Architecture Design - Vi: School of Planning & Architecture Hyderabad
Architecture Design - Vi: School of Planning & Architecture Hyderabad
Architecture Design - Vi: School of Planning & Architecture Hyderabad
HYDERABAD.
ARCHITECTURE DESIGN – VI
CASE STUDY OF MLR CONVENTION CENTER, BANGLORE
BY : SRINIVAS : 1003019
MLR CONVENTION CENTRE, BANGALORE
Brigade Group was established in 1986
with property development as its main
focus. Today, Brigade is one of India's
leading property developers.
MERITS: DE-MERITS:
1.Providing water-body in front of the building people 1.Car has to take two circular drives to get into cellar.
will get fresh atmosphere.
2. Same entry for visitors and services.
2.Having indoor and outdoor party areas to have events as
per timing. 3. All round drive way is not provided.
SITE AREA PIE CHART :
SITE AREA PIE CHART :
% of area
Built up area
41%
Parking Area
59%
N
KITCHEN , TOILETS & STORE ROOMS
GROUND FLOOR PLAN:
COMMENTS:
1.Administration department has been utilized privacy
2.Visitors will not get idea of space of administration.
3.Management will observe the pre-function area
4.There is no disturbance of function of administration and private peopl
FIRST FLOOR PLAN:
SEATING
BOX OFFICE
COMMENTS:
1.Arrangement of cafeteria and auditorium will act common activity
2.Staircase activity gives the access to balcony
3.Designing of fire escape staircase has been well designed
FIRST FLOOR PLAN:
TOILETS & PAMTRY
FIRST FLOOR PLAN:
VIEW-3 LIFT
VIEW-4 STAIR
COMMENTS:
1.Corridor space is ventilated to open to sky.
2.Space in rooms has been utilized in minimum dimensions
3.Access of fire stair is provided to end of the corridor
SECOND FLOOR PLAN:
PARKING PLAN:
ENTRY
EXIT
Parking floor
Pie chart:
SECTION 01:
COMMENTS:
1.Structural system has been taken on function of activity.
2.Levels arrangement has been taken different types of activity
3.Common columns connectivity to all the structures but different arrangement
SECTION 2 :
COMMENTS:
1.Cellar utilized for covered parking
2.Kitchen and other services has been taken care for the service system to easy maintained
3.Over head tank and other services provided at roof level to do not exposed to people
4.People can view the elevation at large space opening entering into convention centre
5.Utilizing the set back with landscaping
SERVICES:
FIRE BOX FIRE ESCAPE STAIR A/C DUCTING FIRE BOX DUCT
LIGHTING GARBAGE
COMMENTS:
-Utilizing the space between the columns.
-Creating false ceiling with duct expose
-Hiding lighting positions at auditorium is no objecting to the viewers
ANY ARCHITECTURAL FORM OR INNOVATIVE DESIGN:
Idea of pavilion complementing the nature of the program /temporal
Two major components, the Banquet hall and the Auditorium blocked.
Need for identity for each of these spaces encourages us to move the
Auditorium to the higher level, the ground is now occupied by the
multifunctional space allowing it to expand in either directions. The
same holds good for the auditorium at upper level.
Guest rooms facility is taken to the upper most level, which acts as a
cover over the lounge/ multifunctional space complementing the
auditorium.
The skin defines spaces for services, lounges etc and also becomes an
integral part of the proceedings. The skin and structures accommodate
lighting, symbolic of congregational activities and celebrations.
Fire fighting arrangements
Existing structures
MERITS:
1.Overall the arrangement of spaces has been designed in different levels
2.Services has been arranged privacy to the public
3.For space utilizing chiller and other services provided on roof
DE-MERITS:
1.Parking space is sufficient but arrange ment of cars not well.
2.Only one fire fighting stair case provided .
3.Only one Internal stair case provided width is 1.0 m only.
4.Provided two 8 passenger lifts only.
5.Cafeteria is open. No protection with rain, wind and sun.
6.Kitchen is to small.
7.Entry exit of cellar floor of car parking is very narrow 3 mts only.
8.Lobby or entry foyer is no protection of rain.