Tech Note: Pump Side Modules PVPV and PVPVM For Pumps With Variable Displacement
Tech Note: Pump Side Modules PVPV and PVPVM For Pumps With Variable Displacement
Tech Note: Pump Side Modules PVPV and PVPVM For Pumps With Variable Displacement
Pump side
modules PVPV and
PVPVM for pumps
with variable
displacement
Tech Note
BACK
Pump side modules PVPV and PVPVM for pumps with variable
displacement
Application
CONTENS Application..........................................................................................................................................................................2
Hydraulic system..............................................................................................................................................................4
Dimensions .........................................................................................................................................................................6
Specification.......................................................................................................................................................................7
APPLICATION Sauer-Danfoss is now able to supply pump side modules type PVPV and PVPVM for
systems with variable pumps. The new modules offer the following advantages:
© 2001 Sauer-Danfoss
Sauer-Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Sauer -Danfoss reserves the right
to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without subsequent
changes being necessary in specifications already agreed. All trademarks in this material are properties of the respective companies. Sauer-Danfoss
and the Sauer-Danfoss logotype are trademarks of the Sauer-Danfoss Group. All rights reserved.
2 DKMH.PN.500.DD.02 520L0222
BACK
Pump side modules PVPV and PVPVM for pumps with variable
displacement
Versions and code numbers
Code number
Symbol Description
P og T = G1 [1 5/16 UN]
PVPV
Closed center pump side module for
pumps with variable displacement
PVPV
Closed center pump side module for
pumps with variable displacement
PVPVM
Closed center pump side module for
pumps with variable displacement
PVPVM
Closed center pump side module for
pumps with variable displacement
DKMH.PN.500.DD.02 520L0222 3
BACK
Pump side modules PVPV and PVPVM for pumps with variable
displacement
Hydraulic system
PVPV When ordering PVPV fitted with PVLP 63, please state the sales- and code No. in space 0
in the order form. Also, always state the PVLP 63 opening pressure in space 0.
(See example)
Example:
0 157B 5941 157B 2100
PVPVM To order PVG 32 fitted with PVPVM, use standard order form DKMH.PZ.570.D8.02 520L0515
and for the SAE versions DKMH.PZ.570.B7.22 520L0354.
When ordering PVPVM fitted with PVLP 63, please state the sales- and code No. in space
b in the order form.
Also, always state the PVLP 63 opening pressure in space 0. (see example page 7)
4 DKMH.PN.500.DD.02 520L0222
BACK
Pump side modules PVPV and PVPVM for pumps with variable
displacement
Flow characteristics
FLOW CHARACTERISTICS Flow from PVB (without pressure compensator) left and rigth of PVPVM respectively.
FOR PVPV/PVPVM
(For flow characteristics on PVPV, see catalogue DKMH.PK.570.C2.02 520L0344)
Note that under certain circumstances systems with large pump flows may occasionally
generate pressure peaks.
For advice on systems of this nature, please contact the Sauer-Danfoss Sales Organisation
Set pressure
difference between
pump pressure and
LS signal = 10 bar
[145 psi]
Set pressure
difference between
pump pressure and
LS signal = 15 bar
[218 psi]
The oil flow depends on the pressure difference between pump pressure and LS-signal.
Normally, the pressure difference can be set on the LS-pump control.
DKMH.PN.500.DD.02 520L0222 5
BACK
Pump side modules PVPV and PVPVM for pumps with variable
displacement
Dimensions
DIMENSIONS
MA og LS: G 1/4
For dimensions on PVPV and other PVPVM measures, see technical information DKMH.PK.570.C2.02 520L0344
Spare parts for PVG 32, see DKMH.PS.570.A5.02 520 L0211
STAY BOLT SET, PVAS FOR In PVG 32 valve groups fitted with PVPV use standard PVAS, 157B8001 - 8010
PVPVM For pump pressures over 320 bar [4641 psi], use stay bolt set 157B8041 - 8050
6 DKMH.PN.500.DD.02 520L0222
BACK
Pump side modules PVPV and PVPVM for pumps with variable
displacement
Specification Sheet PVG 32
PVG 32
Specification Sheet
bar
p = 100 psi
157B
b bar bar b
157B LSA LSB 157B
psi psi
b bar bar b
157B LSA LSB 157B
psi psi
b bar bar b
157B LSA LSB 157B
psi psi
b bar bar b
157B LSA LSB 157B
psi psi
b bar bar b
157B LSA LSB 157B
psi psi
12 157B 8024
Filled in by Date
PHYD-PVG32-3
DKMH.PN.500.DD.02 520L0222 7
BACK
Gear pumps and motors We offer our customers optimum solutions for their needs and
develop new products and systems in close cooperation and
Bent axis motors
partnership with them.
Radial piston motors
Sauer-Danfoss specializes in integrating a full range of system
Orbital motors components to provide vehicle designers with the most advanced
total system design.
Transit mixer drives
Planetary compact gears Sauer-Danfoss provides comprehensive worldwide service for its
products through an extensive network of Authorized Service
Proportional valves Centers strategically located in all parts of the world.
Cartridge valves
Hydrostatic transaxles
Integrated systems