Solenoid Directional Valves SDHL - Compact Execution: Direct Operated, ISO 4401 Size 06
Solenoid Directional Valves SDHL - Compact Execution: Direct Operated, ISO 4401 Size 06
Solenoid Directional Valves SDHL - Compact Execution: Direct Operated, ISO 4401 Size 06
.
Spool type, two or three position direct
operated valves size 06 in compact
execution with reduced solenoids
. . .
dimensions, ideal for applications in mini
power packs, mobile and agricultural
. .
machines.
Solenoids are made by:
• wet type screwed tube , different for
AC and DC power supply, with
integrated manual override pin
• interchangeable coils , specific for
A B AC or DC power supply, easily
SDHL-061*-AC
. .
replaceable without tools - see section
5 for available voltages
Standard coils protection IP65
. .
Wide range of interchangeable spools ,
. .. .
. .
Valve body see section 2.
Spool The valve body is 3 chamber type
made by shell-moulding casting with wide
Solenoid tube internal passages ensuring low pressure
Solenoid coil drops.
Manual override pin Mounting surface: ISO 4401 size 06
Electric connector (DIN43650) A B Max flow: 40 l/min
to be ordered separately SDHL-071*-DC Max pressure: 350 bar
1 MODEL CODE
SDHL - 0 61 1 /A - X 24 DC ** /*
Directional control valves size 06 Seals material,
compact execution see section 4:
- = NBR
Valve configuration, see section 2 PE = FKM
61 = single solenoid, center plus external position, spring centered
63 = single solenoid, 2 external positions, spring offset
71 = double solenoid, 3 positions, spring centered Series number
75 = double solenoid, 2 external positions, with detent
Voltage code, see section 5
Spool type, see section 2.
X = without connector
Options: A, WP, see section 5 See section 6 for available connectors, to be ordered separately
61 1 0 2 1 0 2 1 0 2 1 0 2 63 1 0 2
1 0 1 2
0 1 2 3 0/2
61/A 63/A
0 2 4 5 6 7 1 2 1/2
71 8 91 19 93 75
2/2
(1)
1 0 2 1 2
39 58
(1) not available for
configuration 75
SHE018
3 MAIN CHARACTERISTICS
4 SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office
NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
Seals, recommended fluid temperature
FKM seals (/PE option) = -20°C ÷ +80°C
Recommended viscosity 15÷100 mm2/s - max allowed range 2,8 ÷ 500 mm2/s
Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 mm (b10 >
_ 75 recommended)
Hydraulic fluid Suitable seals type Classification Ref. Standard
Mineral oils NBR, FKM HL, HLP, HLPD, HVLP, HVLPD DIN 51524
Flame resistant without water FKM HFDU, HFDR
ISO 12922
Flame resistant with water NBR HFC
5 OPTIONS
Options
A = Solenoid mounted at side of port B (only for single solenoid valves). In standard versions, solenoid is mounted at side of port A.
WP = prolonged manual override protected by rubber cap.
The manual override operation can be possible only if the pressure at T port is lower than 50 bar
6 ELECTRIC FEATURES
666, 667
28.5 27 1 = Positive
2 = Negative
= Coil ground
30
27
42
SUPPLY VOLTAGES
666 667
24 AC or DC
All 110 AC or DC
voltages 220 AC or DC
8 Q/DP DIAGRAMS based on mineral oil ISO VG 46 at 50°C
SDHL
Flow direction G F E
P씮A P씮B A씮T B씮T P씮T 8
Spool type
7 D
2 D D 1
2/2 F F
19, 91 E E D D 0 10 20 30 40 50
0 10 20 30 40
Flow rate [l/min]
SDHL - AC
360
Curve AC version, spool type: B A
300
E C
A 1, 1/2, 8
Inlet pressure [bar]
240
D
B 0, 0/1, 0/2, 1/1, 3
180
C 3, 3/1, 6, 7
120
D 4, 4/8, 5, 5/1, 19, 39, 58, 58/1, 91, 93
60
E 2, 2/2
0 10 20 30 40
Flow rate [l/min]
SDHL 10 - 25 20 - 40 30 - 50 15 - 25
11 SWITCHING FREQUENCY
Valve AC DC
(cycles/h) (cycles/h)
SDHL + 666 / 667 7200 15000
SHE018
12 DIMENSIONS [mm]
0.75 31.75
25.9
31
M5x30 class 12.9 A, B = USE PORT
Tightening torque = 8 Nm T = TANK PORT
15.5
5.1
Seals: 4 OR 108 12.7
Ports P,A,B,T: Ø = 7.5 mm (max) 21.5
30.2
40.5
SDHL-06(DC) SDHL-07(DC)
4 Nm
82
47
22
21.5 = = 55 69 55
55 69 7.7 45 179
131.7
Mass: 1,3 kg Mass: 1,6 kg
SDHL-06(AC) SDHL-07(AC)
4 Nm
79
47
22
21.5 = = 65 69 65
65 69 7.7 45 199
141,7
Mass: 1,2 kg Mass: 1,4 kg
75 83,5
The manual override operation can be possible only if the pressure at T ports is lower than 50 bar
The use of plug-in restrictors in valve’s ports P or A or B may be necessary is case of particular conditions ø **
as long flexible hoses or the presence of accumulators which could cause at the valve switching instanta-
neous high flow peaks over the max valve’s operating limits.
09/16