Steel Connection Design
Steel Connection Design
Fall 2020
Term Project
Design simple, moment, and column base connections for the specified members and loads using
LRFD. A992 steel for column and beam; A36 steel for plates except for the end-plate of the extended
end-plate connection which is A572 Gr. 50. Each student is assigned two moment connections, two
simple connections, and one column base connection.
Table 1
FR Moment Connection Type
1 Directly-welded flange connection
2 Flanged-plated (welded) connection
3 Flanged-plated (bolted) connection
4 Flange Tee-stub (bolted) connection
5 Extended end-plate connection
2. Design simple connections for the simply supported W24´ 55 beam shown in Figure 1. The left
end of the beam is connected to the web of a W12´ 96 column through an extended single-plate
connection. The right end of the beam is connected to the flange of a W12´ 96 column through a
double-angle connection (welded or bolted). Beam span is 30 ft. Assume that a uniformly
distributed factored gravity load (self-weight + dead + live) of wu kips/ft and a factored
concentrated load Pu 5-ft from the beam end are applied on the beam.
Figure 1
3. Design a column base connection for the specified column and loads. Bending is about the strong
axis of the wide-flange column. Conservatively consider the ratio of the concrete to base plate area
is unity. Fy of the base plate is 36 ksi and f c of concrete is 4 ksi. Determine the dimension of the
base plate, anchor rod size, and shear transfer strength (bearing or shear lug).
1
Assignment:
Annamredd
450, 70
y,Venkata 1&2, W24´ 55 W14´ 53 3.0, 20 W14´ 53 4,000, 300, 75
Niranjan
Baral,Anil 1&3, W21´ 55 W14´ 61 400, 65 2.0, 30 W14´ 61 4,500, 350, 85
Chauhan,H
arjasdeep 1&5, W24´ 76 W14´ 74 550, 90 2.5, 25 W14´ 74 5,000, 400, 90
Singh
Ebrahimi,
1&4, W18´ 106 W14´ 90 600, 80 2.0, 30 W12´ 79 4,000, 300, 80
Moein
King,Mike 1&2, W21´ 93 W14´ 48 650, 75 1.5, 25 W14´ 48 4,500, 380, 95
Naqvi,Sha
1&3, W27´ 84 W14´ 109 680, 90 3.0, 20 W12´ 87 5,000, 375, 85
ms Abbas
Phairatchav
1&4, W24´ 94 W14´ 53 400, 85 2.0, 30 W14´ 53 4,500, 200, 75
es,Npon
Ranjit,Ana
1&5, W18´ 119 W14´ 68 600, 90 2.5, 25 W14´ 68 4,000, 300, 75
nta
Shah,Mites
1&2, W30´ 99 W14´ 74 700, 100 2.0, 30 W14´ 74 4,500, 350, 85
h Suhas
Shah,Mohit
1&3, W21´ 101 W14´ 109 500, 70 1.5, 25 W12´ 87 5,000, 400, 90
Hitendra
Sheen,Yon
1&4, W24´ 84 W14´ 53 500, 80 2.8, 22 W14´ 53 4,000, 300, 80
ghoon
Soares
Santos,Mur 1&5, W27´ 94 W14´ 82 700, 95 3.2, 25 W14´ 82 4,500, 380, 95
ilo
Yadav,Sach
1&2, W18´ 71 W14´ 48 450, 55 1.8, 27 W14´ 48 5,000, 375, 85
in
Danielson,
1&3, W24´ 62 W14´ 74 400, 85 2.5, 15 W14´ 74 4,500, 200, 75
Olen
Rhodes,Ro
1&4, W21´ 68 W14´ 82 420, 70 2.7, 28 W14´ 82 4,000, 250, 80
wdee
Stephens,Ju
1&5, W24´ 103 W14´ 109 700, 80 2.5, 30 W12´ 72 4,500, 300, 95
stin
Woolard,W
1&2, W18´ 60 W14´ 74 400, 65 2.0, 20 W12´ 50 4,600, 250, 90
illiam
†Column section can be changed. Assume column is an exterior column with beam framing into
the joint from one side. Axial load in the column is 400 kips. Neglect the effect of story shear for
calculation purposes.
2
Notes:
Make reasonable assumptions for any information you consider needed but not provided.
In the final report please show the details of each design and shop drawings (AutoCAD or
MicroStation drawings) with appropriate welding symbols, as well as Sketchup drawings of all
your assigned connections.
The final report (electronic copy) for the term project is due on Tuesday December 8. Please
submit the report and the Sketchup drawings to me electronically.
3
Directly-welded
flange connection
Project: CE5314 Advanced Steel Design II 12/15/2020
Client: Shih-Ho Chao
Engineer:
Remarks: Project 1.2
R n 6.25(t f ) 2 Fy C t See Eq. 3.20 of Design Guide #4, 2nd Edition for Extended End Plates
C) Web Local Yielding: Tensile and Compressive Forces (2005 Specification Section J10.2)
f= 1.00 (LRFD) W= 1.50 (ASD)
Reinforcing
w= 0.64 in
Fillet Weld
N= 1.92 in Length of Bearing
tw = 0.53 in Column Web Thickness N W
dc = 14.30 in Column Depth
Ct = 1.0 = 0.5 if the distance from the end of the column to the closer face
of the beam tension flange is less than dc
= 1.0 otherwise
k= 1.46 in Distance from the outside face of column flange to the
web toe of the flange-to-web fillet
f Rn = 242 kips Local Web Yielding Nominal Strength
Rav = 242 kips Available Strength, fRn (LRFD), Rn/W (ASD)
See Eq. 3.24 of Design Guide #4, 2nd Edition for Extended End Plates
E) Web Compression Buckling: Compressive Force on Both Sides of the Column (2005 Specification Section J10.5)
f= 0.90 (LRFD) W= 1.67 (ASD)
tw = 0.525 in Column Web Thickness
dc = 14.30 in Column Depth
k= 1.46 in Distance from the outside face of column flange to the
web toe of the flange-to-web fillet
Ct = 1.0 = 0.5 if the distance from the end of the column to the closer face
of the beam tension flange is less than dc/2
= 1.0 otherwise
h= 11.38 in Zone of column web subject to compression buckling (out-of-plane) h=dc-2k
Rn = 367 kips Compression Buckling Design Strength
Rav = 331 kips Available Strength, fRn (LRFD), Rn/W (ASD)
III) Column Design Summary: W14X109
A) Doubler Plates Required if Vp > Rav for Panel Zone Shear
Total Panel Zone Shear Panel-Zone Available
Force, Vp = 313 kips Shear Strength = 203 kips
Doubler Plates are Required! 154% of Column Capacity
B) Stiffener Plates are Required if Pf > Rav for Compression
Local Web Yielding
Available Strength = 242 kips
Web Crippling Available
Strength = 304 kips
Compression Buckling
Concentrated Compression Available Strength = DNA kips
Force, Pf = 313 kips Rav = 242 kips
Stiffener Plates are Required! 129% of Column Capacity
W27X84 BEAM
1'-0.6"
3/16
3/16
W14X109 1.8"
COLUMN 1.5"
1'-0.6"
1' 2'-7.0"
3.0" 6.0"
9.6"
3.6"
3/16
1/2(3/8)
45
R n 6.25(t f ) 2 Fy C t See Eq. 3.20 of Design Guide #4, 2nd Edition for Extended End Plates
C) Web Local Yielding: Tensile and Compressive Forces (2005 Specification Section J10.2)
f= 1.00 (LRFD) W= 1.50 (ASD)
Reinforcing
w= 0.64 in
Fillet Weld
N= 2.28 in Length of Bearing
tw = 0.53 in Column Web Thickness N W
dc = 14.30 in Column Depth
Ct = 1.0 = 0.5 if the distance from the end of the column to the closer face
of the beam tension flange is less than dc
= 1.0 otherwise
k= 1.46 in Distance from the outside face of column flange to the
web toe of the flange-to-web fillet
f Rn = 251 kips Local Web Yielding Nominal Strength
Rav = 251 kips Available Strength, fRn (LRFD), Rn/W (ASD)
See Eq. 3.24 of Design Guide #4, 2nd Edition for Extended End Plates
E) Web Compression Buckling: Compressive Force on Both Sides of the Column (2005 Specification Section J10.5)
f= 0.90 (LRFD) W= 1.67 (ASD)
tw = 0.525 in Column Web Thickness
dc = 14.30 in Column Depth
k= 1.46 in Distance from the outside face of column flange to the
web toe of the flange-to-web fillet
Ct = 1.0 = 0.5 if the distance from the end of the column to the closer face
of the beam tension flange is less than dc/2
= 1.0 otherwise
h= 11.38 in Zone of column web subject to compression buckling (out-of-plane) h=dc-2k
Rn = 367 kips Compression Buckling Design Strength
Rav = 331 kips Available Strength, fRn (LRFD), Rn/W (ASD)
III) Column Design Summary: W14X109
A) Doubler Plates Required if Vp > Rav for Panel Zone Shear
Total Panel Zone Shear Panel-Zone Available
Force, Vp = 295 kips Shear Strength = 203 kips
Doubler Plates are Required! 145% of Column Capacity
B) Stiffener Plates are Required if Pf > Rav for Compression
Local Web Yielding
Available Strength = 251 kips
Web Crippling Available
Strength = 313 kips
Compression Buckling
Concentrated Compression Available Strength = DNA kips
Force, Pf = 295 kips Rav = 251 kips
Stiffener Plates are Required! 117% of Column Capacity
W27X84 BEAM
3/16
3/16 1'-0.6"
1' 2'-7.0"
3.0" 6.0"
9.6"
3.6"
3/16 1'-1.0"
Ø1.2"
2.3"
1" DIA. BOLT 10.0"
2.0"
3.0"
3.0"
3.0"
BOLTED-FLANGE PLATE
1/2(3/8)
45
FLANGE-PLATED(BOLTED) CONNECTION
5
16" 2L5X3 1/2X1/4
5
16"
W24X55 BEAM
1'-2.0"
2.0"
2.0" W12x96
W12x96 COLUMN
COLUMN 1'-1.0"
3.0"
3.0"
2L5X3 1/2X1/4
5 7/8" DIA. BOLT
16" 1.4"
5
16"
1.3"
3.0"
11.5"
3.4"
2.3"
2.3"
2'-1.0"
Ø2.5"
1'-0.6"
3/16
3/16 3/16
3/16 1'-0.6"
2'-7.0"
16"
1'
3.6"
3.0" 6.0"
SHEAR CONNECTIONS STIFFENER PLATE
9.6" 7/8" DIA. BOLT
WEB PANEL 3.6"
3/16
3/16 1'-1.0"
Ø1.2" 1'-2.0"
2.3" 2.0"
1" DIA. BOLT 10.0"
2.0" W12x96
W12x96 COLUMN
2.0"
COLUMN 1'-1.0"
3.0" 3.0"
3.0"
3.0"
3.0"
BOLTED-FLANGE PLATE
EXTENDED SINGLE-PLATE CONNECTION &DOUBLE ANGLE CONNECTION
1/2(3/8)
45 1/2(3/8)
45
DIRECTLY WELDED FLANGE CONNECTION FLANGE-PLATED(BOLTED) CONNECTION 2L5X3 1/2X1/4
5 7/8" DIA. BOLT
16" 1.4"
5
16"
1.3"
3.0"
11.5"
3.4"
2'-1.0" 5
16"
2.3"
2.3"
2'-1.0"
Ø2.5"