Display Elements
Display Elements
4.2 Interfaces
Operating and Fig. 4-1 shows the position of the operating and display elements on the front
display elements panel.
Descrip-
Type Meaning
tion
RESET Triggering a hardware reset to reset the control and drive
Button
(S1) followed by a complete restart.
NCK commissioning switch
Position 0: Normal operation
Rotary
S3 Position 1: Clear and reset NCK
switch
Position 2: Software update NCK of memory card
Position 3...7: not used
PLC mode switch
Position 0: PLC-RUN
Rotary
S4 Position 1: PLC-RUN-P
switch
Position 2: PLC-STOP
Position 3: MRES
green LED +5V: lit when the supply voltage is within the tolerance
range.
red LED NF: lit if the NCK or PLC watchdog
has responded
LEDs
red LED SF: lit in the event of drive error. No longer lit following
(left row)
system power up in the fault-free condition.
yellow LED CB: lit when data transmission is in progress
via the MPI interface.
yellow LED P24: lit on failure of the 24V power supply
green LED PR: PLC-RUN state
LEDs red LED PS: PLC-STOP state
(right red LED PF: lit on PLC error
row) yellow LED PFO: PLC-FORCE state
yellow LED RST: lit briefly on reset.
H3 7 segment Software-assisted output of test and diagnostics messages
DAC measuring
sockets
DAC 1 DAC 2
DAC 3 Ground