Nito or SL2000: Flow Applied, 2mm Thick Epoxy Resin Based Oor Topping
Nito or SL2000: Flow Applied, 2mm Thick Epoxy Resin Based Oor Topping
Nito or SL2000: Flow Applied, 2mm Thick Epoxy Resin Based Oor Topping
Uses
Pot Life @ 250C @350C
The designated floor areas shall be surfaced with Nitoflor Design criteria
SL2000, a 2 mm thick flow-applied epoxy resin floor topping.
The topping shall achieve a minimum compressive strength Nitoflor SL2000 is designed for application at a nominal
of 50 N/mm2 and a flexural strength of 26 N/mm2 at 7 days thickness of 2mm.
when tested to BS6319. At 250C, it shall be capable of accept-
ing foot traffic at 24 hours and vehicular traffic at 48 hours. Substrates should be dry and not suffer, or be likely to
Properties suffer, from rising damp. If necessary, suitable damp-proof
The values given below are average figures achieved in membranes should be installed during construction to prevent
laboratory tests. Actual values obtained on site may show this. Substrates should not have a relative humidity greater
minor variations from those quoted. than 75% at the time of installation.
Method Statement. Fosroc works with a network of such to the next stage. Do not proceed whilst the primer is ‘tacky’
applicators who have been trained in the correct installation as this will lead to unsightly marks on the finished surface.
procedures. The following steps are involved in the applica-
tion which would normally take place over a 2 to 3 day period Porous substrates may require a second primer coat - when
depending on the areas involved. the first coat is directly absorbed into the substrate - but
minimum overcoating times must still be observed (see table
Surface Preparation below).
It is essential that Nitoflor SL2000 is applied to sound, clean The minimum overcoating times will vary slightly according
and dry surfaces in order that maximum bond strength is to the porosity of the substrate. However, they should
achieved between the substrate and the flooring system. All be in accordance with the following ambient application
dust and debris should be removed prior to application of the temperatures.
product or its primer.
200C : 8-12 hours
New concrete floors
300C : 6-8 hours
New concrete, or cementitious substrates, should be at least
400C : 4-6 hours
28 days old and have a moisture content not exceeding 5%.
Laitance deposits on new concrete are best removed by light Mixing
grit blasting, mechanical scrabbling or grinding.
Nitoflor SL flooring is supplied in four pre-weighed packs (base,
Old concrete floors hardener, aggregate and colour pack) which are ready for
immediate on-site mixing. Part mixing of these components
Existing concrete floors which require refurbishment must
is not acceptable and will affect both performance and
be prepared to ensure a strong adhesive bond between the
appearance of the finished floor.
flooring system and the existing floor. Mechanical cleaning
methods are strongly recommended particularly where heavy Mixing should be carried out using either a forced action mixer;
contamination by oil and grease has occurred or existing or a heavy duty, slow-speed drill fitted with mixing paddle. All
coatings are present. To ensure adhesion, all contamination such equipment should be of a type and capacity approved
should be removed. by Fosroc. The components should be mixed in a suitably
sized mixing vessel.
Alternatively, blasting techniques can be used to provide the
required substrate The colour pack should be added to the base container and
mixed for 15-30 seconds, until homogeneous. Then add the
Steel surfaces
hardener and mix for further 30 seconds, until an even colour
Steel surfaces should be degreased and grit blasted to and texture is obtained.
SA2½ immediately prior to application. The prepared surface Thereafter, the contents of the graded aggregate pack should
should than be treated with one coat of Nitoprime 28. be slowly added and mixing carried out for a further 3 minutes
Priming until a completely homogenous material is obtained.
‘back and forth’ technique along the same path. An overlap consult the local Fosroc office.
of 50% with adjacent paths is recommended. Nitoflor SL2000 should not be installed at temperatures
Further light rolling may be required to remove surface below 100C or above 450C. If in doubt, or for application
imperfections, or for subsequent release of trapped air, but outside these temperature limits, please consult your
should be prior to the setting of the product. nearest Fosroc office.
Estimating
Joint sealant & joint geometry should be compatible with
the floor type used, intended exposure conditions and likely Supply
movement characteristics of the substrate - consult the local
Nitoflor SL2000 : 15 litre pack
Fosroc office for more details.
(incl. colour pack)
Cleaning
Nitoprime 25 : 1 and 4 litre packs
Nitoprime 25, and Nitoflor SL2000 should be removed from Nitoflor Sol : 5 and 20 litre tins
tools and equipment with Fosroc Nitoflor Sol immediately after
use. Hardened material can only be removed mechanically. Coverage
Limitations Store in dry conditions between 50C and 300C, away from
sources of heat and naked flames, in the original, unopened
Nitoflor SL2000 should not be applied on to surfaces
packs. If stored at high temperatures the shelf life will be
known to, or likely to suffer from, rising dampness, potential
reduced.
osmosis problems or have a relative humidity greater than
75% as measured in accordance with BS 8203 Appendix Precautions
A, or by protimeter. Health and safety
In areas where significant thermal shock is likely to occur,
please consult the local Fosroc office. Nitoflor SL2000, Nitoprime 25, Nitoprime 28 and Nitoflor Sol
should not come in contact with the skin and eyes, or be
Nitoflor SL2000 should not be applied to asphalt, weak or
swallowed.
friable concrete, unmodified sand/cement screeds, PVC
tiles or sheet or substrates known to move substantially
Ensure adequate ventilation and avoid inhalation of vapours.
e.g. steel walkways. For information on other substrates,
Some people are sensitive to resins, hardeners and solvents.
Wear suitable protective clothing, gloves and eye protection. Additional information
Fosroc manufactures a wide range of complementary products
In case of contact with skin, rinse with plenty of clean water,
which include :
then cleans with soap and water. Do not use solvent. In case
of contact with eyes, rinse immediately with plenty of clean waterproofing membranes & waterstops
water and seek medical advice. If swallowed seek medical joint sealants & filler boards
attention immediately - do not induce vomitting.
cementitious & epoxy grouts
Fire specialised flooring materials
Nitoprime 25 and Nitoflor Sol are flammable. Keep away from Fosroc additionally offers a comprehensive package of prod-
sources of ignition. No smoking. In the event of fire extinguish ucts specifically designed for the repair and refurbishment
of damaged concrete. Fosroc’s ‘Systematic Approach’ to
with CO2 or foam. Do not use a water jet.
concrete repair features the following :
Nitoflor SL2000 is non-flammable.
hand-placed repair mortars
Flash points spray grade repair mortars
Important note :
Fosroc products are guaranteed against defective materials and manufacture and are sold
subject to its standard terms and conditions of sale, copies of which may be obtained on
request. Whilst Fosroc endeavours to ensure that any advice, recommendation specification
or information it may give is accurate and correct, it cannot, because it has no direct or
continuous control over where or how its products are applied, accept any liability either
Fosroc Chemicals directly or indirectly arising from the use of its products whether or not in accordance with
any advice, specification, recommendation or information given by it.
(India) Pvt. Ltd.
Head Office telephone fax e-mail
Embassy Point, No. 150,
2nd Floor, Infantry Road, +91 80-42521900 +91 80-22281510 [email protected]
Bangalore 560 001,
Karnataka
Regional Offices
www.fosroc.com
page 4 of 4 INDIA/2020/0513/A