Data Sheet
S1210 EMI Pre-compliance Software
DSA Series Spectrum Analyzer
EMC Laboratory
Antenna
LISN
You can perform conduction and radiation tests using S1210 EMI Pre-compliance Software and RIGOL DSA series spectrum
analyzer. You can measure the interference voltage on the power cable using the linear impedance stability network (LISN) and
perform amplitude correction on the results by loading the correction factor (preamplifier, attenuator, antenna, cable, or correction
array) automatically in the radiation test.
This software also provides various functions to facilitate your measurements. You can set various parameters (such as the frequency
range, resolution bandwidth, and scan time) via the scan table. After performing a scan, the results can be displayed in log or linear
format. You can search for signal peak value and view the results displayed in the peak table. Besides, you can mark and delete the
undesired signal, as well as easily recognize signals that do not pass the standard limit line. The software also supports the marker
table. In the marker table, you can double click the table to add a marker to mark any frequency point that interests you.
Product Features
● Introduce the workspace concept; manage multiple measurements
● Support the demo mode for you to enjoy a great user experience with the software, without connecting the instrument or
obtaining a license
● Provide data manager function for you to edit required files for the software
● Provide amplitude correction function for you to preview the correction setting and get the calibration results in a timely manner
● Provide pre san and final scan, support three trace display modes: "Clear/Write", "Repeat Clear/Write", and "Repeat Max Hold"
● Provide the limit line for you to quickly judge the measurement results
● Support segment scanning and editing for the table to accelerate the measurement speed
● Frequency axis supports the scale display in linear or log format
● Amplitude axis supports multiple amplitude units
● Provide comprehensive peak search settings for you to search for the desired peaks that meet with your search conditions
● Support importing and exporting the peak table
● Support editing the marker table, marking any frequency point that interest you
● Support the reference trace, easy for you to compare the measurement results
● Support easy operation on the spectrum graph, convenient for you to analyze the results
● Provide report generation function
Product Functions
To quickly perform the EMI test with the software, we recommend you to follow the measurement procedures as shown
in the figure below.
Peak Table
(*.pkl)
Correction Config
Load and select the correction file; compensate the gain or loss of the external devices (such as the antenna and cable). You can view the
correction data in the Correction Preview.
Scan Config
Load and select the limit line file, set the limit lines, configure parameters for pre scan and final scan.
Segment Config
Set the parameters for the segment scan separately, and view the segment scan data sheet in the segment table. Besides, you can export the
segment scan table currently edited, or import the edited segment scan table.
Graph Config
Set the graph axis and the graph title.
Pre Scan
Perform segment pre scan based on the segment scan setting to improve the measurement speed of the software. After the scan is completed,
you can preview the measurement results in the spectrum graph, and compare the results with the set limit line value.
Peak Search
Perform the peak search operation. The software filters and marks the peak table according to the user-defined conditions. You can edit the
peak table; add or delete frequency points; export/import the peak table.
Final Scan
The final scan provides a more accurate scan on the critical interference signals to ensure the measurement accuracy of the software.
Report
Fill in the actual parameter values based on the current measurement environment, and add remarks if necessary. You can also print the
activated measurement report for further progressing of the measurement values.
Specifications