Code No.

LIT-1900602
Issued February 26, 2016

S300-DIN-RDR8S and S300-DIN-I32O16 High-Density Modules

Description Features
The S300-DIN-RDR8S module provides interface control for access • Wide range nominal voltage for power source – From +12 to
and security devices associated with up to eight doors. The I32O16 24 VDC
module supports 32 inputs, 16 relay outputs, and 16 open collector • Support for RS-485 bus communications at 9600 or 19200 auto
outputs. Both RDR8S and I32O16 use standard RS-485 baud rate detection
communications and can interface with the following controllers: • Easy installation – Modules can be mounted on a flat surface, DIN
• CK722 rail, or in a Johnson Controls’ approved enclosure.
• CK721-A version 3.0 and higher • Expandable modular design – RDR8S and I32O16 modules can be
connected together using RS-485
The RDR8S provides the ability to configure supervised 4-state
• Eight-door access control input/output interface – See RDR8S or
inputs and unsupervised 2-state inputs. A total of 32 inputs can be
I32O16 Sample Configuration
configured as supervised 4-state inputs (normally open or normally
• Input Point/Output Point Disassociation (RDR8S only) – Reader
closed) or 2-state inputs. Any points not used for the door can be
terminal input/output (I/O) points can be reassigned from reader-
configured as general purpose I/O points, possibly eliminating the
specific functions to general purpose I/O points
need to purchase additional I/O modules for certain installations.
The RDR8S provides power for the card reader hardware. It does not
provide power for door locking hardware.

RDR8S and I32O16 Comparison

S300-DIN-RDR8 S300-DIN-I32O16

In the RDR8S each of the 8 door interfaces consists of: In the I32O16 each of the 8 terminals consists of:
• Wiegand® Data0 and Data1 interface or RS-485 OSDP (Open • 4 supervised inputs
Supervised Device Protocol) by terminal. • 2 relay outputs
• Supervised door monitor switch input, normally open or normally • 2 open collector outputs
closed, based on wired configuration Also, the following inputs are shared by all interfaces (one per
• Supervised request to exit switch input, normally open module):
• Supervised tamper input
• Calibration resistor input
• Supervised spare input
• Supervised power fail input
• Door strike relay, SPDT (single-pole double-throw)
• Supervised panel tamper input
• Alarm shunt relay, SPDT
• Red lamp driver (open collector)
• Green lamp driver (open collector)
• +12 VDC 250 mA per reader power supply
Also, the following inputs are shared by all interfaces (one per
module):
• Calibration resistor input
• Supervised power fail input
• Supervised panel tamper input

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2016 Johnson Controls, Inc. www.johnsoncontrols.com

1 of 3
S300-DIN-RDR8S and S300-DIN-I32O16 High-Density Modules (Continued)

Description of Signals Wiegand Interface (RDR8S Only)


All interface signals are connected by using plug-in connectors. Wiegand Data0 and Data1 interfaces are enabled.

RDR8S or I32O16 Sample Configuration


The following configuration shows a eight-door configuration with the
Settable Switches
RDR8S interfacing with a CK721-A controller. The RDR8S and I32O16 have the following settable switches: end-of-
line (EOL) and address switches.
To power supply
Exit Sensor
End-of-Line Switches
Door Monitor
When the RDR8S or I32O16 is used at the end of the RS-485 network,
To DOOR 2, it must be set as a network terminating device.
Alarm DOOR 3,
RDR8S etc. (up to 8 The EOL switch is OFF (down) by factory default.
DOOR 1 doors)
The RDR8S or I32O16 module is set as a network terminating device
Reader when the EOL switch is turned on (up).
Strike The following figure shows the location of the EOL switch.
RS-485

CK721-A EOL switch

The following configuration shows a sample I32O16 application.

To power supply Address Switches


Motion Sensor (Input)

Buzzer (Output)
The 5-position switch is used to determine RDR8S or I32O16 module
address.
The address switches are OFF (down) by factory default, denoting bus
To/from
I32O16 other inputs
address 0 (zero).
and outputs.
Note: Ensure that the address of the module does not conflict with
the address of any other device on the S300 bus.
The following figure shows the location of the adjustable 5-position
address switch. The address switch is used to set the S300 bus
RS-485

address.

Address switch
CK721-A (5-position)

Reader and I/O Modes


In the RDR8S, the reader and I/O modes are enabled.
1 2 4 8 16
LEDs
The RDR8S module has 4 LEDs:
• Power (POWER): On during normal operation.
Battery Low/Power Fail
• Status (STATUS): Blinks every second when module is The RDR8S has an internally derived, 2-state input that can be used
operational. to detect battery low or power fail state.
• Transmit (XMIT): Blinks when a character is transmitted on the To use this feature, the Input Terminal 1 - Spare Input 6 (CK721-A)
S300 bus. or Power Fail - General Purpose Input (CK722) must be wired to a
• Receive (RCV): Blinks when a character is received from the S300 power fail monitoring circuit.
bus. The internally derived input is in alarm only if the power fail point is also
in alarm and power voltage has decreased more than 10% from either
Input Point Calibration 12 V or 24 V (the system detects 12 versus 24 nominal voltage
Termination resistance ranges from 150 ohms to 2000 ohms automatically).
(recommended: 1200 ohms, 1%). To calibrate individual inputs, use
Note: For use only with 12 VDC or 24 VDC battery-backed power
a command launched from the host.
supply.

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2016 Johnson Controls, Inc. www.johnsoncontrols.com

2 of 3
S300-DIN-RDR8S and S300-DIN-I32O16 High-Density Modules (Continued)

Technical Specifications
Description Specification
Input Power Nominal voltage +12 to +24 VDC
Min. +10.8, max. +30 VDC
48 W
Reader Interface • 2-wire Wiegand (up to 256 bits)
• 12 VDC, 250 mA (typical)
• Red indicator
• Green indicator
General Purpose Inputs Resistive load
Relay Outputs 1 A max. 0-24 VDC, 25 VA max.
Red LED/Green LED 100 mA max. 0-12 VDC.
Outputs See “Important” below.
Communications 2 or 3-wire RS-485
Mounting Specifications DIN rail or flat surface
Dimensions 5.15 H x 10.58 W x 2.5 D inches
13.07 cm x 26.88 cm x 6.36 cm)
Weight 2.75 lb (1.2 kg)
Ambient Temperature 32º to 122ºF (0º to 50ºC)
Humidity 10 to 85% non-condensing
Ventilation Cabinets require free movement of air over all exposed surfaces
Compliance United States:
UL Listed under UL 1076 for Proprietary Burglar Alarm Units and Systems, and under UL 294 for Access Control Systems Units;
FCC compliant to the limits for a Class B digital device, pursuant to Part 15 of the FCC rules
Canada:
cUL under ULC/ORD-C1076 Proprietary Burglar Alarm Units and System;
Class B digital apparatus, complies with Canadian ICES-003
Europe:
CE Mark – Johnson Controls, Inc., declares that this product is in compliance with the EMC Directive
Australia and New Zealand:
RCM Mark, Australia/NZ Emissions Compliant

IMPORTANT: The Red LED/Green LED open collector outputs can be damaged with the use of AC potentials as low as 1 VAC. The LED
outputs can only be connected to DC loads up to 12 VDC.

Ordering Information Related Documentation


Part Number Description Document Title Document Number
S300-DIN-RDR8S 8-door interface, supervised inputs, outputs. S300-DIN-RDR8S / I32O16 Hardware Installation Part No. 24-10489-19
S300-DIN-I32O16 32 input/16 output interface, supervised inputs, Manual
outputs. CK721-A Version 3.2 Installation and Operation Part No. 24-10349-59
Manual
CK721-A Version 3.2 Release Notes Part No. 24-10025-83
CK721-A Version 3.2 Factory Field Upgrade Part No. 24-10025-91
Manual
CK722 Network Controller Hardware Installation Part No. 24-10239-6
Manual
Panel Assembly Mounted in 20 x 30 Enclosure Part No. 24-10638-4
Panel Assembly Mounted in 20 x 42 Enclosure Part No. 24-10638-12

The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office.
Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. © 2016 Johnson Controls, Inc. www.johnsoncontrols.com

3 of 3