ISIO 

200
Binary Input/Output (I/O) terminal
with IEC 61850 interface
Compact and easy – ISIO 200

Put your Binary I/Os where you need them


ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850 interface. For
communicating with CMC test sets and real-time message exchange with peer
devices, the fast GOOSE messaging is used. By using Client/Server communica-
tion, ISIO 200 can be integrated into Substation Automation Systems (SAS) and
communicate to a station controller.
In combination with a CMC test set, ISIO 200 extends the binary I/O capability of
the test system. As a component of an SAS, it handles additional binary signals.
Due to its compact design, binary I/O terminals can be put wherever necessary.
ISIO 200 is configured via a built-in web interface and needs no special configura-
tion software to be installed on your computer. Configuration files can be
exported from the device in the standardized SCL format.
To simplify handling and minimize wiring efforts, ISIO 200 is supplied with Power
over Ethernet (PoE). No dedicated power supply is required.

Binary I/O status LEDs

8 binary inputs

2
Fields of application
The ISIO 200 serves multiple applications in substation automation systems.
Depending on whether the device is used for testing purposes (often together with a CMC test set) or in regular SAS opera-
tion, they are divided in two categories:

Testing in Substation Automation Systems with CMC Operating ISIO 200 in Substation Automation Systems
test sets >> Interface for conventional equipment to IEC 61850
>> Testing sophisticated protection schemes >> I/O terminal for SAS utilizing GOOSE
>> Access to remote binary I/O terminals >> Back-to-back binary I/O forwarding via Ethernet
>> Permanently installed terminal for testing

Ethernet port

DC power supply

Your benefits
>> Testing of complex protection schemes
with CMC test sets
>> Remote control of binary outputs
>> Indication of GOOSE timeouts and
malfunctions using alarm output contact
>> Integration of conventional devices into
IEC 61850 systems
8 binary outputs
>> Status interface with data models for
overcurrent relays, switchgear, and
teleprotection

www.omicronenergy.com/ISIO200
3
Fields of application

Testing in Substation Automation Systems with CMC test sets


Test setups in SAS often require bridging of long distances or an extension of the CMC’s
binary I/O capabilities.
The ISIO 200 can be used as accessory for the CMC to increase the number of binary I/Os
of the test system. The accessory can be configured easily using the Test Universe ISIO
Connect module.1 The CMC and ISIO 200 communicate via GOOSE messages. This allows
distances to be bridged up to dozens of meters with an Ethernet cable.

1 Testing sophisticated protection schemes Ethernet

When testing protection schemes with main and backup - +

protection and telecommunication, the setup can easily get GOOSE


E TH POWER
BIN A RY IN 1– 4 BIN A RY IN 5 – 8 BIN A RY OUT 1– 4 BIN A RY OUT 5 – 8

so complex that more than 10 binary inputs and 4 binary CMC 1


outputs are required. In such cases, the ISIO 200 is the ideal Voltages
Currents
extension of the CMC’s binary I/O capabilities.

Trip Trip

IED 1 IED 2

2 Access to remote binary I/O terminals


Connecting to binary I/Os that are more than just a few
meters away from the test set is often cumbersome.
The ISIO 200 can be conveniently placed close to remote
access points to keep the conventional wiring as short as
possible. The longer distance to the test set is simply bridged
with an Ethernet cable.

3 Permanently installed test terminal


The binary I/Os of a protection relay are permanently wired
to an ISIO 200. For testing, the binary wiring of the test set
is reduced to connecting the Ethernet cable. The ISIO 200
becomes powered as soon as it is connected to the CMC.

For Test Universe versions prior to 3.10 the GOOSE Configuration


1

module is required

4
Operating ISIO 200 in Substation Automation Systems
Use the device to simply add binary I/Os in your SAS or for forwarding binary I/Os over
Ethernet by connecting two ISIO 200 units back-to-back.
ISIO 200 communicates via the fast and robust IEC 61850 GOOSE protocol and, therefore,
interoperates with a wide range of substation automation devices.

Substation Network
1 Interface for conventional equipment to IEC 61850
Often binary I/O status information of conventional equip-
ment needs to be communicated to a station controller or
SCADA system. IEC 61850
For this application the ISIO 200 provides different data Binary
I/Os
models for integrating conventional equipment, such as - +

overcurrent relays, circuit breakers or disconnector switches


E TH POWER
BINARY IN 1– 4 BINARY IN 5 – 8 BINARY OUT 1– 4 BINARY OUT 5 – 8

into IEC 61850 automation systems.

Substation Network
2 I/O extension for SAS using GOOSE
The frequent need for a few additional binary I/Os in a
substation automation system is easily and efficiently
facilitated with the ISIO 200.
If the I/O capabilities of an IED are exhausted but more - +

binary I/Os are still needed, an ISIO 200 “connected” via GOOSE BINA RY IN 1– 4 BINA RY IN 5 – 8
E TH
BINA RY OUT 1– 4
POWER
BINA RY OUT 5 – 8

GOOSE delivers this.

Binary I/Os

Substation Network
3 Back-to-back binary I/O forwarding via ethernet
By using two ISIO 200 “back-to-back”, binary status informa-
tion is tunneled over the substation network.
If ordered in matched pairs, the two ISIO 200s are pre­
configured to subscribe to each other. This configuration
- + - +

GOOSE
E TH POWER E TH POWER
BINA RY IN 1– 4 BINA RY IN 5 – 8 BINA RY OUT 1– 4 BINA RY OUT 5 – 8 BINA RY IN 1– 4 BINA RY IN 5 – 8 BINA RY OUT 1– 4 BINA RY OUT 5 – 8

works out of the box.


A configurable alarm output contact indicates GOOSE
timeouts and malfunctions. Binary I/Os Binary I/Os

5
ISIO 200

Configuration Mounting options

Configuration via web interface Tabletop use


The ISIO 200 is configured via a web interface. No special Rubber sealing around the housing guarantees a soft and
configuration software needs to be installed on a computer. secure stand when using the ISIO 200 as a tabletop device.
The web interface supports mobile devices with small
screens and provides diagnostic information to help find DIN rail mounting
errors in the configuration.
For permanent installation in substations, the device can be
mounted on a DIN rail. The mounting clip at the back makes
Usage as accessory for CMC test sets it easy to fit the ISIO 200 into a variety of cabinet designs
To set up a CMC test set to interface with an ISIO 200, the (mounting set included in the delivery).
ISIO Connect module included in Test Universe version 3.10
and later can be used.
ISIO 200 also allows to directly download settings that can
be imported into the Test Universe GOOSE configuration
module.

Custom GOOSE configuration


Sophisticated GOOSE configurations are set up with the
Test Universe GOOSE Configuration module, which is
normally used for CMC test sets. Such custom configurations ISIO 200 mounted on DIN rail
can easily be loaded into the ISIO 200.
Flat surface mounting
Export Substation Configuration Language (SCL) Mounting brackets allow the ISIO 200 to be permanently
For use in the IEC 61850 engineering process, the descrip- attached to any flat surface (mounting brackets are included
tion of the ISIO 200 can be downloaded from the device in in the delivery).
SCL Edition 1 and Edition 2 format.

Easy configuration via web interface

6
Technical specifications Ordering information

Binary Inputs: BINARY IN 1-4 / BINARY IN 5-8 Description Order no.


Binary inputs 8 (2 potential groups) ISIO 200 (single unit) VESC1600

Max. input voltage CAT II / 250 V (rms) (IEC 61010-2-030) ISIO 200 matched pair (2 preconfigured devices) VESC1601

Threshold voltage 18 V default; configurable via web interface


Timing Binary input activation → published GOOSE:
850 µs (typical)

Binary outputs: BINARY OUT 1-4 / BINARY OUT 5-8


Binary outputs 8 (2 potential groups)
Voltage 250 V
Max. current 8 A (max. 2000 VA or 50 W)
Timing Received GOOSE → binary output contact closing:
5.5 ms (typical)

Power supply: ETH (PoE) or POWER


Power over ethernet (PoE): ETH
PoE class Class 2 powered device (IEEE 802.3af)
External DC power input: POWER
Input voltage 18 V ... 57 V
Power consumption <5W

Environmental conditions
Ambient temperature -20 °C ... +55 °C (+70 °C for 96 h)
-4 °F ... +131 °F (+158 °F for 96 h)
Humidity 5 % ... 95 % rel. humidity; non-condensing

Insulation coordination
Protection class Class II (double insulated)
Overvoltage category II according to IEC 61010-1
III according to IEC 60255-27
Pollution degree 2

Mechanics
Weight 800 g (1.8 lbs)
Dimensions (W x H  x D) 170 mm x 50 mm x 125 mm
6.7 in x 2.0 in x 4.9 in
IP rating IP40 (IEC 60529)

Safety
Standard IEC 61010-1; IEC 60255-27;
IEC 60950-1 (Insulation of ETH and SELV)

7
OMICRON is an international company serving the electrical power industry with
innovative testing and diagnostic solutions. The application of OMICRON products
allows users to assess the condition of the primary and secondary equipment on
their systems with complete confidence. Services offered in the area of consulting,
commissioning, testing, diagnosis and training make the product range complete.

Customers in more than 160 countries rely on the company’s ability to supply leading-
edge technology of excellent quality. Service centers on all continents provide a broad
base of knowledge and extraordinary customer support. All of this together with our
strong network of sales partners is what has made our company a market leader in the
electrical power industry.

For more information, additional literature, and detailed contact


information of our worldwide offices please visit our website.

© OMICRON L2540, February 2020


www.omicronenergy.com Subject to change without notice.