Total NH NH NH NH 53306.524011 Q (KW) - 145.23864592945: Energy Balance For Converter

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

ENERGY BALANCE FOR DRYING TOWER

Inlet Outlet
Stream
Stream 3 Stream 29 Stream 4 Stream 18
Molar Molar Enthalpy Molar Molar
Compon Enthalpy Enthalpy Enthalpy
flowrate flowrate (kJ/kmol flowrate flowrate
ents (kJ/kmol) (kJ/kmol) (kJ/kmol)
(kmol/hr) (kmol/hr) ) (kmol/hr) (kmol/hr)
O2 243.464 737.6923 - - 58.023 1016.1457 - -
N2 900.8168 645.9589 - - 218.277 890.0986 - -
H2O 60.866 415.0375 - - - - - -
H2SO4 - - 561.162 76.0203 - - 567.41 93.9471
Total nH 786753.82 nH 42659.7 nH 253247.874 nH 53306.524011
Q (kW) -145.23864592945

ENERGY BALANCE FOR CONVERTER


Inlet
Stream
Stream 18 Stream 8 Stream 10 Stream 12
Molar Enthalpy Molar Molar Enthalpy Molar
Compon Enthalpy
flowrate (kJ/kmol flowrate flowrate (kJ/kmol flowrate
ents (kJ/kmol)
(kmol/hr) ) (kmol/hr) (kmol/hr) ) (kmol/hr)
O2 - - 130.2 1674.6925 86.23 940.3152 75.3
N2 - - 936.78 1467.0926 936.78 824.0577 936.78
SO2 - - 118.9 3446.9249 30.93 1876.21 9.04
SO3 - - - - - - 109.88
H2SO4 567.41 93.9471 - - - - -

Total nH 53306.52 nH 2002227.3399 nH 911075 nH


Q (kW) 1445.07846032861

Outlet
Stream
Stream 9 Stream 11 Stream 13
Molar Enthalpy Molar Molar Enthalpy
Compon Enthalpy
flowrate (kJ/kmol flowrate flowrate (kJ/kmol
ents (kJ/kmol)
(kmol/hr) ) (kmol/hr) (kmol/hr) )
O2 86.23 2148.266 75.3 1860.5647 72.75 1758.611
N2 936.78 1881.67 936.78 1629.845 936.78 1540.578
SO2 30.93 4292.935 9.04 3718.1533 3.93 3514.517
SO3 88 5372.712 109.88 4651.6784 115 4396.367
Total nH 2553535 nH 2211645.24943 nH 2090516
Q (kW) 1904.359960625
R

Stream 12 Stream 14
Molar
Enthalpy Enthalpy
flowrate
(kJ/kmol) (kJ/kmol)
(kmol/hr)
932.287 72.75 948.3448 5066.69
817.0268 936.78 831.0889
1860.2089 3.93 1892.2128
2328.7088 115 2368.9299
- - -

1108270.3882 nH 1127402.8787

3401.4

Qtotal (kW) 459.2815