Solenoid Directional Valves SDHL - Compact Execution: Direct Operated, ISO 4401 Size 06

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

www.atos.

com Table SHE018-1/E

Solenoid directional valves type SDHL - compact execution


direct operated, ISO 4401 size 06

.
Spool type, two or three position direct
operated valves size 06 in compact
     execution with reduced solenoids

. . .
dimensions, ideal for applications in mini
power packs, mobile and agricultural

. .
machines.
Solenoids are made by:
• wet type screwed tube , different for
 AC and DC power supply, with
integrated manual override pin 
• interchangeable coils , specific for
A B AC or DC power supply, easily
SDHL-061*-AC

. .
replaceable without tools - see section
5 for available voltages
      Standard coils protection IP65

. .
Wide range of interchangeable spools ,

. .. .


. .
Valve body see section 2.
 Spool The valve body  is 3 chamber type
made by shell-moulding casting with wide
 Solenoid tube internal passages ensuring low pressure
 Solenoid coil   drops.
 Manual override pin Mounting surface: ISO 4401 size 06
 Electric connector (DIN43650) A B Max flow: 40 l/min
to be ordered separately SDHL-071*-DC Max pressure: 350 bar

1 MODEL CODE

SDHL - 0 61 1 /A - X 24 DC ** /*
Directional control valves size 06 Seals material,
compact execution see section 4:
- = NBR
Valve configuration, see section 2 PE = FKM
61 = single solenoid, center plus external position, spring centered
63 = single solenoid, 2 external positions, spring offset
71 = double solenoid, 3 positions, spring centered Series number
75 = double solenoid, 2 external positions, with detent
Voltage code, see section 5
Spool type, see section 2.

X = without connector
Options: A, WP, see section 5 See section 6 for available connectors, to be ordered separately

2 CONFIGURATIONS and SPOOLS (representation according to ISO 1219-1)

Configurations Spools Configurations Spools

61 1 0 2 1 0 2 1 0 2 1 0 2 63 1 0 2
1 0 1 2
0 1 2 3 0/2

61/A 63/A

0 2 4 5 6 7 1 2 1/2

71 8 91 19 93 75
2/2
(1)
1 0 2 1 2
39 58
(1) not available for
configuration 75

2.1 Special spools


- spools type 0 and 3 are also available as 0/1 and 3/1 with restricted oil passages in central position, from user ports to tank.
- spools type 1, 4, 5 and 58 are also available as 1/1, 4/8, 5/1 and 58/1. They are properly shaped to reduce water-hammer shocks during the swiching.
- spools type 1, 1/2, 3, 8 are available as 1P, 1/2P, 3P, 8P to limit valve internal leakages.
- Other types of spools can be supplied on request.

SHE018
3 MAIN CHARACTERISTICS

Assembly position / location Any position


Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
Standard execution = -30°C ÷ +70°C
Ambient temperature
/PE option = -20°C ÷ +70°C
Flow direction As shown in the symbols of table 2
Ports P,A,B: 350 bar;
Operating pressure
Port T 210 bar for DC version; 160 bar for AC version
Maximum flow 40 l/min, see Q/Dp diagram at section 8 and operating limits at section 9

3.1 Coils characteristics


H (180°C) for DC coils F (155°C) for AC coils
Insulation class Due to the occuring surface temperatures of the solenoid coils, the European standards EN ISO
13732-1 and EN ISO 4413 must be taken into account
Protection degree to DIN EN 60529 IP 65 (with connectors 666, 667 correctly assembled)
Relative duty factor 100%
Supply voltage and frequency See electric feature 6
Supply voltage tolerance ± 10%

4 SEALS AND HYDRAULIC FLUID - for other fluids not included in below table, consult our technical office

NBR seals (standard) = -20°C ÷ +60°C, with HFC hydraulic fluids = -20°C ÷ +50°C
Seals, recommended fluid temperature
FKM seals (/PE option) = -20°C ÷ +80°C
Recommended viscosity 15÷100 mm2/s - max allowed range 2,8 ÷ 500 mm2/s
Fluid contamination class ISO 4406 class 21/19/16 NAS 1638 class 10, in line filters of 25 mm (b10 >
_ 75 recommended)
Hydraulic fluid Suitable seals type Classification Ref. Standard
Mineral oils NBR, FKM HL, HLP, HLPD, HVLP, HVLPD DIN 51524
Flame resistant without water FKM HFDU, HFDR
ISO 12922
Flame resistant with water NBR HFC

5 OPTIONS
Options
A = Solenoid mounted at side of port B (only for single solenoid valves). In standard versions, solenoid is mounted at side of port A.
WP = prolonged manual override protected by rubber cap.

The manual override operation can be possible only if the pressure at T port is lower than 50 bar

6 ELECTRIC FEATURES

External supply Power


Voltage Type Code of spare coil
nominal voltage consumption
code of connector SDHL
± 10% (2)
12 DC 12 DC COL-12DC
14 DC 14 DC COL-14DC
666 22 W
24 DC 24 DC COL-24DC
or
28 DC 28 DC COL-28DC
667
110/50 AC (1) 110/50/60 AC 58 VA COL-110/50/60AC
230/50 AC (1) 230/50/60 AC (3) COL-230/50/60AC
(1) Coil can be supplied also with 60 Hz of voltage frequency: in this case the performances are reduced by 10 ÷15% and the power
consumption is 52 VA.
(2) Average values based on tests preformed at nominal hydraulic condition and ambient/coil temperature of 20°C.
(3) When solenoid is energized, the inrush current is approx 3 times the holding current.

7 ELECTRIC CONNECTORS ACCORDING TO DIN 43650 (to be ordered separately)


666 = standard connector IP-65, suitable for direct connection to electric supply source.
667 = as 666, but with built-in signal led.
666, 667 (for AC or DC supply) CONNECTOR WIRING

666, 667
28.5 27 1 = Positive
2 = Negative
= Coil ground
30

27
42

SUPPLY VOLTAGES

666 667
24 AC or DC
All 110 AC or DC
voltages 220 AC or DC
8 Q/DP DIAGRAMS based on mineral oil ISO VG 46 at 50°C
SDHL
Flow direction G F E
P씮A P씮B A씮T B씮T P씮T 8
Spool type
7 D

Valve pressure drop Dp [bar]


0, 0/1 A A C C D
1, 1/1 D C C C 6 C
3, 3/1 D D A A 5 B
4, 4/8, 5, 5/1, 58, 58/1 F F G C E 4 A
1/2, 0/2 D D D D
3
6, 7 D D D D
8 A A E E 2

2 D D 1
2/2 F F
19, 91 E E D D 0 10 20 30 40 50

39, 93 F F G G Flow rate [l/min]

9 OPERATING LIMITS based on mineral oil ISO VG 46 at 50°C


The diagrams have been obtained with warm solenoids and power supply at lowest value (Vnom - 10%). The curves refer to application with symmetrical
flow through the valve (i.e. P씮A and B씮T). In case of asymmetric flow and if the valves have the devices for controlling the switching times the operating
limits must be reduced.
SDHL - DC
360
Curve DC version, spool type: A
300
B

Inlet pressure [bar]


A 1, 1/2, 8 C
240
D
B 0, 0/1, 0/2, 1/1, 3, 6, 7, 19
180
C 4, 4/8, 5, 5/1, 19, 39, 58, 58/1, 91, 93
120
D 2, 2/2
60

0 10 20 30 40
Flow rate [l/min]

SDHL - AC
360
Curve AC version, spool type: B A
300
E C
A 1, 1/2, 8
Inlet pressure [bar]

240
D
B 0, 0/1, 0/2, 1/1, 3
180
C 3, 3/1, 6, 7
120
D 4, 4/8, 5, 5/1, 19, 39, 58, 58/1, 91, 93
60
E 2, 2/2
0 10 20 30 40
Flow rate [l/min]

10 SWITCHING TIMES (average values in msec)


Test conditions: - 20 l/min; 150 bar
- nominal voltage
- 2 bar of counter pressure on port T
- mineral oil: ISO VG 46 at 50°C
The elasticity of the hydraulic circuit and the variations of the hydraulic characteristics and temperature affect the response time.

Valve Switch-on Switch-off Switch-on Switch-off


AC AC DC DC

SDHL 10 - 25 20 - 40 30 - 50 15 - 25

11 SWITCHING FREQUENCY

Valve AC DC
(cycles/h) (cycles/h)
SDHL + 666 / 667 7200 15000

SHE018
12 DIMENSIONS [mm]

ISO 4401: 2005 ø5.5


Mounting surface: 4401-03-02-0-05
Fastening bolts: 4 socket head screws: P = PRESSURE PORT

0.75 31.75
25.9
31
M5x30 class 12.9 A, B = USE PORT
Tightening torque = 8 Nm T = TANK PORT

15.5
5.1
Seals: 4 OR 108 12.7
Ports P,A,B,T: Ø = 7.5 mm (max) 21.5
30.2
40.5

SDHL-06(DC) SDHL-07(DC)

4 Nm

82
  

47
22

21.5 = = 55 69 55
55 69 7.7 45 179
131.7
Mass: 1,3 kg Mass: 1,6 kg

SDHL-06(AC) SDHL-07(AC)

4 Nm
79

  
47
22

21.5 = = 65 69 65
65 69 7.7 45 199
141,7
Mass: 1,2 kg Mass: 1,4 kg

Option /WP Option /WP


(DC version) (AC version)

75 83,5

 Standard manual override PIN

The manual override operation can be possible only if the pressure at T ports is lower than 50 bar

Overall dimensions refer to valves with connector 666

13 PLUG-IN RESTRICTOR (to be ordered separately)

The use of plug-in restrictors in valve’s ports P or A or B may be necessary is case of particular conditions ø **
as long flexible hoses or the presence of accumulators which could cause at the valve switching instanta-
neous high flow peaks over the max valve’s operating limits.

Ordering code: PLUG H - **

08, 10, 12, 15 calibrated orifice diameter in tenths of mm


Example PLUG-H-12 = orifice diameter 1,2 mm PLUG H-**
Other orifice dimensions are available on request

09/16