is entered. To decrease, follow
the steps in “To enter time delay values”  Normal code: 1-2-3-4-5-6
To remove:  Duress code: 1-2-3-4-5-5 or 1-2-3-4-5-7
Enter the manager code and hold down the last digit Signals if remote block is active
until 2 sets of double beeps sound and the LED stays If the lock system is connected to an alarm and an input
on. signal is received, the lock will beep 5 times either when
Press 9, a double beep will sound a key is pressed or after entry of a valid code.
Enter 00 to indicate the time delay period should be 0
minutes. Enter 00 to indicate the open window should Optional Feature – Time Delay Override
not be operational.
If the feature has been enabled, User number 9 is able
A double beep will sound. Re-enter the 4 digits to
to override time delay. User 9 can only be added by the
confirm. A double beep will sound to confirm. The open
manager if time delay is not active or during the open
window will continue.
window if time delay is active.
Master Functions Troubleshooting

Prior to performing a master function, the master code Any key press results in a triple beep
holder must press and hold 0 until a double beep The lock is in penalty. The LED will flash every 10
sounds to indicate that an 8 digit code is to be used. seconds. Wait for the 5-minute penalty to elapse to
enter a valid code.
To change code
A triple beep sounds
Press and hold 0
The code or function has not been entered correctly re-
Follow the user change code procedure
enter.

To audit the lock If a mistake is made during code or function entry


Full technical instructions for taking an audit are Wait 30 seconds and repeat the function
available with the audit software. The command
A key does not beep when pressed
required on the lock is:
The battery may be depleted. Consult the safe or vault
Press and hold 0
supplier for information on changing batteries.
Enter the master code and hold down the last digit until
2 sets of double beeps sound and the LED stays on Repeated beeps and flashes during opening
Press 7 to start the audit transmission The battery is running low. Consult the safe or vault
supplier for information on changing batteries.
Optional Feature – Dual Mode
The safe or vault door does not open
If the lock system is otherwise operating normally, there
If the lock has been supplied in dual mode, user 2 is may be a mechanical fault with the safe. Contact a safe
installed with the default code 2-2-2-2-2-2 engineer.
To open the lock
User Record
Two valid codes must be entered to open the lock, one
of which can be a manager code. Master
Manager
To open the lock when time delay is active 2
Two valid codes are required to start time delay, and to 3
open the lock during the open window. User 9 may 4
override time delay after another valid code has been 5
entered. 6
7
To perform a manager function 8
A valid user code must be entered before following the 9
standard manager function procedure.