Samsung Ar09 12hssfawkneu Hasznalati

Download as pdf or txt
Download as pdf or txt
You are on page 1of 114

Basic model: AR12HSSDBWKNEU AR12HSSDBWKXEU

Model: AR09HSSFAWK AR09HSSFAWK


AR12HSSFAWK AR12HSSFAWK
AR09HSSFBWK AR09HSSFBWK
AR12HSSFBWK AR12HSSFBWK
AR12HSSFMWK AR12HSSFMWK
AR09HSSFAWKNEU AR09HSSFAWKXEU
AR12HSSFAWKNEU AR12HSSFAWKXEU
AR09HSSFBWKNEU AR09HSSFBWKXEU
AR12HSSFBWKNEU AR12HSSFBWKXEU
AR12HSSFMWKNAX AR12HSSFMWKXAX

AR09HSSFAWKNEU
AR12HSSFAWKNEU
AR09HSSFBWKNEU
AR12HSSFBWKNEU
AR12HSSFMWKNAX

AR09HSSFAWKXEU
AR12HSSFAWKXEU
AR09HSSFBWKXEU
AR12HSSFBWKXEU
AR12HSSFMWKXAX
Contents
1. Precautions ············································································································· 1-1
1-1 Installing the air conditioner ·························································································································· 1-1
1-2 Power supply and circuit breaker················································································································· 1-1
1-3 During operation ················································································································································ 1-1
1-4 Disposing of the unit ········································································································································· 1-2
1-5 Others ······································································································································································ 1-2

2. Product Specifications ······························································································· 2-1


2-1 The Feature of Product ····································································································································· 2-1
2-2 Product Specifications ······································································································································ 2-2
2-3 The Comparative Specifications of Product····························································································· 2-3
2-4 Accessory and Option Specifications ········································································································· 2-4

3. Alignment and Adjustments ········································································ 3-1


3-1 Test Mode ······························································································································································· 3-1
3-2 Outdoor LED Display Error and Check Method ····················································································· 3-2
3-3 Setting Option Setup Method······················································································································· 3-4
3-4 Setting Option Setup Method······················································································································· 3-12

4. Disassembly and Reassembly ······································································ 4-1


4-1. Indoor Unit···························································································································································· 4-2
4-2. Outdoor Unit························································································································································ 4-12

5. Control Exploded Views And Part List ························································ 5-1


5-1 WIFI Case································································································································································· 5-1
5-2 ASSY Control In ·········································································································· ···································· 5-2
5-3 Assy Control Out ················································································································································ 5-3

6. Electrical Parts List ························································································ 6-1


6-1 INDOOR MAIN PCB (DB92-02873E) ············································· ···························································· 6-1
6-2 INDOOR SUB PBA(DB92-02874A)················································································································· 6-5
6-3 OUTDOOR MAIN PBA(DB92-02866A)-09K································································································· 6-6

7. Wiring Diagram ······························································································ 7-1


7-1 Indoor Unit····························································································································································· 7-1
7-2 Outdoor Unit ························································································································································ 7-2
7-3 ASSY WIFI KIT ························································································································································ 7-3

Samsung Electronics 1
Contents
8. PCB Diagram ·································································································· 8-1
8-1 Indoor Unit····························································································································································· 8-1
8-2 Outdoor PCB ························································································································································ 8-2
8-3 Wire connecting the indoor unit terminal blocks ················································································· 8-3

9. Operating Instructions·················································································· 9-1


9-1 Name of Each Part ·············································································································································· 9-1
9-2 Wireless Remote Control-Buttons and Display······················································································· 9-2

10. Troubleshooting ·························································································· 10-1


10-1 Items to be checked first ······························································································································· 10-1
10-2 Communication Error ····································································································································· 10-2
10-3 PCB Inspection Method ································································································································· 10-37
10-4 ASSY WIFI KIT Inspection Method ············································································································· 10-39

11. Block Diagram ····························································································· 11-1


11-1 Indoor unit ·························································································································································· 11-1
11-2 Outdoor unit······················································································································································· 11-2

12. Reference Sheet ··························································································· 12-1


12-1 Low Refrigerant Pressure Distribution····································································································· 12-1
12-2 Pressure & Capacity mark······························································································································ 12-1
12-3 Q & A for Non-trouble····································································································································· 12-2
12-4 Cleaning /Filter Change ································································································································· 12-5
12-5 Installation ··························································································································································· 12-6
12-6 Installation Diagram of Indoor Unit and Outdoor Unit ···································································· 12-7

2 Samsung Electronics
1. Precautions

1-1 Installing the air conditioner


O Uses should not install the air conditioner by themselves.
Ask the dealer or authorized company to install the air conditioner except window-type air conditioner in U.S.A and Canada.
O If you don't install the air conditioner properly, it may cause a fire, a water leakage or an electric shock.
O You must install the air conditioner according to the national wiring regulations and safety regulations.
O Install the indoor unit higher than 2.5m from the floor to avoid the injury caused by the operation of the fan.
(except the window-type air conditioner)
O The manufacturer is not responsible for any accidents or injury caused by an incorrect installation.
O When installing the built-in type air conditioner, keep all electric cables such as the power cable and the connection cord in
pipes, ducts, or cable channels to protect them from the danger of impact or any other incidents.

1-2 Power supply and circuit breaker


O If the power cord of the air conditioner is damaged, it must be replaced by the manufacturer or a qualified person in order
to avoid a hazard.
O The air conditioner must be plugged into an independent circuit if applicable or connect the power cable to the auxiliary circuit
breaker.
An all pole disconnection form the power supply must be incorporated in the fixed wiring with a contact opening of>3mm.
O Do not extend an electric cord to the air conditioner.
O The air conditioner must be plugged in after you complete the installation.

1-3 During operation

O Do not repair the air conditioner at your discretion.


It is recommended to contact a service center directly.
O Never spill any kind of liquid on the air conditioner.
If this happens, turn off the air conditioner and contact an authorized service center.
O Do not insert anything between the airflow blades to prevent damage of the inner fan and consequent injury.
Keep children away from the air conditioner.
O Do not place any obstacles in front of the air conditioner.
O Do not spray any kind of liquid into the indoor unit. If this happens, turn off the air conditioner and contact a service center.
O Make sure that the air conditioner is well ventilated at all times.
Do not place a cloth or other materials over it.
O Remove the batteries if you don't use the remote control for a long time. (If applicable)
O Use the remote control within 7 meters from the indoor unit. (If applicable)

Samsung Electronics 1-1


1-4 Disposing of the unit
O Before the throwing out the air conditioner, remove the batteries from the remote control.
O When you dispose of the air conditioner, consult your dealer. If pipes are removed incorrectly, refrigerant may blow out
and cause air pollution. When it contacts with your skin, it can cause skin injury.
O The package of the air conditioner should be recycled or disposed of properly for environmental reasons.

1-5 Others
O Never store or load the air conditioner upside down or sideways to prevent the damage to the compressor.
O Young children or infirm persons should be always supervised when they use the air conditioner.
O Max current is measured according to IEC standard for safety.
O Current is measured according to ISO standard for energy efficiency.

1-2 Samsung Electronics


2. Product Specifications

2-1 The Feature of Product

2 step cooling
- Get cool quickly and keep cool comfortably without shivering
Single user mode
- No worrying about the electricity bill, even using it when you're alone.
Crystal gloss design
- Uniquely stylish and innovative design to enhance your life and home
Smart Wi-Fi
- Control air conditioner anytime and anywhere
Smart Installation

Smart Check
- Don’t worry about the trouble-shooting in your home
Triple Protector Plus
- Use longer without damage in unsuitable conditions
Easy Installation
- Secure the easy Installation of Indoor unit and pipe connection
Easy Filter

Samsung Electronics 2-1


2-2
Development Development Development Development Development
MODEL
Model Model Model Model Model
ITEM AR09HSSFAWKNEU AR12HSSFAWKNEU AR09HSSFBWKNEU AR12HSSFBWKNEU AR12HSSFMWKNEU

Cooling/Heating W 220/550/780 220/940/1150 260/590/790 260/590/1150 220/880/1150


Power (low/std
(ISO) 180/750/1850 180/1050/2000 220/780/1550 220/1.05/1770 180/1000/2000
Consumption /max)
Cooling/Heating
- - - - -
(SASO)
2-2 Product Specifications

Cooling/Heating 1.4/2.7/3.7 1.4/4.4/5.2 1.4/3.2/3.8 1.4/4.8/5.2 1.4/4.4/5.2


A
Operating (ISO) 1.2/3.6/8.2 1.2/4.9/8.8 1.2/3.8/7 1.3/5.0/8.2 1.2/4.9/8.8
Current
Cooling/Heating
A - - - - -
(SASO)
70/90/95 70/90/95 70/90/95 70/90/95 70/90/95
Power Factor Cooling/Heating %
70/90/95 70/90/95 70/90/95 70/90/95 70/90/95
Indoor W*H*D(mm 936*270*264 936*270*264 936*270*264 936*270*264 936*270*264
Outer Dimension
Outdoor )
790*545*285 790*545*285 790*545*285 790*545*285 790*545*285
Indoor 12.6 12.6 12.6 12.6 12.6
Weight(net) Kg
Outdoor 35.5 35.5 35.5 35.5 35.5
Liquid 6.35 *7.5 6.35 *7.5 6.35 *7.5 6.35 *7.5 6.35 *7.5
Refrigerant Pipe mm*L(mm)
Gas 9.52*7.5 9.52*7.5 9.52*7.5 9.52*7.5 9.52*7.5
Drain Hose D*L(mm) ž20*550 ž20*550 ž20*550 ž20*550 ž20*550
2ROWx14STEPx635 2ROWx14STEPx635 2ROWx14STEPx635
Indoor 2ROWx14STEPx635 2ROWx14STEPx635
+1ROWx10STEPx635 +1ROWx10STEPx635 +1ROWx10STEPx635
Heat Exchanger
2ROWx24STEPx(850 2ROWx24STEPx(850 2ROWx24STEPx(850 2ROWx24STEPx(850 2ROWx24STEPx(850
Outdoor
+825) +825) +825) +825) +825)
Refrigerant g 1100 1100 1100 1100 1100
Freezer Oil Capacity cc - - - - -
Refrigerant Control Unit CAPILARRY CAPILARRY CAPILARRY CAPILARRY CAPILARRY
ROTARY ROTARY ROTARY ROTARY ROTARY
Compressor
UG9T115FUAEQSS UG9T115FUAEQSS UG9T115FUAEQSS UG9T115FUAEQSS UG9T115FUAEQSS
Protection device(OLP) NONE NONE NONE NONE NONE
Air purifying system - - - - -
Cooling Test Condition - - - - -
INDOOR -56 -56 -56 -56 -56
Cooling Operating Condition
OUTDOOR -39 -39 -39 -39 -39
INDOOR 27ć or less 27ć or less 27ć or less 27ć or less 27ć or less
Heating Operating Condition
-15ć-24ć -15ć-24ć -15ć-24ć -15ć-24ć -15ć-24ć

Samsung Electronics
MODEL AR09HSSFAWKNEU AR09HSSFBWKNEU AR12HSSFAWKNEU AR12HSSFBWKNEU AR12HSSFMWKNAX

Indoor Unit

Design

Indoor Unit 12.6 11.9 12.6 11.9 11.9


Weight
Outdoor unit 35.5 35.5 35.5 35.5 35.5
Indoor Unit 936*270*264 936*270*264 936*270*264 936*270*264 936*270*264
Outer Dimension
Outdoor unit 790*545*285 790*545*285 790*545*285 790*545*285 790*545*285
Indoor Unit 43/56 43/56 45/58 44/58 45/43
Noise
Outdoor unit 51/59 51/59 55/62 53/62 53
Air Purifying System Filter FULL HDFILTER FULL HDFILTER FULL HDFILTER FULL HDFILTER FULL HDFILTER

3 3
F

HOLDER DB61-06187A
3. Alignment and Adjustments

3-1 Test Mode

How to Approach Test Mode


You can approach the test mode by pressing the on/off switch of
indoor unit for 5 seconds.

Test mode operation option


After installing the air conditioner, check whether each subordinate is normally operated or not by operating the test mode.
ƽ When an Error occurs, display the Error Mode.

ƽ Operation Mode : Cool mode. operate the cool mode by operating the compressor by force without the compressor ON/OFF

according to the set temperature/indoor temperature. (Do not follow the antifreezecontrol)
ƽ Up-down louver : Up-down swing mode

ƽ Indoor Fan : Turbo

ƽ Because the teat mode operate the cool mode by force not related to the set temperature / indoor
temperature, check whether each subordinate is operated normally or not after completing installation
Note
and must turn off the power of the air conditioner.

Samsung Electronics 3-1


3-2 Display Error and Check Method

3-2-1 Indoor Display Error and Check Method


ER R O R M O D E D ES C R IP T IO N
E101 / E102 Communication Error (Indoor Outdoor)
E121 ROOM TH sensor error
E122 INDOOR MID, INDOOR IN PIPE-TH sensor error
E154 Fan Error (Indoor)
E162 EEPROM Error (Indoor)
E163 Option Error
E203 Time out Comm. (Inv Micom Main Micom)
E221 OUT-TH(Outdoor Temperature) Sensor Error
E231 CON-TH(Cond Temperature) Sensor Error
E251 DIS-TH(Discharge Temperature) Sensor Error
E416 DIS-TH(Discharge Temperature) Over Error
E422 EEV or Valve Close error-Self diagnosis
E440 Prohibit Operation Condition Error (Heating)
E441 Prohibit Operation Condition Error (Cooling)
E458 Fan Error(Outdoor)
E461 Comp Starting Error
E462 AC Input I_Limit Trip Error
E464 IPM Over Current(O.C) Error
E465 Comp V_limit/I_limit Error
E466 DC-Link Voltage Under/Over Error
E467 Comp Wire Missing Error
E468 Current Sensor Error
E469 DC-Link Voltage Sensor Error
E470 EEPROM Data Error (no data)
E471 EEPROM Data Error (Main Micom Inv Micom)
E474 Heatsink Sensor Error
E483 Over Voltage Protection Error
E484 PFC Over Load Error
E485 Input Current Sensor Error
E488 AC Input Voltage Sensor Error
E500 Heatsink Over Temperature Error
E554 Gas Leak Error

3-2 Samsung Electronics


Outdoor LED Display Error and Check Method

Samsung Electronics 3-3


3-3 Setting Option Setup Method(AR09(12)HSSFA(B)WK/EU)
ex) Option No. :

Note :
SEG1, SEG7, SEG13, SEG19 need not to be pressed in, so in fact the Option No. we should press in is as below.

SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24

SEG25 SEG26 SEG27 SEG28 SEG29 SEG30 SEG31 SEG32 SEG33 SEG34 SEG35 SEG36 SEG37 SEG38 SEG39 SEG40 SEG41 SEG42 SEG43 SEG44 SEG45 SEG46 SEG47 SEG48

Step 1

Enter the Option Setup mode.


1. Tack out the batteries of remote control.

2. Press the temperature button simultaneously and insert the battery again.

3. Make sure the remote control display shown as .

Step 2

Enter the Options Setup mode and select your options asscording to the following procedure.

Samsung Electronics 3-4


Step 3 Upon completion of the selection, check you made right selections.

Press the Mode Selection key to set the display part and check the display part.
ė The display part shows like below when each time you press Mode button.

Step 4 Pressing the ON/OFF button ( ) .

When pressing the operation ON/OFF key with the direction of remote control for unit, the sound ’’Ring’’ or ’
and the OPERATION ICON( ) lamp of the display is flickering at the same time, then the input of option is completed.
(If the deriving sound isn’t heard, try again pressing the ON/OFF button.)

3-5 Samsung Electronics


Step 5

Enter the Options Setup mode and select your options asscording to the following procedure.

Step 1 (Enter the Option Setup mode) is executed.


(Seg25 ~ 48 for setting remote control Setup)

Push the Mode button to set the display panerl to 2.

Every time you push the button, the display panel reads
. . . repeatedly.

Push the Mode button to set the display panerl to 1.

Every time you push the button, the display panel reads
. . . repeatedly.

Samsung Electronics 3-6


Model 1~6 7~12 13~18 19~24 49~54 55~60 61~66 67~72
AR09HSSFAWK/EU 012045 156A4A 271920 372937 033E3B 102432 200000 300000
AR09HSSFBWK/EU 012045 166A6B 272338 372B35 034744 10393E 200000 300000
AR12HSSFAWK/EU 012045 156A6B 272328 372A37 034645 10383E 200000 300000
AR12HSSFBWK/EU 012045 166A4A 271920 372A35 03403B 102432 200000 300000

7
Setting Option Setup Method(AR12HSSFMWK/AX)
ex) Option No. :

Note :
SEG1, SEG7, SEG13, SEG19 need not to be pressed in, so in fact the Option No. we should press in is as below.

SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24

SEG25 SEG26 SEG27 SEG28 SEG29 SEG30 SEG31 SEG32 SEG33 SEG34 SEG35 SEG36 SEG37 SEG38 SEG39 SEG40 SEG41 SEG42 SEG43 SEG44 SEG45 SEG46 SEG47 SEG48

Step 1

Enter the Option Setup mode.


1. Tack out the batteries of remote control.

2. Press the temperature button simultaneously and insert the battery again.

3. Make sure the remote control display shown as .

Step 2

Enter the Options Setup mode and select your options asscording to the following procedure.

Samsung Electronics 3-8


Step 3 Upon completion of the selection, check you made right selections.

Press the Mode Selection key to set the display part and check the display part.
ė The display part shows like below when each time you press Mode button.

Step 4 Pressing the ON/OFF button ( ) .

When pressing the operation ON/OFF key with the direction of remote control for unit, the sound ’’Ding’’ or ’
and the OPERATION ICON( ) lamp of the display is flickering at the same time, then the input of option is completed.
(If the deriving sound isn’t heard, try again pressing the ON/OFF button.)

3-9 Samsung Electronics


Step 5

Enter the Options Setup mode and select your options asscording to the following procedure.

Step 1 (Enter the Option Setup mode) is executed.


(Seg25 ~ 48 for setting remote control Setup)

Push the Mode button to set the display panerl to 2.

Every time you push the button, the display panel reads
. . . repeatedly.

Push the Mode button to set the display panerl to 1.

Every time you push the button, the display panel reads
. . . repeatedly.

Samsung Electronics 3-10


Model 1~6 7~12 13~18 19~24 49~54 55~60 61~66 67~72
AR12HSSFMWK/AX 012045 156A6B 272328 372A34 034645 10383E 200000 300000

11
3-12
Download connector
(10pin)

3-13
4. Disassembly and Reassembly

Q Necessary Tools

Item Remark

+SCREW DRIVER

MONKEY SPANNER

- SCREW DRIVER

Samsung Electronics 4-1


4-1. Indoor Unit

No Parts Proced ure Rem ark

1 PANEL-FRONT 1) Stop the driving of air conditioner


and shut off main power supply.

2) Detach FILTER PRE from the PANEL


FRONT.

3) Cover Panel is assembled on bottom


of indoor unit as shown in the figure.
Remove the Cap Screw as shown on the
right side and then remove the screw
and seperate the Cover Panel.

4-2 Samsung Electronics


No Parts Proced ure Rem ark

4) Cover Panel is fixed to body by Hook


in center area and side area.
Center area

Side area Side area

HOOK

5) Separate the hook after pushing both


end of Cover Panel as shown in the figure.
(Watch out for the damage of the hook)

6) Raise front part upward obliquely


as shown in the figure and then remove
the hooks.

Samsung Electronics 4-3


No Parts Proced ure Rem ark

Caution:
Assembly of Cover Panel after service end.
- Reassembly is in the reverse order
of the removal.
- Piping and drain hose must be careful not to
damage and Progress must be done with
both hands.

Hook (Side)

Hook (Center)

Screw

Cap Screw

4-4 Samsung Electronics


No Parts Proced ure Rem ark

˅ Door is assembled to the panel front


by two screws.Remove the two screws as
shown in the figure.Take out of the
cover two screws mocha-left and right
in the correct direction.Get out of
the door in the figure.Remove the
screw and seperate hanger.

4-5 Samsung Electronics


No Parts Proced ure Rem ark

8) Use the drive to remove the screw of


cover panel-sub. Take out of cover
panel-sub.

9) To detach the COVER-PANEL from the main


frame, loosen 4 HOOK Structures.
When separate the hook :
Use the (-) screw Driver.
(-)Screw Driver Insert the hook and
then pull the hook as shown on the
right side.
(Watch out for the damage of the hook)

4-6 Samsung Electronics


No Parts Proced ure Rem ark

4-7 Samsung Electronics


No Parts Proced ure Rem ark

2 TRAY DRAIN 1) Before detaching TRAY-DRAIN from the


main frame,you should detach assy
plate-control first and seperate the
connecting line.
Pull the bottom of the TRAY DRAIN
towards you.

4-8 Samsung Electronics


No Parts Proced ure Rem ark

3 CONTROL IN 1) Take off the CASE-CONTROL from


the main frame after loosen the remaining
connector.

Caution:
When you separate the connector,
pull pressing the locking button.

4 EVAPORATOR 1) detach the holder pipe

2) Unfasten the screw at the left side.


(use + Screw Driver)

4-9 Samsung Electronics


No Parts Proced ure Rem ark

3) Unfasten the screw at the right side.


(use + Screw Driver)

4) To detach Evaporator from the main


frame, pull the bottom of the
Evaporator towards you.

5 FAN MOTOR 1) Unfasten the screw. (use + Screw Driver)


&
CROSS FAN

2) Detach the FAN Motor case.

Samsung Electronics 4-10


No Parts Proced ure Rem ark

3) Unfasten the screw a little.


(use + Screw Driver)

4) Pull the CROSS-FAN to the left side.

6 Assy SPI Lamp 1) Remove the Assy SPI Lamp from the Back
Body as shown on the right side.
C au tion :
- Confirm Seal of backside necessarily
after replace of Assy SPI Lamp.
- Seal should be close adhesion to SPI
Lamp.
- Measure as shown on the right side
replace.
(If the seal is not close adhesion
perfectly : Defectiveness can happen)

4-11 Samsung Electronics


4-2 Outdoor Unit

3) Detach the Cabinet Upper like the picture.

4-2-1
5) Loosen 2 screw(CCW) on the right side of
Cabinet Front. (Use +Screw Driver)

6) Loosen 2 screw(CCW) on the left side of


Cabinet Front. (Use +Screw Driver)

7) Loosen 3 screw(CCW) on the front side of


Cabinet Front. (Use +Screw Driver)

4-2-2
8 3


4-2-4
1) Release Nut at Fan Boss
2) Release 3 screws st Motor Bracket.
3) Detach Motor Wire from the Assy Control Out.

4-2-5
5. Disassembly WIFI

5-1 WIFI Case


No Parts Pro ced u re Rem ark

1 CASE Separate Case-WIFI Top


from Case-WIFI Button

2 BUTTON Separate Case-WIFI Top


from Case-WIFI Button

Detach Assy Connector


Wire from Case-WIFI Button

3 WIRE *Caution
When you separate the
connector , pull press
-ing the locking button

Separate PBA WIFI from


4 PBA Case-WIFI Button

Samsung Electronics 5-1


5-2 ASSY CONTROL IN

25 10 5 6 7 9 8

26
31

30

3 27

32
20 4

33

34
29

24

1
2 23 11 28 35
21 22

12
36

13

19

14

18 17 16 15

No CODE Description Spec Q'TY


DB93-14734Y ASSY CONTROL IN
1 DB63-03553C Aluminum SHEET 10x10xT0.07,AL SHEET 4
2 DB61-05826A CASE-CONTROL IN CASE-CONTROL IN 1
3 DB93-14203A POWER WIRE T/B-main(power) 1
4 DB93-14245A EARTH WIRE EARTH WIRE 1
5 DB65-00326A TERMINAL BLOCK TERMINAL BLOCK 1
6 DB62-11656F SEAL CUTT PVC,BLACK,T1,W54 1
7 DB62-11680A SEAL CONTROL FLOCKED,BLACK,T1,W50,54 1
8 DB68-02809A ASSY-LABEL ASSY-LABEL 1
9 DB93-14447A COMMUNICATION WIRE T/B-main(485) 1
10 DB93-14207A FUSE WIRE power-main(12V 5V) 1
11 DB63-03553D Aluminum SHEET 22x22xT0.07,AL SHEET 1
12 DB68-33293A ASSY-LABEL ASSY-LABEL 1
13 DB61-05807A PLATE-CONTROL IN F01 1
14 DB68-33292A ASSY-LABEL ASSY-LABEL 1
15 DB91-00309A SCREW M3,L25,ZPC(WHT),SWRCH18Aϔ 1
16 DB61-05812A PLATE PLATE 1
17 6009-001001 SCREW TH,M4,L10,ZPC(WHT),SWRCH18Aϔ 3
18 6002-000231 SCREW M4,L12,ZPC(WHT),SWRCH18Aϔ 2
19 DB61-05871A HOLDER-WIRE CLAMP HOLDER-WIRE CLAMP 1
20 DB92-02873A MAIN PBA STD4 1
21 DB92-02861A POWER PBA STD11W 1
22 DB62-11793A SEAL CASE-LEFT SEAL CASE-LEFT 1
23 DB93-14208A ASSY CONNECTOR WIRE-DC power-main(310V 19V) 1
24 DB95-05163A ASSY THERMISTOR IN sensor 1roomˈ2evap 1
25 DB93-14221A ASSY CONNECTOR WIRE-DC FJM 1
26 DB93-14202A ASSY CONNECTOR WIRE-DC main-power(SMPS IN) 1
27 DB93-14205A ASSY CONNECTOR WIRE-DC Step-main(Left) 1
28 DB93-14211A ASSY CONNECTOR WIRE-DC WIFI 1
29 DB93-14541A ASSY CONNECTOR WIRE-DC TSET WIRE 1
30 DB93-14217A ASSY CONNECTOR WIRE-DC GRILL MOTOR WIRE 1
31 DB93-14724A ASSY CONNECTOR WIRE-DC BLDC 1
32 DB93-14209A ASSY CONNECTOR WIRE-DC DISPLAY MOTOR 1
33 DB93-14723A ASSY CONNECTOR WIRE-DC STEP MOTOR 1
34 DB61-05965A PLATE CONTROL-UP PLATE CONTROL-UP 1
35 DB93-04695A ASSY CONNECTOR WIRE-DC SPI 1
36 DB90-07859A ASSY PLATE CONTROL RIGHT 1

5-2 Samsung Electronics


5-3 Assy Control Out
AR09HSSDBWKXEU
AR12HSSDBWKXEU

No NAME CODE Q'ty unit


1 GREASE-SILICON 0205-000178 0.002 KG
2 SCREW-TAPPING 6002-000527 1 PC
3 SCREW-TAPPING 6002-000536 1 PC
4 HEAT SINK DB62-11646A 1 PC
5 SEAL CUTT DB62-11656B 0 M
6 CABLE TIE DB65-10088B 2 PC
7 LABEL BAR CODE DB68-02809A 1 PC
8 ASSY CASE CONTROL OUT DB90-06308N 1 PC
9 ASSY COVER CONTROL-UP DB90-07729A 1 PC
10 ASSY CASE CONTROL DB90-07833A 1 PC
11 ASSY-SCREW MACHINE DB91-00933A 4 PC
12 ASSY MODULE DB92-02862A 1 PC
13 ASSY PCB MAIN DB92-02866A 1 PC
14 ASSY CONNECTOR WIRE DB93-09493C 1 PC
15 ASSY CONNECTOR WIRE DB93-09497E 1 PC
16 ASSY CONNECTOR WIRE-POWER DB93-14275A 1 PC
17 ASSY CONNECTOR WIRE-DC SIGNDB93-14276A 1 PC
18 ASSY CONNECTOR WIRE-DC SIGNDB93-14277A 1 PC

5-3 Samsung Electronics


6. Electrical Parts List

6-1 INDOOR MAIN PCB (DB92-02873A)


Parts Code Design Loc Parts Dsecription Quantity
Q701 TR-POWER 1
1405-001239 VA71 VARISTOR 1
2301-002032 XC71 C-FILM,LEAD-PPF 1
2301-002032 XC72 C-FILM,LEAD-PPF 1
3002-001139 BZ61 BUZZER-PIEZO 1
3711-000177 CN21 HEADER-BOARD TO CABLE 1
3711-000203 CN75 HEADER-BOARD TO CABLE 1
3711-000296 CN72 HEADER-BOARD TO CABLE 1
3711-002001 CN31 HEADER-BOARD TO CABLE 1
3711-003404 CN71 HEADER-BOARD TO CABLE 1
3711-003845 CN91 HEADER-BOARD TO CABLE 1
3711-004122 CN32 HEADER-BOARD TO CABLE 1
3711-004236 CN43 HEADER-BOARD TO CABLE 1
3711-005096 CN63 HEADER-BOARD TO CABLE 1
3711-005097 CN62 HEADER-BOARD TO CABLE 1
3711-005504 CN51 HEADER-BOARD TO CABLE 1
DB27-00096A FT71 COIL CHOKE 1
DB67-00942A VA71-1 CAP 1
DB68-02809A LABEL BAR CODE LABEL BAR CODE 1
DB94-04097A ASSY PCB AUTO 1
0501-000362 Q801 TR-SMALL SIGNAL 1
1404-001194 PTC2 THERMISTOR-PTC 1
3601-001765 F701 FUSE-ETC 1
3711-000024 CN76 HEADER-BOARD TO CABLE 1
3711-000941 CN81 HEADER-BOARD TO CABLE 1
3711-000998 CN77 CONNECTOR-HEADER 1
3711-000999 CN61 HEADER-BOARD TO CABLE 1
DB94-04098A ASSY PCB SMD 1
0402-001741 D701 DIODE-RECTIFIER 1
0406-001204 CD81 DIODE-TVS 1
0406-001204 CD82 DIODE-TVS 1
0406-001204 CD83 DIODE-TVS 1
0501-000465 Q702 TR-SMALL SIGNAL 1
0504-001080 Q601 TR-DIGITAL 1
0504-001080 Q802 TR-DIGITAL 1
0506-000175 IC05 TR-ARRAY 1
0506-000175 IC06 TR-ARRAY 1
0604-001002 PC03 PHOTO-COUPLER 1
0604-001002 PC04 PHOTO-COUPLER 1
0604-001002 PC05 PHOTO-COUPLER 1
0801-000393 IC08 IC-CMOS LOGIC 1
1006-001325 IC07 IC-BUS TRANSCEIVER 1
1202-000104 IC11 IC-VOLTAGE COMP. 1
1203-006245 IC03 IC-VOL. DETECTOR 1
1203-007526 IC02 IC-POSI.FIXED REG. 1
2007-000029 R850 R-CHIP 1
2007-000029 R851 R-CHIP 1
2007-000067 R713 R-CHIP 1
2007-000072 R717 R-CHIP 1

Samsung Electronics 6-1


INDOOR MAIN PCB (DB92-02873A) cont.

2007-000076 R601 R-CHIP 1


2007-000076 R602 R-CHIP 1
2007-000076 R716 R-CHIP 1
2007-000078 R703 R-CHIP 1
2007-000078 R706 R-CHIP 1
2007-000078 R805 R-CHIP 1
2007-000078 R815 R-CHIP 1
2007-000084 R707 R-CHIP 1
2007-000087 R708 R-CHIP 1
2007-000090 R701 R-CHIP 1
2007-000090 R704 R-CHIP 1
2007-000090 R705 R-CHIP 1
2007-000090 R723 R-CHIP 1
2007-000090 R801 R-CHIP 1
2007-000090 R802 R-CHIP 1
2007-000090 R803 R-CHIP 1
2007-000090 R804 R-CHIP 1
2007-000090 R816 R-CHIP 1
2007-000116 R825 R-CHIP 1
2007-000130 R715 R-CHIP 1
2007-000138 R508 R-CHIP 1
2007-000138 R515 R-CHIP 1
2007-000138 R516 R-CHIP 1
2007-000138 R517 R-CHIP 1
2007-000138 R518 R-CHIP 1
2007-000138 R519 R-CHIP 1
2007-000138 R520 R-CHIP 1
2007-000138 R539 R-CHIP 1
2007-000138 R542 R-CHIP 1
2007-000138 R809 R-CHIP 1
2007-000140 R538 R-CHIP 1
2007-000140 R545 R-CHIP 1
2007-000140 R806 R-CHIP 1
2007-000140 R901 R-CHIP 1
2007-000143 R511 R-CHIP 1
2007-000143 R512 R-CHIP 1
2007-000143 R513 R-CHIP 1
2007-000148 R502 R-CHIP 1
2007-000148 R503 R-CHIP 1
2007-000148 R504 R-CHIP 1
2007-000148 R505 R-CHIP 1
2007-000148 R506 R-CHIP 1
2007-000148 R507 R-CHIP 1
2007-000148 R510 R-CHIP 1
2007-000148 R521 R-CHIP 1
2007-000148 R522 R-CHIP 1
2007-000148 R523 R-CHIP 1
2007-000148 R524 R-CHIP 1
2007-000148 R525 R-CHIP 1
2007-000148 R526 R-CHIP 1

6-2 Samsung Electronics


INDOOR MAIN PCB (DB92-02873A)

2007-000148 R527 R-CHIP 1


2007-000148 R528 R-CHIP 1
2007-000148 R529 R-CHIP 1
2007-000148 R530 R-CHIP 1
2007-000148 R531 R-CHIP 1
2007-000148 R532 R-CHIP 1
2007-000148 R533 R-CHIP 1
2007-000148 R534 R-CHIP 1
2007-000148 R543 R-CHIP 1
2007-000148 R544 R-CHIP 1
2007-000148 R807 R-CHIP 1
2007-000148 R808 R-CHIP 1
2007-000148 R810 R-CHIP 1
2007-000148 R824 R-CHIP 1
2007-000148 R903 R-CHIP 1
2007-000148 R904 R-CHIP 1
2007-000157 R902 R-CHIP 1
2007-000162 R820 R-CHIP 1
2007-000162 R821 R-CHIP 1
2007-000171 R831 R-CHIP 1
2007-000171 R833 R-CHIP 1
2007-000171 R835 R-CHIP 1
2007-000171 R837 R-CHIP 1
2007-000171 R839 R-CHIP 1
2007-000171 R843 R-CHIP 1
2007-000303 R702 R-CHIP 1
2007-000385 R115 R-CHIP 1
2007-000455 R712 R-CHIP 1
2007-000475 R709 R-CHIP 1
2007-000924 R112 R-CHIP 1
2007-000924 R113 R-CHIP 1
2007-000924 R114 R-CHIP 1
2007-000939 R711 R-CHIP 1
2007-001096 R714 R-CHIP 1
2007-001313 R404 R-CHIP 1
2007-001313 R405 R-CHIP 1
2007-001313 R406 R-CHIP 1
2007-001313 R410 R-CHIP 1
2007-001313 R811 R-CHIP 1
2007-001433 R618 R-CHIP 1
2007-007313 R401 R-CHIP 1
2007-007313 R402 R-CHIP 1
2007-007313 R403 R-CHIP 1
2007-009922 R301 R-CHIP 1
2007-009922 R302 R-CHIP 1
2007-009922 R303 R-CHIP 1
2203-000257 C705 C-CER,CHIP 1
2203-000257 C801 C-CER,CHIP 1
2203-000438 C508 C-CER,CHIP 1
2203-000438 C516 C-CER,CHIP 1

6-3 Samsung Electronics


INDOOR MAIN PCB (DB92-02873A) `c̀ont.

2203-000438 C520 C-CER,CHIP 1


2203-000438 C901 C-CER,CHIP 1
2203-000440 C711 C-CER,CHIP 1
2203-000440 C715 C-CER,CHIP 1
2203-001071 C519 C-CER,CHIP 1
2203-005249 C401 C-CER,CHIP 1
2203-005249 C402 C-CER,CHIP 1
2203-005249 C403 C-CER,CHIP 1
2203-005249 C511 C-CER,CHIP 1
2203-005249 C513 C-CER,CHIP 1
2203-005249 C514 C-CER,CHIP 1
2203-005249 C517 C-CER,CHIP 1
2203-005249 C522 C-CER,CHIP 1
2203-005249 C529 C-CER,CHIP 1
2203-005249 C530 C-CER,CHIP 1
2203-005249 C531 C-CER,CHIP 1
2203-005249 C533 C-CER,CHIP 1
2203-005249 C702 C-CER,CHIP 1
2203-005249 C704 C-CER,CHIP 1
2203-005249 C710 C-CER,CHIP 1
2203-005249 C712 C-CER,CHIP 1
2203-005249 C713 C-CER,CHIP 1
2203-005249 C802 C-CER,CHIP 1
2203-005249 C803 C-CER,CHIP 1
2203-005249 C805 C-CER,CHIP 1
2203-005249 C806 C-CER,CHIP 1
2203-005249 C807 C-CER,CHIP 1
2203-005249 C809 C-CER,CHIP 1
2203-006496 C707 C-CER,CHIP 1
2203-006960 C708 C-CER,CHIP 1
2203-007486 C509 C-CER,CHIP 1
2203-007486 C512 C-CER,CHIP 1
2203-007486 C515 C-CER,CHIP 1
2203-007486 C518 C-CER,CHIP 1
2203-007486 C521 C-CER,CHIP 1
2203-007486 C523 C-CER,CHIP 1
2203-007486 C526 C-CER,CHIP 1
2203-007486 C528 C-CER,CHIP 1
2203-007486 C551 C-CER,CHIP 1
2203-007486 C552 C-CER,CHIP 1
2203-007486 C804 C-CER,CHIP 1
2203-007486 C808 C-CER,CHIP 1
2402-000120 C706 C-AL,SMD 1
2402-001145 C701 C-AL,SMD 1
2402-001145 C703 C-AL,SMD 1
2802-001211 X501 RESONATOR-CERAMIC 1
DB41-01221A PCB MAIN PCB MAIN 1
DB91-01550A IC04 ASSY MICOM 1
0903-001864 - IC-MICROCONTROLLER 1
DB98-31449A ASSY-LABEL MICOM ASSY-LABEL MICOM 1

6-4 Samsung Electronics


6-2 INDOOR SUB PBA(DB92-02874A)

Parts Code Design Loc Parts Description Quantity


0609-001377 RM01 MODULE REMOCON 1
3711-004067 CN01 HEADER-BOARD TO CABLE 1
DB63-03547A COVER-SENSOR COVER-SENSOR 1
DB94-04100A - ASSY PCB SMD 1
0406-001005 CD01 DIODE-TVS 1
2007-000029 J1 R-CHIP 1
2007-000290 R01 R-CHIP 1
2203-000206 C03 C-CER,CHIP 1
2203-000444 C02 C-CER,CHIP 1
DB94-04099A - ASSY PCB AUTO 1
2401-003107 C01 C-AL 1
3404-001220 SW01 SWITCH-TACT 1
DB41-01222A PCB SUB PCB SUB 1

Samsung Electronics 6-5


OUTDOOR MAIN PBA(DB92-02866A) - (cont.)

modelCode Design Loc Parts Description Quantity


0202-001338 SOLDER-BAR SOLDER-BAR 0.47
0202-001463 SOLDER-WIRE SOLDER-WIRE 4.27
0204-004665 FLUX FLUX 0.43
0204-005794 SOLVENT SOLVENT 1
1404-001498 PTC020 THERMISTOR-PTC 1
1405-000154 VA002 VARISTOR 1
1405-000154 VA003 VARISTOR 1
1405-001239 VA001 VARISTOR 1
1405-001239 VA401 VARISTOR 1
2201-000540 C425 C-CERAMIC,DISC 1
2201-002002 C004 C-CERAMIC,DISC 1
2201-002002 C005 C-CERAMIC,DISC 1
2201-002002 C012 C-CERAMIC,DISC 1
2201-002002 C013 C-CERAMIC,DISC 1
2301-001285 C001 C-FILM,LEAD-PPF 1
2301-001285 C006 C-FILM,LEAD-PPF 1
2306-000123 C412 C-FILM,LEAD-PPF 1
2401-004874 CE101 C-AL 1
2401-004874 CE102 C-AL 1
2401-004874 CE103 C-AL 1
3501-001154 RY022 RELAY-MINIATURE 1
3501-001154 RY030 RELAY-MINIATURE 1
3501-001279 RY021 RELAY-POWER 1
3711-000177 CN301 HEADER-BOARD TO CABLE 1
3711-000203 CN030 HEADER-BOARD TO CABLE 1
3711-000296 CN901 HEADER-BOARD TO CABLE 1
3711-000760 CN551 HEADER-BOARD TO CABLE 1
3711-002001 CN201 HEADER-BOARD TO CABLE 1
3711-003404 CN150 HEADER-BOARD TO CABLE 1
3711-003843 CN251 HEADER-BOARD TO CABLE 1
3711-007656 CN402 HEADER-BOARD TO CABLE 1
3711-007659 CN401 HEADER-BOARD TO CABLE 1
3711-007817 CN501 HEADER-BOARD TO BOARD 1
3712-001047 CN003 CONNECTOR-TERMINAL 1
3712-001139 CN001 CONNECTOR-TERMINAL 1
3712-001139 CN002 CONNECTOR-TERMINAL 1
4719-002483 PFC050 POWER MODULE 1
4719-002484 IPM400 POWER MODULE 1
DB27-00097A FT001 COIL CHOKE 1
DB61-05296A SUPPORT-IC SUPPORT-IC 1
DB61-05916A SUPPORT-PCB SUPPORT-PCB 1
DB68-02809A - LABEL BAR CODE 1
DB94-04084A ASSY PCB AUTO 1
0504-001044 Q151 TR-DIGITAL 1
2201-002427 C901 C-CERAMIC,DISC 1
2401-000303 CE162 C-AL 1
2401-000303 CE163 C-AL 1
2401-001838 CE151 C-AL 1
2401-002438 CE902 C-AL 1

6-6 Samsung Electronics


OUTDOOR MAIN PBA(DB92-02866A) - (cont.)

2401-003224 CE152 C-AL 1


2401-003585 CE901 C-AL 1
3601-001538 F001 FUSE-AXIAL LEAD 1
3711-000015 CN203 HEADER-BOARD TO CABLE 1
3711-000024 CN202 HEADER-BOARD TO CABLE 1
3711-000879 CN152 HEADER-BOARD TO CABLE 1
3711-000880 CN151 HEADER-BOARD TO CABLE 1
3711-000998 CN701 CONNECTOR-HEADER 1
3711-000999 CN204 HEADER-BOARD TO CABLE 1
4715-001093 DSA001 SURGE ABSORBER 1
DB94-04085A ASSY PCB SMD 1
0202-001459 SOLDER-CREAM SOLDER-CREAM 1
0401-001099 D020 DIODE-SWITCHING 1
0401-001099 D021 DIODE-SWITCHING 1
0401-001099 D030 DIODE-SWITCHING 1
0401-001099 D152 DIODE-SWITCHING 1
0401-001099 D153 DIODE-SWITCHING 1
0401-001099 D454 DIODE-SWITCHING 1
0401-001099 D500 DIODE-SWITCHING 1
0401-001099 D501 DIODE-SWITCHING 1
0401-001099 D502 DIODE-SWITCHING 1
0401-001099 D503 DIODE-SWITCHING 1
0401-001099 D504 DIODE-SWITCHING 1
0401-001099 D505 DIODE-SWITCHING 1
0401-001099 D507 DIODE-SWITCHING 1
0401-001099 D508 DIODE-SWITCHING 1
0401-001099 D904 DIODE-SWITCHING 1
0401-001099 D905 DIODE-SWITCHING 1
0402-001795 D903 DIODE-RECTIFIER 1
0403-001499 ZD401 DIODE-ZENER 1
0403-001499 ZD420 DIODE-ZENER 1
0404-001020 D491 DIODE-SCHOTTKY 1
0404-001020 D492 DIODE-SCHOTTKY 1
0406-001204 TD301 DIODE-TVS 1
0406-001204 TD302 DIODE-TVS 1
0406-001204 TD303 DIODE-TVS 1
0501-000465 Q551 TR-SMALL SIGNAL 1
0504-001008 Q351 TR-DIGITAL 1
0504-001008 Q352 TR-DIGITAL 1
0504-001008 Q901 TR-DIGITAL 1
0504-001008 Q903 TR-DIGITAL 1
0504-001080 Q902 TR-DIGITAL 1
0506-000175 IC061 TR-ARRAY 1
0506-000175 IC701 TR-ARRAY 1
0506-000175 IC702 TR-ARRAY 1
0601-002423 LED801 LED 1
0601-002955 LED803 LED 1
0601-002956 LED551 LED 1
0601-002956 LED802 LED 1
0604-001172 PC151 PHOTO-COUPLER 1

6-7 Samsung Electronics


OUTDOOR MAIN PBA(DB92-02866A) (cont.)

0604-001172 PC351 PHOTO-COUPLER 1


0604-001172 PC352 PHOTO-COUPLER 1
0801-000393 IC302 IC-CMOS LOGIC 1
1006-001325 IC301 IC-BUS TRANSCEIVER 1
1201-002946 IC451 IC-OP AMP 1
1203-002835 IC154 IC-POSI.FIXED REG. 1
1203-002986 IC155 IC-POSI.FIXED REG. 1
1203-004967 IC502 IC-VOL. DETECTOR 1
2007-000043 R424 R-CHIP 1
2007-000070 R309 R-CHIP 1
2007-000074 R152 R-CHIP 1
2007-000074 R210 R-CHIP 1
2007-000074 R213 R-CHIP 1
2007-000074 R233 R-CHIP 1
2007-000074 R234 R-CHIP 1
2007-000074 R401 R-CHIP 1
2007-000074 R402 R-CHIP 1
2007-000074 R403 R-CHIP 1
2007-000074 R404 R-CHIP 1
2007-000074 R405 R-CHIP 1
2007-000074 R406 R-CHIP 1
2007-000074 R407 R-CHIP 1
2007-000074 R420 R-CHIP 1
2007-000074 R422 R-CHIP 1
2007-000074 R516 R-CHIP 1
2007-000074 R519 R-CHIP 1
2007-000074 R562 R-CHIP 1
2007-000076 R153 R-CHIP 1
2007-000076 R255 R-CHIP 1
2007-000076 R256 R-CHIP 1
2007-000076 R257 R-CHIP 1
2007-000076 R258 R-CHIP 1
2007-000076 R352 R-CHIP 1
2007-000076 R353 R-CHIP 1
2007-000076 R512 R-CHIP 1
2007-000076 R567 R-CHIP 1
2007-000076 R904 R-CHIP 1
2007-000078 R303 R-CHIP 1
2007-000078 R307 R-CHIP 1
2007-000078 R308 R-CHIP 1
2007-000078 R351 R-CHIP 1
2007-000078 R354 R-CHIP 1
2007-000078 R503 R-CHIP 1
2007-000078 R504 R-CHIP 1
2007-000078 R505 R-CHIP 1
2007-000078 R508 R-CHIP 1
2007-000078 R509 R-CHIP 1
2007-000078 R515 R-CHIP 1
2007-000078 R529 R-CHIP 1
2007-000078 R530 R-CHIP 1

6-8 Samsung Electronics


OUTDOOR MAIN PBA(DB92-02866A) - (cont.)

2007-000078 R556 R-CHIP 1


2007-000078 R557 R-CHIP 1
2007-000078 R558 R-CHIP 1
2007-000078 R560 R-CHIP 1
2007-000078 R563 R-CHIP 1
2007-000080 R522 R-CHIP 1
2007-000082 R421 R-CHIP 1
2007-000084 R211 R-CHIP 1
2007-000084 R212 R-CHIP 1
2007-000084 R214 R-CHIP 1
2007-000084 R215 R-CHIP 1
2007-000084 R216 R-CHIP 1
2007-000084 R217 R-CHIP 1
2007-000084 R218 R-CHIP 1
2007-000084 R219 R-CHIP 1
2007-000084 R220 R-CHIP 1
2007-000084 R408 R-CHIP 1
2007-000084 R501 R-CHIP 1
2007-000084 R506 R-CHIP 1
2007-000084 R507 R-CHIP 1
2007-000084 R510 R-CHIP 1
2007-000084 R511 R-CHIP 1
2007-000084 R517 R-CHIP 1
2007-000084 R518 R-CHIP 1
2007-000084 R520 R-CHIP 1
2007-000084 R521 R-CHIP 1
2007-000084 R523 R-CHIP 1
2007-000084 R524 R-CHIP 1
2007-000084 R525 R-CHIP 1
2007-000084 R526 R-CHIP 1
2007-000084 R527 R-CHIP 1
2007-000084 R534 R-CHIP 1
2007-000084 R535 R-CHIP 1
2007-000084 R536 R-CHIP 1
2007-000084 R903 R-CHIP 1
2007-000090 R301 R-CHIP 1
2007-000090 R302 R-CHIP 1
2007-000090 R304 R-CHIP 1
2007-000090 R305 R-CHIP 1
2007-000090 R528 R-CHIP 1
2007-000090 R532 R-CHIP 1
2007-000090 R533 R-CHIP 1
2007-000090 R551 R-CHIP 1
2007-000090 R552 R-CHIP 1
2007-000090 R553 R-CHIP 1
2007-000090 R554 R-CHIP 1
2007-000090 R555 R-CHIP 1
2007-000090 R559 R-CHIP 1
2007-000090 R565 R-CHIP 1
2007-000109 R531 R-CHIP 1

6-9 Samsung Electronics


OUTDOOR MAIN PBA(DB92-02866A) - (cont.)

2007-000116 R306 R-CHIP 1


2007-000124 R564 R-CHIP 1
2007-000140 R202 R-CHIP 1
2007-000140 R205 R-CHIP 1
2007-000143 R207 R-CHIP 1
2007-000143 R221 R-CHIP 1
2007-000143 R222 R-CHIP 1
2007-000143 R223 R-CHIP 1
2007-000143 R224 R-CHIP 1
2007-000143 R225 R-CHIP 1
2007-000143 R226 R-CHIP 1
2007-000143 R227 R-CHIP 1
2007-000143 R228 R-CHIP 1
2007-000143 R229 R-CHIP 1
2007-000143 R230 R-CHIP 1
2007-000143 R231 R-CHIP 1
2007-000143 R232 R-CHIP 1
2007-000148 R203 R-CHIP 1
2007-000148 R204 R-CHIP 1
2007-000148 R206 R-CHIP 1
2007-000170 R201 R-CHIP 1
2007-000239 R491 R-CHIP 1
2007-000256 R455 R-CHIP 1
2007-000256 R457 R-CHIP 1
2007-000256 R468 R-CHIP 1
2007-000300 R901 R-CHIP 1
2007-000385 R101 R-CHIP 1
2007-000385 R105 R-CHIP 1
2007-000455 R251 R-CHIP 1
2007-000455 R253 R-CHIP 1
2007-000491 R561 R-CHIP 1
2007-000536 R492 R-CHIP 1
2007-000537 R154 R-CHIP 1
2007-000537 R155 R-CHIP 1
2007-000537 R156 R-CHIP 1
2007-000537 R157 R-CHIP 1
2007-000537 R158 R-CHIP 1
2007-000614 R252 R-CHIP 1
2007-000614 R254 R-CHIP 1
2007-000614 R469 R-CHIP 1
2007-000614 R470 R-CHIP 1
2007-000614 R471 R-CHIP 1
2007-000614 R472 R-CHIP 1
2007-000614 R473 R-CHIP 1
2007-000614 R474 R-CHIP 1
2007-000651 R475 R-CHIP 1
2007-000683 R454 R-CHIP 1
2007-000683 R459 R-CHIP 1
2007-000683 R466 R-CHIP 1
2007-000763 R476 R-CHIP 1

6-10 Samsung Electronics


OUTDOOR MAIN PBA(DB92-02866A) - (cont.)

2007-000763 R477 R-CHIP 1


2007-000872 R801 R-CHIP 1
2007-000872 R802 R-CHIP 1
2007-000872 R803 R-CHIP 1
2007-000924 R102 R-CHIP 1
2007-000924 R103 R-CHIP 1
2007-000924 R104 R-CHIP 1
2007-000924 R106 R-CHIP 1
2007-000924 R107 R-CHIP 1
2007-000924 R108 R-CHIP 1
2007-000979 R478 R-CHIP 1
2007-001071 R902 R-CHIP 1
2007-001175 R409 R-CHIP 1
2007-001175 R423 R-CHIP 1
2007-001175 R427 R-CHIP 1
2007-010245 R410 R-CHIP 1
2007-010245 R411 R-CHIP 1
2007-010245 R412 R-CHIP 1
2007-010245 R425 R-CHIP 1
2007-010245 R426 R-CHIP 1
2203-000236 C421 C-CER,CHIP 1
2203-000257 C222 C-CER,CHIP 1
2203-000257 C223 C-CER,CHIP 1
2203-000257 C224 C-CER,CHIP 1
2203-000257 C225 C-CER,CHIP 1
2203-000257 C301 C-CER,CHIP 1
2203-000257 C351 C-CER,CHIP 1
2203-000257 C352 C-CER,CHIP 1
2203-000257 C422 C-CER,CHIP 1
2203-000257 C423 C-CER,CHIP 1
2203-000440 C404 C-CER,CHIP 1
2203-000440 C405 C-CER,CHIP 1
2203-000440 C406 C-CER,CHIP 1
2203-000440 C408 C-CER,CHIP 1
2203-000440 C409 C-CER,CHIP 1
2203-000440 C410 C-CER,CHIP 1
2203-000440 C411 C-CER,CHIP 1
2203-000440 C501 C-CER,CHIP 1
2203-000440 C504 C-CER,CHIP 1
2203-000440 C505 C-CER,CHIP 1
2203-000440 C506 C-CER,CHIP 1
2203-000440 C507 C-CER,CHIP 1
2203-000440 C508 C-CER,CHIP 1
2203-000440 C510 C-CER,CHIP 1
2203-000440 C512 C-CER,CHIP 1
2203-000440 C523 C-CER,CHIP 1
2203-000440 C904 C-CER,CHIP 1
2203-000783 C455 C-CER,CHIP 1
2203-000783 C458 C-CER,CHIP 1
2203-002002 C453 C-CER,CHIP 1

6-11 Samsung Electronics


OUTDOOR MAIN PBA(DB92-02866A) - (cont.)

2203-002002 C454 C-CER,CHIP 1


2203-002002 C459 C-CER,CHIP 1
2203-002002 C515 C-CER,CHIP 1
2203-002002 C516 C-CER,CHIP 1
2203-002002 C517 C-CER,CHIP 1
2203-002002 C518 C-CER,CHIP 1
2203-002002 C519 C-CER,CHIP 1
2203-002398 C524 C-CER,CHIP 1
2203-005249 C061 C-CER,CHIP 1
2203-005249 C151 C-CER,CHIP 1
2203-005249 C152 C-CER,CHIP 1
2203-005249 C153 C-CER,CHIP 1
2203-005249 C154 C-CER,CHIP 1
2203-005249 C162 C-CER,CHIP 1
2203-005249 C163 C-CER,CHIP 1
2203-005249 C220 C-CER,CHIP 1
2203-005249 C221 C-CER,CHIP 1
2203-005249 C251 C-CER,CHIP 1
2203-005249 C252 C-CER,CHIP 1
2203-005249 C253 C-CER,CHIP 1
2203-005249 C254 C-CER,CHIP 1
2203-005249 C302 C-CER,CHIP 1
2203-005249 C303 C-CER,CHIP 1
2203-005249 C304 C-CER,CHIP 1
2203-005249 C305 C-CER,CHIP 1
2203-005249 C306 C-CER,CHIP 1
2203-005249 C307 C-CER,CHIP 1
2203-005249 C401 C-CER,CHIP 1
2203-005249 C402 C-CER,CHIP 1
2203-005249 C403 C-CER,CHIP 1
2203-005249 C407 C-CER,CHIP 1
2203-005249 C420 C-CER,CHIP 1
2203-005249 C424 C-CER,CHIP 1
2203-005249 C460 C-CER,CHIP 1
2203-005249 C503 C-CER,CHIP 1
2203-005249 C509 C-CER,CHIP 1
2203-005249 C511 C-CER,CHIP 1
2203-005249 C514 C-CER,CHIP 1
2203-005249 C520 C-CER,CHIP 1
2203-005249 C521 C-CER,CHIP 1
2203-005249 C525 C-CER,CHIP 1
2203-005249 C526 C-CER,CHIP 1
2203-005249 C527 C-CER,CHIP 1
2203-005249 C701 C-CER,CHIP 1
2203-005249 C702 C-CER,CHIP 1
2203-005249 C703 C-CER,CHIP 1
2203-005249 C704 C-CER,CHIP 1
2203-005249 C903 C-CER,CHIP 1
2203-006158 C201 C-CER,CHIP 1
2203-006158 C203 C-CER,CHIP 1

6-12 Samsung Electronics


OUTDOOR MAIN PBA(DB92-02866A) - (cont.)

2203-006158 C204 C-CER,CHIP 1


2203-006158 C206 C-CER,CHIP 1
2203-006158 C207 C-CER,CHIP 1
2203-006158 C208 C-CER,CHIP 1
2203-006158 C210 C-CER,CHIP 1
2203-006158 C211 C-CER,CHIP 1
2203-006158 C212 C-CER,CHIP 1
2203-006460 C522 C-CER,CHIP 1
2203-006960 C902 C-CER,CHIP 1
2203-007456 C202 C-CER,CHIP 1
2203-007456 C205 C-CER,CHIP 1
2203-007456 C209 C-CER,CHIP 1
2203-007456 C213 C-CER,CHIP 1
2203-007456 C214 C-CER,CHIP 1
2203-007456 C226 C-CER,CHIP 1
2203-007456 C227 C-CER,CHIP 1
2203-007456 C228 C-CER,CHIP 1
2203-007456 C229 C-CER,CHIP 1
2402-001183 CE451 C-AL,SMD 1
2402-001268 CE153 C-AL,SMD 1
2402-001268 CE404 C-AL,SMD 1
2402-001268 CE420 C-AL,SMD 1
2402-001368 CE401 C-AL,SMD 1
2402-001368 CE402 C-AL,SMD 1
2402-001368 CE403 C-AL,SMD 1
2802-001165 X201 RESONATOR-CERAMIC 1
2802-001211 X501 RESONATOR-CERAMIC 1
DB41-01227A PCB MAIN PCB MAIN 1
DB91-01517A IC501 ASSY MICOM 1
0903-001843 - IC-MICROCONTROLLER 1
ASSY-LABEL
DB98-31449A ASSY-LABEL MICOM 1
MICOM
DB91-01534A IC201 ASSY MICOM 1
DB09-00596A - IC MICOM 1

6-13 Samsung Electronics


7. Wiring Diagram

7-1 Indoor Unit

DB68-04014A-4

Samsung Electronics 7-1


7-2 Outdoor Unit

7-2 Samsung Electronics


8-1 Indoor PCB

CN21 CN81 CN61 CN63 CN62

CN43

CN76

CN32

CN91

CN77
CN31

CN72 CN51

CN75
CN71

ķ CN61/CN62/CN63 - ĸ CN71 - POWER IN Ĺ CN81 - SPI ĺ CN51 - WI-FI MODULE


STEP MOTOR #1,#3 : AC220~240V #1: SPI SIGNAL #1 : WIFI UART SIGNAL1
#1: DC 12V #2 : N.C #3 : DC 12V #2 : WIFI UART SIGNAL2
#3 : WIFI RESET SIGNAL
#2~#5 :STEP MOTOR SIGNAL
#4 : GND
#5 : DC 12V
#6 : N.C
Ļ CN51 - DISPLAY ļ CN43 - TEMPERATURE SENSOR Ľ CN21 - COMMUNICATION ľ CN72 - BLDC FAN MOTOR
#1~#11,#14,#17~#20 : MICOM DOWN #1,#2 : ROOM SENSOR #1,#2 : 485 COMM SIGNAL #1 : DC 310~340V
#12, #13, #15, #16 : N.C #3,#4 : EVA MID SENSOR #2 : N.C
#3 : AGND
#5,#6 : EVA IN SENSOR
#4 : DC 15V
#5 : FAN RPM
#6 : FAN FEEDBACK
Ŀ CN32 - FJM/NASA CN75 - SMPS POWER IN CN76 - SMPS DC OUT CN77 - SMPS DC OUT
#1~#7, #11~ #14 : FJM/NASA SIGNAL#1,#3 : AC220~240V (12V/GND/5V) (19V/GND/310V)

#8 : DC 5V #2 : N.C #1 : DC 5V #1 : DC 310V~340V
#9 : GND #2 : GND #2,#3 : N.C
#10 : DC 12V #3 : DC 12V #4 : DC 19V~27V
#5 : AGND
CN31 - DOWNLOAD
DOWNLOAD

Samsung Electronics 8-1


8-2 Outdoor PCB

3
4

10

11

12

13

14

15

16

ķ CN151 - SMPS INV ĸ CN204 - DRED Ĺ CN201- DOWNLOAD-MAIN ĺ CN251 - SENSOR


#1:15V #1:DRED1 #1~#20:DOWNLAOD #1,#2:OUTSENSOR
#2 :GND #2 :DRED2 #3,#4:DISCHARGESENSOR
#3:ENABLE #3:DRED3 #5,#6:CONDSENSOR
#4:GND
#5:5V
Ļ CN501 - EEPROM ļ CN701 - EEV-A Ľ CN152 - SMPS MAIN ľ CN301 - COMMUNICATION
#1 :GND #1~#4 :EEVSIGNAL #1 :12V #1 :F1
#3 :5V #5 :12V #2 :GND #2 :F2
#4 :EEPCS #3 :5V
#5 :EEP_SO/MICOMRX
#6 :EEP_SI_MICOM_TX
#7 :EEPCLK
Ŀ CN901 - FAN CN401- REACTOR CN030 - 4WAY CN001 - POWER-N
#1:DC310~340V #1 :REACTOR1 #1,#3 :AC220~240V #1 :N
#2:N.C #2 :REACTOR2
#3:AGND
#4:DC15V
#5:FANRPM
#6:FANFEEDBACK
CN002 - POWER-L CN003 - EARTH CN150 - SMPS AC CN402 - COMP
#1 :L #1 :EARTH #1,#3 :AC220~240V #1 :W
#2 :V
#3 :U

8-2 Samsung Electronics


8-3 Wire connecting the indoor unit terminal blocks

1. Terminal press of Ring terminal shall be set facing up before connecting wire.

Is inverted Terminalhasbeencut.

2. There shall be no empty space between Ring terminal and Screw after Clamp.
If not, there exists a possibility of fire which can be caused by electric heat in the connecting part.

, : Good
Bad : Ring terminal is connected reversely
Bad : Not clamped Screw
Bad : In the gap between Ring terminal & Screw
Bad : Unused Ring Terminal

8-3 Samsung Electronics


9. Operating Instructions

9-1 Name of Each Part

9-1-1 Indoor Unit

The design and shape are subject to change according to the model.
Main parts

Room
temperature
sensor

Wi-Fi module

Air intake

Virus Doctor Lamp

Virus Doctor
Horizontal air Vertical air

Display

Temperature indicator /
Filter Reset indicator
Defrost indicator
Power consumption indicator /
Auto clean indicator
Power button/
Remote controller receiver W i-Fi indicator
Timer/Auto cleanindicator

Samsung Electronics 9-1


9-2 Wireless Remote Control-Buttons and Display

Remote controller display Power

SPi Mode
Set the SPi Set one of the 5 operating modes
(see pages 15~16 for instructions).
Turbo / Soft
Select Ultra turbo function or Soft function Quiet
Reduce noise generated from an indoor unit
ECO Run during operation.
Vertical air swing
reduces energy usage while operating
in cool/heat mode.
automatically up and down.
Temp + - Fan
h
h
Increase/Decrease the temperature by 1 ˚C.
Auto Clean such as Auto/Low/Medium/High/Turbo.
Auto clean function – Dry inside of the
Horizontal air swing
indoor unit to get rid of odor.
d'light Cool movement automatically left and right.

On Timer Set the mode on.


Set the On Timer on.
Set/Cancel
Set/Cancel the timer/ mode.
SMART Air conditioner Network.
2ndF
Switch the function of the button on the
remote controller.
Filter Reset
Reset the Filter Clean reminder
Usage
Display the amount of power consumption for few seconds on
the indoor unit display: Time set
Set the current time
To silence the beep sound when pressing the button.

9-2 Samsung Electronics


9-2 Wireless Remote Control-Buttons and Display(AR12HSSFMWKNAX)

Remote controller buttons

Vertical air swing

blade movement automatically


Power Mode
Set one of the 5 operating modes
conditioner

Temp + Fan
Increase/Decrease the Adjust the fan speed
temperature by 1 Û&.
Options Horizontal air swing
Select options during operation
Timer blades movement automatically
Select Timer option
Settings
Select settings

SET
Set/Cancel the selected option or
Directional < >
setting
Move through the Timer,
Options or Settings menu to
make a selection

ЬIncase you wish to cancel the options or settings that you havejustset, press the Options or Settings
button again,then the most recently selected item will blink and you may simply cancel it by
pressing the SET button while selected item is blinking.

9-3 Samsung Electronics


10. Troubleshooting

10-1 Items to be checked first

1. The input voltage should be rating voltage ±10% range.


The air conditioner may not operate properly if the voltage is out of this range.

2. Is the line cable linking the indoor unit and the outdoor unit linked properly?
The indoor unit and the outdoor unit shall be linked by 5 cables.
Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables.
Otherwise the air conditioner may not operate properly.

3. When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the malfunction
of the air conditioner.

NO Operation of air conditioner Explanation


The OPERATION indication LED(BLUE) blinks when a
It indicates power is on. The LED stops blinking if the oper-
1 power plug of the indoor unit is plugged in for first
ation ON/OFF button on the remote control unit is pushed.
time.
In a COOL operation mode, the compressor does not
operate at a room temperature higher than the setting In happens after a delay of 3 minutes when the compres-
temperature that the INDOOR FAN should operate. sor is reoperated. The same phenomenon occurs when
a power is on. As a phenomenon that the compressor is
2 [ In case of heat pump model ]
reoperated after a delay of 3 minutes, the indoor fan is
In a HEAT operation mode, the compressor does not adjusted automatically with reference to a temperature of
operate at a room temperature lower than the setting the air blew.
temperature that indoor fan should operate.

The speed of the indoor fan is set to LL in DRY mode.


3 Fan speed setting is not allowed in DRY mode.
Fan speed is selected automatically in AUTO mode.

Compressor stops operation intermittently in Dry Compressor operation is controlled automatically in DRY
4
mode. mode depending on the room temperature and humidity.
Timer is being activated and the unit is in ready
Timer LED(ORANGE) of the indoor unit lights up and
5 mode. The unit operates normally if the timer opera-
the air conditioner does not operate.
tion is cancelled.
The compressor stops intermittently or the fan speed
The compressor stops intermittently in a COOL
of the indoor unit decreases to prevent inside/outside
6 mode or DRY mode, and fan speed of the indoor unit
air frozen depending on the inside/outside air tem-
decreases.
perature.
[In case of heat pump model] When the unit is turned off while de-ice is activated,
7 Compressor of the outdoor unit is operating although the compressor continus operation for up to 9
it is turned off in a HEAT mode. minutes(maximum) until the deice is completed.
[In case of heat pump model] The compressor and indoor fan stop intermittently if
room temperature exceeds a setting temperature in
8 The compressor and indoor fan stop intermittenly in order to protect the compressor from overheated air
HEAT mode. in a HEAT mode.
[In case of heat pump model] The compressor operates in a reverse cycle to remove
exterior ice in a HEAT mode, and indoor fan and out-
9 Indoor fan and outdoor fan stop operation
door fan do not operate intermittently for within 20%
intermittently in a HEAT mode. of the total heater operation.

Samsung Electronics 10-1


10-2 Communication Error

10-2-1 Communication Error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E101/E102 Communication error(Indoor<->outdoor)
◎ ● ●
Outdoor display
◎ ● ● 1min. Time out Comm.
{ { ●
Abnormal Communication
{ ● ●
OLED ON ◎LED BLINKING {LED OFF

1. Checklist :
1) Is the cable between the indoor unit and outdoor unit connected correctly?
2) Isn't the power cable and communication cable cross?

2. Troubleshooting procedure

Restart after power off.

Is the communication error occurred again? NO


Terminate the service.

YES

Is the connection of power cable and NO


Correct the wrong cable.
communication cable normal?

YES

Is the power is normal? NO


Exchange the PBA of no power unit
(check the LED Lamp)

YES

Exchange the indoor unit PBA.

YES

NO
Is the communication error occurred again? Terminate the service.

YES

Exchange the outdoor unit PBA.

10-2 Samsung Electronics


10-2-2 Indoor temperature sensor Error

Indoor display
7-SEG DISPLAY DESCRIPTION
E121 Indoor room temp sensor error

1. Checklist :
1) Is the indoor units temperature sensor connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?

2. Troubleshooting procedure

Detach the assembled sensor from the PBA sensor


connector and measure the sensor resistance with
ohmmeter(tester)

Is the sensor resistance value NO


10kohm±3% at the room temperature Ass'y Sensor Replace
of 25°C Sensor resistance value : 20°C- 12.09kohm
30°C - 8.31kohm
YES 35°C - 6.94kohm
40°C- 5.83kohm
Connect the sensor to PBA connector (6piin)
Is the connection
supply power and measureofthe
power cableof #1-#2 in
voltage
and communication cable normal?
the connector

YES
Below 0.5V or Over 4.5V? Exchange the indoor PBA

NO

Micom error or connector check

YES

Exchange the indoor PBA

Samsung Electronics 10-3


10-2-3 Indoor Eva-in temperature sensor error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E122,E123 Indoor MID, Indoor IN PIPE-TH sensor error
◎ ◎ {
OLED ON ◎LED BLINKING {LED OFF

1. Checklist :
1) Is the indoor units temperature sensor connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?

2. Troubleshooting procedure

Detach the assembled sensor from the PBA sensor


connector and measure the sensor resistance with
ohmmeter(tester)

Is the sensor resistance value


NO
#3-#4 and #5-#6 10kohm±3% at the room Sensor Replace
temperature of 25ఁ Sensor resistance value : 20°C- 12.09kohm
30°C - 8.31kohm
YES 35°C - 6.94kohm
40°C- 5.83kohm
Connect the sensor to PBA connector (6piin)
Is the connection
supply power and measure of power cableof #3-#4
the voltage
and and
communication cable normal?
#5-#6 in the connector

YES
Below 0.5V or Over 4.5V? Exchange the indoor PBA

NO

Micom error or connector check

YES

Exchange the indoor PBA

10-4 Samsung Electronics


10-2-4 When the Up/Down, Left/Right, Grill louver motor does not operate (Initial Diagnosis)
(Not displayed)

1. Checklist :
1) Is the input power voltage normal?
2) Is the Up/Down louver motor properly connected with the connector? (CN61, CN62, CN63)

2. Troubleshooting procedure

Unplug the power cord and plug it after


30seconds later.

NO Check the as in the procedure.


Is the lamp blinking? No power.

YES

NO Connect the wire PBA to louver motor


Is the connected louver wire?

YES

Does operation start when swing button of the YES


Normal
remote control unit pushed?

NO

Is the voltage changeable at the pin#2~#5 of CN61, NO Exchange the PBA


CN62, CN63
(louver connector)?

YES

Up/Down louver motor is faulty.

Samsung Electronics 10-5


10-2-5 Indoor fan motor speed detecting error (BLDC fan)

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E154 Indoor fan error
{ { ◎
OLED ON ◎LED BLINKING {LED OFF

1. Checklist :
1) Is the indoor units fan motor properly connected with the connector(CN72)?
2) Is the AC voltage correct?

2. Troubleshooting procedure

Restart after power off.

NO Power off and Separate the Fan motor wire


Does the fan rotate? from CN72 on Indoor PBA

YES

Reassemble the fan wire and input the power again Is there short among YES Exchange the Fan
each pin #1~#6 motor

NO

NO Terminate the
Is the fan error appeared again? service

YES

NO Follow the check procedure of Indoor unit


Is the voltage of CN72 #1-#3 over 250Vdc power supply error check

YES

Is the voltage of CN72


NO
#3-#5 and #3-#6 with in 1Vdc~15Vdc during Exchange the Indoor PBA
the operation?

YES

PBA problem or Motor problem


Change the PBA first and check the operation

Exchange the Fan motor

10-6 Samsung Electronics


10-2-6 Outdoor temperature sensor error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E221 Outdoor temperature sensor error
Ƽ Ƽ
Outdoor display
Ƽ Ƽ Outdoor temperature sensor error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the sensor connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
4) Is the resistance value of sensor connection pull-up correct?
MODEL "A" "B"
AR09(12)HSSFAWKNEU CN251 CN251 #1-#2
2. Troubleshooting procedure AR09(12)HSSFBWKNEU CN251 CN251 #1-#2
AR12HSSFMWKNAX CN251 CN251 #1-#2

Is the sensor connector("A") connected NO


Reconnect the sensor connector.
correctly in accordance with a color?

YES

Is the sensor resistance value NO


"B" 10kohm±3% at the room temperature Sensor Replace
of 25 Sensor resistance value : - 2012.09kohm
30 - 8.31kohm
YES 35 - 6.94kohm
40 - 5.83kkohm
Connect the sensor to PBA connector
Is the
supply connection
power of power
and measure cable of
the voltage
"B"in the connector
and communication cable normal?

YES
Below 0.5Vdc or Over 4.5Vdc? Exchange the Outdoor PBA

NO

Micom error or connector check

YES

Exchange the Outdoor PBA

Samsung Electronics 10-7


10-2-7 Outdoor Coil temperature sensor error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E231 Outdoor Cond temperature sensor error
Ƽ Ƽ
Outdoor display
Ƽ Ƽ Outdoor Cond temperature sensor error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the sensor connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
4) Is the resistance value of sensor connection pull-up correct?
MODEL "A" "B"
AR09(12)HSSFAWKNEU CN251 CN251 #5-#6
AR09(12)HSSFBWKNEU CN251 CN251 #5-#6
2. Troubleshooting procedure
AR12HSSFMWKNAX CN251 CN251 #5-#6

Is the sensor connector("A") NO


connected correctly in accordance Reconnect the sensor connector.
with a color?

YES

Is the sensor resistance value NO


"B" 10kohm±3% at the room temperature Sensor Replace
of 25 Sensor resistance value : - 20
12.09kohm
30 - 8.31kohm
YES 35 - 6.94kohm
40 - 5.83kohm
Connect the sensor to PBA connector
Is theand
supply power connection of power
measure the cable
voltage of "B"in the
connector
and communication cable normal?

YES
Below 0.5Vdc or Over 4.5Vdc? Exchange the Outdoor PBA

NO

Micom error or connector check

YES

Exchange the Outdoor PBA

10-8 Samsung Electronics


10-2-8 Outdoor Discharge temperature sensor error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3 Outdoor Discharge temperature
E251
Ƽ Ƽ sensor error
Outdoor display
Ƽ Ƽ Outdoor Discharge temperature sensor error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the sensor connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
4) Is the resistance value of sensor connection pull-up correct?
MODEL "A" "B"
AR09(12)HSSFAWKNEU CN251 CN251 #3-#4
2. Troubleshooting procedure AR09(12)HSSFBWKNEU CN251 CN251 #3-#4
AR12HSSFMWKNAX CN251 CN251 #3-#4
Is the sensor connector("A") NO
connected correctly in accordance Reconnect the sensor connector.
with a color?

YES

Is the sensor resistance value NO


"B" 200kohm±3% at the room temperature Sensor Replace
of 25 Sensor resistance value : - 20242kohm
30 - 166ohm
YES 35 - 138ohm
40 - 115kohm
Connect the sensor to PBA connector
Is theand
supply power connection of power
measure the cable
voltage of "B"in the
connector
and communication cable normal?

YES
Below 0.5Vdc or Over 4.5Vdc? Exchange the Outdoor PBA

NO

Micom error or connector check

YES

Exchange the Outdoor PBA

Samsung Electronics 10-9


10-2-9 Outdoor Discharge over temperature error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E416 Outdoor Discharge over temperature error
Ƽ Ƽ
Outdoor display
Ƽ Ƽ Outdoor Discharge over temperature error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Check the discharge temperature in the outdoor unit
2) Check the compressor locking or gas leak
3) Download the EEPROM data

2. Troubleshooting procedure

Restart after power off.

after 30min ~ 1Hr

Is the discharge over


NO
temperature sensor error appeared Terminate the service
again?

YES

The condition is too poor for


air conditioner to operate .
Wait until discharge temperature is decreased
Restart after power off

Is the discharge over temperature NO


Terminate the service
sensor error appeared again?

YES

Download the EEPROM data

Is the discharge over temperature NO


Terminate the service
sensor error appeared again?

YES

Exchange the Outdoor PBA

Exchanged the Compressor

10-10 Samsung Electronics


10-2-10 Outdoor Fan motor error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E458 O u td o o r fan erro r
Ƽ Ƽ
Outdoor display
Outdoor fan error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Are the input power voltage and the power connection correct?
2) Is the motor wire connected to the outdoor PBA correctly?
3) Is there no assembly error or non-assembly in the terminal of motor wire connector?
4) Is there no obstacle at the surrounding of motor and propeller?

2. Troubleshooting procedure
MODEL "A"
AR09(12)HSSFAWKNEU CN90
Restart after power off.
AR09(12)HSSFBWKNEU CN90
AR12HSSFMWKNAX CN90

NO Power off and Separate the Fan motor wire


Does the fan rotate? from "A" on Outdoor PBA

YES

Reassemble the fan wire and input the power again Is there short among YES Exchange the Fan
each pin #1~#6 motor

NO

NO Terminate the
Is the fan error appeared again? service

YES

NO Follow the check procedure of outdoor unit


Is the voltage of "A" #1-#3 over 250Vdc power supply error check

YES

Is the voltage of "A" #3-#5 and


NO Exchange the Outdoor PBA
#3-#6 with in 1Vdc~15Vdc during
the operation?

YES

PBA problem or Motor problem


Change the PBA first and check the operation

Exchange the Fan motor

Samsung Electronics 10-11


10-2-11 Compressor starting error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E461 Comp starting error
◎ { ◎
Outdoor display
{ ◎ { Comp starting error
OLED ON ◎LED BLINKING {LED OFF

1. Checklist :
1) Is the connection of cable for the compressor?
2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL)
3) Is the interphase resistance of compressor normal?

2. Troubleshooting procedure

Restart after power off.

NO
Is the restart error occurred again? Terminate the service

YES

NO
Is the connection of compressor wire is normal? Connect the comp wire normally

YES

Download the EEPROM data

NO
Is the restart error occurred again? Terminate the service

YES

Is the compressor body and interphase NO


Exchange the Outdoor PBA
resistance insulated?

YES

Exchange the compressor

10-12 Samsung Electronics


10-2-12 Compressor wire missing error/rotation error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3 Compressor wire missing
E467
◎ { ◎ errorr/rotation error
Outdoor display
O { O Compressor wire missing error/rotation error
OLED ON ◎LED BLINKING {LED OFF

1. Checklist :
1) Is the connection of cable for the compressor?
2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL)
3) Is the interphase resistance of compressor normal?

2. Troubleshooting procedure

Restart after power off.

NO
Is the restart error occurred again? Terminate the service

YES

Is the connection of
NO
compressor wire is normal? Connect the comp wire normally
(PBA and Compressor)

YES

NO
Is the restart error occurred again? Terminate the service

YES

Is the compressor body and NO


Exchange the Outdoor PBA
interphase resistance insulated?

YES

Exchange the compressor

Samsung Electronics 10-13


10-2-13 O.C(Over Current) error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E464 IPM Over Current(O.C) Error
◎ { ◎
Outdoor display
{ { ◎ IPM Over Current(O.C) Error
OLED ON ◎LED BLINKING {LED OFF

1. Checklist :
1) Is the IPM Shunt resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?

2. Troubleshooting procedure

Restart after power off.

NO
Is the O.C error occurred? Terminate the service

YES

NO
Is the connection of compressor wire is normal? Connect the comp wire normally

YES

NO
Is the O.C error occurred again? Terminate the service

YES

Is the condition of indoor/outdoor temperature NO


Restart after returning to the normal load
normal load?

YES

Is the O.C error


Terminate the service
occurred again?

10-14 Samsung Electronics


Is the position of
NO Correct the sensor position or
temperature sensor and sensing
value normal? exchange the sensor

Is the compressor body


NO
and interphase resistance Exchange the Outdoor PBA
insulated?

YES

Exchange the compressor

Samsung Electronics 10-15


10-2-14 DC_link voltage sensor error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E469 DC_link voltage sensor error
Ƽ Ƽ
Outdoor display
Ƽ Ƽ DC_link voltage sensor error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the input voltage of outdoor terminal block is normal?
2) Is the reactor wire connected?
3) Is the DC_link capacitor("A") assembled in accordance the specification? (Outdoor PBA)
4) Is the DC_link resistor("B") value is normal? (Outdoor PBA)

2. Troubleshooting procedure
MODEL "A" "B"
AR09(12)HSSFAWKNEU CE101,CE102,CE103 R410,R411,R412
AR09(12)HSSFBWKNEU CE101,CE102,CE103 R410,R411,R412
AR12HSSFMWKNAX CE101,CE102,CE103 R410,R411,R412

Is the connected of reactor wire? NO


Connect the reactor wire
(PBA-Reactor)

YES

Restart after power off.


Start the operation (cooling mode or heating mode)

Is the DC_link
NO
voltage ("A") is normal in operation mode? Check the power input
Normal range(280Vdc~320Vdc)

YES

Is the DC_link
NO
sensing voltage("B") is normal in operation mode? Exchange the Outdoor PBA
Normal range (0.2Vdc~4.8Vdc)

YES

NO
Is the reactor insulation damaged? Exchange the Outdoor PBA

YES

Exchange the Reactor

10-16 Samsung Electronics


10-2-15 DC_link voltage sensor error

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E488 AC Input Voltage Sensor Error
Ƽ Ƽ
Outdoor display
Ƽ Ƽ AC Input Voltage Sensor Error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the input voltage of outdoor terminal block is normal?
2) Is the reactor wire connected?
3) Is the PFC resistor("A") value is normal? (Outdoor PBA)

MODEL "A" "B"


2. Troubleshooting procedure
AR09(12)HSSFAWKNEU R105,R106,R107,R108 R105
AR09(12)HSSFBWKNEU R105,R106,R107,R108 R105
AR12HSSFMWKNAX R105,R106,R107,R108 R105

Is the connected of reactor wire? NO


Connect the reactor wire
(PBA-Reactor)

YES

Restart after power off.


Start the operation (cooling mode or heating mode)

Is the DC_link sensing


voltage("B") is normal in operation mode? NO
Exchange the Outdoor PBA
Normal range (0.2Vdc~4.8Vdc)

YES

NO
Is the reactor insulation damaged? Exchange the Outdoor PBA

YES

Exchange the Reactor

Samsung Electronics 10-17


10-2-16 DC_link voltage under/over error, H/W DC-link Over voltage protection error/PFC over load

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3 E466 DC-Link voltage under/over error
Ƽ Ƽ E483 Over Voltage Protection Error
E484 P FC o ver lo ad
Outdoor display
DC-Link voltage under/over error
Ƽ PFC over load
Over Voltage Protection Erro
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the input voltage of outdoor terminal block is normal?
2) Is the input voltage is higher than 300Vac?
3) Is the reactor wire connected?
4) Is the DC_link capacitor(A") assembled in accordance the specification? (Outdoor PBA)
5) Is the DC_link resistor("B") value is normal? (Outdoor PBA)
6) Is the PFC resistor("C") value is normal? (Outdoor PBA) MODEL "A" "B"
AR09(12)HSSFAWKNEU CE101,CE102,CE103 R101,R102,R103,R104
AR09(12)HSSFBWKNEU CE101,CE102,CE103 R101,R102,R103,R104
2. Troubleshooting procedure AR12HSSFMWKNAX CE101,CE102,CE103 R101,R102,R103,R104

MODEL "A" "B"


AR09(12)HSSFAWKNEU R105,R106,R107,R108 R101,R105
AR09(12)HSSFBWKNEU R105,R106,R107,R108 R101,R105
AR12HSSFMWKNAX R105,R106,R107,R108 R101,R105

Is the connected of reactor wire? NO


Connect the reactor wire
(PBA-Reactor)

YES

Restart after power off.

Is the the input voltage is nomal? NO


Check the input power in the powercord.
Normal range(180Vac ~ 270Vac)

YES

Restart after power off.


Start the operation (cooling mode or heating mode)

Is the DC_link voltage


("A") is normal in operation mode? NO
Check the input power
Normal range(280Vdc~320Vdc)

YES

10-18 Samsung Electronics


Is the DC_link sensing
NO
voltage("D")is normal in operation mode? Exchange the Outdoor PBA
Normal range (0.2Vdc~4.0Vdc)

YES

NO
Is the reactor insulation damaged? Exchange the Outdoor PBA

YES

Exchange the Reactor

Samsung Electronics 10-19


10-2-17 I_trip error, PFC over current

Indoor display
3-LED DISPLAY 7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E462 AC Input I_Limit Trip Error
Ƽ Ƽ
Outdoor display
Ƽ AC Input I_Limit Trip Error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the PFC Shunt("A") resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?

MODEL "A"
2. Troubleshooting procedure AR09(12)HSSFAWKNEU R425,R426
AR09(12)HSSFBWKNEU R425,R426
AR12HSSFMWKNAX R425,R426

Restart after power off.

Is the condition of indoor/outdoor NO


Restart after returning to the normal load
temperature normal load?

YES Is the I_trip error


NO Terminate the
occurred again? service

YES

Is the position of
NO Correct the sensor position or
temperature sensor and the sensing
exchange the sensor
value normal?

YES

Is the connection
NO
cable for the compressor and power Correct the cable connection
terminal normal?

YES

Exchange the Outdoor PBA

10-20 Samsung Electronics


10-2-18 Current sensor error/Input current sensor error

Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
Ƽ Ƽ E462 AC Input I_Limit Trip Error
Outdoor display
Current sensor error
Ƽ Ƽ
Input current sensor error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the PFC Shunt("A") resistance value correct? Check the resistor is opened
2) Is the IPM Shunt("B") resistance value correct? Check the resistor is opened
3) Is there no short or open around "C"?

2. Troubleshooting procedure MODEL "A" "B" "C"


AR09(12)HSSFAWKNEU R426,R425 R410,R411,R412 IC451
AR09(12)HSSFBWKNEU R426,R425 R410,R411,R412 IC451
AR12HSSFMWKNAX R426,R425 R410,R411,R412 IC451
Restart after power off.

Is the PFC shunt and IPM NO


Exchange the Outdoor PBA
shunt resistance value correct?

YES

NO
Is the current sensor error appeared again? Terminate the service

YES

Exchange the Outdoor PBA

Samsung Electronics 10-21


10-2-19 Heatsink sensor error/Heatsink over heat

Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E474 Heatsink sensor error
◎ { ◎
E500 Heatsink Over Temperature Error
Outdoor display
◎ ◎ O Heatsink sensor error
◎ O { Heatsink Over Temperature Error
OLED ON ◎LED BLINKING {LED OFF

1. Checklist :
1) Are there screws assembly in PBA-heatsink?
2) Is the gap PBA-heatsink
3) Is the fan operation normal?
4) Is the cover assembly in control-box normal?

2. Troubleshooting procedure

Restart after power off.

Are there screws in PBA-heatsink? NO


Fastening the screw
(4 screws)

YES

NO Check the fan connection


Is the fan operation normal?
Change the Fan motor

YES

Exchange the Outdoor PBA

10-22 Samsung Electronics


10-2-20 Comp Vlimit error

Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
Ƽ Ƽ E465 Comp V_limit/I_limit Error
Outdoor display
Ƽ Comp V_limit/I_limit Error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the IPM Shunt("A") resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the
ature
temper
sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?

2. Troubleshooting procedure

MODEL "A"
AR09(12)HSSFAWKNEU R410,R411,R412
Restart after power off. AR09(12)HSSFBWKNEU R410,R411,R412
AR12HSSFMWKNAX R410,R411,R412

NO
Is the O.C error occurred? Terminate the service

YES

Is the connection NO
of compressor wire is Connect the comp wire normally
normal?

YES

Is the Comp Vlimit error occurred again? NO


Terminate the service

YES

Is the condition of
indoor/outdoor temperature NO
Restart after returning to the normal load
normal load?

YES

YES Is the O.C error NO Terminate the


occurred again? service

Samsung Electronics 10-23


Is the position of
NO Correct the sensor position or
temperature sensor and sensing
exchange the sensor
value normal?

YES

Is the compressor
body and interphase resistance YES
Exchange the Outdoor PBA
insulated?

NO

Exchange the compressor

10-24 Samsung Electronics


10-2-21 EEPROM error/OTP error

Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
E470 EEPROM Data Error (no data)
Ƽ Ƽ OTP errorEEPROM Data Error
E471
(Main Micom Inv Micom)
Outdoor display
EEPROM Data Error (no data)
Ƽ OTP errorEEPROM Data Error (Main MicomInv Micom)
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is there a short around micom?
2) Is there a short around "A"?
3) Did you download or insert EEPROM IC, after changing outdoor PBA?

2. Troubleshooting procedure

MODEL "A"
power off and download EEPROM data
(or. Insert the service EEPROM IC) AR09(12)HSSFAWKNEU CN251
AR09(12)HSSFBWKNEU CN251
AR12HSSFMWKNAX CN251

Restart after power off NO


Terminate the service
Is the error appeared again?

YES

Exchange the Outdoor PBA

Samsung Electronics 10-25


10-2-22 Operation condition secession error

Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
Prohibit Operation Condition Error
E440
(Heating)
◎ { ◎
Prohibit Operation Condition Error
E441
(Cooling)
Outdoor display
O ◎ { Operation condition secession
OLED ON ◎LED BLINKING {LED OFF

1. Checklist :
1) Check the temperature around the outdoor unit.

2. Troubleshooting procedure

Restart after power off

Is the operation condition secession NO


Terminate the service
error appeared again?

YES

* Heating mode * * Cooling mode *


Is the outdoor temperature over 40ఁ or Is the outdoor temperature under -7ఁ
under -30ఁ?

YES

The temperature condition is too poor to operate.


Wait until temperature is changed

10-26 Samsung Electronics


10-2-23 Gas leak error

Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
Ƽ Ƽ E554 G A S Leak erro r
Outdoor display
GAS Leak error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the position of indoor Eva_in sensor normal?
2) Check the pipe crack
3) Check the EEV valve connection("A") in Outdoor unit
4) Check the refrigerant was charged
MODEL "A"
AR09(12)HSSFAWKNEU CN701
2. Troubleshooting procedure
AR09(12)HSSFBWKNEU CN701
AR12HSSFMWKNAX CN701

Is the position of indoor eva NO


Indoor sensor take the normal position
_in sensor normal?

YES

Restart after power off

after 20minutes later

NO
Is the gas leak error appeared again? Terminate the service.

YES

Check the EEV valve operation.

NO
Is the EEV valve connection normal? Connect the EEV valve.

YES

Is the EEV valve is operation?


NO
Check the sound of EEV valve Change the EEV valve.
after power on.

YES

Samsung Electronics 10-27


NO Check the pipe crack.
Is the pressure of refrigerant normal?
Fill up the refrigerant.

YES

Exchange the Indoor PBA


Exchange the Outdoor PBA

10-28 Samsung Electronics


102-24 No power outdoor (Initial Diagnosis) (Not displayed)

1. Checklist :
1) Is input power normal?
2) Is AC power linked correctly? (L,N,E)
3) Is mis-wiring between communication wire and Power wire?
4) Is mis-wiring between Main PBA and SMPS PBA wire?
5) Is input voltage of SMPS AC in Main PBA (CN150) normal?
6) Is the voltage of SMPS DC in Main PBA (CN151,CN152) normal?

2. Troubleshooting procedure

Unplug the power cord

Is the power cable from


NO
terminal block to PBA is correct?L :CN002, N:CN001, Reconnect the power wire correctly.
EARTH:CN003

YES

NO
Check the fuse open or not? (F001) Exchange the Main PBA

YES

Restart after power off.

NO
Is the power normal? Check the power source.

YES

Is AC power is normal for SMPS? NO


Exchange the Main PBA
CN150 : 220Vac~240Vac

YES

Check SMPS wire connection

Samsung Electronics 10-29


After seperate SMPS DC
wire (3PIN RED, 3PIN BLU) from
Main PBA Connector CN151, CN152, Check NO
the DC voltage in SMPS PBA. Is the voltage is Exchange the SMPS PBA
normal in SMPS PBA?
(SMPS : CN002, CN003 Check)

YES

After connect SMPS


DC wire (3PIN RED, 3PIN BLU) with Main PBA
Connector CN151, CN152, Check the DC voltage in NO
Exchange the Main PBA
Main PBA. Is the voltage is normal in Main PBA?
(Main : CN151,CN152 Check)

YES

Exchange the Main PBA, SMPS PBA

10-30 Samsung Electronics


10-2-25 No power outdoor (Initial Diagnosis) (Not displayed)

1. Checklist :
1) Is input power normal?
2) Is AC power linked correctly? (L,N,E)
3) Is mis-wiring between communication wire and Power wire?
4) Is input voltage of SMPS DC-link capacitor("A") normal?
5) Is the voltage of SMPS DC normal? MODEL "A" "B" "C" "D"
AR09(12)HSSFAWKXEU CE101 TB-L TB-N EARTH
2. Troubleshooting procedure AR09(12)HSSFBWKXEU CE101 TB-L TB-N EARTH
AR12HSSFMWKXAX CE101 TB-L TB-N EARTH

Unplug the power cord MODEL "E" "F" "G" "H"


AR09(12)HSSFAWKXEU F001 CE101 CE106 CE108
AR09(12)HSSFBWKXEU F001 CE101 CE106 CE108
AR12HSSFMWKXAX F001 CE101 CE106 CE108

Is the power cable from terminal block to NO


Reconnect the power wire correctly.
PBA is correct?L :"B", N:"C", EARTH:"D"

YES

Check the fuse open or not? ("E") NO


Exchange the PBA

YES

Restart after power off.

NO
Is the power normal? Check the power source.

YES

Is the SMPS DC_link voltage normal? NO


Exchange the PBA
"F":270Vdc~320Vdc

YES

Is the SMPS is normal? NO


Exchange the PBA
"G" Main 5V : 4.5Vdc ~ 5.5Vdc

YES

Is the SMPS is normal? NO


"H" Main 12V : 11Vdc ~ 13Vdc Exchange the PBA

YES

Exchange the PBA

Samsung Electronics 10-31


10-2-26 AC zero cross signal error

Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
Ƽ Ƽ E472 AC zero cross signal error
Outdoor display
Ƽ AC zero cross signal error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Check the power condition at customer's house (Is there any power noise?)
2) Have been there power failure?

2. Troubleshooting procedure
MODEL "A"
AR09(12)HSSFAWKNEU X
AR09(12)HSSFBWKNEU X
AR12HSSFMWKNAX X

Restart after power off

NO
Is the AC line zero cross signal error appeared again? Terminate the service

YES

Exchange the Outdoor PBA

10-32 Samsung Electronics


10-2-27 AC zero cross signal error

Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
Ƽ Ƽ E556 Capacity miss match error
Outdoor display
Ƽ Capacity miss match error
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Check the Btu between indoor and outdoor unit
2) Check the indoor unit option and outdoor unit EEPROM data
MODEL "A"
AR09(12)HSSFAWKNEU X
2. Troubleshooting procedure AR09(12)HSSFBWKNEU X
AR12HSSFMWKNAX X

Is the rated Btu between indoor unit NO Exchange the one of them according
and outdoor unit? to the exact model spec

YES

Reset the option code again at indoor unit

NO
Is the capacity miss match error appeared again? Terminate the service

YES

Download the EEPROM data

NO
Is the capacity miss match error appeared again? Terminate the service

YES

Exchange the Outdoor PBA


Exchange the Indoor PBA

Samsung Electronics 10-33


10-2-28 When the remote control is not receiving

1. Checklist :
1) Check if the connector was normally assembled.
2) Check the battery in remote control
3) All the lights out and check again : Change electronic typed to a fluorescent light
4) Put the set in operation and check the voltage of display PBA
5) Replace the display PBA

10-34 Samsung Electronics


10-2-29 EEV or Valve Close error-Self diagnosis

Indoor display
3-LED DISPLAY
7-SEG DISPLAY DESCRIPTION
LED1 LED2 LED3
Ƽ Ƽ E422 EEV or Valve Close error-Self diagnosis
Outdoor display
EEV or Valve Close error-Self diagnosis
LED ON Ƽ LED BLINKING LED OFF

1. Checklist :
1) Is the position of indoor Eva_in sensor normal?
2) Check the pipe crack
3) Check the EEV valve connection("A") in Outdoor unit
4) Check the refrigerant was charged MODEL "A"
AR09(12)HSSFAWKXEU CN701
AR09(12)HSSFBWKXEU CN701
2. Troubleshooting procedure AR12HSSFMWKXAX CN701

NO
Is the position of indoor eva_in sensor normal? Indoor sensor take the normal position

YES

Restart after power off

after 20minutes later

NO
Is the gas leak error appeared again? Terminate the service.

YES

Check the EEV valve operation.

NO
Is the EEV valve connection normal? Connect the EEV valve.

YES

Is the EEV valve is operation? NO


Change the EEV valve.
Check the sound of EEV valve after power on.

YES

NO Check the pipe crack.


Is the pressure of refrigerant normal?
Fill up the refrigerant.

YES

Exchange the Indoor PBA


Exchange the Outdoor PBA

Samsung Electronics 10-35


10-2-30 10-3-18 Smart Install error

1. Checklist :
1) Check the leakage region.(Use leakage detection liquid or soapy water)
2) When leakage region is found from service valve and piping connection flare nut part : After the related measures to check the
refrigerant supplements and operation.
3) If the leakage region is pipe welding part : Weld leakage region after refrigerant gas release.(Brass parts should only apply)
4) If the leakage region is surface area (Heat exchanger or pipe welding region is not) : Replace parts.
5) Check the PBA Relay
- Display of indoor unit : Ensure that the operating pilot lamp has been lighted.
- Ensure that the Relay input voltage of indoor unit PBA is normally.(If the PBA is defective, replace)

2. Troubleshooting procedure

Did stop valve of NO


the low pressure valve open Open perfectly stop valve.
perfectly? (Use the 4mm hex wrench)

YES

Re-connect after 3 seconds,


after separate the power cord.
And then begin cooling operation with minimum
temperature that can establish. (use the remote control)

YES

Connect the manifold gauge to the service


Among compressor operation, does cold air NO port of low pressure side service valve and
come out from the indoor unit? then measure the refrigerant pressure.

YES YES

Does measurement
pressure include in ±10% extent NO
of reference pressure?

YES

- Discharge temperature and the indoor [Execute the troubleshooting]


temperature measurements confirm Check the refrigerant leaks.
that the difference is more than 10ఁ. Check the PCB Relay.
- Fill up perfectly refrigerant after
re-vacuum.
YES
YES

Execute the related trouble-


shooting.

End

10-36 Samsung Electronics


10-3 PCB Inspection Method

10-3-1 Pre-inspection Notices

1. Check if you pulled out the AC power plug when you eliminate the PCB or front panel.
2. Don't hold the PCB side not impose excessive force on it to eliminate the PCB.
3. Don’t pull the lead wire but hold the whole housing to connect or disconnect a connector to the PCB.
4. In case of outdoor PCB disassembly, check first the complete discharge of condenser after 1 minute power off.

10-3-2 Inspection procedure

1. Check connector connection and peeling of PCB or bronze coating pattern when you think the PCB is broken.
2. The PCB is composed of 3 parts.
. Indoor Main part : MICOM and surrounding circuit, relay, fan motor sensing and driving circuit, temperature sensing
circuit power circuit of SMPS, buzzer circuit. Communication circuit.
. Display part : LED lamp, Switch, Remote-control module.
. Outdoor Main part : MICOM and surround circuit, fan motor sensing and driving circuit, compressor driving circuit
power circuit of SMPS, PFC control circuit, 4way circuit, communication circuit,
OPTION.(EEV control circuit, temperature sensing circuit)

10-3-3 Indoor detailed inspection procedure


No procedure Inspection Method Cause

Plug out and pull the . Over current.


1) Is 1st fuse disconnected?
1 PCB out of the control . Indoor Fan motor short.
2) Is 2nd fuse disconnected?
box Check the PCB fuse. . AC part and pattern short of Indoor PBA.

Check the power voltage

Supply power 1) Is the BD71 input voltage . Power cord is fault, Fuse open, Wrong Power
If the operating lamp 200Vac ~240Vac? cable Wiring, AC part is faulty.
2 twinkles at this time ,
2) Is the voltage between both
the above 1)~3) have no . Switching Trans of Power circuit is faulty.
terminal of C111(+)-(-) 12Vdc?
relation.
3) Is the voltage between both
. Power circuit is faulty, Load short.
terminal of C118(+)-(-) 5Vdc?

1) Is the voltage over DC 270V being


imposed on terminal #1~#3 of . Fan motor of the indoor is faulty.
fanmotor connector(CN72)?
Press the ON/OFF button.
2) The fan motor of the indoor unit
3 1. Fan speed(high) . Fan motor connector(CN72) is faulty.
doesn't run.
2. Continuous Operation
3) The power voltage between
terminal #1-#3 of the . PBA is faulty.
connector(CN72) is 0V.

Samsung Electronics 10-37


㽞 New Function [ Indoor Terminal Block Safety Device ]

1. Thermal Fuse is installed in Terminal Block as below.


(Thermal Fuse is used to prevent PL caused by a defective connection of indoor and outdoor units)

Thermal Fuse

Terminal Block Internals Connection of terminal block


and Main PBA

2. Thermal Fuse is opened when internal temperature of Terminal Block goes to a certain point due to Tracking caused by
a defective connection of indoor and outdoor units.

- When Thermal Fuse is opened, Main PBA (DC12V) is turned off and the indoor unit does not operate.
(There is no problem with Main PBA in this case)
- In the above case, the change of all-in-one Terminal Block will make Main PBA operate again.

Circuit Block

3. Measurement method of fair/defective thermal fuse

Fail Defective

10-38 Samsung Electronics


11. Block Diagram

11-1 Indoor unit

CONTROLLER

IC-MCU
HEAT EXCHANGER SENSOR
· H/V BLADE CONTROL DISPLAY PART
· INDOOR FAN MOTOR CONTROL
ROOM TEMPERATURE SENSOR · OUTDOOR COMMUNICATION · DISPLAY
· TEMPERATURE CONTROL - TIMER
· HUMIDITY CONTROL - GOODSLEEP
HUMIDITY SENSOR
· TIMER - COMFORT CARE
· BUZZER CONTROL - 88 SEGMENT
INFRARED SIGNAL · WIFI MODEM COMMUNICATION
· SPI
· DISPLAY CONTROL
· SPI

REMOTE CONTROL OSCILLATION


CIRCUIT
ZERO
VOLTAGE
DETECT

POWER ON/OFF

MODE PWM
(AUTO,COOL,DRY,FAN, CONTROL
HEAT) SIGNAL

SPI SELECT
PHOTO COUPLER INDOOR FAN MOTOR
· STEPPING MOTOR
SMART SAVER SELECT CONTROL SIGNAL
· SPI CONTROL SIGNAL
TURBO OPERATION · BUZZZER CONTROL SIGNAL
OVER
VOLTAGE
QUIET OPERATION PROTECTION

TEMPERATURE
SELECT(UP/DOWN) WI-FI MODEM

FAN SPEED SELECT


(H/M/L/AUTO)
COMMUNICATION OUTDOOR UNIT
BLADE-H/V SIGNAL
MOVING SELECT

d'LIGHT COOL SELECT


BUZZER
AUTO CLEAN SELECT
· STEPPING MOTOR DRIVE
GOOD SLEEP SELECT SPI
· SPI DRIVE
· BUZZER DRIVE
ON,OFF TIMER · STEPPING MOTOR
SELECT(UP/DOWN)
- BLDAE CONTROL(H/V)
TEMP/HUMI SELECT

BEEP ON/OFF SELECT DC5V DC12V

DISPLAY ON/OFF SELECT SMPS POWER BLOCK

WPS MODE SELECT


DC5V
AP MODE SELECT
DC12V
DC15V
AC230V
AC INPUT

Samsung Electronics 11-1


11-2 Outdoor unit

11-2 Samsung Electronics


11-2-1 Pre-inspection Notices

1. Check if you pulled out the AC power plug when you eliminate the PCB or front panel
2. Don't hold the PCB side not impose excessive force on it to eliminate the PCB
3. Don’t pull the lead wire but hold the whole housing to connect or disconnect a connector to the PCB
4. In case of outdoor PCB disassembly, check first the complete discharge of condenser after 1 minute power off

11-2-2 Inspection procedure

1. Check connector connection and peeling of PCB or bronze coating pattern when you think the PCB is broken
2. The PCB is composed of 3 parts
• Indoor Main part : MICOM and surrounding circuit, relay, fan motor sensing and driving circuit, temperature sensing circuit power
circuit of SMPS, buzzer circuit. Communication circuit
• Display part : LED lamp, Switch, Remote-control module
• Outdoor Main part : MICOM and surround circuit, fan motor sensing and driving circuit, compressor driving circuit power
circuit of SMPS, PFC control circuit, 4way circuit, communication circuit, OPTION (EEV control circuit, temperature sensing circuit)

11-2-3 Indoor detailed inspection procedure


No Procedure Inspection Method Cause
. Over current
Plug out and pull the PCB
1) Is 1st fuse disconnected? . Indoor Fan motor short
1 out of the control box
2) Is 2nd fuse disconnected? . AC part and pattern short of
Check the PCB fuse
Indoor PBA
Check the power voltage
. Power cord is fault, Fuse open,
1) Is the BD71 input voltage
Wrong Power cable Wiring,
Supply power 200Vac~240Vac?
AC part is faulty
If the operating lamp twin-
2 2) Is the voltage between both ter- . Switching Trans of Power circuit
kles at this time , the above
1)~3) have no relation minal of IC02 pin #1-#2 12Vdc? is faulty

3) Is the voltage between both ter-


. Power circuit is faulty, Load short
minal of IC02 pin #2-#3 5Vdc?

1) Is the voltage over AC 180V being


imposed on terminal #3-#5 of fan . Fan motor of the indoor is faulty
motor connector (CN72)?
Press the ON/OFF button
2) The fan motor of the indoor unit . Fan motor connector(CN72) is
3 1. Fan speed(high)
doesn't run faulty
2. Continuous Operation
3) The power voltage between
terminal #3-#5 of the . PBA is faulty
connector(CN72) is 0V

Samsung Electronics 11-3


11-2-4 Outdoor detailed inspection procedure

No procedure Inspection Method Cause


. Over current
Plug out and pull the PCB out of
. AC part and pattern short of Indoor
the control box 1) Is 1st fuse disconnected?
1 PBA
Check the PCB fuse 2) Is indoor PBA faulty?
. AC part and pattern short of Outdoor
(Wait 3 minutes after power off)
PBA
1) Is the Compressor wire connected
clockwise?
2) Is the Reactor wire connected
. Wrong assembly
2 Check the Wiring normal?
. Installation(service) condition is bad
3) Is the Fan wire connected normal?
4) Is the 4way wire connected normal?
5) Is the sensor wire connected
Check the power voltage
1) Is the voltage between Terminal . Power cord is faulty, Indoor PBA
block N(1)-1 200Vac~240Vac? fault, Wrong Power cable Wiring
. L,N,E wire wrong wiring (Terminal
Block-PBA)
2) Is the PFC050(#26-#27) input . Fuse open
voltage 200Vac~240Vac? . PTC020 open
. RY021, RY022 is faulty
. Outdoor Micom(IC151) error
Supply power and operate the set . Power circuit is faulty
3 (Use Remote-control, button in 3) Is the CE151 voltage 280Vdc~320dc?
. Load short
indoor set) . PFC050 is faulty
3) Is the CE101 voltage 280Vdc~320dc?
. Reactor wire is wrong connection
. Switching Trans of Power circuit is
4) Is the voltage CE157 voltage 15Vdc? faulty
L d h t
. Switching Trans of Power circuit is
5) Is the voltage CE155 voltage 12Vdc? faulty
L d h t
. Switching Trans of Power circuit is
6) Is the voltage CE153 voltage
faulty
3.3Vdc?
. Load short
1) Normal : RED on, GRN blink, YEL off
2) Abnormal
. L,N,C wire wrong wiring
4 Check the LED lamp display - All off : check no power
. Outdoor PBA is faulty
- abnormal display : check error
mode

11-4 Samsung Electronics


12. Reference Sheet

12-1 Low Refrigerant Pressure Distribution


Note : Please measure the refrigerant pressure after the air conditioner operates on testing cooling mode during more than
10 minutes.

■ Indoor Temp. Variation : 20°C ~ 32°C


■ Outdoor Temp. Variation : -5°C ~ 45°C

12-2 Pressure & Capacity mark

■ Power/Heat

W cal/s kcal/h Btu/h HP kg.m/s Ib.m/s

1 0.23885 0.85985 3.4121 0.001341 0.10197 0.73756

4.1868 1 3.6 14.286 0.0056146 0.42693 3.088

1.163 0.27778 1 3.9683 0.0015596 0.11859 0.85778

0.29307 0.06999 0.252 1 3.9302x10-4 0.029885 0.21616

745.7 178.11 641.19 2,544.4 1 76.04 550

9.8067 2.3423 8.4322 33.462 0.013151 1 7.233

1.3558 0.32383 1.0658 4.6262 0.0018182 0.13826 1

Samsung Electronics 12-1


12-3 Q & A for Non-trouble

Classification Class Description


Q The cooling is weak.
A When it is hot outside, its cooling capacity decreases due to the increase of the ambient temperature.
When the dust filter gets blocked or warm outside air gets in, the cooling capacity will decrease. So,
make sure to clean the dust filter frequently, prevent heat loss by closing the doors and insulate the
cooling area by using curtains, blinds, shades or window tinting.

Q The cooling is good generally. But, it gets weak when it is considerably hot.
A It occurs when the outdoor unit is exposed to direct sun light and heat-up air is not ventilated well. So,
set up a sunblind over the outdoor unit and keep stuff away from the unit to increase the ventilation.
When the cooling capacity decreases during a heat wave, clean the heat exchanger of the outdoor unit
or spray some cold water to the heat exchanger to increase the cooling capability.
Cooling
Q The cooling is weak. Does it need refrigerant charging?
A It is not correct charging refrigerant regularly. Except that you have moved in several times or the
connection pipes are broken, the refrigerant does not run low. So, when refrigerant is additionally
charged, it could be costly and cause a product's failure. When the refrigerant leaks, all of it will escape
in a short time resulting in cooling failure and no water coming out of the drain hose. So, if water comes
out from the drain hose, it indicates the normal operation of the product and it does not need
refrigerant charging.
Q It fails to do cooling.
A When the air conditioner is set to ventilation or the desired temperature is set higher than the current
temperature, it fails to do cooling. In this case, select cooling or set the desired temperature lower.
Q It floods the floor.
A Place the drain hose properly. When it is not placed properly, the drain water would flow back flooding
the floor. So, straighten out the drain hose for the water to be drained well.
Q Water drips at the drain connection (service valve) of the outdoor unit.
A When a glass bottle is taken out of the refrigerator, moisture gets condensed on its surface due to the
temperature differences. The same principle applies to the air conditioner. When cold refrigerant goes
through the copper tube, moisture gets condensed on the surface of the tube and the connection
areas. To prevent the water condensation, the pipes are insulated. But, the connection areas of the
Leakage outdoor unit are not insulated for the purpose of maintenance or repair, and water gets condensed due
to the temperature differences and drips down. Generally, it evaporates right away. But, when it drips
much during muggy days, put a water pan on the floor.
Q It leaks even though a drain pump is used.
A It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump
and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer.
Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump
problems.

Q Whenever the air conditioner is turned on, it irritates my eyes and gives me a headache.
A There are no components in the air conditioner irritating the eyes and sending out chemical smells.
But, when the air conditioner is turned on, other smell sources are sucked into the air conditioner and
Smells get out of it. So find and root out the smell sources. Generally, it occurs at a interior renovated place, a
pharmacy, a gasoline handling place, a tire shop, a second-hand book shop or an electronic component
handling place, when its chemical or musty smells are sucked in and sent out, it can be misled that the
air conditioner generates them.

12-2 Samsung Electronics


Classification Class Description
Q Whenever the air conditioner is turned on, it stinks.
A When are no components in the air conditioner sending out chemical smells. But, when the air condi-
tioner is turned on, other smell sources are sucked into the air conditioner and get out of it. So, find and
root out the smell sources. Generally, when the drain hose is taken out to the washing room or there
are sources of smells such as a diaper bin, a shoe shelf or a socks bin, bad smells generate. Also, it occurs
where glass cleaners or air fresheners are used; when they are sucked in interacting with dusts and
moistures inside, bad smells generate. these kinds of organic materials noxious to human bodies. So, we
recommend against the use of them.
Q Whenever the air conditioner is turned on, it smells sour.
A When the room is papered recently, its paste smells would be sucked inside. Also, when the air condi-
tioner is installed in the study room of young boys loving sweat-generating activities such as the bas-
ketball, excessive sweats evaporate and get sucked into the air conditioner resulting in bad smells. So,
find and root out problem or refresh the room frequently.
Smells
Q Whenever the air conditioner is turned on, it smells musty.
A It is due to the improper keeping of the product after its use. When keeping the product, dry up the
inside with the operation of ventilation to prevent must. When the product is kept without drying up
the inside with ventilation, mold would grow inside resulting in must. So, open the windows and switch
on the ventilation function to get rid of the saturated smell inside.
Q Whenever the air conditioner is turned on, it sends out bad smells such as stale smells.
A It occurs generally when there are pet animals in the house. Their smells stay at the same place.
But, when the air conditioner is turned on, the air gets circulated resulting in the circulation of the
smells. So, find and root out the problem or refresh the room frequently.
Q It sends out bad smells.
A When the air filter is filthy, it could send out bad smells. So, clean the filter and ventilate the room with
the windows open while operating the ventilation function.
Q It won't start.
A There is a power failure or it is plugged out. Also, check if the power distribution panel is switched off.
Q It goes off during operation.
A When the hot air does not escape properly, it goes off during operation. it occurs when it does not ven-
tilate properly because the outdoor unit is covered, the back of the outdoor unit is blocked by a card-
board or a plywood panel, and the front of the outdoor unit is blocked by the closed window or other
obstacles. Clear the above obstacles from the outdoor unit.

Q It generally works properly. But, when it's considerably hot, it goes off during operation.

Operation A It occurs when the outdoor unit is exposed to direct sunlight and the hot air does not escape properly.
Set up a sun blind over the outdoor unit and clear the neighboring obstacles from the outdoor unit to
provide good ventilation. When it goes off frequently during a heat wave, it would prevent the turn-
off and increase the cooling capacity cleaning the outdoor unit or spraying some water to the heat
exchanger.
Q The remote controller won't operate.

A When the batteries run out or the transmitter or receiver of the remote controller is blocked by obsta-
cles, change the batteries or keep the obstacles away from the controlling area. Also, the remote con-
troller may mot work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. In
this case, take the remote controller closer to the receiver.

Samsung Electronics 12-3


Classification Class Description
Q Who installs the air conditioner? (Relocation/Re-installation)

A When relocating or re-installing the air conditioner, make sure to contact Samsung Electronics Service
Center or Authorized Service Agent and have them to do the job. (If not, it could cause personal injury
or product damage.)
The cost for the relocation/re-installation of the air conditioner is subject to the customer's expense.
There is a cost table. But, our service engineer needs to visit to total up the cost correctly.
When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service
Agent in advance to streamline the process.
Q Is it possible to install the outdoor unit outside?
A It is possible to install it at a designated place in the apartment or on the rooftop nearby.
But, it's illegal hanging an angle iron case with the outdoor unit in it outside the apartment.
Installation Also, it is illegal obstructing passers-by with the outdoor unit installed outside.
Q What can be done to install the outdoor unit facing the road because it is a commercial
building?
A The following is an excerpt from building code going into effect from JUNE 1 st 2005. "The exhaust pipe
of a cooling or ventilation facility installed in a building adjacent to the streets of commercial or residen-
tial areas shall bel installed higher than 2 m to prevent the exhaust air from blowing directly to passers-
by and the current facilities shall be corrected by MAY 31 st 2005." So, please install it higher than 2 m or
not to blow the hot exhausting air directly to passers-by.
Q What about installing a windscreen during installation not to blow hot air directly to pass-
ers-by?
A When the hot air from the front of the outdoor unit is blocked, the product's performance will be affect-
ed and it will fail to operate properly. So, keep it at least 300mm away from its surrounding walls and
give it good ventilation.

12-4 Samsung Electronics


12-4 Cleaning /Filter Change

12-4-1 Cleaning your Air Conditioner

To get the best possible use out of your air conditioner, you must clean it regularly to remove the dust that
accumulates on the air filter.

Filtro de aire

Remove the air filter from the main body. Clean the Air filter with a vacuum cleaner or
soft brush. If dust is too heavy , rinse it with
running water.

Insert the air filter back in its original Dry the Air filter in a ventilated area.
position

it once a week.

Samsung Electronics 12-5


12-5 Installation

12-5-1 Before Installation

Keep the air conditioner outlet and inlet free from its surroundings.
In case of installation, keep the symmetry and fix it to prevent vibration.
The pipe length shall meet the standard as far as possible.

12-5-2 Installation Procedure

■ Location
Install the product in an area to guarantee the best cooling effect, convenience of piping and electric work, and
inexistence of vibration or wind.

■ Wall Drilling
Drill the wall downward in a diameter of 60 to 65mm.

■ Fixing Indoor Unit & Outdoor Unit


Fix the air conditioner indoor unit securely to the wall. Secure the outdoor unit in a suitable position.

■ Pipe Spooling & Connectingt


You shall cut the pipe with a pipe cutter and grind all the burrs of the cut surface.
pipe expansion may continue until the pipe surface becomes uneven or torn apart.
Be sure to use a torque wrench to tighten pipes or flare nuts.
<Torque & Depth>
Outer Diameter (D) Torque(kgf·cm) Depth(A)
ø6.35 mm(1/4") 140~170 1.3 mm
ø9.52 mm(3/8") 250~280 1.8 mm
ø12.70 mm(1/2") 380~420 2.0 mm
ø15.88 mm(5/8") 440~480 2.2 mm
Pipe Flare
ø19.05 mm(4/4") 9900~1,210 2.2 mm

■ Leak Test
Put an inset gas like nitrogen in the outdoor unit pipe and put soap bubbles or other test liquids on the pipe surface for
the leak test.

■ Drain Hose Connecting


Install the drain hose downward to drain water naturally. Be sure to pour water into the hose to check if it drains well.

■ Electric & Earth Work


Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the
Electric Business Laws.

■ Inspection & Trial Run


Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to
finish the installation.

12-6 Samsung Electronics


12-6 Installation Diagram of Indoor Unit and Outdoor Unit

12-6-1 Air-Purge Procedure

1) Connect each assembly pipe to the appropriate valve on Outdoor unit Indoor unit
the outdoor unit and tighten the flare nut.
A Gas pipe side C

B Liquid pipe side D


2) Connect the charging hose of low pressure side of
manifold gauge to the packed valve having a
service port (3/8" Packed valve) as shown at the
figure.

3) Open the valve of the low pressure side of manifold


gauge counter-clockwise.

4) Purge the air from the system using vacuum pump for
about 30 minutes.
- After that, please recheck that pressure is stabilized.
- Close the valve of the low pressure side of manifold
gauge clockwise.
- Remove the hose of the low pressure side
of manifold gauge.

5) Set valve cork of both liquid side and gas side of packed
valve to the open position.
Vacuum Pump

6) Mount the valve stem nuts to the 2 way and


3 way valve. And mount the service port cap to
3 way valve. Valve stem

Stem cap
7) Check for gas leakage. A
- At this time, especially check for gas (gas)
leakage from the 3 way valve's stem nuts,
and from the service port cap.
B
(liquid)

Samsung Electronics 12-7


12-6-2 "Pump down" Procedure
Pump down will be carried out when an evaporator is replaced or when the unit is relocated in another area.

1) Remove the caps from the 3 way valve and the


3 way valve.

2) Turn the 3 way valve clockwise to close and


3 way Valve
connect a pressure gauge (low pressure side)
to the service valve, and open the 3 way valve
again.

2 way Valve

3) Set the unit to cool operation mode.


(Check if the compressor is operating.)

4) Turn the 3 way valve clockwise to close.

5) When the pressure gauge indicates "0" turn the


3 way valve clockwise to close.

6) Stop operation of the air conditioner.

7) Close the cap of each valve.

Relocation of the air conditioner


t3FGFSUPUIJTQSPDFEVSFXIFOUIFVOJUJTSFMPDBUFE
t$BSSZPVUUIFQVNQEPXOQSPDFEVSF SFGFSUPUIFEFUBJMTPGAQVNQEPXOh

t3FNPWFUIFQPXFSDPSE
t%JTDPOOFDUUIFBTTFNCMZDBCMFGSPNUIFJOEPPSBOEPVUEPPSVOJUT
t3FNPWFUIFGMBSFOVUDPOOFDUJOHUIFJOEPPSVOJUBOEUIFQJQF
t"UUIJTUJNF DPWFSUIFQJQFPGUIFJOEPPSVOJUBOEUIFPUIFSQJQFVTJOHBDBQPSWJOZMQMVHUPBWPJEGPSFJHONBUFSJBM
entering.
t%JTDPOOFDUUIFQJQFDPOOFDUFEUPUIFPVUEPPSVOJU    
At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign
material entering.
t.BLFTVSFZPVEPOPUCFOEUIFDPOOFDUJPOQJQFTJOUIFNJEEMFBOETUPSFUPHFUIFSXJUIUIFDBCMFT
t.PWFUIFJOEPPSBOEPVUEPPSVOJUTUPBOFXMPDBUJPO
t3FNPWFUIFNPVOUJOHQMBUFGPSUIFJOEPPSVOJUBOENPWFJUUPBOFXMPDBUJPO

12-8 Samsung Electronics


1st 2nd 3rd 4th 5th 6th 7th 8th 9th 10th 11th 12th 13th 14th
Project Capacity Sell Feature Series Color Unit Export
A R 0 9 H S S F A W K N/X E U
A R 0 9 H S S F B W K N/X E U
A R 1 2 H S S F A W K N/X E U
A R 1 2 H S S F B W K N/X E U
A R 1 2 H S S F M W K N/X A X
ITEM 1ST 2ND Item Reference 3TH 4TH Item 5TH Item 6TH
RAC A R 1 Export 0 9 12Year E INVERTER HP S
FAC A F 2 Export 1 2
13Year F INVERTER CO V
WAC A W 3 Export 1 8
14Year H
4 Export 2 4
5 Export 3 0 15Year J
16Year K

Item1 7TH 9TH DIGIT


Export The virus doctor (The India / Latin America A / PAC K besides) S Export 1st MODEL A
Export NO virus doctor (the India / Latin America A / PAC K besides) F Export 2nd B
Special instructions: Export 3rd MODEL C
About AR**FSFNAWK/FA ,the 7TH is “S”, but there is no virus doctor in these models. Export 4th MODEL D
Export 5th MODEL E
Item 1 Item 2 Item 3 8TH 9TH
Export RAC FMC FLG (Best) 1ST MODEL F
Export RAC FMC DLX (Better) 1ST MODEL D
Export RAC FMC STD (Good1) 1ST MODEL S
Export RAC FMC ENT (Good2) 1ST MODEL N

Sinkeolreo code
Division Series Project Color Name Division component Remark
(10TH,11TH)
F Best Twilight Grille WK
F Best TBD Grille TBD
D Better Twilight Grille WK
D Better TBD Grille TBD
A3050
S Good1 Twilight Grille WK Deco : Transparency
S Good1 Midnight Blue Deco UR Grille : Twilight
N Good2 Twilight Grille WK
N Good2 TBD Grille TBD Grille : Metalic Gray

Item1 Item2 12TH


Export SET /
Export IN N
Export OUT X

The integrated code


Item The existing code The sales area CIS Desription
(13TH,14TH
1 XEU Europe Europe(XEU) EU
2 XAX Mexico Mexico(XAX) AX
GSPN (GLOBAL SERVICE PARTNER NETWORK)
Area Web Site

Europe, CIS, Mideast & Africa gspn1.samsungcsportal.com

Asia gspn2.samsungcsportal.com

North & Latin America gspn3.samsungcsportal.com

China china.samsungportal.com

This Service Manual is a property of Samsung Electronics Co., Ltd.


© Samsung Electronics Co., Ltd. August. 2013.
Any unauthorized use of Manual can be punished under applicable
Code No. AC-00045K_1
International and/or domestic law.

You might also like