S5000 Gas Monitor
Specifications
XCEll H2S <23 sec. +/- 5% <1% full scale RS-485 OutPut Modbus RTU, suitable for linking up to 128 units
or up to 247 units with repeaters
XCEll CO <9 sec. +/- 5% <1% full scale
BAuD RAtE 2400, 4800, 9600, 19200, 38400, 115200
XCEll O2 <15 sec. ≤ +/- 0.3% Vol 0.2% Vol
HARt HART 7, HART device description language
APPROvAlS Class I, Div 1&2, Groups A, B, C & D, T5/T4; available
ClASSIfICAtIOn Class II, Div 1&2, Groups E, F & G, T6; Class III
Type 4X, IP66 fAultS MOnItORED Low supply voltage, RAM checksum error, flash
US Zones checksum error, EEPROM error, internal circuit
Class I, Zone 1 AEx db IIC T5 Gb error, relay, invalid sensor configuration, sensor
Class I, Zone 2 AEx nA nC IIC T4 Gc faults, calibration faults, analog output
Class II, Zone 21 AEx tb IIIC T85°C Db mismatch fault
Canadian Zones/ATEX/IECEx CABlE 3-wire shielded cable for single sensor and
Ex db IIC T5 Gb REquIREMEntS 4-wire shielded cable for dual sensor
Ex nA nC IIC T4 Gc configurations. Accommodates up to 12 AWG
Ex tb IIIC T85°C Db Refer to manual for mounting distances.
(see manual for complete CSA listings)
DIMEnSIOnS
WARRAnty S5000 transmitter: 2 years
XCell Sensors: 3 years 6.37 4.25
2X R.155 1.85
Passive Comb, Passive MOS, IR400: 2 years
APPROvAlS CSA, ATEX, IECEx, CE Marking
Complies with C22.2 No. 152, FM 6320,
5.38 6.00
IEC/EN 60079-29-1, ANSI/ISA 12.13.01.
7.62
Suitable for SIL 2 2.70
EnvIROnMEntAl SPECIfICAtIOnS
OPERAtInG Passive Comb (sintered): -40°C to +70°C 4X 3/4 NPT
tEMPERAtuRE Passive Comb (screened): -40°C to +75°C PASSIVE SENSOR 8 lbs (3.6 kg) - 316 SS
RAnGE Passive MOS (sintered): -40°C to +70°C Note: This Bulletin contains only a general Corporate Headquarters:
Passive MOS (screened): -40°C to +75°C description of the products shown. While uses MSA – the Safety Company
IR400 (CSA): -40°C to +75°C and performance capabilities are described, 1000 Cranberry Woods Drive
under no circumstances shall the products be Cranberry Township, PA 16066
IR400 (ATEX/IECEx): -60°C to +75°C used by untrained or unqualified individuals United States
XCell Comb: -55°C to +60°C and not until the product instructions +1-724-776-8600
XCell Toxic & O2: -40°C to +60°C including any warnings or cautions provided [email protected]
have been thoroughly read and understood.
StORAGE S5000: -45°C to +85°C Only they contain the complete and detailed Design Center:
tEMPERAtuRE RAnGE (includes housing and all sensors) information concerning proper General Monitors
use and care of these products. 26776 Simpatica Circle
OPERAtInG HuMIDIty 10-95% (XCell Toxics & O2) Specifications subject to change Lake Forest, CA 92630
RAnGE 0-95% (Passive & XCell Comb, IR400, Passive MOS) without notice. United States
+1-949-581-4464
[email protected]
*At ambient conditions ID 1465-021-MC / Apr 2017