Simscape Guide PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 426
At a glance
Powered by AI
The key takeaways are about modeling physical systems using Simscape and the Physical Network approach.

The Physical Network approach models physical systems as networks of components that exchange energy through connection ports. This mimics real physical connections and does not require specifying flow directions.

The basic principles include using nondirectional connection ports to represent energy flows, with the number of ports depending on the component's idealization level. It also discusses variable types and building the mathematical model.

Simscape™

User's Guide

R2015b
How to Contact MathWorks

Latest news: www.mathworks.com

Sales and services: www.mathworks.com/sales_and_services

User community: www.mathworks.com/matlabcentral

Technical support: www.mathworks.com/support/contact_us

Phone: 508-647-7000

The MathWorks, Inc.


3 Apple Hill Drive
Natick, MA 01760-2098
Simscape™ User's Guide
© COPYRIGHT 2007–2015 by The MathWorks, Inc.
The software described in this document is furnished under a license agreement. The software may be used
or copied only under the terms of the license agreement. No part of this manual may be photocopied or
reproduced in any form without prior written consent from The MathWorks, Inc.
FEDERAL ACQUISITION: This provision applies to all acquisitions of the Program and Documentation
by, for, or through the federal government of the United States. By accepting delivery of the Program
or Documentation, the government hereby agrees that this software or documentation qualifies as
commercial computer software or commercial computer software documentation as such terms are used
or defined in FAR 12.212, DFARS Part 227.72, and DFARS 252.227-7014. Accordingly, the terms and
conditions of this Agreement and only those rights specified in this Agreement, shall pertain to and
govern the use, modification, reproduction, release, performance, display, and disclosure of the Program
and Documentation by the federal government (or other entity acquiring for or through the federal
government) and shall supersede any conflicting contractual terms or conditions. If this License fails
to meet the government's needs or is inconsistent in any respect with federal procurement law, the
government agrees to return the Program and Documentation, unused, to The MathWorks, Inc.
Trademarks
MATLAB and Simulink are registered trademarks of The MathWorks, Inc. See
www.mathworks.com/trademarks for a list of additional trademarks. Other product or brand
names may be trademarks or registered trademarks of their respective holders.
Patents
MathWorks products are protected by one or more U.S. patents. Please see
www.mathworks.com/patents for more information.
Revision History
March 2007 Online only New for Version 1.0 (Release 2007a)
September 2007 Online only Revised for Version 2.0 (Release 2007b)
March 2008 Online only Revised for Version 2.1 (Release 2008a)
October 2008 Online only Revised for Version 3.0 (Release 2008b)
March 2009 Online only Revised for Version 3.1 (Release 2009a)
September 2009 Online only Revised for Version 3.2 (Release 2009b)
March 2010 Online only Revised for Version 3.3 (Release 2010a)
September 2010 Online only Revised for Version 3.4 (Release 2010b)
April 2011 Online only Revised for Version 3.5 (Release 2011a)
September 2011 Online only Revised for Version 3.6 (Release 2011b)
March 2012 Online only Revised for Version 3.7 (Release 2012a)
September 2012 Online only Revised for Version 3.8 (Release 2012b)
March 2013 Online only Revised for Version 3.9 (Release 2013a)
September 2013 Online only Revised for Version 3.10 (Release 2013b)
March 2014 Online only Revised for Version 3.11 (Release 2014a)
October 2014 Online only Revised for Version 3.12 (Release 2014b)
March 2015 Online only Revised for Version 3.13 (Release 2015a)
September 2015 Online only Revised for Version 3.14 (Release 2015b)
Contents

Model Construction
1
Basic Principles of Modeling Physical Networks . . . . . . . . . 1-2
Overview of the Physical Network Approach to Modeling
Physical Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Variable Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Building the Mathematical Model . . . . . . . . . . . . . . . . . . . . . 1-5
Direction of Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6
Connector Ports and Connection Lines . . . . . . . . . . . . . . . . . 1-8
Connecting Simscape Diagrams to Simulink Sources and
Scopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9

Simscape Block Libraries . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11


Library Structure Overview . . . . . . . . . . . . . . . . . . . . . . . . 1-11
Using the Simulink Library Browser to Access the Block
Libraries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Using the Command Prompt to Access the Block Libraries . 1-13

Essential Physical Modeling Techniques . . . . . . . . . . . . . . . 1-15


Building Your Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
Using the Conserving Ports . . . . . . . . . . . . . . . . . . . . . . . . . 1-16
Using the Physical Signal Ports . . . . . . . . . . . . . . . . . . . . . 1-16

Creating and Simulating a Simple Model . . . . . . . . . . . . . . . 1-18


Building a Simscape Diagram . . . . . . . . . . . . . . . . . . . . . . . 1-18
Modifying Initial Settings . . . . . . . . . . . . . . . . . . . . . . . . . . 1-26
Running the Simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-28
Adjusting the Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 1-30

Modeling Best Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-36


Grounding Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-36
Avoiding Numerical Simulation Issues . . . . . . . . . . . . . . . . 1-40

Domain-Specific Line Styles . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43

v
Modeling Pneumatic Systems . . . . . . . . . . . . . . . . . . . . . . . . 1-46
Intended Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-46
Assumptions and Limitations . . . . . . . . . . . . . . . . . . . . . . . 1-46
Fundamental Equations . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-47
Network Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-48
Connection Constraints . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-48
References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-49

Thermal Liquid Models


2
Modeling Thermal Liquid Systems . . . . . . . . . . . . . . . . . . . . . 2-2
When to Use Thermal Liquid Blocks . . . . . . . . . . . . . . . . . . . 2-2
Modeling Workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Establish Model Requirements . . . . . . . . . . . . . . . . . . . . . . . 2-3
Model Physical Components . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Prepare Model for Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Run Simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

Thermal Liquid Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6


Why Use Thermal Liquid Blocks? . . . . . . . . . . . . . . . . . . . . . 2-6
Representing Thermal Liquid Components . . . . . . . . . . . . . . 2-6
Specifying Thermal Liquid Medium . . . . . . . . . . . . . . . . . . . 2-8
Modeling Multidomain Systems . . . . . . . . . . . . . . . . . . . . . . 2-8

Thermal Liquid Modeling Framework . . . . . . . . . . . . . . . . . 2-10


How Blocks Represent Components . . . . . . . . . . . . . . . . . . 2-10
How Ports Represent Interfaces . . . . . . . . . . . . . . . . . . . . . 2-11
Full Flux Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12

Heat Transfer in Insulated Oil Pipeline . . . . . . . . . . . . . . . . 2-14


Oil Pipelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Modeling Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
Simscape Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17
Run Simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
Run Optimization Script . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-25

vi Contents
Two-Phase Fluid Models
3
Manually Generate Fluid Property Tables . . . . . . . . . . . . . . . 3-2
Fluid Property Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Steps for Generating Property Tables . . . . . . . . . . . . . . . . . . 3-3
Before Generating Property Tables . . . . . . . . . . . . . . . . . . . . 3-3
Create Fluid Property Functions . . . . . . . . . . . . . . . . . . . . . . 3-3
Set Property Table Criteria . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Create Pressure-Normalized Internal Energy Grids . . . . . . . 3-5
Map Grids Onto Pressure-Specific Internal Energy Space . . . 3-5
Obtain Fluid Properties at Grid Points . . . . . . . . . . . . . . . . . 3-6
Visualize Grids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7

Model Simulation
4
How Simscape Models Represent Physical Systems . . . . . . . 4-2
Representations of Physical Systems . . . . . . . . . . . . . . . . . . . 4-2
Differential, Differential-Algebraic, and Algebraic Systems . . 4-2
Stiffness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Events and Zero Crossings . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Working with Simscape Representation . . . . . . . . . . . . . . . . 4-3

How Simscape Simulation Works . . . . . . . . . . . . . . . . . . . . . . 4-5


Simscape Simulation Phases . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Model Validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Network Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Equation Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Initial Conditions Computation . . . . . . . . . . . . . . . . . . . . . . . 4-8
Transient Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
Transient Solve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10

Setting Up Solvers for Physical Models . . . . . . . . . . . . . . . . 4-11


About Simulink and Simscape Solvers . . . . . . . . . . . . . . . . 4-11
Choosing Simulink and Simscape Solvers . . . . . . . . . . . . . . 4-11
Harmonizing Simulink and Simscape Solvers . . . . . . . . . . . 4-13

vii
Important Concepts and Choices in Physical Simulation . . 4-17
Variable-Step and Fixed-Step Solvers . . . . . . . . . . . . . . . . . 4-17
Explicit and Implicit Solvers . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Full and Sparse Linear Algebra . . . . . . . . . . . . . . . . . . . . . 4-18
Event Detection and Location . . . . . . . . . . . . . . . . . . . . . . . 4-18
Unbounded, Bounded, and Fixed-Cost Simulation . . . . . . . . 4-19
Global and Local Solvers . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19

Making Optimal Solver Choices for Physical Simulation . . 4-21


Simulating with Variable Time Step . . . . . . . . . . . . . . . . . . 4-21
Simulating with Fixed Time Step — Local and Global Fixed-
Step Solvers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-21
Simulating with Fixed Cost . . . . . . . . . . . . . . . . . . . . . . . . . 4-22
Troubleshooting and Improving Solver Performance . . . . . . 4-23
Multiple Local Solvers Example with a Mixed Stiff-Nonstiff
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24

Troubleshooting Simulation Errors . . . . . . . . . . . . . . . . . . . 4-26


Troubleshooting Tips and Techniques . . . . . . . . . . . . . . . . . 4-26
System Configuration Errors . . . . . . . . . . . . . . . . . . . . . . . . 4-27
Numerical Simulation Issues . . . . . . . . . . . . . . . . . . . . . . . 4-29
Initial Conditions Solve Failure . . . . . . . . . . . . . . . . . . . . . 4-30
Transient Simulation Issues . . . . . . . . . . . . . . . . . . . . . . . . 4-30

Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32
Sample Time and Solver Restrictions . . . . . . . . . . . . . . . . . 4-32
Algebraic Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-32
Restricted Simulink Tools . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
Unsupported Simulink Tools and Features . . . . . . . . . . . . . 4-35
Simulink Tools Not Compatible with Simscape Blocks . . . . . 4-35
Code Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-35

References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-37

Variable Initialization and State Viewer


5
About Variable Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Initializing Block Variables for Model Simulation . . . . . . . . . 5-2
Variable Initialization Priority . . . . . . . . . . . . . . . . . . . . . . . 5-3

viii Contents
Suggested Workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4

Set Priority and Initial Target for Block Variables . . . . . . . . 5-5

Initialize Variables for a Mass-Spring-Damper System . . . . 5-7

Variable Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23


About Variable Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23
Advanced Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
Switching Between Tree View and Flat View . . . . . . . . . . . 5-27
Useful Filtering Techniques . . . . . . . . . . . . . . . . . . . . . . . . 5-29
Link to Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-30
Interaction with Model Updates and Simulation . . . . . . . . . 5-31

Linearization and Trimming


6
Finding an Operating Point . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
What Is an Operating Point? . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Finding Operating Points in Physical Models . . . . . . . . . . . . 6-3

Linearizing at an Operating Point . . . . . . . . . . . . . . . . . . . . . 6-7


What Is Linearization? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Linearizing a Physical Model . . . . . . . . . . . . . . . . . . . . . . . . 6-9

Linearize an Electronic Circuit . . . . . . . . . . . . . . . . . . . . . . . 6-13


Explore the Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13
Linearize with Steady-State Solver and linmod Function . . . 6-17
Linearize with Simulink Control Design Software . . . . . . . . 6-19
Use Control System Toolbox Software for Bode Analysis . . . 6-20

Linearize a Plant Model for Use in Feedback Control


Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23
Explore the Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23
Trim Using the Controller and Linearize with Simulink linmod
Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-26
Linearize with Simulink Control Design Software . . . . . . . . 6-27

ix
Real-Time Simulation
7
Model Preparation Objectives . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Obtain Reference Results . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Determine Step Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
Adjust Model Fidelity or Scope . . . . . . . . . . . . . . . . . . . . . . . 7-2

Real-Time Model Preparation Workflow . . . . . . . . . . . . . . . . 7-5


Prepare Your Model for Real-Time Simulation . . . . . . . . . . . 7-6
Insufficient Computational Capability for Workflow
Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8

Improving Speed and Accuracy . . . . . . . . . . . . . . . . . . . . . . . 7-10


Why Speed and Accuracy Matter for Real-Time Simulation . 7-10
Balancing Speed and Accuracy . . . . . . . . . . . . . . . . . . . . . . 7-11
Eliminating Effects That Require Intensive Computation . . 7-12
Optimizing Local and Global Solver Configurations . . . . . . . 7-13
Upgrading Target Hardware . . . . . . . . . . . . . . . . . . . . . . . . 7-13
Simulating Parts of the System in Parallel . . . . . . . . . . . . . 7-13

Determine Step Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-15

Reduce Computation Costs . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25


Data Logging and Monitoring Guidelines . . . . . . . . . . . . . . 7-25
Improve Data Logging and Monitoring Efficiency . . . . . . . . 7-25
Additional Methods for Reducing Computational Cost . . . . . 7-29

Reduce Numerical Stiffness . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31


Why Reduce Stiffness? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31
Review Reference Results . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31
Identify and Modify a Stiff Element . . . . . . . . . . . . . . . . . . 7-34
Analyze Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-36

Reduce Zero Crossings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-41


Why Reduce Zero Crossings? . . . . . . . . . . . . . . . . . . . . . . . . 7-41
Obtain Reference Results and Plot Simulation Step Size . . . 7-41
Identify and Modify Elements That Cause Zero Crossings . . 7-45
Analyze the Results of the Modified Model . . . . . . . . . . . . . 7-50

Fixed-Cost Simulation for Real-Time Viability . . . . . . . . . . 7-55

x Contents
Real-Time Simulation Workflow . . . . . . . . . . . . . . . . . . . . . . 7-57
Make Your Model Real-Time Viable . . . . . . . . . . . . . . . . . . 7-60
Insufficient Computational Capability for Real-Time
Viability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-62

Solvers for Real-Time Simulation . . . . . . . . . . . . . . . . . . . . . 7-63


Choosing Between Discrete and Continuous Solvers . . . . . . 7-64
Computational Cost for Continuous Solvers . . . . . . . . . . . . 7-64
How Numerical Stiffness Affects Solver Choice . . . . . . . . . . 7-65
Using Simscape Local Fixed-Step Solvers . . . . . . . . . . . . . . 7-66

Determine System Stiffness . . . . . . . . . . . . . . . . . . . . . . . . . . 7-68


Obtain Reference Results . . . . . . . . . . . . . . . . . . . . . . . . . . 7-68
Simulate with an Implicit Fixed-Step Solver . . . . . . . . . . . . 7-69
Simulate with an Explicit Fixed-Step Solver . . . . . . . . . . . . 7-71
Analyze the Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-73

Estimate Computation Costs . . . . . . . . . . . . . . . . . . . . . . . . . 7-76

Choose Step Size and Number of Iterations . . . . . . . . . . . . . 7-79


Obtain Reference Results . . . . . . . . . . . . . . . . . . . . . . . . . . 7-80
Determine Maximum Step Size for Accurate Results . . . . . . 7-82
Parameterize Global and Local Solver Settings . . . . . . . . . . 7-84
Perform Fixed-Step, Fixed-Cost Simulation . . . . . . . . . . . . . 7-85
Adjust Solver Settings to Improve Accuracy . . . . . . . . . . . . 7-89

What Is Hardware-in-the-Loop Simulation? . . . . . . . . . . . . . 7-96


Why Perform Hardware-in-the-Loop Simulation? . . . . . . . . 7-97

Hardware-in-the-Loop Simulation Workflow . . . . . . . . . . . 7-100


Perform Hardware-in-the-Loop Simulation . . . . . . . . . . . . 7-104
Insufficient Computational Capability for Hardware-in-the-
Loop Simulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-105

Code Generation Requirements . . . . . . . . . . . . . . . . . . . . . . 7-106


Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 7-106
Software Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-107

Generate, Download, and Execute Code . . . . . . . . . . . . . . . 7-108


Requirements for Building and Executing Simulink Real-Time
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-108
Create, Build, and Download a Real-Time Application . . . . 7-108
Execute Real-Time Application . . . . . . . . . . . . . . . . . . . . . 7-109

xi
Requirements for Using Alternative Platforms . . . . . . . . . 7-111
Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 7-111
Software Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-111

Code Generation
8
About Code Generation from Simscape Models . . . . . . . . . . . 8-2

Reasons for Generating Code . . . . . . . . . . . . . . . . . . . . . . . . . 8-3

Using Code-Related Products and Features . . . . . . . . . . . . . 8-4

How Simscape Code Generation Differs from Simulink . . . . 8-5


Simscape and Simulink Code Generated Separately . . . . . . . 8-5
Compiler and Processor Architecture Requirements . . . . . . . 8-5
Precompiled Libraries Provided for Selected Compilers . . . . . 8-5
Simscape Code Reuse Not Supported . . . . . . . . . . . . . . . . . . 8-6
Tunable Parameters Not Supported . . . . . . . . . . . . . . . . . . . 8-6
Simscape Run-Time Parameter Inlining Override of Global
Exceptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6

Data Logging
9
About Simulation Data Logging . . . . . . . . . . . . . . . . . . . . . . . 9-2
Suggested Workflows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3

Enable Data Logging for the Whole Model . . . . . . . . . . . . . . . 9-4

Log Data for Selected Blocks Only . . . . . . . . . . . . . . . . . . . . . 9-5

Data Logging Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6

Log and Plot Simulation Data . . . . . . . . . . . . . . . . . . . . . . . . . 9-8

xii Contents
Log Simulation Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-13

Log and View Simulation Data for Selected Blocks . . . . . . 9-17

Log, Navigate, and Plot Simulation Data . . . . . . . . . . . . . . . 9-21

About the Simscape Results Explorer . . . . . . . . . . . . . . . . . . 9-26

Use Custom Units to Plot Simulation Data . . . . . . . . . . . . . 9-27

View Sparkline Plots of Simulation Data . . . . . . . . . . . . . . . 9-31

Model Statistics
10
Simscape Model Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-2

1-D Physical System Statistics . . . . . . . . . . . . . . . . . . . . . . . . 10-4

3-D Multibody System Statistics . . . . . . . . . . . . . . . . . . . . . . 10-7

1-D/3-D Interface Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . 10-10

View Model Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11

Access Block Variables Using Statistics Viewer . . . . . . . . 10-16

Physical Units
11
How to Work with Physical Units . . . . . . . . . . . . . . . . . . . . . 11-2

Unit Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-4

How to Specify Units in Block Dialogs . . . . . . . . . . . . . . . . . 11-9

xiii
Thermal Unit Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . 11-11
About Affine Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-11
When to Apply Affine Conversion . . . . . . . . . . . . . . . . . . . 11-11
How to Apply Affine Conversion . . . . . . . . . . . . . . . . . . . . 11-12

Angular Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-15


References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-15

Units for Angular Velocity and Frequency . . . . . . . . . . . . . 11-16

Add-On Product License Management


12
About the Simscape Editing Mode . . . . . . . . . . . . . . . . . . . . 12-2
Suggested Workflows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-2
What You Can Do in Restricted Mode . . . . . . . . . . . . . . . . . 12-3
What You Can Do in Full Mode . . . . . . . . . . . . . . . . . . . . . 12-4
Switching Between Modes . . . . . . . . . . . . . . . . . . . . . . . . . . 12-4
Working with Block Libraries . . . . . . . . . . . . . . . . . . . . . . . 12-7

Set the Model Loading Preference . . . . . . . . . . . . . . . . . . . . 12-9

Save a Model in Restricted Mode . . . . . . . . . . . . . . . . . . . . 12-11


Example of Saving a Model in Restricted Mode . . . . . . . . . 12-12

Work with a Model in Restricted Mode . . . . . . . . . . . . . . . 12-14


How to Simulate and Fine-Tune a Model in Restricted
Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-14
How to Add and Delete Simulink Blocks in Restricted Mode 12-19
Performing an Operation Disallowed in Restricted Mode . . 12-24

Switch from Restricted to Full Mode . . . . . . . . . . . . . . . . . 12-28

Editing Mode Information . . . . . . . . . . . . . . . . . . . . . . . . . . 12-30


What Is the Current Mode? . . . . . . . . . . . . . . . . . . . . . . . . 12-30
Which Licenses Are Checked Out? . . . . . . . . . . . . . . . . . . 12-30

xiv Contents
1

Model Construction

• “Basic Principles of Modeling Physical Networks” on page 1-2


• “Simscape Block Libraries” on page 1-11
• “Essential Physical Modeling Techniques” on page 1-15
• “Creating and Simulating a Simple Model” on page 1-18
• “Modeling Best Practices” on page 1-36
• “Domain-Specific Line Styles” on page 1-43
• “Modeling Pneumatic Systems” on page 1-46
1 Model Construction

Basic Principles of Modeling Physical Networks


In this section...
“Overview of the Physical Network Approach to Modeling Physical Systems” on page
1-2
“Variable Types” on page 1-4
“Building the Mathematical Model” on page 1-5
“Direction of Variables ” on page 1-6
“Connector Ports and Connection Lines” on page 1-8
“Connecting Simscape Diagrams to Simulink Sources and Scopes” on page 1-9

Overview of the Physical Network Approach to Modeling Physical


Systems
Simscape™ software is a set of block libraries and special simulation features for
modeling physical systems in the Simulink® environment. It employs the Physical
Network approach, which differs from the standard Simulink modeling approach and is
particularly suited to simulating systems that consist of real physical components.

Simulink blocks represent basic mathematical operations. When you connect Simulink
blocks together, the resulting diagram is equivalent to the mathematical model, or
representation, of the system under design. Simscape technology lets you create a
network representation of the system under design, based on the Physical Network
approach. According to this approach, each system is represented as consisting of
functional elements that interact with each other by exchanging energy through their
ports.

These connection ports are nondirectional. They mimic physical connections between
elements. Connecting Simscape blocks together is analogous to connecting real
components, such as pumps, valves, and so on. In other words, Simscape diagrams mimic
the physical system layout. If physical components can be connected, their models can
be connected, too. You do not have to specify flow directions and information flow when
connecting Simscape blocks, just as you do not have to specify this information when you
connect real physical components. The Physical Network approach, with its Through and
Across variables and nondirectional physical connections, automatically resolves all the
traditional issues with variables, directionality, and so on.

1-2
Basic Principles of Modeling Physical Networks

The number of connection ports for each element is determined by the number of energy
flows it exchanges with other elements in the system, and depends on the level of
idealization. For example, a fixed-displacement hydraulic pump in its simplest form can
be represented as a two-port element, with one energy flow associated with the inlet
(suction) and the other with the outlet. In this representation, the angular velocity of
the driving shaft is assumed constant, making it possible to neglect the energy exchange
between the pump and the shaft. To account for a variable driving torque, you need a
third port associated with the driving shaft.

An energy flow is characterized by its variables. Each energy flow is associated with
two variables, one Through and one Across (see “Variable Types” on page 1-4 for
more information). Usually, these are the variables whose product is the energy flow in
watts. They are called the basic, or conjugate, variables. For example, the basic variables
for mechanical translational systems are force and velocity, for mechanical rotational
systems—torque and angular velocity, for hydraulic systems—flow rate and pressure, for
electrical systems—current and voltage.

The following example illustrates a Physical Network representation of a double-acting


hydraulic cylinder.

The element is represented with three energy flows: two flows of hydraulic energy
through the inlet and outlet of the cylinder and a flow of mechanical energy associated
with the rod motion. It therefore has the following three connector ports:

• A — Hydraulic conserving port associated with pressure p1 (an Across variable) and
flow rate q1 (a Through variable)
• B — Hydraulic conserving port associated with pressure p2 (an Across variable) and
flow rate q2 (a Through variable)

1-3
1 Model Construction

• R — Mechanical translational conserving port associated with rod velocity v3 (an


Across variable) and force F3 (a Through variable)

See “Connector Ports and Connection Lines” on page 1-8 for more information on
connector port types.

Variable Types
Physical Network approach supports two types of variables:

• Through — Variables that are measured with a gauge connected in series to an


element.
• Across — Variables that are measured with a gauge connected in parallel to an
element.

The following table lists the Through and Across variables associated with each type of
physical domain in Simscape software:

Physical Domain Across Variable Through Variable


Electrical Voltage Current
Hydraulic Pressure Flow rate
Magnetic Magnetomotive force (mmf) Flux
Mechanical rotational Angular velocity Torque
Mechanical translational Translational velocity Force
Pneumatic Pressure and temperature Mass flow rate and heat flow
Thermal Temperature Heat flow
Thermal liquid Pressure and temperature Mass flow rate and thermal
flux
Two-phase fluid Pressure and specific Mass flow rate and heat flow
internal energy rate

Note Generally, the product of each pair of Across and Through variables associated with
a domain is power (energy flow in watts). The exceptions are pneumatic domain (where
the product of pressure and mass flow rate is not power), magnetic domain (where the
product of mmf and flux is not power, but energy), and the two thermodynamic domains,

1-4
Basic Principles of Modeling Physical Networks

thermal liquid and two-phase fluid (where products of both variable pairs are not power).
These result in a pseudo-bond graph.

Building the Mathematical Model


Through and Across variables associated with all the energy flows form the basis of the
mathematical model of the block.

For example, the model of a double-acting hydraulic cylinder shown in the previous
illustration can be described with a simple set of equations:

F3 = p1 i A1 - p2 i A2

q1 = A1 iv3

q2 = A2 iv3

where

q1,q2 Flow rates through ports A and B, respectively (Through variables)


p1,p2 Gauge pressures at ports A and B, respectively (Across variables)
A1,A2 Piston effective areas
F3 Rod force (Through variable)
v3 Rod velocity (Across variable)

1-5
1 Model Construction

The model could be considerably more complex, for example, it could account for friction,
fluid compressibility, inertia of the moving parts, and so on. For all these different
mathematical models, however, the element configuration (that is, the number and
type of ports and the associated Through and Across variables) would remain the same,
meaning that the Physical Network approach lets you substitute models of different
levels of complexity without introducing any changes to the schematic. For example, you
can start developing your system by using the Resistive Tube block from the Foundation
library, which accounts only for friction losses. At a later stage in development, you
may want to account for fluid compressibility. You can then replace it with a Hydraulic
Pipeline block, available with SimHydraulics® block libraries, or, depending on your
application, even with a Segmented Pipeline block if you also need to account for fluid
inertia. This modeling principle is called incremental modeling.

Direction of Variables
Each variable is characterized by its magnitude and sign. The sign is the result of
measurement orientation. The same variable can be positive or negative, depending on
the polarity of a measurement gauge.

Elements with only two ports are characterized with one pair of variables, a Through
variable and an Across variable. Since these variables are closely related, their
orientation is defined with one direction. For example, if an element is oriented from port
A to port B, it implies that the Through variable (TV) is positive if it “flows” from A to B,
and the Across variable is determined as AV = AVA – AVB, where AVA and AVB are the
element node potentials or, in other words, the values of this Across variable at ports A
and B, respectively.

1-6
Basic Principles of Modeling Physical Networks

This approach to the direction of variables has the following benefits:

• Provides a simple and consistent way to determine whether an element is active or


passive. Energy is one of the most important characteristics to be determined during
simulation. If the variables direction, or sign, is determined as described above,
their product (that is, the energy) is positive if the element consumes energy, and
is negative if it provides energy to a system. This rule is followed throughout the
Simscape software.
• Simplifies the model description. Symbol A → B is enough to specify variable polarity
for both the Across and the Through variables.
• Lets you apply the oriented graph theory to network analysis and design.

As an example of variables direction rules, let us consider the Ideal Force Source block.
In this block, as in many other mechanical blocks, port C is associated with the source
reference point (case), and port R is associated with the rod.

The block positive direction is from port C to port R. This means that the force is positive
if it acts in the direction from C to R, and causes bodies connected to port R to accelerate
in the positive direction. The relative velocity is determined as v = vC – vR, where vR, vC
are the absolute velocities at ports R and C, respectively, and it is negative if velocity
at port R is greater than that at port C. The power generated by the source is computed
as the product of force and velocity, and is negative if the source provides energy to the
system.

Definition of positive direction is different for different blocks. Check the block source or
the block reference page if in doubt about the block orientation and direction of variables.

All the elements in a network are divided into active and passive elements, depending
on whether they deliver energy to the system or dissipate (or store) it. Active elements

1-7
1 Model Construction

(force and velocity sources, flow rate and pressure sources, etc.) must be oriented strictly
in accordance with the line of action or function that they are expected to perform in
the system, while passive elements (dampers, resistors, springs, pipelines, etc.) can be
oriented either way.

Connector Ports and Connection Lines


Simscape blocks may have the following types of ports:

• Physical conserving ports — Nondirectional ports (for example, hydraulic or


mechanical) that represent physical connections and relate physical variables based
on the Physical Network approach.
• Physical signal ports — Unidirectional ports transferring signals that use an internal
Simscape engine for computations.

Each of these ports and connections between them are described in greater detail below.

Physical Conserving Ports

Simscape blocks have special conserving ports . You connect conserving ports with
physical connection lines, distinct from normal Simulink lines. Physical connection lines
have no inherent directionality and represent the exchange of energy flows, according to
the Physical Network approach.

• You can connect conserving ports only to other conserving ports of the same type.
• The physical connection lines that connect conserving ports together are
nondirectional lines that carry physical variables (Across and Through variables, as
described above) rather than signals. You cannot connect physical lines to Simulink
ports or to physical signal ports.
• Two directly connected conserving ports must have the same values for all their
Across variables (such as pressure or angular velocity).
• You can branch physical connection lines. When you do so, components directly
connected with one another continue to share the same Across variables. Any
Through variable (such as flow rate or torque) transferred along the physical
connection line is divided among the multiple components connected by the branches.
How the Through variable is divided is determined by the system dynamics.

For each Through variable, the sum of all its values flowing into a branch point equals
the sum of all its values flowing out.

1-8
Basic Principles of Modeling Physical Networks

Each type of physical conserving ports used in Simscape blocks uniquely represents a
physical modeling domain. For a list of port types, along with the Through and Across
variables associated with each type, see the table in “Variable Types” on page 1-4.

For improved readability of block diagrams, each Simscape domain uses a distinct
default color and line style for the connection lines. For more information, see “Domain-
Specific Line Styles” on page 1-43.

Physical Signal Ports

Physical signal ports carry signals between Simscape blocks. You connect them with
regular connection lines, similar to Simulink signal connections. Physical signal ports
are used in Simscape block diagrams instead of Simulink input and output ports to
increase computation speed and avoid issues with algebraic loops. Unlike Simulink
signals, which are essentially unitless, physical signals can have units associated with
them. You specify the units along with the parameter values in the block dialogs, and
Simscape software performs the necessary unit conversion operations when solving a
physical network.

Simscape Foundation library contains, among other sublibraries, a Physical Signals


block library. These blocks perform math operations and other functions on physical
signals, and allow you to graphically implement equations inside the Physical Network.

Physical signal lines also have a distinct style and color in block diagrams, similar to
physical connection lines. For more information, see “Domain-Specific Line Styles” on
page 1-43.

Connecting Simscape Diagrams to Simulink Sources and Scopes


Simscape block diagrams use physical signals instead of regular Simulink signals.
Therefore, you need converter blocks to connect Simscape diagrams to Simulink sources
and scopes.

Use the Simulink-PS Converter block to connect Simulink sources or other Simulink
blocks to the inputs of a Physical Network diagram. You can also use it to specify the
input signal units. For more information, see the Simulink-PS Converter block
reference page.

Use the PS-Simulink Converter block to connect outputs of a Physical Network diagram
to Simulink scopes or other Simulink blocks. You can also use it to specify the desired

1-9
1 Model Construction

output signal units. For more information, see the PS-Simulink Converter block
reference page.

For an example of using converter blocks to connect Simscape diagrams to Simulink


sources and scopes, see “Creating and Simulating a Simple Model” on page 1-18.

1-10
Simscape Block Libraries

Simscape Block Libraries


In this section...
“Library Structure Overview” on page 1-11
“Using the Simulink Library Browser to Access the Block Libraries” on page 1-12
“Using the Command Prompt to Access the Block Libraries” on page 1-13

Library Structure Overview


Simscape block library contains two libraries that belong to the Simscape product:

• Foundation library — Contains basic hydraulic, pneumatic, mechanical, electrical,


magnetic, thermal, thermal liquid, and physical signal blocks, organized into
sublibraries according to technical discipline and function performed
• Utilities library — Contains essential environment blocks for creating Physical
Networks models

In addition, if you have installed any of the add-on products of the Physical Modeling
family, you will see the corresponding libraries under the main Simscape library.

Simscape Foundation libraries contain a comprehensive set of basic elements and


building blocks, such as:

• Mechanical building blocks for representing one-dimensional translational and


rotational motion
• Electrical building blocks for representing electrical components and circuits
• Magnetic building blocks that represent electromagnetic components
• Hydraulic building blocks that model fundamental hydraulic effects and can be
combined to create more complex hydraulic components
• Pneumatic building blocks that model fundamental pneumatic effects based on the
ideal gas law
• Thermal building blocks that model fundamental thermal effects
• Thermal liquid building blocks that model fundamental thermodynamic effects in
liquids
• Two-phase fluid building blocks that model fundamental thermodynamic effects in
systems where the working agent is part liquid and part vapor

1-11
1 Model Construction

• Physical Signals block library that lets you perform math operations on physical
signals, and graphically enter equations inside the physical network

Using the elements contained in these Foundation libraries, you can create more complex
components that span different physical domains. You can then group this assembly of
blocks into a subsystem and parameterize it to reuse and share these components.

In addition to Foundation libraries, there is also a Simscape Utilities library, which


contains utility blocks, such as:

• Solver Configuration block, which contains parameters relevant to numerical


algorithms for Simscape simulations. Each Simscape diagram (or each topologically
distinct physical network in a diagram) must contain a Solver Configuration block.
• Simulink-PS Converter block and PS-Simulink Converter block, to connect Simscape
and Simulink blocks. Use the Simulink-PS Converter block to connect Simulink
outports to Physical Signal inports. Use the PS-Simulink Converter block to connect
Physical Signal outports to Simulink inports.

For examples of using these blocks in a Simscape model, see the tutorial “Creating and
Simulating a Simple Model” on page 1-18.

You can combine all these blocks in your Simscape diagrams to model physical systems.
You can also use the basic Simulink blocks in your diagrams, such as sources or scopes.
See “Connecting Simscape Diagrams to Simulink Sources and Scopes” on page 1-9 for
more information on how to do this.

Simscape block libraries contain a comprehensive selection of blocks that represent


engineering components such as valves, resistors, springs, and so on. These prebuilt
blocks, however, may not be sufficient to address your particular engineering needs.
When you need to extend the existing block libraries, use the Simscape language to
define customized components, or even new physical domains, as textual files. Then
convert your textual components into libraries of additional Simscape blocks that you
can use in your model diagrams. For more information on how to do this, see “Typical
Simscape Language Tasks”.

Using the Simulink Library Browser to Access the Block Libraries


You can access the blocks through the Simulink Library Browser. To display the Library
Browser, click the Simulink Library button in the toolbar of the MATLAB® desktop.

1-12
Simscape Block Libraries

Alternatively, you can type simulink in the MATLAB Command Window. Then expand
the Simscape entry in the contents tree.

Using the Command Prompt to Access the Block Libraries


To access individual block libraries by using the command prompt:

• To open the Simscape library, type simscape in the MATLAB Command Window.
• To open the main Simulink library (to access generic Simulink blocks), type
simulink in the MATLAB Command Window.

The Simscape library consists of two top-level libraries, Foundation and Utilities. In
addition, if you have installed any of the add-on products of the Physical Modeling
family, you will see the corresponding libraries under Simscape library, as shown in
the following illustration. Some of these libraries contain second-level and third-level
sublibraries. You can expand each library by double-clicking its icon.

1-13
1 Model Construction

1-14
Essential Physical Modeling Techniques

Essential Physical Modeling Techniques


Building Your Model
The rules that you must follow when building a physical model with Simscape software
are described in “Basic Principles of Modeling Physical Networks” on page 1-2. This
section briefly reviews these rules.

• Build your physical model by using a combination of blocks from the Simscape
Foundation and Utilities libraries. Simscape software lets you create a network
representation of the system under design, based on the Physical Network approach.
According to this approach, each system is represented as consisting of functional
elements that interact with each other by exchanging energy through their ports.
• Each Simscape diagram (or each topologically distinct physical network in a diagram)
must contain a Solver Configuration block from the Simscape Utilities library.
• If you have hydraulic elements in your model, the working fluid used in the hydraulic
circuit defines their global parameters, such as fluid density, fluid kinematic
viscosity, fluid bulk modulus, and so on. To specify the working fluid, attach a Custom
Hydraulic Fluid block (or a Hydraulic Fluid block, available with SimHydraulics block
libraries) to each topologically distinct hydraulic circuit. If no Hydraulic Fluid block
or Custom Hydraulic Fluid block is attached to a circuit, the hydraulic blocks use the
default fluid, which is equivalent to fluid defined by a Custom Hydraulic Fluid block
with the default parameter values.
• If you have pneumatic elements in your model, default gas properties are for dry air
and ambient conditions of 101325 Pa and 20 degrees Celsius. Attach a Gas Properties
block to each topologically distinct pneumatic circuit to change gas properties and
ambient conditions.
• To connect regular Simulink blocks (such as sources or scopes) to your physical
network diagram, use the converter blocks, as described in “Using the Physical Signal
Ports” on page 1-16.
• Use the incremental modeling approach. Start with a simple model, run and
troubleshoot it, then add the desired special effects. For example, you can start
developing your system by using the Resistive Tube block from the Foundation
library, which accounts only for friction losses. At a later stage in development,
you may want to account for fluid compressibility. You can then replace it with
a Hydraulic Pipeline block, available with SimHydraulics block libraries, or,
depending on your application, even with a Segmented Pipeline block if you also
need to account for fluid inertia. For all these different mathematical models, the

1-15
1 Model Construction

element configuration (that is, the number and type of ports and the associated
Through and Across variables) would remain the same, meaning that the Physical
Network approach lets you substitute models of different levels of complexity without
introducing any changes to the schematic.

Simscape blocks, in general, feature both Conserving ports and Physical Signal inports
and outports .

Using the Conserving Ports


The following rules apply to Conserving ports:

• There are different types of Physical Conserving ports used in Simscape block
diagrams, such as hydraulic, pneumatic, electrical, mechanical translational,
mechanical rotational, and so on. Each type has specific Through and Across variables
associated with it. For more information, see “Variable Types” on page 1-4.
• You can connect Conserving ports only to other Conserving ports of the same type.
Domain-specific line styles and colors help distinguish between different domains and
facilitate the connection process. For more information, see “Domain-Specific Line
Styles” on page 1-43.
• The Physical connection lines that connect Conserving ports together are
nondirectional lines that carry physical variables (Across and Through variables, as
described above) rather than signals. You cannot connect Physical lines to Simulink
ports or to Physical Signal ports.
• Two directly connected Conserving ports must have the same values for all their
Across variables (such as voltage or angular velocity).
• You can branch Physical connection lines. When you do so, components directly
connected with one another continue to share the same Across variables. Any
Through variable (such as current or torque) transferred along the Physical
connection line is divided among the multiple components connected by the branches.
How the Through variable is divided is determined by the system dynamics.

For each Through variable, the sum of all its values flowing into a branch point equals
the sum of all its values flowing out.

Using the Physical Signal Ports


The following rules apply to Physical Signal ports:

1-16
Essential Physical Modeling Techniques

• You can connect Physical Signal ports to other Physical Signal ports with regular
connection lines, similar to Simulink signal connections. These connection lines carry
physical signals between Simscape blocks.
• You can connect Physical Signal ports to Simulink ports through special converter
blocks. Use the Simulink-PS Converter block to connect Simulink outports to Physical
Signal inports. Use the PS-Simulink Converter block to connect Physical Signal
outports to Simulink inports.
• Unlike Simulink signals, which are essentially unitless, Physical Signals can have
units associated with them. Simscape block dialogs let you specify the units along
with the parameter values, where appropriate. Use the converter blocks to associate
units with an input signal and to specify the desired output signal units.

For examples of applying these rules when creating an actual physical model, see the
tutorial “Creating and Simulating a Simple Model” on page 1-18.

1-17
1 Model Construction

Creating and Simulating a Simple Model


In this section...
“Building a Simscape Diagram” on page 1-18
“Modifying Initial Settings” on page 1-26
“Running the Simulation” on page 1-28
“Adjusting the Parameters” on page 1-30

Building a Simscape Diagram


In this example, you are going to model a simple mechanical system and observe its
behavior under various conditions. This tutorial illustrates the essential steps to building
a physical model and makes you familiar with using the basic Simscape blocks.

The following schematic represents a simple model of a car suspension. It consists of a


spring and damper connected to a body (represented as a mass), which is agitated by a
force. You can vary the model parameters, such as the stiffness of the spring, the mass of
the body, or the force profile, and view the resulting changes to the velocity and position
of the body.

1-18
Creating and Simulating a Simple Model

To create an equivalent Simscape diagram, follow these steps:

1 Open the Simulink Library Browser, as described in “Simscape Block Libraries” on


page 1-11.
2 Create a new model. To do this, from the top menu bar of the Library Browser, select
File > New > Model. The software creates an empty model in memory and displays
it in a new model editor window.

Note Alternately, you can type ssc_new at the MATLAB Command prompt, to
create a new model prepopulated with certain required and commonly-used blocks.
For more information, see “Creating a New Simscape Model”.
3 Open the Simscape > Foundation Library > Mechanical > Translational Elements
library.
4 Drag the Mass, Translational Spring, Translational Damper, and two Mechanical
Translational Reference blocks into the model window.
5 Orient the blocks as shown in the following illustration. To rotate a block, select it
and press Ctrl+R.

1-19
1 Model Construction

6 Connect the Translational Spring, Translational Damper, and Mass blocks to one of
the Mechanical Translational Reference blocks as shown in the next illustration.

1-20
Creating and Simulating a Simple Model

7 To add the representation of the force acting on the mass, open the Simscape >
Foundation Library > Mechanical > Mechanical Sources library and add the Ideal
Force Source block to your diagram.

To reflect the correct direction of the force shown in the original schematic, flip the
block by selecting Diagram > Rotate & Flip > Flip Block > Up-Down from the
top menu bar of the model window. Connect the block's port C (for “case”) to the
second Mechanical Translational Reference block, and its port R (for “rod”) to the
Mass block, as shown below.

1-21
1 Model Construction

8 Add the sensor to measure speed and position of the mass. Place the Ideal
Translational Motion Sensor block from the Mechanical Sensors library into your
diagram and connect it as shown below.

1-22
Creating and Simulating a Simple Model

9 Now you need to add the sources and scopes. They are found in the regular Simulink
libraries. Open the Simulink > Sources library and copy the Signal Builder block
into the model. Then open the Simulink > Sinks library and copy two Scope blocks.
Rename one of the Scope blocks to Velocity and the other to Position.

1-23
1 Model Construction

10 Every time you connect a Simulink source or scope to a Simscape diagram, you have
to use an appropriate converter block, to convert Simulink signals into physical
signals and vice versa. Open the Simscape > Utilities library and copy a Simulink-PS
Converter block and two PS-Simulink Converter blocks into the model. Connect the
blocks as shown below.

1-24
Creating and Simulating a Simple Model

11 Each topologically distinct physical network in a diagram requires exactly one Solver
Configuration block, found in the Simscape > Utilities library. Copy this block into
your model and connect it to the circuit by creating a branching point and connecting
it to the only port of the Solver Configuration block. Your diagram now should look
like this.

1-25
1 Model Construction

12 Your block diagram is now complete. Save it as mech_simple.

Modifying Initial Settings


After you have put together a block diagram of your model, as described in the previous
section, you need to select a solver and provide the correct values for configuration
parameters.

To prepare for simulating the model, follow these steps:

1-26
Creating and Simulating a Simple Model

1 Select a Simulink solver. On the top menu bar of the model window, select
Simulation > Model Configuration Parameters. The Configuration Parameters
dialog box opens, showing the Solver node.

Under Solver options, set Solver to ode23t (mod.stiff/Trapezoidal).

Expand Additional options and set Max step size to 0.2.

Also note that Simulation time is specified to be between 0 and 10 seconds. You can
adjust this setting later, if needed.

Click OK to close the Configuration Parameters dialog box.


2 Save the model.

1-27
1 Model Construction

Running the Simulation


After you've put together a block diagram and specified the initial settings for your
model, you can run the simulation.

1 The input signal for the force is provided by the Signal Builder block. The signal
profile is shown in the illustration below. It starts with a value of 0, then at 4
seconds there is a step change to 1, and then it changes back to 0 at 6 seconds. This
is the default profile.

The Velocity scope outputs the mass velocity, and the Position scope outputs the
mass displacement as a function of time. Double-click both scopes to open them.
2
To run the simulation, click in the model window toolbar. The Simscape solver
evaluates the model, calculates the initial conditions, and runs the simulation. For a

1-28
Creating and Simulating a Simple Model

detailed description of this process, see “How Simscape Simulation Works” on page
4-5. Completion of this step may take a few seconds. The message in the bottom-
left corner of the model window provides the status update.
3 Once the simulation starts running, the Velocity and Position scope windows display
the simulation results, as shown in the next illustration.

1-29
1 Model Construction

In the beginning, the mass is at rest. Then at 4 seconds, as the input signal changes
abruptly, the mass velocity spikes in the positive direction and gradually returns
to zero. The mass position at the same time changes more gradually, on account
of inertia and damping, and stays at the new value as long as the force is acting
upon it. At 6 seconds, when the input signal changes back to zero, the velocity gets a
mirror spike, and the mass gradually returns to its initial position.

You can now adjust various inputs and block parameters and see their effect on the mass
velocity and displacement.

Adjusting the Parameters


After running the initial simulation, you can experiment with adjusting various inputs
and block parameters.

Try the following adjustments:

1 Change the force profile.


2 Change the model parameters.
3 Change the mass position output units.

Changing the Force Profile

This example shows how a change in the input signal affects the force profile, and
therefore the mass displacement.

1 Double-click the Signal Builder block to open it.


2 Click the first vertical segment of the signal profile and drag it from 4 to 2 seconds,
as shown below. Close the block dialog.

1-30
Creating and Simulating a Simple Model

3 Run the simulation. The simulation results are shown in the following illustration.

1-31
1 Model Construction

Changing the Model Parameters

In our model, the force acts on a mass against a translational spring and damper,
connected in parallel. This example shows how changes in the spring stiffness and
damper viscosity affect the mass displacement.

1 Double-click the Translational Spring block. Set its Spring rate to 2000 N/m.

1-32
Creating and Simulating a Simple Model

2 Run the simulation. The increase in spring stiffness results in smaller amplitude of
mass displacement, as shown in the following illustration.

3 Next, double-click the Translational Damper block. Set its Damping coefficient to
500 N/(m/s).
4 Run the simulation. Because of the increase in viscosity, the mass is slower both
in reaching its maximum displacement and in returning to the initial position, as
shown in the following illustration.

1-33
1 Model Construction

Changing the Mass Position Output Units

In our model, we have used the PS-Simulink Converter block in its default parameter
configuration, which does not specify units. Therefore, the Position scope outputs the
mass displacement in the default length units, that is, in meters. This example shows
how to change the output units for the mass displacement to millimeters.

1 Double-click the PS-Simulink Converter1 block. Type mm in the Output signal unit
combo box and click OK.
2 Run the simulation. In the Position scope window, click to autoscale the scope
axes. The mass displacement is now output in millimeters, as shown in the following
illustration.

1-34
Creating and Simulating a Simple Model

More About
• “Basic Principles of Modeling Physical Networks” on page 1-2
• “Modeling Best Practices” on page 1-36

1-35
1 Model Construction

Modeling Best Practices

In this section...
“Grounding Rules” on page 1-36
“Avoiding Numerical Simulation Issues” on page 1-40

Grounding Rules
This section contains guidelines for using domain-specific reference blocks (such as
Electrical Reference, Mechanical Translational Reference, and so on) in Simscape
diagrams, along with examples of correct and incorrect configurations.

Add reference blocks to your models according to the following rules:

• “Each Domain Requires at Least One Reference Block” on page 1-36


• “Each Circuit Requires at Least One Reference Block” on page 1-37
• “Multiple Connections to the Domain Reference Are Allowed Within a Circuit” on
page 1-39

Each Domain Requires at Least One Reference Block

Within a physical network, each domain must contain at least one reference block of
the appropriate type. For example, the electromechanical model shown in the following
diagram has both Electrical Reference and Rotational Reference blocks attached to the
appropriate circuits.

1-36
Modeling Best Practices

Each Circuit Requires at Least One Reference Block

Each topologically distinct circuit within a domain must contain at least one reference
block. Some blocks, such as an Ideal Transformer, interface two parts of the network
but do not convey information about signal levels relative to the reference block. In the
following diagram, there are two separate electrical circuits, and the Electrical Reference
blocks are required on both sides of the Ideal Transformer block.

1-37
1 Model Construction

The next diagram would produce an error because it is lacking an electrical reference in
the circuit of the secondary winding.

The following diagram, however, will not produce an error because the resistor defines
the output voltage relative to the ground reference.

1-38
Modeling Best Practices

Multiple Connections to the Domain Reference Are Allowed Within a Circuit

More that one reference block may be used within a circuit to define multiple connections
to the domain reference:

• Electrical conserving ports of all the blocks that are directly connected to ground must
be connected to an Electrical Reference block.
• All translational ports that are rigidly clamped to the frame (ground) must be
connected to a Mechanical Translational Reference block.
• All rotational ports that are rigidly clamped to the frame (ground) must be connected
to a Mechanical Rotational Reference block.
• Hydraulic conserving ports of all the blocks that are referenced to atmosphere (for
example, suction ports of hydraulic pumps, or return ports of valves, cylinders,
pipelines, if they are considered directly connected to atmosphere) must be connected
to a Hydraulic Reference block.

For example, the following diagram correctly indicates two separate connections to an
electrical ground.

1-39
1 Model Construction

Avoiding Numerical Simulation Issues


Certain configurations of physical modeling blocks can cause numerical difficulties or
slow down your simulation. When this happens, Simscape solver issues a warning in the
MATLAB workspace and, if it fails to initialize, a Simscape error.

In electrical circuits, common examples that can cause this behavior include voltage
sources connected in parallel with capacitors, inductors connected in series with current
sources, voltage sources connected in parallel, and current sources connected in series.
Often, the cause of the numerical difficulty is immediately apparent. For example, two
voltage sources in parallel must have identical voltage values; otherwise, the ports
connecting them would not be physical conserving ports. In practical circuits, topologies
such as parallel voltage sources are possible, and small difference in their instantaneous
voltages is possible due to parasitic series resistance.

Note Mathematically, these topologies result in Index-2 differential algebraic equations


(DAEs). Their solution requires two differentiations of the constraint equations and, as
such, it is numerically better to avoid these component topologies where possible.

1-40
Modeling Best Practices

There are two approaches to resolving these difficulties. The first is to change the circuit
to an equivalent simpler one. In the example of two parallel voltage sources, one source
can be simply deleted. The same applies to two series current sources, the deleted one
being replaced by a short circuit. For some circuit topologies, however, it is not possible
to find an equivalent simpler one that resolves the problem, and the second approach is
needed.

The second approach is to include small parasitic resistances in the component. In


the Simscape Foundation library, the Capacitor and Inductor blocks include such
parasitic terms, so that you can connect capacitances in parallel with voltage sources and
inductors in series with current sources. If your circuit does not have any such topologies,
then you can change the default parasitic terms to zero. Note that other blocks do not
contain these parasitic terms, for example, the Mutual Inductor block. Therefore, if you
wanted to connect a mutual inductor primary in series with a current source, you would
need to introduce your own parasitic conductance across the primary winding.

Example of Using a Parasitic Resistance to Avoid Numerical Simulation Issues

The following diagram models a differentiator that might be used as part of a


Proportional-Integral-Derivative (PID) controller. You can open this model by typing
ssc_opamp_differentiator in the MATLAB Command Window.

Simulate the model, and you will see that the output is minus the derivative of the input
sinusoid.

1-41
1 Model Construction

Now open the capacitor C block dialog, and set the series resistance to zero. The model
now runs very slowly and issues warnings about problems with transient initialization
and step size control for transient solve.

The cause of the problems is that the circuit effectively connects the voltage source in
parallel with the capacitor. This is because an ideal op-amp satisfies V+ = V- , where V+
and V- are the noninverting and inverting inputs, respectively. This is an example where
it is not possible to replace the circuit with an equivalent simpler one, and a parasitic
small resistance has to be introduced.

1-42
Domain-Specific Line Styles

Domain-Specific Line Styles


For improved readability of block diagrams, each Simscape domain uses a distinct
default color and line style for the connection lines. Physical signal lines also have a
distinct style and color.

Domain-specific line styles apply to the block icons as well. If all the block ports belong
to the same domain, then the whole block icon assumes the line style and color of that
domain. If a block has multiple port types, such as the Rotational Electromechanical
Converter, then relevant parts of the block icon assume domain-specific line styles and
colors.

To view the line styles assigned to each domain, in a model window, from the top menu
bar, select Display > Simscape > Legend. The Simscape Line Styles Legend window
opens, listing the line color assigned to each registered domain, the domain name, and
the domain path. If you click a domain path link, the Simscape file for the corresponding
domain opens in MATLAB Editor. For more information on domain paths and files, see
“Foundation Domains”.

1-43
1 Model Construction

To turn off domain-specific line styles for a particular model, in the model window,
from the top menu bar, select Display > Simscape > Domain Styles. This action
clears the check mark next to the Domain Styles menu option, and the block diagram
display changes to black connection lines and block icons, with physical ports visible at
connection points. Repeatedly selecting the Domain Styles menu option toggles the
domain-specific line styles for this model on or off, as indicated by the check mark.

To turn off domain-specific line styles for all models, on the MATLAB Toolstrip, click
Preferences. In the left pane of the Preferences dialog box, select Simscape, then clear
the Enable domain styles for all models check box.

1-44
Domain-Specific Line Styles

1-45
1 Model Construction

Modeling Pneumatic Systems

In this section...
“Intended Applications” on page 1-46
“Assumptions and Limitations” on page 1-46
“Fundamental Equations” on page 1-47
“Network Variables” on page 1-48
“Connection Constraints” on page 1-48
“References” on page 1-49

Intended Applications
The Foundation library contains basic pneumatic elements, such as orifices, chambers,
and pneumatic-mechanical converters, as well as pneumatic sensors and sources. Use
these blocks to model pneumatic systems, for applications such as:

• Factory automation — basic pneumatic linear/rotational actuators, valves (variable


orifices), and air supply
• Robotics — robotic arms and haptic interfaces
• Gaseous transportation systems and pipelines

You can also use these blocks to model dry air and low-pressure flows, for example, for
HVAC applications.

Assumptions and Limitations


Pneumatic block models are based on the following assumptions:

• Working fluid is an ideal gas satisfying the ideal gas law.


• Specific heats at constant pressure and constant volume, cp and cv, are constant.
• Processes are adiabatic, that is, there is no heat transfer between components and the
environment (except for components with a separate thermal port).
• Gravitational effects can be neglected, that is, underlying equations contain no head
pressures due to gravity.

1-46
Modeling Pneumatic Systems

Fundamental Equations
The energy balance for a control volume [1] is

dEcv Ê Ê vi2 ˆˆ Ê Ê vo2 ˆˆ


dt
= Qcv - Wcv + Â ÁÁ mi ÁÁ hi + 2
+ gzi ˜ ˜ -
˜˜  ÁÁ mo ÁÁ ho + 2
+ gzo ˜ ˜
˜˜
i Ë Ë ¯¯ o Ë Ë ¯¯

where

Ecv Control volume total energy


Qcv Heat energy per second added to the gas through the boundary
Wcv Mechanical work per second performed by the gas
hi, ho Inlet and outlet enthalpies
vi, vo Gas inlet and outlet velocities
g Acceleration due to gravity
zi, zo Elevations at inlet and outlet ports
mi, mo Mass flow rates in and out of the control volume

The equation is an accounting balance for the energy of the control volume. It states
that the rate of energy increase or decrease within the control volume equals the
difference between the rates of energy transfer in and out across the boundary. The
mechanisms of energy transfer are heat and work, as for closed systems, and the energy
that accompanies the mass entering and exiting.

Pneumatic block models make several simplifying assumptions, as described previously.

The ideal gas law relates pressure, density, and temperature:

p = rRT

where

p Absolute pressure
ρ Gas density
R Specific gas constant

1-47
1 Model Construction

T Absolute gas temperature

Also, the specific enthalpies for an ideal gas at temperature T and constant pressure and
constant volume are given by:

h = cp T

h = cv T

The pneumatic components also use the mass continuity equation:

dr 1
= ( mi - mo )
dt V

where ρ is the density of the gas within the component. For components with no internal
mass of gas, the equation simplifies to:

G = mi = mo

where G is the mass flow rate through the component.

For specific equations used in each block, see the block reference pages.

Network Variables
The Across variables are pressure and temperature, and the Through variables are mass
flow rate and heat flow. Note that these choices result in a pseudo-bond graph, because
the product of pressure and mass flow rate is not power.

Connection Constraints
Every node in a pneumatic network must have a defined temperature as well as
pressure. This rule places some constraints on how you connect the pneumatic elements.
In effect, every node should have a volume of fluid associated with it. When the ideal gas
law is applied, this volume of fluid determines the relationship between temperature
and pressure. Some elements already have a volume of fluid associated with them,
and therefore having just one of these components connected to a node satisfies this

1-48
Modeling Pneumatic Systems

condition. Such blocks include Constant Volume Pneumatic Chamber, Pneumatic Piston
Chamber, Rotary Pneumatic Piston Chamber, and Pneumatic Atmospheric Reference.

An exception to the above rule (that every node must have a volume of fluid associated
with it) occurs when two nodes are connected by a component for which the heat equation
says that the temperatures are equal. In this case, just one of the nodes needs to be
connected to a component with associated volume of fluid. Such components include the
pressure and flow rate sources.

For models that represent an actual pneumatic network, these constraints should
have no impact. For example, connecting two orifices in series makes no physical sense
because the underlying assumption of the orifice equation is that gas is discharged into a
volume of fluid. Therefore, modeling actual physical systems should automatically satisfy
these constraints.

References
[1] Moran M.J. and Shapiro H.N. Fundamentals of Engineering Thermodynamics. Second
edition. New York: John Wiley & Sons, 1992.

1-49
2

Thermal Liquid Models

• “Modeling Thermal Liquid Systems” on page 2-2


• “Thermal Liquid Library” on page 2-6
• “Thermal Liquid Modeling Framework” on page 2-10
• “Heat Transfer in Insulated Oil Pipeline” on page 2-14
2 Thermal Liquid Models

Modeling Thermal Liquid Systems

In this section...
“When to Use Thermal Liquid Blocks” on page 2-2
“Modeling Workflow” on page 2-3
“Establish Model Requirements” on page 2-3
“Model Physical Components” on page 2-4
“Prepare Model for Analysis” on page 2-5
“Run Simulation” on page 2-5

When to Use Thermal Liquid Blocks


The Thermal Liquid library expands the fluid modeling capability of Simscape. With
this library, you can account for thermal effects in a fluid system. For example, you can
model the warming effect of viscous dissipation in a pipe. You can also account for the
temperature dependence of fluid properties, e.g., density and viscosity.

To decide whether Thermal Liquid blocks fit your modeling needs, consider the fluid
system you are trying to represent. Other Simscape blocks—e.g. Hydraulic or Pneumatic
—may better suit your application. Assess the following:

• Number of phases

Is the fluid medium single phase or multiphase?


• Relevant phases

Is the fluid medium a gas, a liquid, or a multiphase mixture?


• Thermal effects

Does temperature change significantly in the time scale of the simulation? Are
thermal effects important for analysis? Are the temperature dependences of the liquid
properties important?

As a rule, use Thermal Liquid blocks for fluid systems in which a single-phase liquid
experiences significant temperature changes. For gaseous systems, use Pneumatic blocks
instead. For isothermal liquid systems, use Hydraulic blocks.

2-2
Modeling Thermal Liquid Systems

Modeling Workflow
The suggested workflow for Thermal Liquid models includes four steps:

1 Establish model requirements — Define the purpose and scope of the model. Then,
identify the relevant components and interactions in the model. Use this information
as a guide when building the model.
2 Model physical components — Determine the appropriate blocks for modeling the
relevant components and interactions. Then, add the blocks to the model canvas
and connect them according to the Simscape connection rules. Specify the block
parameters.
3 Prepare model for analysis — Add sensors to the model. Alternatively, configure the
model for Simscape data logging. Check the physical units of each sensed variable.
4 Run simulation — Configure the solver settings. Then, run the simulation. If
necessary, refine the model until you achieve the desired fidelity level.

Establish Model Requirements


The foundation of a good model is a clear understanding of its purpose and requirements.
What are you trying to accomplish with the model? What are the relevant components,
processes, and states? Determine what is essential and what is not. Start simple, using
a rough approximation of the physical system as a guide. Then, iteratively add detail to
reach the appropriate model fidelity for your application.

An insulated oil pipeline buried underground provides an example. As oil flows


through the pipeline, it experiences conductive heat losses due to the cooler pipeline
surroundings. Heat flows across three material layers—pipe wall, insulant, and soil—
causing oil temperature to drop. However, only conduction across soil and insulant layers
matter. A typical pipe wall is thin and conductive, and its effect on conductive heat loss is
minimal at best. Omitting this process simplifies the model and speeds up simulation.

You also must determine the dimensions and properties of each component. During
modeling, you specify these parameters in the Simscape blocks for the components.
Obtain the physical properties of the liquid medium. Manufacturer data sheets typically
provide this data. You can also use analytical expressions to define the physical property
lookup tables.

When modeling pipes, consider the impact that dynamic compressibility and flow
inertia have on the transient system behavior. If the time scale of an effect exceeds
the simulation run time, the impact is usually negligible. During modeling, turn off

2-3
2 Thermal Liquid Models

negligible effects to improve simulation speed. Characteristic time scales for dynamic
compressibility and flow inertia are approximately L/c and L/v, respectively, where:

• L is the length of the pipe.


• v is the mean flow velocity through the pipe.
• c is the speed of sound in the liquid medium.

If you are unsure whether an effect is relevant to your model, simulate the model with
and without that effect. Then, compare the two simulation results. If the difference is
substantial, leave that effect in place. The result is greater model fidelity at small time
scales, e.g., during transients associated with flow reversal in a pipe.

Model Physical Components


Start by adding a Thermal Liquid Settings (TL) block to the model canvas. Use
this block to provide the physical properties of the liquid medium. This block is not
strictly required, but without it the liquid properties are reset to their default values,
given for water. In the block dialog box, enter the physical property lookup tables that
you acquired during the planning stage.

Identify the appropriate blocks for representing the physical components and their
interactions. Components can be simple, requiring a single block, or custom, requiring
multiple blocks typically within a Subsystem block. Add the blocks to the model canvas
and connect them according to the Simscape connection rules.

The ssc_tl_hydraulic_fluid_warming example shows simple and custom


components. The Mass Flow Rate Source (TL) represents an ideal power source.
It is a simple component. The Double-acting cylinder subsystem block represents the
mechanical part of a hydraulic actuator. It contains two Translational Mechanical
Converter (TL) blocks and is a custom component.

Once you have connected the blocks, specify the relevant parameters. These include
dimensions, physical states, empirical correlation coefficients, and initial conditions.
In Pipe (TL), Rotational Mechanical Converter (TL), and Translational
Mechanical Converter (TL) blocks, select the appropriate setting for effects such as
dynamic compressibility and flow inertia.

Note: For accurate simulation results, always replace the default parameter values with
data appropriate for your model.

2-4
Modeling Thermal Liquid Systems

Prepare Model for Analysis


To analyze a model, you must set up that model for data collection. The simplest
approach is to add sensor blocks to the model. The Thermal Liquid library provides two
sensor block types: one for Through variables (mass flow rate and heat flux), the other for
Across variables (pressure and temperature). By using the PS-Simulink Converter
block, you can specify the physical units of the sensed variable.

An alternative approach is to use Simscape data logging. This approach, which uses
MATLAB commands instead of blocks, provides access to a broader range of model
variables and parameters. One example is the kinematic viscosity of the liquid medium
inside a pipeline segment. You can analyze this parameter using Simscape data logging
but not sensor blocks.

For an overview of Simscape data logging, see “About Simulation Data Logging” on page
9-2. For an example of how to plot logged data, see “Log and Plot Simulation Data”
on page 9-8.

Run Simulation
The final step in the modeling workflow is to simulate the model. Before running
simulation, check that the numerical solver is appropriate for your model. To do this, use
the Model Configuration Parameters dialog box.

For physical models, variable-step solvers such as ode15s typically perform best. Reduce
step sizes and tolerances for greater simulation accuracy. Increase them instead for
faster simulation.

Run the simulation. Plot simulation data from sensors and Simscape data logging,
or process it for further analysis. If necessary, refine the model. For example, correct
simulation issues or to improve model fidelity.

Related Examples
• “Heat Transfer in Insulated Oil Pipeline” on page 2-14

More About
• “Thermal Liquid Library” on page 2-6
• “Thermal Liquid Modeling Framework” on page 2-10

2-5
2 Thermal Liquid Models

Thermal Liquid Library

In this section...
“Why Use Thermal Liquid Blocks?” on page 2-6
“Representing Thermal Liquid Components” on page 2-6
“Specifying Thermal Liquid Medium” on page 2-8
“Modeling Multidomain Systems” on page 2-8

Why Use Thermal Liquid Blocks?


The thermal behavior of liquid systems is of interest in many engineering applications.
Liquids can store energy and release it back to their surroundings, often doing work in
the process. Oil flow through an underground pipeline and hydraulic fluid flow in an
aircraft actuator are two examples.

When temperature fluctuations are negligible, liquids behave as isothermal fluids, which
simplifies the modeling process. However, when detailed thermal analysis is a goal, or
when temperature fluctuations are significant, this assumption is no longer suitable.

The Thermal Liquid library provides a modeling tool that you can use to analyze the
thermal behavior of thermal liquid systems. Three featured examples show some
applications well-suited for Thermal Liquid modeling:

• ssc_tl_oil_pipeline — Model oil temperature along an insulated underground


pipeline.
• ssc_tl_hydraulic_fluid_warming — Model hydraulic fluid warming due to
viscous dissipation inside a hydraulic actuator.
• ssc_tl_water_hammer — Model the water hammer effect due to a fast-turning
hydraulic valve.

Representing Thermal Liquid Components


Thermal liquid systems can range in complexity from basic to highly specialized. To
model a basic system, simple components often suffice. These are components such as
chambers, pipes, pumps, and the liquid medium itself. Simple components are often

2-6
Thermal Liquid Library

industry independent and can be modeled using a single Thermal Liquid block. For
example, you can model a pipeline segment using a single Pipe (TL) block.

To model a specialized system, generally you use custom components. These are
components that you cannot represent by a single Thermal Liquid block. The five-way
directional control valve in the ssc_tl_hydraulic_fluid_warming example is one
such component. Custom components are often industry specific and must be modeled by
grouping Thermal Liquid blocks into more complex subsystems.

The Thermal Liquid library shares the structure of other Simscape Foundation libraries.
Four sublibraries supply the Thermal Liquid blocks: Elements, Sources, Sensors, and
Utilities. With these sublibraries you can represent the most common components of a
thermal liquid system. The table summarizes these components.

Component Type Description Thermal Liquid Blocks


Liquid storage Store liquid in chambers or Constant Volume
reservoirs. Chamber (TL), Reservoir
(TL), Controlled
Reservoir (TL)
Liquid transport Transport thermal liquid Pipe (TL)
through closed conduits
such as pipes.
Flow restriction Restrict thermal liquid Local Restriction
flow, e.g., due to valves or (TL), Variable Local
fittings. Restriction (TL)
Mechanical interfaces Interface thermal liquid and Translational
mechanical systems, e.g., to Mechanical Converter
convert liquid mechanical (TL), Rotational
energy into useful work. Mechanical Converter
(TL)
Power sources Provide a power source to Mass Flow Rate Source
the thermal liquid system, (TL), Pressure Source
e.g. , pressure difference or (TL), Controlled Mass
mass flow rate. Flow Rate Source (TL),
Controlled Pressure
Source (TL)
Sensors Collect measurement data Pressure & Temperature
for analysis of parameters, Sensor (TL), Mass Flow

2-7
2 Thermal Liquid Models

Component Type Description Thermal Liquid Blocks


such as mass flow rate, Rate & Thermal Flux
thermal flux, pressure, and Sensor (TL)
temperature.
Thermal liquid Specify thermodynamic Thermal Liquid
properties and pressure- Settings (TL)
temperature validity region
of thermal liquid medium.

Specifying Thermal Liquid Medium


The Thermal Liquid Settings (TL) block specifies the thermodynamic properties of
the liquid medium. These properties are assumed functions of both pressure and
temperature. This assumption boosts model fidelity, especially in models in which
pressure, temperature, or both, vary widely.

The block accepts two-way lookup tables as input. These tables provide the different
thermodynamic property values at discrete pressures and temperatures. You can
populate these tables using empirical data from product data sheets or values calculated
from analytical expressions.

Modeling Multidomain Systems


Thermal Liquid blocks can contain different types of conserving ports. These ports
include not only Thermal Liquid conserving ports but also thermal and mechanical
conserving ports. By using these ports, you can interface a Thermal Liquid subsystem
with thermal and mechanical subsystems.

For instance, you can use the thermal conserving port of a Pipe (TL) block to model
conductive heat transfer through a pipe wall. Oil pipeline modeling is one application.
The example ssc_tl_oil_pipeline shows this approach.

Similarly, you can use the translational mechanical conserving ports of a Translational
Mechanical Converter (TL) block to convert hydraulic pressure in a thermal liquid
system into a mechanical actuation force. Hydraulic actuator modeling is one application.
The example ssc_tl_hydraulic_fluid_warming shows this approach.

The table lists the Thermal Liquid blocks that have thermal or mechanical conserving
ports. You can use these blocks to create a multidomain model containing thermal liquid,
thermal, and mechanical subsystems.

2-8
Thermal Liquid Library

Thermal Liquid Block Thermal Conserving Port Mechanical Conserving Port


Constant Volume Chamber ✓ ✗
(TL)
Pipe (TL) ✓ ✗
Rotational Mechanical ✓ ✓
Converter (TL)
Translational Mechanical ✓ ✓
Converter (TL)

Related Examples
• “Heat Transfer in Insulated Oil Pipeline” on page 2-14

More About
• “Modeling Thermal Liquid Systems” on page 2-2
• “Thermal Liquid Modeling Framework” on page 2-10

2-9
2 Thermal Liquid Models

Thermal Liquid Modeling Framework

In this section...
“How Blocks Represent Components” on page 2-10
“How Ports Represent Interfaces” on page 2-11
“Full Flux Scheme” on page 2-12

How Blocks Represent Components


Thermal Liquid models are based on the finite volume method. This method discretizes a
thermal liquid system into multiple control volumes that interact via shared interfaces.
An oil pipeline system is one example: you can model this system as a set of pipeline
segments that connect serially along the pipeline length.

Discretization of Pipeline System

A control volume can represent a thermal liquid component, such as an oil pipeline, or
a part of a component, such as a pipeline segment. You can discretize a thermal liquid
system and its components as finely as you need, for example to increase simulation
accuracy. However, the finer the discretization, the greater the model complexity—and
the slower the simulation.

Thermal Liquid blocks represent the control volume of a component using an internal
node. This node provides the liquid pressure and temperature inside the component. The
node is not visible, but you can access its parameters and variables using Simscape data
logging. For more information, see “About Simulation Data Logging” on page 9-2.

2-10
Thermal Liquid Modeling Framework

Simscape Nodes in Pipe (TL) Block

Two physical principles govern the dynamic evolution of liquid pressure and temperature
at the internal node of a control volume: mass conservation and energy conservation.
Pressure and temperature computation is carried out for the control volume surrounding
the internal node. This control volume is the total volume of the thermal liquid
component the block represents.

A second set of nodes represents the interfaces through which a finite volume can
interact with its neighbors. These nodes are visible as Simscape conserving ports,
of which Thermal Liquid conserving ports are the most important. By allowing the
exchange of mass, momentum, and energy between adjacent liquid volumes, Thermal
Liquid conserving ports govern the dynamic evolution of the finite volume as it tends to a
steady state.

How Ports Represent Interfaces


Thermal Liquid conserving ports provide the liquid pressure and temperature at the
interfaces they represent. They also provide the flow rates of mass and heat, which
govern the interactions between thermal liquid components. Pressure and temperature
are the Across variables of the Thermal Liquid domain, while the flow rates are the
Through variables.

Two physical principles govern the mass and heat flow rates through a Thermal Liquid
conserving port: momentum conservation and energy conservation. The mass flow rate
at a port is computed from the momentum conservation principle. The heat flow rate at a
port is computed from the thermal energy conservation principle.

2-11
2 Thermal Liquid Models

The flow rate computations are carried out for half the control volume of a thermal liquid
component. The half control volume is bounded on one end by the interface the port
represents, and on another end by a parallel surface passing through the control volume
centroid.

The figure shows the half control volume for flow rate computations at interface A of a
pipeline segment. Interface A corresponds to Thermal Liquid conserving port A of a Pipe
(TL) block. Node C corresponds to the internal node of the block, which is coincident with
the control volume centroid.

Half Control Volume for Flow Rate Calculations

Full Flux Scheme


Blocks in the Thermal Liquid library implement a full flux scheme. Using this scheme,
the net heat flux through a Thermal Liquid conserving port contains both convective
and conductive flux contributions. By including thermal conduction in the flow direction,
Thermal Liquid blocks provide more realistic simulation of the physical system they
represent.

Other advantages of the full flux scheme include enhanced simulation robustness of
thermal liquid models. This robustness becomes relevant in models where the conductive
flux contribution can be dominant. Examples include instances of low mass flow rates
and flow reversal, during which the convective flux becomes negligible or vanishes
altogether.

Related Examples
• “Heat Transfer in Insulated Oil Pipeline” on page 2-14

2-12
Thermal Liquid Modeling Framework

More About
• “Modeling Thermal Liquid Systems” on page 2-2
• “Thermal Liquid Library” on page 2-6

2-13
2 Thermal Liquid Models

Heat Transfer in Insulated Oil Pipeline


In this section...
“Oil Pipelines” on page 2-14
“Modeling Considerations” on page 2-15
“Simscape Model” on page 2-17
“Run Simulation” on page 2-18
“Run Optimization Script” on page 2-25

Oil Pipelines
Temperature plays an important role in oil pipeline design. Below the so-called cloud
point, paraffin waxes precipitate from crude oil and start to accumulate along the pipe
wall interior. The waxy deposits restrict oil flow, increasing the power requirements of
the pipeline. At still-lower temperatures—below the pour point of oil—these crystals
become so numerous that, if allowed to quiesce, oil becomes semisolid.

In cold climates, conductive heat losses through the pipe wall can be significant. To
keep oil in its favorable temperature range, pipelines include some temperature control
measures. Heating stations placed at intervals along the pipeline help to warm the oil.
An insulant liner covering the pipe wall interior helps to retard the cooling rate of the oil.

Viscous dissipation provides an additional heat source. As adjacent parcels of oil flow
against each other, they experience energy losses that appear in the form of heat. The
warming effect is small, but sufficient to at least partially offset the conductive heat
losses that occur through the insulant liner.

2-14
Heat Transfer in Insulated Oil Pipeline

At a certain insulation thickness, viscous dissipation exactly balances the conductive


heat loss. Oil stays at its ideal temperature throughout the pipeline length and the need
for heating stations is reduced. From a design standpoint, this insulation thickness is
optimal.

In this example, you simulate an insulated oil pipeline segment. You then run an
optimization script to determine the optimal insulation thickness. This example is based
on Simscape model ssc_tl_oil_pipeline.

Modeling Considerations
The physical system in this example is an oil pipeline segment. Insulation lines the pipe
wall interior, while soil covers the pipe wall exterior, retarding conductive heat loss. The
simplifying assumption is made that the physical system is symmetric about the pipe
center line.

Flow through the pipeline segment is assumed fully developed: the velocity profile of
the flowing oil remains constant along the pipeline length. In addition, oil is assumed
Newtonian and compressible: shear stress is proportional to the shear strain, and mass
density varies with both temperature and pressure.

Oil enters the pipeline segment at a fixed temperature, TUpstream, with a fixed mass
flow rate, Vdot * rho0, where:

• Vdot is the volumetric flow rate of oil through the pipe.

2-15
2 Thermal Liquid Models

• rho0 is the mass density of oil entering the pipeline segment.

Inside the pipeline segment, viscous dissipation heats the flowing oil, while thermal
conduction through the pipe wall cools it. The balance between the two processes governs
the temperature of oil exiting the pipeline segment.

The amount of heat gained through viscous dissipation depends partly on oil viscosity
and mass flow rate. The greater these quantities are, the greater the viscous heat gain
is—and the warmer the oil tends to get. The amount of heat lost via thermal conduction
depends partly on the thermal resistances of the insulation, pipe wall, and soil layer.
The smaller the thermal resistances are, the greater the conductive heat loss is—and the
cooler the oil tends to get.

Using an electrical circuit analogy, the combined thermal resistance of three material
layers arranged in series equals the sum of the individual thermal resistances:
Rcombined = Rwall + Rins. + Rsoil

Assuming the pipe wall is thin and its material a good thermal conductor, you can safely
ignore the thermal resistance of the pipe wall. The combined thermal resistance is then
simply the sum of the insulation and soil contributions, Rins. and Rsoil.

The thermal resistance of the insulation layer is directly proportional to its thickness,
(D2-D1)/2, and inversely proportional to its thermal conductivity, kInsulant. Likewise,
the thermal resistance of the soil layer is directly proportional to its thickness, z, and
inversely proportional to its thermal conductivity, kSoil.

The figure shows the relevant dimensions of the pipeline segment. Variable names match
those specified in the model. The inner insulation diameter, D1, is also the hydraulic
diameter of the pipeline segment.

2-16
Heat Transfer in Insulated Oil Pipeline

Simscape Model
The Simscape model ssc_tl_oil_pipeline represents an insulated oil pipeline
segment buried underground. To open this model, at the MATLAB command prompt,
enter ssc_tl_oil_pipeline. The figure shows the model.

2-17
2 Thermal Liquid Models

The Pipe (TL) block represents the physical system in this example, i.e., the oil pipeline
segment. Port A represents its inlet and port B its outlet. Port W represents thermal
conduction through the pipe wall. The block accounts for viscous heating.

The Mass Flow Rate Source (TL) block provides the flow rate through the pipe. The From
upstream segment block acts as a temperature source for the pipe inlet, while the To
downstream segment block acts as a temperature sink at the pipe outlet.

The Conduction through insulant and Conduction through soil blocks represent thermal
conduction through insulant and soil layers, respectively. These blocks appear in the
Simscape Thermal library as Conductive Heat Transfer. The Soil subsystem block
provides the temperature boundary condition at the soil surface.

The Thermal Liquid Settings (TL) block provides the physical properties of the
oil, expressed as two-sided lookup tables containing the temperature and pressure
dependence of the properties. The table summarizes these blocks.

Block Description
Pipe (TL) Pipeline segment
Conduction through insulant Insulant thermal conduction
Conduction through soil Soil thermal conduction
Soil (Subsystem) Soil temperature
From upstream segment Pipe inlet temperature sink
To downstream segment Pipe outlet temperature sink
Mass Flow Rate Source (TL) Oil mass flow rate
Thermal Liquid Settings (TL) Oil thermodynamic properties

Run Simulation
To analyze the performance of the oil pipeline segment, simulate the model. The
Comparison scope plots the upstream and downstream oil temperatures. Open this scope.
The insulation thickness is near its optimal value, resulting in only a small temperature
change over a 1000 meter length. At a rate of ~0.020 K/km, oil temperature changes
approximately 2 K over a 100 kilometer length.

2-18
Heat Transfer in Insulated Oil Pipeline

Plot Physical Properties Using Data Logging

By using Simscape data logging, you can plot the physical properties of the oil as a
function of simulation time. Such a plot clearly shows any variability in the value of a
physical property. One example is the kinematic viscosity of oil in the pipeline segment,
represented by the Pipe (TL) block.

1 At the MATLAB command line, enter simlog.Pipe_TL.print.

In the data tree, the kinematic viscosity nu appears under the node pipe_model,
which itself appears under the node simlog.Pipe_TL. The logging object for the
kinematic viscosity of oil in the pipe, then, is simlog.Pipe_TL.pipe_model.nu.

2-19
2 Thermal Liquid Models

2-20
Heat Transfer in Insulated Oil Pipeline

2 At the MATLAB command line, enter


simscape.logging.plot({simlog.Pipe_TL.pipe_model.nu}).

As expected, the kinematic viscosity remains approximately constant throughout the


simulation, reflecting the minimal temperature changes that occur in the oil.

Note: For more information about Simscape logging, see “About Simulation Data
Logging” on page 9-2.

Simulate Effects of Changing Insulation Diameter

Experiment with different values for the insulation inner diameter. By varying this
parameter, you offset the balance between viscous dissipation, which heats the oil, and
thermal conduction, which cools the oil.

1 Open Model Explorer.


2 In the Model Hierarchy pane, select Base Workspace.
3 In the Contents pane, click the value of parameter D1.
4 Enter 0.20.

2-21
2 Thermal Liquid Models

By reducing the inner diameter of the insulation layer to 0.20, you increase the
insulation thickness, slowing down heat loss through the pipe wall via thermal
conduction. Run the simulation. Then, open the Comparison scope and autoscale to view
full plot.

The new plot shows an oil temperature at the pipe outlet (top curve) that significantly
exceeds that at the pipe inlet (bottom line). Viscous dissipation now dominates the
thermal energy balance in the pipeline segment. The new insulation thickness poses a
design problem: in a long pipeline, a 1.1 K/km heating rate can raise the oil temperature
substantially at the receiving end of the pipeline.

Plotting the kinematic viscosity as a function of time shows that its variability is now
quite significant also. At the MATLAB command line, enter the logging command:
simscape.logging.plot({simlog.Pipe_TL.pipe_model.nu}).

2-22
Heat Transfer in Insulated Oil Pipeline

Try increasing the inner diameter of the insulation layer, D1, to 0.55. By increasing this
value, you decrease the insulation thickness, accelerating heat loss through the pipe
wall via thermal conduction. Then, run the simulation. Open the Comparison scope and
autoscale to view the full plot.

2-23
2 Thermal Liquid Models

The resulting plot shows that the oil temperature at the pipe outlet is now significantly
lower than that at the pipe inlet. Thermal conduction clearly dominates the thermal
energy balance in the pipeline segment. This insulation thickness also poses a
design issue: at a rate of 0.25K/km, oil flowing through a long pipeline will cool down
substantially.

Plot the kinematic viscosity as a function of time using Simscape logging. Because the
temperature change is now more modest, changes in viscosity are less significant.

2-24
Heat Transfer in Insulated Oil Pipeline

Run Optimization Script


The model provides an optimization script that you can run to determine the optimal
inner diameter of the pipe insulation, D1. The script iterates the model simulation
at different D1 values, plotting the rates of viscous warming and conductive cooling
against each other. The intersection point between the two curves identifies the optimal
insulation thickness for the model:

1 In the model window, double-click Run optimization script.

2-25
2 Thermal Liquid Models

2 In the plot that opens, visually determine the horizontal-axis value for the
intersection point between the two curves.

The optimal inner diameter of the insulation layer is 0.37 m. Update parameter D1 to
this value:

1 Open Model Explorer.


2 In the Model Hierarchy pane, click Base Workspace.
3 In the Contents pane, click the value of D1.
4 Enter 0.37.

Now, run the simulation. Open the Comparison scope and autoscale to view the full plot.
The temperature difference between the inlet and the outlet is negligible.

2-26
Heat Transfer in Insulated Oil Pipeline

More About
• “Modeling Thermal Liquid Systems” on page 2-2
• “Thermal Liquid Library” on page 2-6
• “Thermal Liquid Modeling Framework” on page 2-10

2-27
3

Two-Phase Fluid Models


3 Two-Phase Fluid Models

Manually Generate Fluid Property Tables

In this section...
“Fluid Property Tables” on page 3-2
“Steps for Generating Property Tables” on page 3-3
“Before Generating Property Tables” on page 3-3
“Create Fluid Property Functions” on page 3-3
“Set Property Table Criteria” on page 3-4
“Create Pressure-Normalized Internal Energy Grids” on page 3-5
“Map Grids Onto Pressure-Specific Internal Energy Space” on page 3-5
“Obtain Fluid Properties at Grid Points” on page 3-6
“Visualize Grids” on page 3-7

Fluid Property Tables


Fluid property tables provide the basic inputs to the Two-Phase Fluid Properties
(2P) block. If you have REFPROP software by the National Institute of Standards
and Technology installed, you can automatically generate these tables using the
twoPhaseFluidTable function. If you obtain the fluid properties from a different
source, such as CoolProp software, you can still generate the tables using a MATLAB
script. This tutorial shows how to create a script to generate the fluid temperature tables.

The tables must provide the fluid properties at discrete pressures and normalized
internal energies. The pressures must correspond to the table columns and the
normalized internal energies to the table rows. Setting pressure and normalized internal
energy as the independent variables enables you to specify the liquid and vapor phase
property tables on separate rectangular grids using MATLAB matrices.

The figure shows two fluid property grids in pressure-specific internal energy space (left)
and pressure-normalized internal energy space (right). If you obtain the fluid property
tables on a pressure-specific internal energy grid, you must transform that grid into its
pressure-normalized internal energy equivalent. In this tutorial, this transformation is
handled by the MATLAB script that you create.

3-2
Manually Generate Fluid Property Tables

Steps for Generating Property Tables


The MATLAB script that you create in this tutorial performs the following tasks:

• Define property table criteria, including dimensions and pressure-specific internal


energy domain.
• Create rectangular grids in pressure-normalized internal energy space.
• Map the grids onto pressure-specific internal energy space.
• Obtain the fluid properties on the pressure-specific internal energy grids.

Before Generating Property Tables


You must obtain fluid property data in pressure-specific internal energy space, e.g.,
through direct calculation, from a proprietary database, or from a third-party source. In
this tutorial, you create four MATLAB functions to provide example property data. In a
real application, you must replace these functions with equivalent functions written to
access real property data.

Create Fluid Property Functions


Create the following MATLAB functions. These functions provide the example property
data you use in this tutorial. Ensure that the function files are on the MATLAB path.
Use the function names and code shown:

• Name — liquidTemperature

function T = liquidTemperature(u, p)

3-3
3 Two-Phase Fluid Models

% Returns artificial temperature data as a function


% of specific internal energy and pressure.
T = 300 + 0.2*u - 0.08*p;
• Name — vaporTemperature
function T = liquidTemperature(u, p)
% Returns artificial temperature data as a function
% of specific internal energy and pressure.
T = 300 + 0.2*u - 0.08*p;
• Name — saturatedLiquidInternalEnergy
function u = saturatedLiquidInternalEnergy(p)
% Returns artificial data for saturated liquid specific
% internal energy as a function of pressure.
u = sqrt(p)*400 + 150;
• Name — saturatedVaporInternalEnergy
function u = saturatedVaporInternalEnergy(p)
% Returns artificial data for saturated vapor specific
% internal energy as a function of pressure.
u = -3*p.^2 + 40*p + 2500;

Set Property Table Criteria


Start a new MATLAB script. Save the script in the same folder as the MATLAB
functions you created to generate the example fluid property data. In the script, define
the criteria for the property tables. Do this by entering the following code for the table
dimensions and pressure-specific internal energy valid ranges:
% Number of rows in the liquid property tables
mLiquid = 25;
% Number of rows in the vapor property tables
mVapor = 25;
% Number of columns in the liquid and vapor property tables
n = 60;

% Minimum specific internal energy, kJ/kg


uMin = 30;
% Maximum specific internal energy, kJ/kg
uMax = 4000;
% Minimum pressure, MPa
pMin = 0.01;
% Maximum pressure, MPa

3-4
Manually Generate Fluid Property Tables

pMax = 15;

% Store minimum and maximum values in structure fluidTables


fluidTables.uMin = uMin;
fluidTables.uMax = uMax;
fluidTables.pMin = pMin;
fluidTables.pMax = pMax;

Create Pressure-Normalized Internal Energy Grids


Define the pressure and normalized internal energy vectors for the grid. These vectors
provide the discrete pressure and normalized internal energy values associated with each
grid point. The pressure vector is logarithmically spaced due to the wide pressure range
considered in this example. However, you can use any type of spacing that suits your
data. In your MATLAB script, add this code:

% Pressure vector, logarithmically spaced


fluidTables.p = logspace(log10(pMin), log10(pMax), n);

% Normalized internal energy vectors, linearly spaced


fluidTables.liquid.unorm = linspace(-1, 0, mLiquid)';
fluidTables.vapor.unorm = linspace(1, 2, mVapor)';

Map Grids Onto Pressure-Specific Internal Energy Space


Obtain the saturated liquid and vapor specific internal energies as functions of pressure.
The saturation internal energies enable you to map the normalized internal energy
vectors into equivalent vectors in specific internal energy space. In your MATLAB script,
add this code:

% Initialize the saturation internal energies of the liquid and vapor phases
fluidTables.liquid.u_sat = zeros(1, n);
fluidTables.vapor.u_sat = zeros(1, n);

% Obtain the saturation internal energies at the pressure vector values


for j = 1 : n
fluidTables.liquid.u_sat(j) = saturatedLiquidInternalEnergy(fluidTables.p(j));
fluidTables.vapor.u_sat(j) = saturatedVaporInternalEnergy(fluidTables.p(j));
end
This code calls two functions written to generate example data. Before using this code in
a real application, you must replace the functions with equivalent expressions capable of
accessing real data. The functions you must replace are:

3-5
3 Two-Phase Fluid Models

• saturatedLiquidInternalEnergy
• saturatedVaporInternalEnergy

Map the normalized internal energy vectors onto equivalent specific internal energy
vectors. In your MATLAB script, add this code:
% Map pressure-specific internal energy grid onto
% pressure-normalized internal energy space
fluidTables.liquid.u = (fluidTables.liquid.unorm + 1)*...
(fluidTables.liquid.u_sat - uMin) + uMin;
fluidTables.vapor.u = (fluidTables.vapor.unorm - 2)*...
(uMax - fluidTables.vapor.u_sat) + uMax;

Obtain Fluid Properties at Grid Points


You can now obtain the fluid properties at each grid point. The following code shows
how to generate the temperature tables for the liquid and vapor phases. Use a similar
approach to generate the remaining fluid property tables. In your MATLAB script, add
this code:
% Obtain temperature tables for the liquid and vapor phases
for j = 1 : n
for i = 1 : mLiquid
fluidTables.liquid.T(i,j) = ...
liquidTemperature(fluidTables.liquid.u(i,j), fluidTables.p(j));
end
for i = 1 : mVapor
fluidTables.vapor.T(i,j) = ...
vaporTemperature(fluidTables.vapor.u(i,j), fluidTables.p(j));
end
end

This code calls two functions written to generate example data. Before using this code in
a real application, you must replace the functions with equivalent expressions capable of
accessing real data. The functions you must replace are:

• liquidTemperature
• vaporTemperature

To view the temperature tables generated, first run the script. Then, at the MATLAB
command prompt, enter fluidTables. MATLAB lists the contents of the fluidTables
structure array.

3-6
Manually Generate Fluid Property Tables

fluidTables =

uMin: 30
uMax: 4000
pMin: 0.0100
pMax: 15
p: [1x20 double]
liquid: [1x1 struct]
vapor: [1x1 struct]

To list the property tables stored in the liquidsubstructure, at the MATLAB command
prompt enter fluidTables.liquid.
305.9992 305.9988 305.9983 305.9975 ...
309.5548 309.7430 309.9711 310.2475 ...
313.1103 313.4872 313.9440 314.4976 ...
316.6659 317.2314 317.9169 318.747 ...
...

Visualize Grids
To visualize the original grid in pressure-normalized internal energy space, at the
MATLAB command prompt enter this code:
% Define p and unorm matrices with the grid
% point coordinates
pLiquid = repmat(fluidTables.p, mLiquid, 1);
pVapor = repmat(fluidTables.p, mVapor, 1);

unormLiquid = repmat(fluidTables.liquid.unorm, 1, n);


unormVapor = repmat(fluidTables.vapor.unorm, 1, n);

% Plot grid
figure;
hold on;

plot(unormLiquid, pLiquid, 'b.');


plot(unormVapor, pVapor, 'b.');

plot(zeros(1, n), fluidTables.p, 'k-');


plot(ones(1, n), fluidTables.p, 'k-');

hold off;
set(gca, 'yscale', 'log');

3-7
3 Two-Phase Fluid Models

xlabel('Normalized Internal Energy');


ylabel('Pressure');
title('Grid in Normalized Internal Energy');

A figure opens with the pressure-normalized internal energy grid.

To visualize the transformed grid in pressure-specific internal energy space, at the


MATLAB command prompt enter this code:
% Define horizontal and vertical axes

% Plot grid
figure;
hold on;

plot(fluidTables.liquid.u, pLiquid, 'b.');


plot(fluidTables.vapor.u, pVapor, 'b.');

plot(fluidtables.liquid.u_sat, fluidTables.p, 'k-');


plot(fluidtables.vapor.u_sat, fluidTables.p, 'k-');

hold off;

3-8
Manually Generate Fluid Property Tables

set(gca, 'yscale', 'log');


xlabel('Specific Internal Energy');
ylabel('Pressure');
title('Grid in Specific Internal Energy');

A figure opens with the pressure-specific internal energy grid.

3-9
4

Model Simulation

• “How Simscape Models Represent Physical Systems” on page 4-2


• “How Simscape Simulation Works” on page 4-5
• “Setting Up Solvers for Physical Models” on page 4-11
• “Important Concepts and Choices in Physical Simulation” on page 4-17
• “Making Optimal Solver Choices for Physical Simulation” on page 4-21
• “Troubleshooting Simulation Errors” on page 4-26
• “Limitations” on page 4-32
• “References” on page 4-37
4 Model Simulation

How Simscape Models Represent Physical Systems


In this section...
“Representations of Physical Systems” on page 4-2
“Differential, Differential-Algebraic, and Algebraic Systems” on page 4-2
“Stiffness” on page 4-3
“Events and Zero Crossings” on page 4-3
“Working with Simscape Representation” on page 4-3

Representations of Physical Systems


This section describes important characteristics of the mathematical representations
of physical systems, and how Simscape software implements such representations. You
might find this overview helpful if you:

• Require details of such representations to improve your model fidelity or simulation


performance.
• Are constructing your Simscape model or its components with the Simscape language.
• Need to troubleshoot Simscape modeling or simulation failures.

Mathematical representations are the foundation for physical simulation. For more
information about simulation, see “How Simscape Simulation Works” on page 4-5.

Differential, Differential-Algebraic, and Algebraic Systems


The mathematical representation of a physical system contains ordinary differential
equations (ODEs), algebraic equations, or both.

• ODEs govern the rates of change of system variables and contain some or all of the
time derivatives of the system variables.
• Algebraic equations specify functional constraints among system variables, but
contain no time derivatives of system variables.

• Without algebraic constraints, the system is differential (ODEs).


• Without ODEs, the system is algebraic.
• With ODEs and algebraic constraints, the system is mixed differential-algebraic
(DAEs).

4-2
How Simscape Models Represent Physical Systems

A system variable is differential or algebraic, depending on whether or not its time


derivative appears in the system equations.

Stiffness
A mathematical problem is stiff if the solution you are seeking varies slowly, but there
are other solutions within the error tolerances that vary rapidly. A stiff system has
several intrinsic time scales of very different magnitude [1].

A stiff physical system has one or more components that behave “stiffly” in the ordinary
sense, such as a spring with a large spring constant. Mathematical equivalents include
quasi-incompressible fluids and low electrical inductance. Such systems often exhibit
high frequency oscillations in some of their components or modes.

Events and Zero Crossings


Events are discontinuous changes in system state or dynamics as the system evolves in
time; for example, a valve opening, or a hard stop.

A zero crossing is a specific event type, represented by the value of a mathematical


function changing sign.

Working with Simscape Representation


A Simscape model is equivalent to a set of equations representing one or more physical
systems as physical networks.

• Start by assuming that your physical network is a DAE system: “Differential,


Differential-Algebraic, and Algebraic Systems” on page 4-2.

Remember that some physical networks are represented by ODEs only.


• Physical networks may contain “Stiffness” on page 4-3.
• Identify discrete and continuous components that might “Events and Zero Crossings”
on page 4-3 during a simulation.

Creating and Detecting Zero Crossings in Simscape Models

Simulink and Simscape software have specific methods for detecting and locating zero-
crossing events. For general information, see “Zero-Crossing Detection” in the Simulink
documentation.

4-3
4 Model Simulation

Your model can contain zero-crossing conditions arising from several sources:

• Simscape and normal Simulink blocks copied from their respective block libraries
• Expressions programmed in the Simscape language

You can disable zero-crossing detection on individual blocks, or globally across the
entire model. Zero-crossing detection often improves simulation accuracy, but can slow
simulation speed.

Tip If the exact times of zero crossings are important in your model, then keep zero-
crossing detection enabled. Disabling it can lead to major simulation inaccuracies.

Enabling and Disabling Zero-Crossing Conditions in Simscape Language

In the Simscape language, you can create or avoid Simulink zero-crossing conditions in
your model by switching between different implementations of discontinuous conditional
expressions. You can:

• Use relational operators, which create zero-crossing conditions. For example,


programming the operator relation: a < b creates a zero-crossing condition.
• Use relational functions, which do not create zero-crossing conditions. For example,
programming the functional relation: lt(a,b) does not create a zero-crossing
condition.

4-4
How Simscape Simulation Works

How Simscape Simulation Works

In this section...
“Simscape Simulation Phases” on page 4-5
“Model Validation” on page 4-7
“Network Construction” on page 4-7
“Equation Construction” on page 4-8
“Initial Conditions Computation” on page 4-8
“Transient Initialization” on page 4-9
“Transient Solve” on page 4-10

Simscape Simulation Phases


You might find this brief overview helpful for constructing models and understanding
errors. For more information, see “How Simscape Models Represent Physical Systems” on
page 4-2.

Simscape software gives you multiple ways to simulate and analyze physical systems
in the Simulink environment. Running a physical model simulation is similar to
simulating any Simulink model. It entails setting various simulation options, starting
the simulation, and viewing the simulation results. This topic describes various aspects
of simulation specific to Simscape models. For specifics of simulating and analyzing with
individual Simscape add-on products, refer to the documentation for those individual
add-on products.

This flow chart presents the Simscape simulation sequence.

4-5
4 Model Simulation

The flow chart consists of the following major phases:

1 “Model Validation” on page 4-7


2 “Network Construction” on page 4-7
3 “Equation Construction” on page 4-8
4 “Initial Conditions Computation” on page 4-8
5 “Transient Initialization” on page 4-9

4-6
How Simscape Simulation Works

6 “Transient Solve” on page 4-10

Model Validation
The Simscape solver first validates the model configuration and checks your data entries
from the block dialog boxes.

• All Simscape blocks in a diagram must be connected into one or more physical
networks. Unconnected Conserving ports are not allowed.
• Each topologically distinct physical network in a diagram requires exactly one Solver
Configuration block.
• If your model contains hydraulic elements, each topologically distinct hydraulic
circuit in a diagram must connect to a Custom Hydraulic Fluid block (or Hydraulic
Fluid block, available with SimHydraulics block libraries). These blocks define the
fluid properties that act as global parameters for all the blocks that connect to the
hydraulic circuit. If no hydraulic fluid block is attached to a loop, the hydraulic blocks
in this loop use the default fluid. However, more than one hydraulic fluid block in a
loop generates an error.

Similarly, if your model contains pneumatic elements, default gas properties for
a pneumatic network are for dry air and ambient conditions of 101325 Pa and 20
degrees Celsius. If you attach a Gas Properties block to a pneumatic circuit, you can
change gas properties and ambient conditions for all the blocks connected to the
circuit. However, more than one Gas Properties block in a pneumatic circuit generates
an error.
• Signal units specified in a Simulink-PS Converter block must match the input type
expected by the Simscape block connected to it. For example, when you provide the
input signal for an Ideal Angular Velocity Source block, specify angular velocity
units, such as rad/s or rpm, in the Simulink-PS Converter block, or leave it unitless.
Similarly, units specified in a PS-Simulink Converter block must match the type of
physical signal provided by the Simscape block outport.

Network Construction
After validating the model, the Simscape solver constructs the physical network based on
the following principles:

• Two directly connected Conserving ports have the same values for all their Across
variables (such as voltage or angular velocity).

4-7
4 Model Simulation

• Any Through variable (such as current or torque) transferred along the Physical
connection line is divided among the multiple components connected by the branches.
For each Through variable, the sum of all its values flowing into a branch point equals
the sum of all its values flowing out.

Equation Construction
Based on the network configuration, the parameter values in the block dialog boxes, and
the global parameters defined by the fluid properties, if applicable, the Simscape solver
constructs the system of equations for the model.

These equations contain system variables of the following types:

• Dynamic — Time derivatives of these variables appear in equations. Dynamic, or


differential, variables add dynamics to the system and require the solver to use
numerical integration to compute their values. Dynamic variables can produce either
independent or dependent states for simulation.
• Algebraic — Time derivatives of these variables do not appear in equations. These
variables appear in algebraic equations but add no dynamics, and this typically
occurs in physical systems due to conservation laws, such as conservation of mass and
energy. The states of algebraic variables are always dependent on dynamic variables,
other algebraic variables, or inputs.

The solver then performs the analysis and eliminates variables that are not needed
to solve the system of equations. After variable elimination, the remaining variables
(algebraic, dynamic dependent, and dynamic independent) get mapped to Simulink state
vector of the model.

For information on how to view and analyze model variables, see “Model Statistics”.

Initial Conditions Computation


The Simscape solver computes the initial conditions only once, at the beginning of
simulation (t = 0). In the Solver Configuration block dialog box, the default is that the
Start simulation from steady state check box is not selected. If it is selected in your
model, see “Finding an Initial Steady State” on page 4-9.

The solver computes the initial conditions by finding initial values for all the system
variables that exactly satisfy all the model equations. You can affect the initial conditions

4-8
How Simscape Simulation Works

computation by block-level variable initialization, that is, by specifying the priority and
target initial values on the Variables tab of the block dialog boxes.

The values you specify during block-level variable initialization are not the actual values
of the respective variables, but rather their target values at the beginning of simulation
(t = 0). Depending on the results of the solve, some of these targets may or may not be
satisfied. The solver tries to satisfy the high-priority targets first, then the low-priority
ones:

• At first, the solver tries to find a solution where all the high-priority variable
targets are met exactly, and the low-priority targets are approximated as closely as
possible. If the solution is found during this stage, it satisfies all the high-priority
targets. Some of the low-priority targets might also be met exactly, the others are
approximated.
• If the solver cannot find a solution that exactly satisfies all the high-priority targets,
it issues a warning and enters the second stage, where High priority is relaxed
to Low. That is, the solver tries to find a solution by approximating both the high-
priority and the low-priority targets as closely as possible.

After you initialize the block variables and prior to simulating the model, you can open
the Variable Viewer to see which of the variable targets have been satisfied. For more
information on block-level variable initialization, see “Variable Initialization”.

Finding an Initial Steady State

When you select the Start simulation from steady state check box, the solver
attempts to find the steady state that would result if the inputs to the system were held
constant for a long enough time, starting from the initial state obtained from the initial
conditions computation just described. If the steady-state solve succeeds, the state found
is some steady state (within tolerance), but not necessarily the state expected from the
given initial conditions. Steady state means that the system variables are no longer
changing with time. Simulation then starts from this steady state.

A model can have more than one steady state. In this case, the solver selects the steady-
state solution that is consistent with the variable targets specified during block-level
variable initialization. For more information, see “Variable Initialization”.

Transient Initialization
After computing the initial conditions, or after a subsequent event (such as a
discontinuity resulting, for example, from a valve opening, or from a hard stop), the

4-9
4 Model Simulation

Simscape solver performs transient initialization. Transient initialization fixes all


dynamic variables and solves for algebraic variables and derivatives of dynamic
variables. The goal of transient initialization is to provide a consistent set of initial
conditions for the next phase, transient solve.

Transient Solve
Finally, the Simscape solver performs transient solve of the system of equations. In
transient solve, continuous differential equations are integrated in time to compute all
the variables as a function of time.

The solver continues to perform the simulation according to the results of the transient
solve until the solver encounters an event, such as a zero crossing or discontinuity. The
event may be within the physical network or elsewhere in the Simulink model. If the
solver encounters an event, the solver returns to the phase of transient initialization, and
then back to transient solve. This cycle continues until the end of simulation.

4-10
Setting Up Solvers for Physical Models

Setting Up Solvers for Physical Models


In this section...
“About Simulink and Simscape Solvers” on page 4-11
“Choosing Simulink and Simscape Solvers” on page 4-11
“Harmonizing Simulink and Simscape Solvers” on page 4-13

About Simulink and Simscape Solvers


This section explains how to select solvers for physical simulation. Proper simulation
of Simscape models requires certain changes to Simulink defaults and consideration of
physical simulation trade-offs. For recommended choices, see “Making Optimal Solver
Choices for Physical Simulation” on page 4-21.

Choosing Simulink and Simscape Solvers


Simulink and Simscape solver technologies provide a range of tools to simulate physical
systems, including the powerful Simscape technique of local solvers. You choose global,
or model-wide, solvers through Simulink. After making these choices, check that they are
consistent; see “Harmonizing Simulink and Simscape Solvers” on page 4-13.

• “Working with Global Simulink Solvers” on page 4-11


• “Working with Local Simscape Solvers” on page 4-12

Working with Global Simulink Solvers

In the Configuration Parameters dialog box of your model, on the Solver pane, the
solver and related settings that you select are global choices. For more information, see
“Solvers” in the Simulink documentation.

When you first create a model, the default Simulink solver is ode45. To select a different
solver, follow a procedure similar to the procedure in “Modifying Initial Settings” on page
1-26.

• You can choose one from a suite of both variable-step and fixed-step solvers. A
variable-step solver is the default.
• You can also select from among explicit and implicit solvers. An explicit solver is the
default. But for physical models, MathWorks recommends implicit solvers, such as

4-11
4 Model Simulation

ode14x, ode23t, and ode15s. Implicit solvers require fewer time steps than explicit
solvers, such as ode45, ode113, and ode1.

See “Switching from the Default Explicit Solver to Other Simulink Solvers” on page
4-14.
• If all the Simulink and Simscape states in your model are discrete, Simulink
automatically switches to a discrete solver and issues a warning. Otherwise, a
continuous solver is the default.
• By default, Simulink variable-step solvers attempt to locate events in time by zero-
crossing detection. See “Enabling or Disabling Simulink Zero-Crossing Detection” on
page 4-16.

Working with Local Simscape Solvers

You can switch one or more physical networks to a local implicit, fixed-step Simscape
solver by selecting Use local solver in the network Solver Configuration block. The
solver and related settings you make in each Solver Configuration block are specific to
the connected physical network and can differ from network to network.

A physical network using a local solver appears to the global Simulink solver as if it has
discrete states. You can still use any continuous global solver.
Choosing Local Solvers and Sample Times

To use a local solver, choose a solver type (Backward Euler or Trapezoidal Rule) and a
sample time. Backward Euler is the default.
Choosing Fixed-Cost Simulation

You can select a fixed-cost simulation for one or more physical networks by selecting Use
fixed-cost runtime consistency iterations, as well as Use local solver, and fixing
the number of nonlinear and mode iterations. Fixed-cost simulation requires a global
fixed-step solver.
Choosing Multirate Simulation

With the local solver option, you can perform multirate simulations, with:

• Different sample times in different physical networks, through their respective Solver
Configuration blocks
• A sample-based Simulink block in the model with a sample time different from the
Solver Configuration block or blocks

4-12
Setting Up Solvers for Physical Models

Harmonizing Simulink and Simscape Solvers


Your Simulink and Simscape solver choices must work together consistently. To ensure
consistency of your Simulink and Simscape solver choices for a particular model, open
the model Configuration Parameters dialog box. From the top menu bar in the model
window, select Simulation > Model Configuration Parameters. Review and adjust
the following settings.

• “Switching from the Default Explicit Solver to Other Simulink Solvers” on page
4-14
• “Filtering Input Signals and Providing Time Derivatives” on page 4-14
• “Enabling or Disabling Simulink Zero-Crossing Detection” on page 4-16
• “Making Multirate Simulation Consistent” on page 4-16

Simscape Pane of the Configuration Parameters Dialog Box

4-13
4 Model Simulation

Switching from the Default Explicit Solver to Other Simulink Solvers

If you do not modify the default (explicit) solver, your performance may not be optimal.
Implicit solvers are better for most physical simulations. For more information about
implicit solvers and physical systems, see “Important Concepts and Choices in Physical
Simulation” on page 4-17.
Diagnostic Messages About Explicit Solvers

When you use an explicit solver in a model containing Simscape blocks, the system issues
a warning to alert you to a potential problem.

To turn off this default warning or to change it to an error message, go to the Simscape
pane of the Configuration Parameters dialog box:

1 From the Explicit solver used in model containing Physical Networks blocks
drop-down list, select the option that you want:

• warning — If the model uses an explicit solver, the system issues a warning
upon simulation. This is the default option that alerts you to a potential problem
if you use the default solver.
• error — If the model uses an explicit solver, the system issues an error message
upon simulation. If your model is stiff, and you do not want to use explicit solvers,
select this option to avoid future errors.
• none — If the model uses an explicit solver, the system issues no warning or
error message upon simulation. If you want to work with explicit solvers, in
particular for models that are not stiff, select this option.
2 Click OK.

Filtering Input Signals and Providing Time Derivatives

You may need to provide time derivatives of some of the input signals, especially if you
use an explicit solver. One way of providing the necessary input derivatives is by filtering
the input through a low-pass filter. Input filtering makes the input signal smoother
and generally improves model performance. The additional benefit is that the Simscape
engine computes the time derivatives of the filtered input. The first-order filter provides
one derivative, while the second-order filter provides the first and second derivatives. If
you use input filtering, it is very important to select the appropriate value for the filter
time constant.

The filter time constant controls the filtering of the input signal. The filtered input
follows the true input but is smoothed, with a lag on the order of the time constant that

4-14
Setting Up Solvers for Physical Models

you choose. Set the time constant to a value no larger than the smallest time interval in
the system that interests you. If you choose a very small time constant, the filtered input
signal is closer to the true input signal. However, this filtered input signal increases the
stiffness of the system and slows the simulation.

Instead of using input filtering, you can provide time derivatives for the input signal
directly, as additional physical signals.

You can control the way you provide time derivatives for each input signal by configuring
the Simulink-PS Converter block connected to that input signal:

1 Open the Simulink-PS Converter block dialog box.


2 Click the Input handling tab.

3 To turn on input filtering, set the Filtering and derivatives parameter to


Filter input. Select the first-order or second-order filter, by using the Input
filtering order parameter, and set the appropriate Input filtering time constant
parameter value for your model.
4 To avoid filtering the input signal, set the Filtering and derivatives parameter
to Provide input derivative(s). Then set the Input derivatives parameter
value:

4-15
4 Model Simulation

• Provide first derivative — If you select this option, an additional


Simulink input port appears on the Simulink-PS Converter block, to let you
connect the signal providing input derivatives.
• Provide first and second derivatives — If you select this option, two
additional Simulink input ports appear on the Simulink-PS Converter block, to
let you connect the signals providing input derivatives.

Enabling or Disabling Simulink Zero-Crossing Detection

By default, Simulink tracks an important class of simulation events by detecting zero


crossings. With a global variable-step solver and without a local solver, Simulink
attempts to locate the simulated times of zero crossings, if present. See “Working with
Simscape Representation” on page 4-3.
Diagnostic Messages About Globally Disabling Zero-Crossing Detection

You can globally disable zero-crossing detection in the Solver pane of the Configuration
Parameters dialog box, under Zero-crossing options. If you do, and if you are using a
global variable-step solver without a local solver, the system issues a warning or error
when you simulate with Simscape blocks.

You can choose between warning and error messages in the Simscape pane of the
Configuration Parameters dialog box.

1 From the Zero-crossing control is globally disabled in Simulink drop-down


list, select the option that you want, if you globally disable zero-crossing detection:

• warning — The system issues a warning message upon simulation. This option
is the default.
• error — The system issues an error message upon simulation, which stops.
2 Click OK.

Making Multirate Simulation Consistent

The sample time or step size of the global Simulink solver must be the smallest time step
of all the solvers in a multirate Simscape simulation.

To avoid simulation errors in sample time propagation, go to the Solver pane in the
Configuration Parameters dialog box and select the Automatically handle rate
transition for data transfer check box.

4-16
Important Concepts and Choices in Physical Simulation

Important Concepts and Choices in Physical Simulation


This section describes advanced concepts and trade-offs you might want to consider
as you configure and test solvers and other simulation settings for your Simscape
model. For a summary of recommended settings, see “Making Optimal Solver Choices
for Physical Simulation” on page 4-21. For background information, consult “How
Simscape Models Represent Physical Systems” on page 4-2 and “How Simscape
Simulation Works” on page 4-5.

In this section...
“Variable-Step and Fixed-Step Solvers” on page 4-17
“Explicit and Implicit Solvers” on page 4-18
“Full and Sparse Linear Algebra” on page 4-18
“Event Detection and Location” on page 4-18
“Unbounded, Bounded, and Fixed-Cost Simulation” on page 4-19
“Global and Local Solvers” on page 4-19

Variable-Step and Fixed-Step Solvers


Variable-step solvers are the usual choice for design, prototyping, and exploratory
simulation, and to precisely locate events during simulation. They are not useful for real-
time simulation and can be costly if there are many events.

A variable-step solver automatically adjusts its step size as it moves forward in time to
adapt to how well it controls solution error. You control the accuracy and speed of the
variable-step solution by adjusting the solver tolerance. With many variable-step solvers,
you can also limit the minimum and maximum time step size.

Fixed-step solvers are recommended or required if you want to make performance


comparisons across platforms and operating systems, to generate a code version of your
model, and to bound or fix simulation cost. A typical application is real-time simulation.
For more information, see “Real-Time Simulation”.

With a fixed-step solver, you specify the time step size to control the accuracy and speed
of your simulation. Fixed-step solvers do not adapt to improve accuracy or to locate
events. These limitations can lead to significant simulation inaccuracies.

4-17
4 Model Simulation

Explicit and Implicit Solvers


The degree of stiffness and the presence of algebraic constraints in your model influence
the choice between an explicit or implicit solver. Explicit and implicit solvers use
different numerical methods to simulate a system.

• If the system is a nonstiff ODE system, choose an explicit solver. Explicit solvers
require less computational effort than implicit solvers, if other simulation
characteristics are fixed.

To find a solution for each time step, an explicit solver uses a formula based on the
local gradient of the ODE system.
• If the system is stiff, use an implicit solver. Though an explicit solver may require less
computational effort, for stiff problems an implicit solver is more accurate and often
essential to obtain a solution. Implicit solvers require per-step iterations within the
simulated time steps. With some implicit solvers, you can limit or fix these iterations.

An implicit solver starts with the solution at the current step and iteratively solves for
the solution at the next time step with an algebraic solver. An implicit algorithm does
more work per simulation step, but can take fewer, larger steps.
• If the system contains DAEs, even if it is not stiff, use an implicit solver. Such solvers
are designed to simultaneously solve algebraic constraints and integrate differential
equations.

Full and Sparse Linear Algebra


When you simulate a system with more than one state, the solver manipulates the
mathematical system with matrices. For a large number of states, sparse linear algebra
methods applied to large matrices can make the simulation more efficient.

Event Detection and Location


Events, in most cases, occur between simulated time steps.

• Fixed-step solvers detect events after “stepping over” them, but cannot adaptively
locate events in time. This can lead to large inaccuracies or failure to converge on a
solution.
• Variable-step solvers can both detect events and estimate the instants when they
occur by adapting the timing and length of the time steps.

4-18
Important Concepts and Choices in Physical Simulation

Tip To estimate the timing of events or rapid changes in your simulation, use a variable-
step solver.

If your simulation has to frequently adapt to events or rapid changes by changing its step
size, much or all of the advantage of implicit solvers over explicit solvers is lost.

Unbounded, Bounded, and Fixed-Cost Simulation


In certain cases, such as real-time simulation, you need to simulate with an execution
time that is not only bounded, but practically fixed to a predictable value. Fixing
execution time can also improve performance when simulating frequent events.

The real-time cost of a variable-step simulation is potentially unlimited. The solver


can take an indefinite amount of real time to solve a system over a finite simulated
time, because the number and size of the time steps are adapted to the system. You
can configure a fixed-step solver to take a bounded amount of real time to complete a
simulation, although the exact amount of real time might still be difficult to predict
before simulation. Even a fixed-step solver can take multiple iterations to find a solution
at each time step. Such iterations are variable and not generally limited in number; the
solver iterates as much as it needs to.

Fixing execution time implies fixed-cost simulation, which both fixes the time step
and limits the number of per-step iterations. Fixed-cost simulation prevents execution
overruns, when the execution time is longer than the simulation sample time. A bounded
execution time without a known fixed cost might still cause some steps to overrun the
sample time.

The actual amount of computational effort required by a solver is based on a number


of other factors as well, including model complexity and computer processor. For more
information, see “Real-Time Simulation”.

Global and Local Solvers


You can use different solvers on different parts of the system. For example, you might
want to use implicit solvers on stiff parts of a system and explicit solvers everywhere
else. Such local solvers make the simulation more efficient and reduce computational
cost.

4-19
4 Model Simulation

Such multisolver simulations must coordinate the separate sequences of time steps of
each solver and each subsystem so that the various solvers can pass simulation updates
to one another on some or all of the shared time steps.

4-20
Making Optimal Solver Choices for Physical Simulation

Making Optimal Solver Choices for Physical Simulation


For the key simulation concepts to consider before making these choices, see “Important
Concepts and Choices in Physical Simulation” on page 4-17.

In this section...
“Simulating with Variable Time Step” on page 4-21
“Simulating with Fixed Time Step — Local and Global Fixed-Step Solvers” on page
4-21
“Simulating with Fixed Cost” on page 4-22
“Troubleshooting and Improving Solver Performance” on page 4-23
“Multiple Local Solvers Example with a Mixed Stiff-Nonstiff System” on page 4-24

Simulating with Variable Time Step


For a typical Simscape model, MathWorks recommends the Simulink variable-step
solvers ode15s and ode23t. Of these two global solvers:

• The ode15s solver is more stable, but tends to damp out oscillations.
• The ode23t solver captures oscillations better but is less stable.

With Simscape models, these solvers solve the differential and algebraic parts of the
physical model simultaneously, making the simulation more accurate and efficient.

Simulating with Fixed Time Step — Local and Global Fixed-Step Solvers
In a Simscape model, MathWorks recommends that you implement fixed-step
solvers by continuing to use a global variable-step solver and switching the physical
networks within your model to local fixed-step solvers through each network Solver
Configuration block. The local solver choices are Backward Euler and Trapezoidal
Rule. Of these two local solvers:

• The Backward Euler tends to damp out oscillations, but is more stable, especially if
you increase the time step.
• The Trapezoidal Rule solver captures oscillations better but is less stable.

4-21
4 Model Simulation

Regardless of which local solver you choose, the Backward Euler method is always
applied:

• Right at the start of simulation.


• Right after an instantaneous change, when the corresponding block undergoes an
internal discrete change. Such changes include clutches locking and unlocking, valve
actuators opening and closing, and the switching of the Asynchronous Sample &
Hold block.

Switching to Discrete States and Solvers

• If you switch a physical network to a local solver, the global solver treats that network
as having discrete states.
• If other physical networks in your model are not using local solvers, or if the non-
Simscape parts of your model have continuous states, then you must use a continuous
global solver.
• If all physical networks in your model use local solvers, and any non-Simscape parts
of your model have only discrete states, then the global solver effectively sees only
discrete states. In that case, MathWorks recommends a discrete, fixed-step global
solver. If you are attempting a fixed-cost simulation with discrete states, you must use
a discrete, fixed-step global solver.

For Maximum Accuracy with Fixed-Step Simulation

If solution accuracy is your single overriding requirement, use the global Simulink fixed-
step solver ode14x, without local solvers. This implicit solver is the best global fixed-step
choice for physical systems. While it is more accurate than the Simscape local solvers for
most models, ode14x can be computationally more intensive and slower when you use it
by itself than it is when you use it in combination with local solvers.

In this solver, you must limit the number of global implicit iterations per time step.
Control these iterations with the Number Newton’s iterations parameter in the
Solver pane of the Configuration Parameters dialog box.

Simulating with Fixed Cost


Many Simscape models need to iterate multiple times within one time step to find
a solution. If you want to fix the cost of simulation per time step, you must limit the
number of these iterations, regardless of whether you are using a local solver, or a global

4-22
Making Optimal Solver Choices for Physical Simulation

solver like ode14x. For more information, see “Unbounded, Bounded, and Fixed-Cost
Simulation” on page 4-19 and “Fixed-Cost Simulation for Real-Time Viability” on page
7-55.

To limit the iterations, open the Solver Configuration block of each physical network.
Select Use fixed-cost runtime consistency iterations and set limits for the number
of nonlinear and mode iterations per time step.

Tip Fixed-cost simulation with variable-step solvers is not possible in most simulations.
Attempt fixed-cost simulation with a fixed-step solver only and avoid using fixed-cost
iterations with variable-step solvers.

Troubleshooting and Improving Solver Performance


Consider the basic trade-off of speed versus accuracy and stability. A larger time step or
tolerance results in faster simulation, but also less accurate and less stable simulation.
If a system undergoes sudden or rapid changes, larger tolerance or step size can cause
major errors. Consider tightening the tolerance or step size if your simulation:

• Is not accurate enough or looks unphysical.


• Exhibits discontinuities in state values.
• Reaches the minimum step size allowed without converging, usually a sign that one or
more events or rapid changes occur within a time step.

Any one or all of these steps increase accuracy, but make the simulation run more slowly.

For Local Solvers

Models with friction or hard stops are particularly difficult for local solvers, and may not
work or may require a very small time step.

With the Trapezoidal Rule solver, oscillatory “ringing” can become more of a problem as
the time step is increased. For a larger time step in a local solver, consider switching to
Backward Euler.

For ODE Systems

In certain cases, your model reduces to an ODE system, with no dependent algebraic
variables. (See “How Simscape Models Represent Physical Systems” on page 4-2.) If so,

4-23
4 Model Simulation

you can use any global Simulink solver, with no special physical modeling considerations.
An explicit solver is often the best choice in such situations.

• Through careful analysis, you can sometimes determine if your model is represented
by an ODE system.
• If you create a Simscape model from a mathematical representation using the
Simscape language, you can determine directly if the resulting system is ODE.

For Large Systems

Depending on the number of system states, you can simulate more efficiently if you
switch the value of the Linear Algebra setting in the Solver Configuration block.

For smaller systems, Full provides faster results. For larger systems, Sparse is
typically faster.

Multiple Local Solvers Example with a Mixed Stiff-Nonstiff System


In this example, a Simscape model contains three physical networks.

• Two networks (numbers 1 and 3) use local solvers, making these two networks appear
to the global solver as if they had discrete states. Internally, these networks still have
continuous states. These networks are moderately and highly stiff, respectively.

One of these networks (number 1) uses the Backward Euler (BE) local solver. The
other (number 3) uses the Trapezoidal Rule (TR) local solver.
• The remaining network (number 2) uses the global Simulink solver. Its states appear
to the model as continuous. This network is not stiff and is pure ODE. Use an explicit
global solver.
• Because at least one network appears to the model as continuous, you must use a
continuous solver. However, if you remove network 2, and if the model contains no
continuous Simulink states, Simulink automatically switches to a discrete global
solver.

4-24
Making Optimal Solver Choices for Physical Simulation

4-25
4 Model Simulation

Troubleshooting Simulation Errors


In this section...
“Troubleshooting Tips and Techniques” on page 4-26
“System Configuration Errors” on page 4-27
“Numerical Simulation Issues” on page 4-29
“Initial Conditions Solve Failure” on page 4-30
“Transient Simulation Issues” on page 4-30

Troubleshooting Tips and Techniques


Simscape simulations can stop before completion with one or more error messages. This
section discusses generic error types and error-fixing strategies. You might find the
previous section, “How Simscape Simulation Works” on page 4-5, useful for identifying
and tracing errors.

If a simulation failed:

• Review the model configuration. If your error message contains a list of blocks, look at
these blocks first. Also look for:

• Wrong connections — Verify that the model makes sense as a physical system. For
example, look for actuators connected against each other, so that they try to move
in opposite directions, or incorrect connections to reference nodes that prevent
movement. In electrical circuits, verify polarity and connections to ground.
• Wrong units — Simscape unit manager offers great flexibility in using physical
units. However, you must exercise care in specifying the correct units, especially in
the Simulink-PS Converter and PS-Simulink Converter blocks. Start analyzing the
circuit by opening all the converter blocks and checking the correctness of specified
units.
• Try to simplify the circuit. Unnecessary circuit complexity is the most common cause
of simulation errors.
• Break the system into subsystems and test every unit until you are positive that the
unit behaves as expected.
• Build the system by gradually increasing its complexity.

MathWorks recommends that you build, simulate, and test your model incrementally.
Start with an idealized, simplified model of your system, simulate it, verify that it works

4-26
Troubleshooting Simulation Errors

the way you expected. Then incrementally make your model more realistic, factoring in
effects such as friction loss, motor shaft compliance, hard stops, and the other things that
describe real-world phenomena. Simulate and test your model at every incremental step.
Use subsystems to capture the model hierarchy, and simulate and test your subsystems
separately before testing the whole model configuration. This approach helps you keep
your models well organized and makes it easier to troubleshoot them.

System Configuration Errors


• “Missing Solver Configuration Block” on page 4-27
• “Extra Fluid Block or Gas Properties Block” on page 4-27
• “Missing Reference Block” on page 4-28
• “Basic Errors in Physical System Representation” on page 4-28

Missing Solver Configuration Block

Each topologically distinct Simscape block diagram requires exactly one Solver
Configuration block to be connected to it. The Solver Configuration block specifies the
global environment information and provides parameters for the solver that your model
needs before you can begin simulation.

If you get an error message about a missing Solver Configuration block, open the
Simscape Utilities library and add the Solver Configuration block anywhere on the
circuit.

Extra Fluid Block or Gas Properties Block

If your model contains hydraulic elements, each topologically distinct hydraulic circuit in
a diagram requires a Custom Hydraulic Fluid block (or Hydraulic Fluid block, available
with SimHydraulics block libraries) to be connected to it. These blocks define the fluid
properties that act as global parameters for all the blocks connected to the hydraulic
circuit. If no hydraulic fluid block is attached to a loop, the hydraulic blocks in this loop
use the default fluid. However, more than one hydraulic fluid block in a loop generates an
error.

Similarly, more than one Gas Properties block in a pneumatic circuit generates an error.

If you get an error message about too many domain-specific global parameter blocks
attached to the network, look for an extra Hydraulic Fluid block, Custom Hydraulic Fluid
block, or Gas Properties block and remove it.

4-27
4 Model Simulation

Missing Reference Block

Simscape libraries contain domain-specific reference blocks, which represent reference


points for the conserving ports of the appropriate type. For example, each topologically
distinct electrical circuit must contain at least one Electrical Reference block, which
represents connection to ground. Similarly, hydraulic conserving ports of all the blocks
that are referenced to atmosphere (for example, suction ports of hydraulic pumps, or
return ports of valves, cylinders, pipelines, if they are considered directly connected
to atmosphere) must be connected to a Hydraulic Reference block, which represents
connection to atmospheric pressure. Mechanical translational ports that are rigidly
clamped to the frame (ground) must be connected to a Mechanical Translational
Reference block, and so on.

If you get an error message about a missing reference block, or node, check your system
configuration and add the appropriate reference block based on the rules described
above. The missing reference node diagnostic messages include information about the
particular block and variable that needs a reference node. This is especially helpful when
multiple domains are involved in the model. For more information and examples of best
modeling practices, see “Grounding Rules” on page 1-36.

Basic Errors in Physical System Representation

Physical systems are represented in the Simscape modeling environment as Physical


Networks according to the Kirchhoff's generalized circuit laws. Certain model
configurations violate these laws and are therefore illegal. There are two broad
violations:

• Sources of domain-specific Across variable connected in parallel (for example, voltage


sources, hydraulic pressure sources, or velocity sources)
• Sources of domain-specific Through variable connected in series (for example, electric
current sources, hydraulic flow rate sources, force or torque sources)

These configurations are impossible in the real world and illegal theoretically. If your
model contains such a configuration, upon simulation the solver issues an error followed
by a list of blocks, as shown in the following example.
Example

The model shown in the following illustration contains two Ideal Translational Velocity
Sources connected in parallel. This produces a loop of independent velocity sources, and
the solver cannot construct a consistent system of equations for the circuit.

4-28
Troubleshooting Simulation Errors

When you try to simulate the model, the solver issues an error message with links
to the Ideal Translational Velocity Source and Ideal Translational Velocity Source1
blocks. To fix the circuit, you can either replace the two velocity sources by a single Ideal
Translational Velocity Source block, or add a Translational Damper block between them.

Numerical Simulation Issues


• “Dependent Dynamic States” on page 4-29
• “Parameter Discontinuities” on page 4-30

Numerical simulation issues can be either a result of certain circuit configurations or of


parameter discontinuities.

Dependent Dynamic States

Certain circuit configurations can result in dependent dynamic states, or the so-called
higher-index differential algebraic equations (DAEs). Simscape solver can handle
dependencies among dynamic states that are linear in the states and independent of
time and inputs to the system. For example, capacitors connected in parallel or inductors
connected in series will not cause any problems. Other circuit configurations with
dependent dynamic states, in certain cases, may slow down the simulation or lead to an
error when the solver fails to initialize.

Problems may occur when dynamic states have a nonlinear algebraic relationship. An
example is two inertias connected by a nonlinear gear constraint, such as an elliptical
gear. In case of simulation failure, the Simscape solver may be able to identify the

4-29
4 Model Simulation

components involved, and provide an error message with links to the blocks and to the
equations within each block.

Parameter Discontinuities

Nonlinear parameters, dependent on time or other variables, may also lead to numerical
simulation issues as a result of parameter discontinuity. These issues usually manifest
themselves at the transient initialization stage (see “Transient Simulation Issues” on
page 4-30).

Initial Conditions Solve Failure


The initial conditions solve, which solves for all system variables (with initial conditions
specified on some system variables), may fail. This has several possible causes:

• System configuration error. In this case, the Simulation Diagnostics window usually
contains additional, more specific, error messages, such as a missing reference
node, or a warning about the component equations, followed by a list of components
involved. See “System Configuration Errors” on page 4-27 for more information.
• Dependent dynamic state. In this case, the Simulation Diagnostics window also
may contain additional, more specific, error messages, such as a warning about the
component equations, followed by a list of components involved. See “Dependent
Dynamic States” on page 4-29 for more information.
• The constraint residual tolerance may be too tight to produce a consistent solution to
the algebraic constraints at the beginning of simulation. You can try to increase the
Constraint Residual Tolerance parameter value (that is, relax the tolerance) in
the Solver Configuration block.

If the Simulation Diagnostics window has other, more specific, error messages, address
them first and try rerunning the simulation. See also “Troubleshooting Tips and
Techniques” on page 4-26.

Transient Simulation Issues


• “Transient Initialization Not Converging” on page 4-31
• “Step-Size-Related Errors — Dependent States — High Stiffness” on page 4-31

Transient initialization happens at the beginning of simulation (after computing the


initial conditions) or after a subsequent event, such as a discontinuity (for example,

4-30
Troubleshooting Simulation Errors

when a hard stop hits the stop). It is performed by fixing all dynamic variables and
solving for algebraic variables and derivatives of dynamic variables. The goal of transient
initialization is to provide a consistent set of initial conditions for the next transient solve
step.

Transient Initialization Not Converging

Error messages stating that transient initialization failed to converge, or that a set of
consistent initial conditions could not be generated, indicate transient initialization
issues. They can be a result of parameter discontinuity. Review your model to find the
possible sources of discontinuity. See also “Troubleshooting Tips and Techniques” on page
4-26.

You can also try to decrease the Constraint Residual Tolerance parameter value (that
is, tighten the tolerance) in the Solver Configuration block.

Step-Size-Related Errors — Dependent States — High Stiffness

A typical step-size-related error message may state that the system is unable to reduce
the step size without violating the minimum step size for a certain number of consecutive
times. This error message indicates numerical difficulties in solving the Differential
Algebraic Equations (DAEs) for the model. This might be caused by dependent dynamic
states (higher-index DAEs) or by the high stiffness of the system. You can try the
following:

• Tighten the solver tolerance (decrease the Relative Tolerance parameter value in
the Configuration Parameters dialog box)
• Specify a value, other than auto, for the Absolute Tolerance parameter in the
Configuration Parameters dialog box. Experiment with this parameter value.
• Tighten the residual tolerance (decrease the Constraint Residual Tolerance
parameter value in the Solver Configuration block)
• Increase the value of the Number of consecutive min step size violations
allowed parameter in the Configuration Parameters dialog box (set it to a value
greater than the number of consecutive step size violations given in the error
message)
• Review the model configuration and try to simplify the circuit, or add small parasitic
terms to your circuit to avoid dependent dynamic states. For more information, see
“Numerical Simulation Issues” on page 4-29.

4-31
4 Model Simulation

Limitations

In this section...
“Sample Time and Solver Restrictions” on page 4-32
“Algebraic Loops” on page 4-32
“Restricted Simulink Tools” on page 4-33
“Unsupported Simulink Tools and Features” on page 4-35
“Simulink Tools Not Compatible with Simscape Blocks” on page 4-35
“Code Generation” on page 4-35

Sample Time and Solver Restrictions


The default sample times of Simscape blocks are continuous. You cannot simulate
Simscape blocks with discrete solvers using the default sample times.

If you switch to a local solver in the Solver Configuration block, the states of the
associated physical network become discrete. If there are no continuous Simulink or
Simscape states anywhere in a model, you are free to use a discrete solver to simulate the
model.

You cannot override the sample time of a nonvirtual subsystem containing Simscape
blocks.

Algebraic Loops
A Simscape physical network should not exist within a Simulink algebraic loop. This
means that you should not directly connect an output of a PS-Simulink Converter block
to an input of a Simulink-PS Converter block of the same physical network.

For example, the following model contains a direct feedthrough between the PS-Simulink
Converter block and the Simulink-PS Converter block (highlighted in magenta). To
avoid the algebraic loop, you can insert a Transfer Function block anywhere along the
highlighted loop.

4-32
Limitations

A better way to avoid an algebraic loop without introducing additional dynamics is shown
in the modified model below.

Restricted Simulink Tools


Certain Simulink tools are restricted for use with Simscape software:

• You can use the Simulink set_param and get_param commands to set or get
Simscape block parameters, if the parameters correspond to fields in the block dialog
box. MathWorks® does not recommend that you use these commands to find or change
any other block parameters.

4-33
4 Model Simulation

If you make changes to block parameters at the command line, run your model first
before saving it. Otherwise, you might save invalid block parameters. Any block
parameter changes that you make with set_param are not validated unless you run
the model.
• Simscape blocks accept Simulink.Parameter objects as parameter values in
get_param and set_param, within the restrictions specified here.
• Enabled subsystems can contain Simscape blocks. Always set the States when
enabling parameter in the Enable dialog to held for the subsystem's Enable port.

Setting States when enabling to reset is not supported and can lead to fatal
simulation errors.
• You can place Simscape blocks within nonvirtual subsystems that support continuous
states. Nonvirtual subsystems that support continuous states include Enabled
subsystems and Atomic subsystems. However, physical connections and physical
signals must not cross nonvirtual boundaries. When placing Simscape blocks in a
nonvirtual subsystem, make sure to place all blocks belonging to a given Physical
Network in the same nonvirtual subsystem.
• Nonvirtual subsystems that do not support continuous sample time blocks (such as
If Action, For Iterator, Function-Call, Triggered, While Iterator, and so on) cannot
contain Simscape blocks.
• An atomic subsystem with a user-specified (noninherited) sample time cannot contain
Simscape blocks.
• Simulink configurable subsystems work with Simscape blocks only if all of the block
choices have consistent port signatures.
• When using SimState to save and restore simulations of models, you cannot make any
changes to the Simscape blocks in the model between the time at which you save the
SimState and the time at which you restore the simulation using the SimState.

This is an extension of the Simulink limitation prohibiting structural changes to the


model between these two points in time (see “Limitations of SimState”). Changes to
Simscape block parameters can cause equation changes and result in changes to the
state representation. Therefore, modifying parameters of Simscape blocks between
saving and restoring the SimState is not allowed.
• Linearization with the Simulink linmod function or with equivalent Simulink
Control Design™ functions and graphical interfaces is not supported with Simscape
models if you use local solvers.
• Model referencing is supported, with some restrictions:

4-34
Limitations

• All Physical connection lines must be contained within the referenced model.
Such lines cannot cross the boundary of the referenced model subsystem in the
referencing model.
• The referencing model and the referenced model must use the same solver.
• You cannot create Simulink signal objects directly on the PS-Simulink Converter
block outputs. Insert a Signal Conversion block after the output port of a PS-Simulink
Converter block and specify the signal object on the output of the Signal Conversion
block instead.

Unsupported Simulink Tools and Features


Certain Simulink tools and features do not work with Simscape software:

• The Simulink Profiler tool does not work with Simscape models.
• Exporting a model to a format used by an earlier version (File > Export Model to >
Previous Version) is not supported for models containing Simscape blocks.
• Physical signals and physical connection lines between conserving ports are different
from Simulink signals. Therefore, the Signal and Scope Manager tool and the signal
label functionality are not supported.
• Simscape block names cannot contain cross-locale non-ASCII characters.

Simulink Tools Not Compatible with Simscape Blocks


Some Simulink tools and features do not work with Simscape blocks:

• Execution order tags do not appear on Simscape blocks.


• Simscape blocks do not invoke user-defined callbacks.
• You cannot set breakpoints on Simscape blocks.
• Reusable subsystems cannot contain Simscape blocks.
• You cannot use the Simulink Fixed-Point Tool with Simscape blocks.
• The Report Generator reports Simscape block properties incompletely.

Code Generation
Code generation is supported for Simscape physical modeling software and its family
of add-on products. However, there are restrictions on code generated from Simscape
models.

4-35
4 Model Simulation

• Code reuse is not supported.


• Encapsulated C++ code generation is not supported.
• Tunable parameters are not supported.
• Run-time parameter inlining ignores global exceptions.
• Simulation of Simscape models on fixed-point processors is not supported.
• Block diagnostics in error messages are not supported. This means that if you get
an error message from simulating generated code, it does not contain a list of blocks
involved.
• Conversion of models or subsystems containing Simscape blocks to S-functions is not
supported.

“Code Generation” describes Simscape code generation features. “Restricted Simulink


Tools” on page 4-33 describes limitations on model referencing.

There are variations and exceptions as well in the code generation features of the add-on
products based on Simscape platform. For details, see documentation for individual add-
on products.

Code Generation and Fixed-Step Solvers

Most code generation options for Simscape models require the use of fixed-step Simulink
solvers. This table summarizes the available solver choices, depending on how you
generate code.

Code Generation Option Solver Choices


Accelerator mode Variable-step or fixed-step
Rapid Accelerator mode
Simulink Coder™ software: RSim Target* Variable-step or fixed-step
Simulink Coder software: Targets other than Fixed-step only
RSim

* For the RSim Target, Simscape software supports only the Simulink solver module.
In the model Configuration Parameters dialog box, see the Code Generation: RSim
Target: Solver selection menu. The default is automatic selection, which might fail to
choose the Simulink solver module.

4-36
References

References
[1] Moler, C. B., Numerical Computing with MATLAB, Philadelphia, Society for
Industrial and Applied Mathematics, 2004, chapter 7

[2] Horowitz, P., and Hill, W., The Art of Electronics, 2nd Ed., Cambridge, Cambridge
University Press, 1989, chapter 2

[3] Brogan, W. L., Modern Control Theory, 2nd Ed., Englewood Cliffs, New Jersey,
Prentice-Hall, 1985

4-37
5

Variable Initialization and State


Viewer

• “About Variable Initialization” on page 5-2


• “Set Priority and Initial Target for Block Variables” on page 5-5
• “Initialize Variables for a Mass-Spring-Damper System” on page 5-7
• “Variable Viewer” on page 5-23
5 Variable Initialization and State Viewer

About Variable Initialization


In this section...
“Initializing Block Variables for Model Simulation” on page 5-2
“Variable Initialization Priority” on page 5-3
“Suggested Workflow” on page 5-4

Initializing Block Variables for Model Simulation


At the beginning of simulation (t = 0), the solver computes the initial conditions to
determine the simulation starting point, as described in “Initial Conditions Computation”
on page 4-8. Finding a solution means finding initial values for all system variables. You
can affect the initial conditions computation by block-level variable initialization, that is,
by specifying the priority and target initial values for certain variables on the Variables
tab of the respective block dialog boxes.

The values you specify during block-level variable initialization are not the actual values
of the respective variables, but rather their target values at the beginning of simulation
(t = 0). Depending on the results of the solve, some of these targets may or may not be
satisfied.

The solver tries to find a solution that:

• Exactly satisfies all the model equations


• Exactly satisfies all the high-priority targets
• Approximates the low-priority targets as closely as possible (as a result, some of the
low-priority targets might be satisfied exactly, the others are approximated)

If the solver cannot find a solution that exactly satisfies all the high-priority targets, it
issues a warning and enters the second stage of the solve process, where it tries to find a
solution by approximating both the high-priority and the low-priority targets as closely
as possible.

If you have selected the Start simulation from steady state check box in the Solver
block dialog box, the solver attempts to find the steady state (when the system variables
are no longer changing with time). If the steady-state solve succeeds, the state found
is some steady state (within tolerance), but not necessarily the state expected from the
given initial conditions. In other words, if simulation starts from steady state, even the
high-priority variable targets might no longer be satisfied at the start of simulation.

5-2
About Variable Initialization

However, if the model has more than one steady state, the variable targets you specify
can affect which steady-state solution is selected by the solver.

After you initialize the block variables and prior to simulating the model, you can open
the Variable Viewer to see which of the variable targets have been satisfied. The Variable
Viewer displays the actual initial values of the variables obtained as a result of the solve,
along with the variable target values, priority, and other information about the variable.
For details, see “Variable Viewer” on page 5-23.

Variable Initialization Priority


During block-level variable initialization, you specify the variable beginning value, unit,
and the initialization priority. The priority can be one of the following:

• None — If a variable has priority of none, the initialization algorithm starts at the
beginning value for this variable but does not remember this value as it finds the
solution for the system of equations. The solver does not try to satisfy any specific
initial value for a variable with no priority.
• Low — If a variable has low priority, the beginning value becomes a target for the
algorithm and the algorithm tries to stay close to the target. The solver tries to
approximate the target value of this variable as closely as possible when finding a
solution. Depending on the results of the solve for high-priority variables, some of the
low-priority targets might be met exactly, the others are approximated.
• High — If a variable has high priority, the beginning value becomes a target for the
algorithm and the algorithm tries to meet the target exactly. The solver tries to find
a solution where the actual initial values of all high-priority variables exactly satisfy
their target values.

The default initialization priority, beginning value, and unit for each of the block
variables come from the underlying Simscape component file. For each individual block
in your model, you can override these default settings by opening the Variables tab
of the block dialog box, selecting the Override check box next to a variable name and
specifying your own values for that variable.

When you specify too many high-priority targets for system variables, it is possible to
over-specify your model. In this case, the solver might not be able to find a solution that
exactly satisfies all the high-priority targets, or even fail to find a solution altogether. For
an example of how you can deal with over-specification by using the Variable Viewer and
changing the variable priority and targets, see “Initialize Variables for a Mass-Spring-
Damper System” on page 5-7.

5-3
5 Variable Initialization and State Viewer

For detailed information on how to specify variable priority and targets in block dialog
boxes, see “Set Priority and Initial Target for Block Variables” on page 5-5.

Suggested Workflow
1 Using the Variables tab of the respective block dialog boxes, specify the variable
targets for initialization, by setting the priority, target values, and units for block
variables as required by your model.
2 Open the Variable Viewer to see which of the initial targets have been satisfied.
Although the viewer does not simulate the model, it runs the simulation for 0
seconds to initialize it, and therefore the model must be in an executable state.
3 If initialization fails, or you are not satisfied with the results, iterate by changing the
block variable target values and priority, then refreshing the viewer.
4 When satisfied with initialization, run the simulation to see the results.

Related Examples
• “Set Priority and Initial Target for Block Variables” on page 5-5
• “Initialize Variables for a Mass-Spring-Damper System” on page 5-7

More About
• “Variable Viewer” on page 5-23

5-4
Set Priority and Initial Target for Block Variables

Set Priority and Initial Target for Block Variables


When you open the Variables tab of a block dialog box, it lists all the public variables
specified in the underlying component file, along with priority, beginning (target) value,
and unit. For example, if you add a Translational Spring block to your model, double-
click it to open its dialog box, and then click the Variables tab, it looks like this:

For details on these variables and their usage in the block equations, click the Source
code link in the block dialog box to view the underlying Simscape source file. The
Source code link is available for all the Foundation library blocks that have a
Variables tab.

To specify the initial deformation of the spring, select the Override check box next to the
Deformation variable, to indicate that you are overriding the default values. Select the
initialization priority for the variable, by setting its Priority drop-down to High, Low,
or None. Type a new number into the Beginning Value field and change the unit, if
desired. The Unit drop-down lists contains all the units defined in the unit registry that
are commensurate with the one specified in the variable declaration. In the following
dialog box, Deformation is specified as a high-priority variable with the initial target of
20 mm.

5-5
5 Variable Initialization and State Viewer

If you clear the Override check box next to a variable name, its Priority, Beginning
Value, and Unit fields switch back to defaults specified in the component file. However,
if you select the check box again, these fields will retain their last specified value for
when they were overridden.

Related Examples
• “Initialize Variables for a Mass-Spring-Damper System” on page 5-7

More About
• “About Variable Initialization” on page 5-2

5-6
Initialize Variables for a Mass-Spring-Damper System

Initialize Variables for a Mass-Spring-Damper System


This example shows how to use block variable initialization, and how it affects the
simulation results of a simple mechanical system.

The model is a classical unforced mass-spring-damper system, with the oscillations of the
mass caused by the initial deformation of the spring.

Create and Set Up the Model

1 Create a simple mass-spring-damper system. Use the Mass, Translational


Spring, Translational Damper, Mechanical Translational Reference,
Ideal Translational Motion Sensor, PS-Simulink Converter, Solver
Configuration, and Scope blocks, and connect them as shown in the following
illustration.

2 Prepare the model for simulation. On the top menu bar of the model window, select
Simulation > Model Configuration Parameters. Under Solver options, set
Solver to ode23t (mod.stiff/Trapezoidal) and Max step size to 0.2. Also
adjust the Simulation time to be between 0 and 2 seconds, by setting Stop time to
2.0.
3 Specify the initial deformation of the spring. Double-click the Translational Spring
block. In the block dialog box, click the Variables tab, and then select the check
box next to the Deformation variable. Change its Priority to High. Change the
Beginning Value to 0.1. Leave the Unit unchanged as m.

5-7
5 Variable Initialization and State Viewer

4 Adjust the initial position of the sensor, to compensate for the spring deformation.
Double-click the Ideal Translational Motion Sensor block and set its Initial
position parameter value to 0.1 m as well. This way, when you simulate the model,
mass oscillations center around 0.
5 Simulate the model.

5-8
Initialize Variables for a Mass-Spring-Damper System

6 Open the Variable Viewer. In the top menu bar of the model window, select
Analysis > Simscape > Variable Viewer.

5-9
5 Variable Initialization and State Viewer

The Translational Spring variable x, in the bottom row, has high priority and the
target value of 0.1 m. This is the Deformation variable that you have just set up in
the block dialog box. Its actual start value matches its target value, and therefore its
Status column displays a green circle.

The other high-priority variable in this model is the position, x, of the Ideal
Translational Motion Sensor block, which is set inside the component file because
it is necessary for the correct operation of the sensor. Its actual start value also
matches its target value, and its Status column also displays a green circle.

The rest of the variables in the model do not have initialization priority specified,
therefore their Status column also displays green circles. The overall status at the
bottom of the Variable Viewer window displays a green circle as well, and says that
all the variable targets are satisfied.

5-10
Initialize Variables for a Mass-Spring-Damper System

Change Initialization Targets

You can now see how specifying different variable targets affects system initialization
and simulation results.

1 Specify the initial velocity of the mass. Double-click the Mass block, go to the
Variables tab, select the check box next to the Velocity variable, change its
Priority to High, and enter a beginning value of 10. Keep the unit m/s.

2
Refresh the Variable Viewer by clicking .

5-11
5 Variable Initialization and State Viewer

You can see that the solver has found a different initial solution, which satisfies
your variable targets for spring deformation and mass velocity. The Status column
displays green circles, and the overall status at the bottom of the Variable Viewer
window also displays a green circle and says that all the variable targets are
satisfied.
3 Notice that when you refreshed the Variable Viewer, the scopes turned blank. This
happens because solver runs the simulation for 0 seconds to find the initial solution
and display it in the Variable Viewer.

Rerun the simulation and examine the Velocity and Position scope windows, to see
the effect of the new initial value for mass velocity on the simulation results.

5-12
Initialize Variables for a Mass-Spring-Damper System

Deal with Over-Specification

As you specify additional variable targets, sometimes it is possible to over-specify the


constraints.

5-13
5 Variable Initialization and State Viewer

1 Double-click the Translational Damper block, go to the Variables tab, select the
check box next to the Force variable, change its Priority to High, and enter a
beginning value of 200. Keep the unit N.

2 Refresh the Variable Viewer.

5-14
Initialize Variables for a Mass-Spring-Damper System

The overall status at the bottom of the Variable Viewer window now displays a red
square and says that the solver is unable to satisfy all the high-priority variable
targets. There are red squares in the Status column for the two high-priority
variables with targets not satisfied, as well as for their parent blocks.

Notice that the solver has been able to find a solution for model initialization. If you
rerun the simulation, it runs without errors and you can see the new simulation
results.

5-15
5 Variable Initialization and State Viewer

However, the Variable Viewer shows that the model initialization solution does not
satisfy your target values for block variables. This happens because placing high-
priority constraints on all three elements of the mass-spring-damper system results
in a conflict. You can resolve the over-specification issue by relaxing the priority of
some of the conflicting variable targets.

5-16
Initialize Variables for a Mass-Spring-Damper System

3 Double-click the Translational Damper block again, go to the Variables tab, and
change the priority of the Force variable to Low.

4 Refresh the Variable Viewer.

5-17
5 Variable Initialization and State Viewer

The overall status at the bottom of the Variable Viewer window now displays a
yellow triangle and says that all the high-priority targets are satisfied, but some of
the low-priority targets are not satisfied. There are now two yellow triangles in the
status column: one for the low-priority force variable f and one for its parent block,
Translational Damper.

Essentially, the solution found in this case is the same as when you previously
specified high-priority target for the mass velocity, and the simulation results are the
same.

5-18
Initialize Variables for a Mass-Spring-Damper System

5 Another way to deal with over-specification is to keep the high priority on the
damper force and relax the priority on mass initial velocity. Double-click the
Translational Damper block again, go to the Variables tab, and change the priority
of the Force variable back to High. Then double-click the Mass block, go to the
Variables tab, and change the priority of the Velocity variable to Low.

5-19
5 Variable Initialization and State Viewer

6 Refresh the Variable Viewer.

5-20
Initialize Variables for a Mass-Spring-Damper System

Again, the Variable Viewer status says that all the high-priority targets have
been satisfied and that some of the low-priority targets are not satisfied. However,
because you changed the variable priorities, the solver now tried to satisfy the initial
force on the damper rather than the mass velocity, and the solution is different in
this case, as are the simulation results.

5-21
5 Variable Initialization and State Viewer

Related Examples
• “Set Priority and Initial Target for Block Variables” on page 5-5

More About
• “About Variable Initialization” on page 5-2
• “Variable Viewer” on page 5-23

5-22
Variable Viewer

Variable Viewer
In this section...
“About Variable Viewer” on page 5-23
“Advanced Configuration” on page 5-25
“Switching Between Tree View and Flat View” on page 5-27
“Useful Filtering Techniques” on page 5-29
“Link to Block Diagram” on page 5-30
“Interaction with Model Updates and Simulation” on page 5-31

About Variable Viewer


Prior to simulating the model, you can use the Variable Viewer to check the results of the
initial conditions computation for the model and to see which of the block-level variable
initialization targets have been satisfied. The Variable Viewer displays the variable
priority and target values, where specified, along with the actual initial values for all the
variables obtained as a result of the solve.

To open the Variable Viewer, in the top menu bar of the model window, select Analysis >
Simscape > Variable Viewer.

The Variable Viewer is a table, its rows listing all the blocks in the model and all the
public variables under each block, and the columns providing the initialization status,
priority, target and actual start values, and other information for each variable.

5-23
5 Variable Initialization and State Viewer

By default, the Variable Viewer opens in basic configuration, which has the following
columns:
Name Description
Status Initialization status of each variable, can be one of:

• Green circle — Displayed for variables with initialization targets


satisfied, and also for all variables with no initialization priority.
• Yellow triangle — Displayed for low-priority variables if the target
is not satisfied.
• Red square — Displayed for high-priority variables if the target is
not satisfied.
• Red cross — If initial condition solve fails, displayed for variables
that could not be initialized.
• Gray rectangle — Displayed when status is not available. This can
happen, for example, if model initialization failed, or if the viewer
was left open during diagram update. For more information, see
“Interaction with Model Updates and Simulation” on page 5-31.
Priority Variable initialization priority, as specified in the block dialog box
or in the underlying component file. For more information, see “Set
Priority and Initial Target for Block Variables” on page 5-5 and
“Variable Priority for Model Initialization”. If the variable has no
initialization priority (None or priority.none), then this field is
empty.
Target Initial target value for a high-priority or low-priority variable. If the
variable has no initialization priority, then this field is empty.
Start The actual initial value of the variable computed by the solver.
Unit The variable base unit, common for all the values (Target, Prestart,
and Start). Simscape unit manager automatically converts all the
values as needed. For example, if you specified the target Beginning
Value in the block dialog box as 20 and the Unit as mm, the Variable
Viewer displays the Target as 0.2 and Unit as m.

A downward-pointing arrow next to a column name indicates that you can filter the table
rows based on their value in this column. For more information on the filtering options,
see “Useful Filtering Techniques” on page 5-29.

The Variable Viewer toolbar buttons perform the following actions:

5-24
Variable Viewer

Displays the data in the Variable Viewer in tree view, with variable nodes grouped
under the parent port, block, and subsystem nodes. This is the default view.
Displays the data in the Variable Viewer in flat view, to minimize the number of
rows in the table. In flat view, the rows for parent nodes are not shown, and the
table contains just one row per variable, with the Name column including the
complete path to the variable from the model root. If the Variable Viewer is in flat
view, the buttons that expand and collapse nodes are disabled.
Expands all nodes, showing all variables under each block name. This button is
available only if the Variable Viewer is in tree view.
Collapses all variables under each block name. You can then expand the block
nodes individually to see the variables under this block. This button is available
only if the Variable Viewer is in tree view.
Recomputes the initial conditions for the model and refreshes the values displayed
in the viewer. Use this button after adjusting the block parameter values,
changing variable priorities and targets, or updating the block diagram. For more
information, see “Interaction with Model Updates and Simulation” on page 5-31.
Clears all the column filtering options and displays all the rows in the table. For
more information, see “Useful Filtering Techniques” on page 5-29.
Shows the Variable Viewer in its default, basic, configuration, with only the
following columns displayed: Status, Priority, Target, Start, and Unit.
Shows the Variable Viewer in advanced configuration, with all the columns
displayed. Use this view for troubleshooting your model, for example, if the model
initialization failed.

Advanced Configuration
In most cases, the default Variable Viewer configuration contains sufficient data for
viewing the variable targets and verifying the model initialization results. However,
if the solver is unable to satisfy all the high-priority variable targets, or if the model
initialization fails, the advanced Variable Viewer configuration might provide additional
data that can help you troubleshoot your model.

To switch to the advanced configuration, click in the Variable Viewer toolbar.

5-25
5 Variable Initialization and State Viewer

In advanced configuration, the Variable Viewer displays the following additional


columns:

Name Description
Prestart The value of the variable that the solver uses at the beginning of
the initial conditions solve process. For variables with no override
of initialization priority and targets, the prestart values come from
the variable declaration in the underlying component file. If the
initialization process fails, these values can help you determine the
reason (for example, a prestart value of 0 for a variable used as a
denominator in a model equation). If a variable has an undesirable
prestart value, specify a better value as a low-priority (or no-priority)
initialization target, to make the solver start iterations from a
different point.
Eliminated These variables are eliminated by the software prior to numerical
integration and are not used in solving the system. Prestart values for
these variables have no effect on the system solution. However, you
can set the initialization priority and targets on these variables, in
which case their targets will be represented in terms of the variables
that are retained by the solver.
Determined The values of these variables depend on the system inputs, or
their values are predetermined based on the analysis of equations.
Therefore, specifying initialization priority and targets for these
variables has little or no impact on system solution. Also, if you
specify a high-priority target for a predetermined variable, the solver

5-26
Variable Viewer

Name Description
most likely will not be able to satisfy this target but will spend extra
time trying to find a second-stage solution.
Differential Time derivatives of these variables appear in equations. These
variables add dynamics to the system and can produce independent
states. Therefore, these variables are more likely to require high
initialization priority.

You can change the default order of columns by clicking a column heading and dragging
it, while holding down the mouse button, to the desired location. You can also hide
columns by right-clicking their headers and selecting Hide This Column from the

context menu, or clearing the check mark next to a column name. Clicking or in
the Variable Viewer toolbar restores the default basic or advanced layout, respectively.

Switching Between Tree View and Flat View


You can control the number of rows in the Variable Viewer by switching between the
tree view (the default) and the flat view. By default, the Variable Viewer opens in
tree view, with variable nodes grouped under the parent port, block, and subsystem
nodes. Therefore, the Variable Viewer table contains the rows for the parent nodes
(ports, blocks, and subsystems) in addition to the rows that correspond to all the public
variables. Only the rows that represent variables contain data such as targets and actual
values. All rows display a status, with the status of a parent node being determined by
the status of its children variables: if all the children are green, then the row for the
parent node also displays a green circle in its Status column.

For example, in the Variable Viewer table below, the first row represents the Ideal
Translational Motion Sensor block, the second row — port C of this block, and only the
third row contains the data for the actual variable v (velocity at port C).

5-27
5 Variable Initialization and State Viewer

To switch to the flat view, click in the Variable Viewer toolbar.

5-28
Variable Viewer

In flat view, the rows for parent nodes are not shown, and the table contains just one
row per variable, with the Name column including the complete path to the variable
from the top-level model. For example, the first row of the Variable Viewer table in flat
view represents the same variable v (velocity at port C of the Ideal Translational Motion
Sensor block), and the Name column includes the names of its parents and shows the
path to the variable. Flat view makes the Variable Viewer table more compact.

If the Variable Viewer is in flat view, the buttons that expand and collapse nodes are
disabled.

To switch back to the tree view, click in the Variable Viewer toolbar.

Useful Filtering Techniques


A downward-pointing arrow next to a column name indicates that you can filter the table
rows based on their value in this column.

To filter the rows, click the arrow, and then select or clear the check boxes in the drop-
down list to indicate which rows you want to be displayed, based on their value. Selecting

All clears all the filters for that column. To clear all filters for all columns, click in
the Variable Viewer toolbar.

5-29
5 Variable Initialization and State Viewer

For example, filtering on the Priority column values (selecting only the check boxes for
HIGH and LOW) lets you view all the targets and actual values in a compact format, which
can be helpful for a large model.

You might also find the following filtering techniques useful in troubleshooting your
models:

• Filter the Differential column on TRUE, to display only the rows for differential
variables. Time derivatives of these variables appear in equations. These variables
add dynamics to the system and can produce independent states, therefore these
variables are more likely to require high initialization priority.
• Filter the Determined column on TRUE, to verify that these variables have no
initialization priority. The values of these variables are either predetermined by
the equation analysis or depend on the system inputs, and therefore specifying
initialization priority and targets for these variables has little or no effect on model
initialization.

Link to Block Diagram


The Variable Viewer tool provides direct linking to the block diagram. This link lets
you highlight the appropriate block, or easily go from a variable listed in the Variable
Viewer to the Variables tab in the corresponding block dialog box, to modify the variable
priorities and targets.

When you right-click in the Name column of any row in the Variable Viewer table, a
context menu opens with the following options:

• Go to block — Highlights the corresponding block in the block diagram, opening


the appropriate subsystem if needed. If the row represents a variable, highlights the
parent block for this variable.
• Open block dialog — Opens the corresponding block dialog box (for a variable,
opens the parent block dialog box). In the block dialog box, click the Variables tab
to view or modify the variable priorities and targets. If the selected row represents a
subsystem, this option is not available.

5-30
Variable Viewer

Interaction with Model Updates and Simulation


The Variable Viewer computes the actual initial values of the variables by running the
simulation for 0 seconds. Therefore:

• The model must be in an executable state when you open or refresh the viewer,
otherwise you get an error message.

5-31
5 Variable Initialization and State Viewer

• If the scopes are open, they turn blank every time you open or refresh the viewer.
Rerun the simulation to see the new results.
• If you rerun the simulation while the Variable Viewer is open, the results in the
viewer are automatically refreshed when the simulation starts running.
• If you change variable priorities and targets or adjust the block parameters while
the Variable Viewer is open, the results in the viewer are not updated automatically.

Refresh the viewer (by clicking in the Variable Viewer toolbar) to compute the
new actual values of the variables and update the status.
• If you update block diagram (by selecting Simulation > Update Diagram in the
top menu bar of the model window) while the Variable Viewer is open, the previously
computed actual values become unavailable and the Status column displays gray
rectangles. The overall status at the bottom of the Variable Viewer window is also not
available. Refresh the viewer to compute the new actual values of the variables and
update the status.

Related Examples
• “Initialize Variables for a Mass-Spring-Damper System” on page 5-7

More About
• “About Variable Initialization” on page 5-2

5-32
6

Linearization and Trimming

• “Finding an Operating Point” on page 6-2


• “Linearizing at an Operating Point” on page 6-7
• “Linearize an Electronic Circuit” on page 6-13
• “Linearize a Plant Model for Use in Feedback Control Design” on page 6-23
6 Linearization and Trimming

Finding an Operating Point

In this section...
“What Is an Operating Point?” on page 6-2
“Finding Operating Points in Physical Models” on page 6-3

What Is an Operating Point?


An operating point of a system is a dynamic configuration that satisfies design and
use requirements called operating specifications. You can express such operating
specifications as requirements on the system state x and inputs u. It is not always
possible to find a dynamic state that satisfies all operating conditions. Also, a system
might have multiple operating points satisfying the same requirements.

Operating points are essential for designing and implementing system controllers.
You can optimize a system at an operating point for performance, stability, safety, and
reliability.

The most important and common type of operating point is a steady state, where some or
all of the system dynamic variables are constant.

Using Operating Points for Linearization

An important motive for finding operating points is linearization, which determines


the system response to small disturbances at an operating point. Linearization results
influence the design of feedback controllers to govern dynamic behavior near the
operating point. A full linearization analysis requires one or more system outputs, y, in
addition to inputs.

See “Linearizing at an Operating Point” on page 6-7.

Example

A pilot flying an aircraft wants to find, for a given environment, a state of the aircraft
engine and control surfaces that produces level, constant-velocity, and constant-altitude
flight relative to the ground. The requirements of "level," "constant velocity," "constant
altitude," and "relative to the ground" constitute operating specifications. This operating
point is a steady state of the aircraft velocity, altitude, and orientation in space.

6-2
Finding an Operating Point

Finding Operating Points in Physical Models


You have a number of ways to find an operating point in a Simscape model. You can
impose operating specifications and isolate operating points using Simscape and
Simulink features.

Tip To find a steady state, the Simscape steady-state solver is the most direct method.
For a comprehensive suite of operating point and linearization tools, MathWorks
recommends Simulink Control Design software.

To analyze operating points, you work with the full state vector of your model, which
contains:

• Simulink components, which can be continuous or discrete.


• Simscape components, which are continuous.

Whichever method that you choose to find an operating point, if you want to use it for
linearization, you must save the operating point information in the form of an operating
point object, a simulation time t0, or a state vector x0 and input vector u0.

• “Simulating in Time to Search for an Operating Point” on page 6-3


• “Using the Simscape Initial Condition Solver” on page 6-4
• “Using Simulink Control Design Techniques to Find Operating Points” on page
6-4
• “Using Sources to Find Operating Points Not Recommended” on page 6-6
• “Simulink trim Function Not Supported with Simscape Models” on page 6-6

Simulating in Time to Search for an Operating Point

One way to identify operating points is to simulate your model and inspect its state x and
output y as a time series.

1 In your Simscape model, set up sensor outputs for whatever block outputs you want
to observe.
2 Connect Scope blocks, To Workspace blocks, or both, to your Simscape block
outputs to observe and record simulation behavior.

6-3
6 Linearization and Trimming

3 In the Data Import/Export pane of your model Configuration Parameters


settings, select the Time, States, and Output check boxes to record this simulation
information in your workspace.

Using the Simscape Initial Condition Solver


Simscape software provides two workflows to initialize a physical model. The first
solves for steady state, where all differential variables have zero derivative. Using
this approach you can search for multiple steady states with the steady-state solver by
varying the model inputs, parameters, and initial conditions. The second approach is to
directly specify initial conditions by specifying initialization priority and targets for block
variables. For more information on this approach, see “Variable Initialization”.

To use the first approach, enable the steady-state solver:

1 In each, some, or all of the physical networks in your Simscape model, open the
Solver Configuration block.
2 In each block dialog box, select the Start simulation from steady state check box.
3 In the model Configuration Parameters settings, on the Data Import/Export pane,
select the States check box to record the time series of x values in your workspace.

If you also have input signals u in the model, you can capture those inputs by
connecting To Workspace blocks to the input Simulink signal lines.
4 Close these dialog boxes and start simulation.

The first vector of values x(t=0) that you capture during simulation reflects the steady
state x0 that the Simscape solver identified.

Tip Finding an initial steady state is part of the nondefault Simscape simulation
sequence. See “Initial Conditions Computation” on page 4-8.

You can simplify the initial steady-state computation by setting the simulation time to 0.
The simulation then solves for one time step only (time zero) and returns a single state
vector x(t=0).

Using Simulink Control Design Techniques to Find Operating Points

Note: The techniques described in this section require the Simulink Control Design
product.

6-4
Finding an Operating Point

You must use the features of this product on the Simulink lines in your model, not
directly on Simscape physical network lines or blocks. Simulink Control Design offers
both command line and graphical interfaces for finding and analyzing operating points.

Simulink Control Design methods are state-based, giving you full access to state names
and values, and allow you to impose operating specifications or use simulation snapshots.
MathWorks does not recommend imposing operating specifications state-by-state using
the Simulink Control Design dialogs (or findop function), but simulation snapshots
work well.

To find operating points, it is simplest to use the operspec and findop functions,
customizing where necessary. Create an operating specification object with operspec,
then compute an operating point object with findop. The findop function attempts
to find an operating point that satisfies the operating specifications and reports on its
success or failure. If the search is successful, find_op returns state values satisfying the
operating specifications.

You have several choices for operating specifications for the components of the state
vector.

Assumed Operating Operating Specification


Condition
Default Request that all state component derivatives be zero.
This is a steady-state for the whole model, not just a Simscape
network within the model.
Nondefault Request any value you want independently for each state
component.
Nondefault Request that a particular state component derivative be zero.
This is a steady-state condition for that state component.

Additional Simulink Control Design Methods

You can also use the graphical user interface, through the model menu bar: Analysis >
Control Design > Linear Analysis. This interface gives you access to state, input, and
output names, structure, and initial values.

For more details on the use of operating point specification objects, related functions, and
the graphical interface, see the Simulink Control Design documentation.

6-5
6 Linearization and Trimming

Using Sources to Find Operating Points Not Recommended

You can impose an operating specification on part of a Simscape model by inserting


source blocks from the Simscape Foundation Library. These impose specified values of
system variables in parts of the model. You can simulate and save the state vector.

However, you cannot obtain an operating point for the original system (without the
source blocks) by saving the state values from the model and then removing the source
blocks. In general, the number, order, and identity of state components change after
adding and removing Simscape blocks in a model.

Simulink trim Function Not Supported with Simscape Models

The Simulink trim function is not supported for models containing Simscape
components.

6-6
Linearizing at an Operating Point

Linearizing at an Operating Point


In this section...
“What Is Linearization?” on page 6-7
“Linearizing a Physical Model” on page 6-9

What Is Linearization?
Determining the response of a system to small perturbations at an operating point is a
critical step in system and controller design. Once you find an operating point, you can
linearize the model about that operating point to explore the response and stability of
the system. To find an operating point in a Simscape model, see “Finding an Operating
Point” on page 6-2.

• “What Is a Linearized Model?” on page 6-7


• “Example” on page 6-8
• “Choosing a Good Operating Point for Linearization” on page 6-8

What Is a Linearized Model?

Near an operating point, you can express the system state x, inputs u, and outputs y
relative to that operating point in terms of x – x0, u – u0, and y – y0. For convenience,
shift the vectors by subtracting the operating point: x – x0 → x, and so on.

If the system dynamics do not explicitly depend on time and the operating point is a
steady state, the system response to state and input perturbations near the steady state
is approximately governed by a linear time-invariant (LTI) state space model:
dx/dt = A·x + B·u
y = C·x + D·u.

The matrices A, B, C, D have components and structures that are independent of the
simulation time. A system is stable to changes in state at an operating point if the
eigenvalues of A are negative.

If the operating point is not a steady state or the system dynamics depend explicitly
on time, the linearized dynamics near the operating point are more complicated. The
matrices A, B, C, D are not constant and depend on the simulation time t0 , as well as the
operating point x0 and u0 [3].

6-7
6 Linearization and Trimming

Tip While you can linearize a closed system with no inputs or outputs and obtain a
nonzero A matrix, obtaining a nontrivial linearized input-output model requires at least
one input component in u and one output component in y.

Example

A pilot is flying, or simulating, an aircraft in level, constant-velocity, and constant-


altitude flight relative to the ground. A crucial question for the aircraft pilot and
designers is: will the aircraft return to the steady state if perturbed from it by a
disturbance, such as a wind gust — in other words, is this steady state stable? If the
operating point is unstable, the aircraft trajectory can diverge from the steady state,
requiring human or automatic intervention to maintain steady flight.

Choosing a Good Operating Point for Linearization

Although steady-state and other operating points (state x0 and inputs u0) might exist for
your model, that is no guarantee that such operating points are suitable for linearization.
The critical question is: how good is the linearized approximation compared to the exact
system dynamics?

• When perturbed slightly, a problematic operating point might exhibit strong


asymmetries, with strongly nonlinear behavior when perturbed in one direction and
smoother behavior in another.
• Small perturbations might result in a discontinuous change in a state value, making
the current state unsuitable for linear approximation.

Operating points with a strongly nonlinear or discontinuous character are not suitable
for linearization. You should analyze such models in full simulation, away from any
discontinuities, and perturb the system by varying its inputs, parameters, and initial
conditions. A common example is actuation systems, which should be linearized away
from any hard constraints or end stops.

Tip Check for such an unsuitable operating point by linearizing at several nearby
operating points. If the results differ greatly, the operating point is strongly nonlinear or
discontinuous.

6-8
Linearizing at an Operating Point

Linearizing a Physical Model


Use the following methods to create numerical linearized state-space models from a
model containing Simscape components.

Tip MathWorks recommends the Simulink Control Design product for linearization
analysis.

• “Independent Versus Dependent States” on page 6-9


• “Linearizing with Simulink Control Design Software” on page 6-10
• “Linearizing with the Simulink linmod and dlinmod Functions” on page 6-10
• “Linearizing with Simulink Linearization Blocks” on page 6-12

Independent Versus Dependent States

An important difference from basic Simulink models is that the states in a physical
network are not independent in general, because some states have dependencies on other
states through constraints.

• The independent states are a subset of system variables and consist of independent
(unconstrained) Simscape dynamic variables and other Simulink states.
• The dependent states consist of Simscape algebraic variables and dependent
(constrained) Simscape dynamic variables.

For more information on Simscape dynamic and algebraic variables, see “How Simscape
Simulation Works” on page 4-5.

The complete, unreduced LTI A, B, C, D matrices have the following structure.

• The A matrix, of size n_states by n_states, is all zeros except for a submatrix of
size n_ind by n_ind, where n_ind is the number of independent states.
• The B matrix, of size n_states by n_inputs, is all zeros except for a submatrix of
size n_ind by n_inputs.
• The C matrix, of size n_outputs by n_states, is all zeros except for a submatrix of
size n_outputs by n_ind.
• The D matrix, of size n_outputs by n_inputs, can be nonzeros everywhere.

6-9
6 Linearization and Trimming

Obtaining the Independent Subset of States

A minimal linearized solution uses only an independent subset of system states. From
the matrices A, B, C, D, you can obtain a minimal input-output linearized model with:

• The minreal and sminreal functions from Control System Toolbox™ software
• Automatically with the Simulink Control Design approach

Linearizing with Simulink Control Design Software

Note: The techniques described in this section require the Simulink Control Design
product.

You must use the features of this product on the Simulink lines in your model, not
directly on Simscape physical network lines or blocks.

This approach requires that you start with an operating point object saved from
trimming the model to an operating specification.

To linearize a model with an operating point object, use the linearize function,
customizing where necessary. The resulting state-space object contains the matrices A, B,
C, D.

Additional Simulink Control Design Methods

You can also use the graphical user interface, through the model menu bar: Analysis >
Control Design > Linear Analysis. For more details on linearization, operating points
and state-space objects, related functions, and the graphical interface, see the Simulink
Control Design documentation.

Linearizing with the Simulink linmod and dlinmod Functions

You have several ways that you can use the Simulink functions linmod and dlinmod,
and the linearization results can differ depending on the method chosen. To use these
functions, you do not have to open the model, just have the model file on your MATLAB
path.

For more information about Simulink linearization, see “Linearizing Models” in the
Simulink documentation.

6-10
Linearizing at an Operating Point

Tip If your model has continuous states, use linmod. (Continuous states are the
Simscape default.) If your model has mixed continuous and discrete states, or purely
discrete states, use dlinmod.

Linearizing a model with the local solver enabled (in the Solver Configuration block)
is not supported.

Linearizing with Default State and Input

You can call linmod without specifying state or input. Enter linmod('modelname') at
the command line.

With this form of linmod, Simulink linearization solves for consistent initial conditions
in the same way it does on the first step of any simulation. Any initial conditions, such as
initial offset from equilibrium for a spring, are set as if the simulation were starting from
the initial time.

linmod allows you to change the time of externally specified signals (but not the internal
system dynamics) from the default. For this and more details, see the linmod function
reference page.
Linearizing with the Steady-State Solver at an Initial Steady State

You can linearize at an operating point found by the Simscape steady-state solver:

1 Open one or more Solver Configuration blocks in your model.


2 Select the Start simulation from steady state check box for the physical networks
that you want to linearize.
3 Close the Solver Configuration dialog boxes and save the modified model.
4 Enter linmod('modelname') at the command line.

linmod linearizes at the first step of simulation. In this case, the initial state is also an
operating point, a steady state.

For more about setting up the steady-state solver, see the Solver Configuration
block reference page.
Linearizing with Specified State and Input — Ensuring Consistency of States

You can call linmod and specify state and input. Enter linmod('modelname',x0,u0)
at the command line. The extra arguments specify, respectively, the steady state x0 and

6-11
6 Linearization and Trimming

inputs u0 for linearizing the simulation. When you specify a state to linmod, ensure that
it is self-consistent, within solver tolerance.

With this form of linmod, Simulink linearization does not solve for initial conditions.
Because not all states in the model have to be independent, it is possible, though
erroneous, to provide linmod with an inconsistent state to linearize about.

If you specify a state that is not self-consistent (within solver tolerance), the Simscape
solver issues a warning at the command line when you attempt linearization. The
Simscape solver then attempts to make the specified x0 consistent by changing some of
its components, possibly by large amounts.

Tip You most easily ensure a self-consistent state by taking the state from some
simulated time. For example, by selecting the States check box on the Data Import/
Export pane of the model Configuration Parameters dialog box, you can capture a time
series of state values in a simulation run.

Linearizing with Simulink Linearization Blocks

You can generate linearized state-space models from your Simscape model by adding
a Timed-Based Linearization or Trigger-Based Linearization block to the
model and simulating. These blocks combine time-based simulation, up to specified times
or internal trigger points, with state-based linearization at those times or trigger points.

For complete details about these blocks, see their respective block reference pages.

Note If your model contains PS Constant Delay or PS Variable Delay blocks, or custom
blocks utilizing the delay operator in the Simscape language, MathWorks recommends
that you linearize the model by using the Timed-Based Linearization or Trigger-
Based Linearization block and simulating the model for a time period longer than
the specified delay time.

6-12
Linearize an Electronic Circuit

Linearize an Electronic Circuit


This example shows how to linearize a model of a nonlinear bipolar transistor circuit and
create a Bode plot for small-signal frequency-domain analysis.

Depending on the software you have available, use the appropriate sections of this
example to explore various linearization and analysis techniques.

In this section...
“Explore the Model” on page 6-13
“Linearize with Steady-State Solver and linmod Function” on page 6-17
“Linearize with Simulink Control Design Software” on page 6-19
“Use Control System Toolbox Software for Bode Analysis” on page 6-20

Explore the Model


To open the Nonlinear Bipolar Transistor example model, type
ssc_bipolar_nonlinear in the MATLAB Command Window.

6-13
6 Linearization and Trimming

The model represents a single-transistor audio amplifier. The transistor is an NPN


bipolar device, and as such has a nonlinear set of current-voltage characteristics.
Therefore the overall behavior of the amplifier is dependent on the operating point
of the transistor. The transistor itself is represented by and Ebers-Moll equivalent
circuit implemented using a masked subsystem. The circuit has a sinusoidal input test
signal with amplitude 10 mV and frequency 1 kHz. The Load Voltage scope displays the
resulting collector output voltage after the DC is filtered out by the output decoupling
capacitor.

R1 and R2 set the nominal operating point, and the small signal gain is approximately
set by the ratio R3/R4. The decoupling capacitors C1 and C2 have a capacitance of 1uF, to
present negligible impedance at 1 kHz.

The model is configured for linearization. You can quickly generate and view the small-
signal frequency response by clicking the Linearize circuit hyperlink in model
annotation. To view the MATLAB script that generates the frequency response, click the
next hyperlink in that annotation, see code. This documentation provides background
information and alternative ways of linearization based on the software you have.

In general, to obtain a nontrivial linearized input-output model and generate a frequency


response, you must specify model-level inputs and outputs. The Nonlinear Bipolar
Transistor model meets this requirement in two ways, depending on how you linearize:

• Simulink requires top- or model-level input and output ports for linearization with
linmod. The Nonlinear Bipolar Transistor model has such ports, marked u and y.
• Simulink Control Design software requires that you specify input and output signal
lines with linearization points. The specified lines must be Simulink signal lines, not
Simscape physical connection lines. The Nonlinear Bipolar Transistor model has such
linearization points specified. For more information on using Simulink Control Design
software for trimming and linearization, see documentation for that product.

Open the Solver Configuration block and see that the Start simulation from steady
state check box is selected. Then open the Load Voltage scope and run the simulation to
see the basic circuit behavior. The transistor junction capacitance initial voltages are set
to be consistent with the bias conditions defined by the resistors. The output is a steady
sinusoid with zero average, its amplitude amplified by the transistor and bias circuit.

6-14
Linearize an Electronic Circuit

To see the circuit relax from a nonsteady initial state, in the Solver Configuration block,
clear the Start simulation from steady state check box and click OK. With the Load
Voltage scope open, simulate again. In this case, the output voltage starts at zero because
the transistor junction capacitances start with zero charge.

6-15
6 Linearization and Trimming

You can get a more comprehensive understanding of the circuit behavior and how it
approaches the steady state by long-time transient simulation. Increase the simulation
time to 1 s and rerun the simulation. The circuit starts from its initial nonsteady state,
and the transistor collector voltage approaches and eventually settles into steady
sinusoidal oscillation.

6-16
Linearize an Electronic Circuit

Open the Solver Configuration block, select the Start simulation from steady state
check box (as it was when you first opened the model), and click OK. Change the
simulation time back to .01 s and rerun the simulation.

Linearize with Steady-State Solver and linmod Function


In this example, you:

1 Use the Simscape steady-state solver to find an operating point


2 Linearize the model using the Simulink linmod function
3 Generate the Bode plot using a series of MATLAB commands

Open the Solver Configuration block and make sure the Start simulation from steady
state check box is selected. When you simulate the model with the Simscape steady-
state solver enabled, the circuit is initialized at the state defined by the transistor bias
resistors. This steady-state solution is an operating point suitable for linearization.

6-17
6 Linearization and Trimming

Note: Also make sure that the Use local solver check box is cleared. Linearizing a
model with the local solver enabled is not supported.

To linearize the model, type the following in the MATLAB Command Window:

[a,b,c,d]=linmod('ssc_bipolar_nonlinear');

You can alternatively call the linmod function with a single output argument, in which
case it generates a structure with states, inputs, and outputs, as well as the linear time-
invariant (LTI) model.

The state vector of the Nonlinear Bipolar Transistor model contains 17 components. The
full model has one input and one output. Thus, the LTI state-space model derived from
linearization has the following matrix sizes:

• a is 17-by-17
• b is 17-by-1
• c is 1-by-17
• d is 1-by-1

To generate a Bode plot with negative feedback convention, type the following in the
MATLAB Command Window:

c = -c; d = -d;
npts = 100; f = logspace(-2,10,npts); G = zeros(1,npts);
for i=1:npts
G(i) = c*(2*pi*1i*f(i)*eye(size(a))-a)^-1*b +d;
end
subplot(211), semilogx(f,20*log10(abs(G)))
grid
ylabel('Magnitude (dB)')
subplot(212), semilogx(f,180/pi*unwrap(angle(G)))
ylabel('Phase (degrees)')
xlabel('Frequency (Hz)')
grid

6-18
Linearize an Electronic Circuit

Linearize with Simulink Control Design Software

Note: To work through this section, you must have a Simulink Control Design license.

Simulink Control Design software has tools that help you find operating points and
returns a state-space model object that defines state names. This is the recommended
way to linearize Simscape models.

1 In the top menu bar of the Nonlinear Bipolar Transistor model, select Analysis >
Control Design > Linear Analysis .
2 In the Linear Analysis Toolstrip, click the Bode plot button.

6-19
6 Linearization and Trimming

For more information on using Simulink Control Design software for trimming and
linearization, see the Simulink Control Design documentation.

Use Control System Toolbox Software for Bode Analysis

Note: To work through this section, you must have a Control System Toolbox license.

You can use the built-in analysis and plotting capabilities of Control System Toolbox
software to analyze and compare Bode plots of different steady states.

First, use the Simulink linmod function to obtain the linear time-invariant (LTI) model.
[a,b,c,d]=linmod('ssc_bipolar_nonlinear');

Not all the states of the LTI model derived in this example are independent. Confirm
this by calculating the determinant of the a matrix, det(a). The determinant vanishes,

6-20
Linearize an Electronic Circuit

which implies one or more zero eigenvalues. To analyze the LTI model, reduce the LTI
matrices to a minimal realization. Obtain a minimal realization using the minreal
function.

[a0,b0,c0,d0] = minreal(a,b,c,d);

13 states removed.

Extracting the minimal realization eliminates 13 dependent states from the LTI model,
leaving four independent states. Analyze the control characteristics of the reduced a0,
b0, c0, d0 LTI model using a Bode plot.

bode(a0,b0,c0,d0) % Creates first Bode plot

The circuit with R1 changed from 47 to 15 kOhm has a different steady state and
response. Double-click the R1 block, change the Resistance value to 15 kOhm, and click
OK. Open the Load Voltage scope and simulate the model. The collector voltage is now no
longer amplified relative to the 10 mV AC source but attenuated.

6-21
6 Linearization and Trimming

Produce the LTI model at the second steady state, reduce it to a minimal realization, and
superpose the second Bode plot on the first one.
[a_R1,b_R1,c_R1,d_R1]=linmod('ssc_bipolar_nonlinear');
[a0_R1,b0_R1,c0_R1,d0_R1] = minreal(a_R1,b_R1,c_R1,d_R1); % 13 states removed.
hold on % Keeps first Bode plot open
bode(a0_R1,b0_R1,c0_R1,d0_R1) % Superposes second Bode plot on first

For more information on using Control System Toolbox software for Bode analysis, see
the Control System Toolbox documentation.

Related Examples
• “Linearize a Plant Model for Use in Feedback Control Design” on page 6-23

More About
• “Finding Operating Points in Physical Models” on page 6-3
• “Linearizing a Physical Model” on page 6-9

6-22
Linearize a Plant Model for Use in Feedback Control Design

Linearize a Plant Model for Use in Feedback Control Design


This example shows how you can linearize a hydraulic plant model to support control
system stability analysis and design.

Depending on the software you have available, use the appropriate sections of this
example to explore various linearization and analysis techniques.

In this section...
“Explore the Model” on page 6-23
“Trim Using the Controller and Linearize with Simulink linmod Function” on page
6-26
“Linearize with Simulink Control Design Software” on page 6-27

Explore the Model


To open the Hydraulic Actuator with Digital Position Controller example model, type
ssc_hydraulic_actuator_digital_control in the MATLAB Command Window.

The model represents a two-way valve acting in a closed-loop circuit together with a
double-acting cylinder. Double-click the Hydraulic Actuator subsystem to see the model
configuration.

6-23
6 Linearization and Trimming

The controller is represented as a continuous-time transfer function plus a transport


delay that allows for computational time and a zero-order hold when implemented in
discrete time. The Linearization I/O points subsystem lets you easily break and restore
the feedback control loop by setting the base workspace variable ClosedLoop to 0 or 1,
respectively.

The model is configured for linearization. You can quickly generate and view the small-
signal frequency response by clicking the Linearize hyperlink in model annotation. To
view the MATLAB script that generates the frequency response, click the next hyperlink
in that annotation, see code. This documentation provides background information and
alternative ways of linearization based on the software you have.

In general, to obtain a nontrivial linearized input-output model and generate a frequency


response, you must specify model-level inputs and outputs. The Hydraulic Actuator with
Digital Position Controller model meets this requirement in two ways, depending on how
you linearize:

• Simulink requires top- or model-level input and output ports for linearization with
linmod. The model has such ports, marked In1 and Out1.

6-24
Linearize a Plant Model for Use in Feedback Control Design

• Simulink Control Design software requires that you specify input and output signal
lines with linearization points. The specified lines must be Simulink signal lines, not
Simscape physical connection lines. The model has such linearization points specified.
For more information on using Simulink Control Design software for trimming and
linearization, see documentation for that product.

Open the Load Position scope and simulate the model in a normal closed-loop controller
configuration.

You can see that the model has a quasi-linear steady-state response between 2 and
3 seconds, when the two-way valve is open. Therefore, the state at 2.5 seconds is an
operating point suitable for linearization.

6-25
6 Linearization and Trimming

Trim Using the Controller and Linearize with Simulink linmod Function
1 Set the controller parameters.

To specify sample time for controller discrete-time implementation, type the


following in the MATLAB Command Window:

ts = 0.001;

To specify continuous-time controller numerator and denominator, type:

num = -0.5;
den = [1e-3 1];
2 Find an operating point by running closed-loop and selecting the state at 2.5 seconds
when the custom two-way valve is open.

To close the feedback loop, type:

assignin('base','ClosedLoop',1);

To simulate the model and save the operating point information in the form of a
state vector X and input vector U, type:

[t,x,y] = sim('ssc_hydraulic_actuator_digital_control');
idx = find(t>2.5,1);
X = x(idx,:); U = y(idx);
3 Linearize the model using the Simulink linmod function.

To break the feedback loop, type:

assignin('base','ClosedLoop',0);

To linearize the model, type:

[a,b,c,d] = linmod('ssc_hydraulic_actuator_digital_control',X,U);

Close the feedback loop by typing:

assignin('base','ClosedLoop',1);
4 To generate a Bode plot with negative feedback convention, type the following in the
MATLAB Command Window:

c = -c; d = -d;
6-26
Linearize a Plant Model for Use in Feedback Control Design

npts = 100; w = logspace(-3,5,npts); G = zeros(1,npts);


for i = 1:npts
G(i) = c*(1i*w(i)*eye(size(a))-a)^-1*b +d;
end
subplot(211), semilogx(w,20*log10(abs(G)))
grid
ylabel('Magnitude (dB)')
subplot(212), semilogx(w,180/pi*unwrap(angle(G)))
ylabel('Phase (degrees)')
xlabel('Frequency (rad/s)')
grid

Linearize with Simulink Control Design Software

Note: To work through this section, you must have a Simulink Control Design license.

6-27
6 Linearization and Trimming

Simulink Control Design software has tools that help you find operating points and
returns a state-space model object that defines state names. This is the recommended
way to linearize Simscape models.

1 In the top menu bar of the Hydraulic Actuator with Digital Position Controller
model, select Analysis > Control Design > Linear Analysis .
2 In the Linear Analysis Tool, in the Operating Point drop-down list, select
Linearize At. Enter simulation snapshot time of 2.5 seconds and click OK.
3 Click the Bode plot button.

For more information on using Simulink Control Design software for trimming and
linearization, see the Simulink Control Design documentation.

Related Examples
• “Linearize an Electronic Circuit” on page 6-13

6-28
Linearize a Plant Model for Use in Feedback Control Design

More About
• “Finding Operating Points in Physical Models” on page 6-3
• “Linearizing a Physical Model” on page 6-9

6-29
7

Real-Time Simulation

• “Model Preparation Objectives” on page 7-2


• “Real-Time Model Preparation Workflow” on page 7-5
• “Improving Speed and Accuracy” on page 7-10
• “Determine Step Size” on page 7-15
• “Reduce Computation Costs” on page 7-25
• “Reduce Numerical Stiffness” on page 7-31
• “Reduce Zero Crossings” on page 7-41
• “Fixed-Cost Simulation for Real-Time Viability” on page 7-55
• “Real-Time Simulation Workflow” on page 7-57
• “Solvers for Real-Time Simulation” on page 7-63
• “Determine System Stiffness” on page 7-68
• “Estimate Computation Costs” on page 7-76
• “Choose Step Size and Number of Iterations” on page 7-79
• “What Is Hardware-in-the-Loop Simulation?” on page 7-96
• “Hardware-in-the-Loop Simulation Workflow” on page 7-100
• “Code Generation Requirements” on page 7-106
• “Generate, Download, and Execute Code” on page 7-108
• “Requirements for Using Alternative Platforms” on page 7-111
7 Real-Time Simulation

Model Preparation Objectives


The main goal of model preparation is to ensure that your model is real-time capable.
Your model is real time capable if it is both:

• Accurate enough to generate simulation results that match your expectations, as


based on theoretical models and empirical data
• Fast enough to run on your real-time target machine without overruns

During model preparation, you obtain reference results and determine step size to assess
the likelihood that your model is real-time capable. If it is unlikely that your model is
real-time capable, you adjust the model scope or fidelity to make real-time simulation
with your model feasible.

Obtain Reference Results


Moving your model from desktop simulation to real-time simulation is an iterative
process that can require extensive model reconfiguration. During model preparation, you
obtain reference results from a variable-step simulation of your original model. These
results provide a baseline against which you can judge the accuracy of your modified
models.

Determine Step Size


In terms of speed, the only way to know if your model is real-time capable is to test for
overruns while simulating on real-time hardware. You can, however, analyze solver
execution speed using desktop simulation to determine if your model is probably fast
enough for real-time simulation. You do so by analyzing the steps of a variable-step
solver to find the maximum step size to use for sufficiently accurate real-time simulation
results. If the required step size appears small enough to cause an overrun on your real-
time hardware, you increase the step size by improving simulation speed.

Adjust Model Fidelity or Scope


You can adjust the fidelity or scope of your model to increase speed or accuracy.
Adjustments include:

• Deleting or adding blocks or modifying block parameters to eliminate or reduce


the effects of elements that introduce numerical stiffness or cause discontinuities.

7-2
Model Preparation Objectives

Simulations take small steps to calculate accurate solutions for these types of
elements.
• Modifying elements or parameters to increase simulation efficiency. For example,
simplify graphics that require excessive processing power or including lookup tables
instead of utilizing processing power to calculate known values.
• Partitioning independent networks of the model to enable parallel processing.

You can also adjust solver settings to help to make your model real-time capable. For
real-time simulation on target hardware, you use a fixed-step, fixed-cost solver that
bounds the computation cost, that is, the time the solver takes to execute each time
step. You configure the solver parameters before deploying it to a real-time target. The
fixed-step solver settings that you adjust to improve the real-time viability of your model
include step size, solver type, and number of iterations.

Due to the number of options, it is challenging to find the right combination of model
size, model fidelity, and solver parameters to achieve real-time simulation. The
relationship between speed and accuracy also makes it hard to find both system and
solver configurations that help to make your model real-time capable. If you increase
speed, you are likely to decrease accuracy. Conversely, increasing accuracy tends to
decrease speed. It is especially difficult to achieve acceptable speed and accuracy if you
try to adjust model fidelity and scope while you are changing fixed-step solver settings.
A better approach to find the optimal configuration is to change only one or two related
settings, analyze how those changes affect simulation speed and accuracy, and then
make other adjustments.

The real-time model preparation and the real-time simulation workflows separate the
configuration changes into two different step-wise processes. For the real-time model
preparation workflow, you adjust only the size or fidelity of your model and use variable-
step simulation to analyze the effects of your changes. For the real-time simulation
workflow, you adjust only the solver parameters and you use fixed-step, fixed-cost
simulation to analyze how the changes affect the speed and accuracy of your model.

Related Examples
• “Determine Step Size” on page 7-15
• “Reduce Computation Costs” on page 7-25
• “Reduce Numerical Stiffness” on page 7-31
• “Reduce Zero Crossings” on page 7-41

7-3
7 Real-Time Simulation

More About
• “Fixed-Cost Simulation for Real-Time Viability” on page 7-55
• “Improving Speed and Accuracy” on page 7-10
• “Real-Time Model Preparation Workflow” on page 7-5
• “Real-Time Simulation Workflow” on page 7-57

7-4
Real-Time Model Preparation Workflow

Real-Time Model Preparation Workflow


The figure shows the real-time model preparation workflow.

A real-time-capable model is both fast and accurate. When you simulate a real-time-
capable model on your real-time target, it runs to completion and generates results that
match your expectations, as based on theoretical models and empirical data. The only

7-5
7 Real-Time Simulation

way to determine if your model is real-time capable is to run it on your real-time target.
You can, however, use desktop simulation, that is, simulation on your development
computer, to determine the likelihood that your model is real-time capable before you
deploy it.

The real-time model preparation workflow is the first of two workflows that you perform
on your development computer to make it more probable that your model is real-time
capable. The workflow shows you how to adjust the size or fidelity of your model to
improve speed without sacrificing and accuracy. When you finish this workflow, use the
real-time simulation workflow to find the best fixed-step, fixed-cost solver configuration
to use for simulating your model in real time.

Prepare Your Model for Real-Time Simulation


Obtain Reference Results

Use empirical or theoretical data to design and build your Simscape model. Use a
Simulink global variable-step solver to simulate your model. Refine your model as
needed to obtain simulation results that the underlying data supports. Reference results
provide a baseline to assess model accuracy against throughout all stages of the model
preparation and real-time simulation workflows.

Evaluate Overrun Risk

An overrun occurs when the step size is too small to allow the real-time computer to
complete all the processing required for any one step. If your model requires a step size
that is so small that it is likely to cause an overrun, then your model is not fast enough
for real-time simulation. To determine if small steps are likely to cause an overrun,
create a plot of the size of the steps that the variable-step step solver uses to execute the
simulation of your model. The step size plot tells you the number and size of the small
steps that the solver uses during the simulation.

There are no hard metrics for the size or number of small steps that are likely to cause a
real-time-simulation overrun. Moving your model from desktop simulation to real-time
simulation is an iterative process. The process, which involves modifying, simulating,
and analyzing your model, helps you to determine if the small steps in your model are
time limiting or numerous enough to force an overrun.

Experience that you gain by simulating different models on your real-time machine
can also help you decide if the small steps in your model are likely to force an overrun.
For example, consider a case with two models, M1 and M2, and two different real-time

7-6
Real-Time Model Preparation Workflow

processors, RT1 and RT2. Processors RT1 and RT2 have the same nominal processing
speed. Models M1, a mechanical model, and M2, an electrical model, both have a few
steps that are 1e-15 seconds. It is possible for model M1 to simulate with sufficiently
accurate results on real-time processor RT1, but to incur an overrun or simulate with
insufficiently accurate results on real-time processor RT2. It is also possible that model
M1 runs to completion with accurate results on RT1 and RT2, whereas model M2
generates an overrun on both processors. These scenarios are possible because the
distinct model topologies yield different dynamics and because nominal processing speed
is not the only determinant for simulation execution time. Other factors such as the
operating system and I/O configuration also affect how simulation execution proceeds
on a real-time processor. Familiarity with system dynamics and the processing power of
your real-time equipment can guide your decision making when you assess the impact of
small step sizes on the real-time viability of a model.

Adjust Model Fidelity or Scope

Modify the model to increase speed or accuracy if your analysis indicates that real-time
simulation with the model is likely to have an overrun or yield insufficiently accurate
results.

When you evaluate overrun risk, if you find that the simulation uses too many small
steps, use these approaches to improve simulation speed:

• Reduce numerical stiffness.


• Reduce zero crossings.
• Reduce computation costs.
• Partition the model for parallel processing.

When you evaluate model accuracy, if you find that the simulation results do not match
the reference results, use these approaches to improve model accuracy:

• Simulink best practices for modeling dynamic systems


• Simscape essential modeling techniques

Obtain Results with a Variable-Step Solver

Using a Simulink global variable-step solver, obtain results for the modified version of
your model.

The step size plot also helps you to:

7-7
7 Real-Time Simulation

• Estimate the maximum step size to use for the fixed-step solver to achieve accurate
results during real-time simulation.
• Identify the exact times when discontinuities or fast dynamics slow down the
simulation.

Evaluate Model Accuracy

Compare the results from simulating on the target computer to your reference results.
Are the reference and modified model results the same? If not, are they similar enough
that the empirical or theoretical data also supports the results from the simulation of the
modified model? Is the modified model representing the phenomena that you want it to
measure? Is it representing those phenomena correctly? If you plan on using your model
to test your controller design, is the model accurate enough to produce results that you
can rely on for system qualification? The answers to these questions help you to decide if
your real-time results are accurate enough.

Perform Real-Time Simulation Workflow

When variable-simulation results indicate that your model has the speed and accuracy
required for real-time processing, you can use the “Real-Time Simulation Workflow” on
page 7-57 to configure your model for fixed-step, fixed-cost simulation.

Return to the Real-Time Model Preparation Workflow

The connector is an entry point for returning to the real-time model preparation
workflow from another workflow (for example, the real-time simulation workflow or the
hardware-in-the-loop simulation workflow).

Insufficient Computational Capability for Workflow Completion


It is possible that your real-time target lacks the computational capability for running
your model in real time. If, after multiple iterations of the workflow, it appears that there
is no level of model complexity that can make your model real-time capable, consider
these options for increasing processing power:

• “Upgrading Target Hardware” on page 7-13


• “Simulating Parts of the System in Parallel” on page 7-13

Related Examples
• “Determine Step Size” on page 7-15

7-8
Real-Time Model Preparation Workflow

• “Estimate Computation Costs” on page 7-76


• “Reduce Computation Costs” on page 7-25
• “Reduce Numerical Stiffness” on page 7-31
• “Reduce Zero Crossings” on page 7-41

More About
• “Essential Physical Modeling Techniques” on page 1-15
• “Hardware-in-the-Loop Simulation Workflow” on page 7-100
• “Improving Speed and Accuracy” on page 7-10
• “Model Preparation Objectives” on page 7-2
• “ Modeling Dynamic Systems”
• “Real-Time Simulation Workflow” on page 7-57

7-9
7 Real-Time Simulation

Improving Speed and Accuracy


In this section...
“Why Speed and Accuracy Matter for Real-Time Simulation” on page 7-10
“Balancing Speed and Accuracy” on page 7-11
“Eliminating Effects That Require Intensive Computation” on page 7-12
“Optimizing Local and Global Solver Configurations” on page 7-13
“Upgrading Target Hardware” on page 7-13
“Simulating Parts of the System in Parallel” on page 7-13

Why Speed and Accuracy Matter for Real-Time Simulation


Speed and accuracy are the determining factors for making your model real-time capable.
Your model is real-time capable if it satisfies both of these conditions when you simulate
it on your particular target hardware:

• There are no overruns.


• The simulation results meet your criteria for accuracy.

Speed is objective. The real-time clock determines Tether or not your model is fast
enough for real-time simulation. For each step that your solver takes, your real-time
hardware system tracks the time that it takes to complete these processing tasks:

• Execute the simulation.


• Process input and output.
• Perform general computer tasks

An overrun occurs when, for any time-step, the time that it takes your system to
complete the processing tasks exceeds the real-time limit for the tasks. If your target
machine reports any overruns when you use it to simulate your model, your model is not
fast enough for real-time simulation.

Your Simscape model is accurate if it produces results that agree with the empirical
and theoretical data that are the basis for your model. Accuracy is more subjective when
the foundation and simulation data are similar, but are not in absolute agreement. To
determine if your model is accurate enough for real-time simulation when the data do not
match perfectly, consider these questions:

7-10
Improving Speed and Accuracy

• Is the model representing the phenomena that you want it to measure?


• Is it representing those phenomena correctly?
• If you plan to use your model to test your controller design, is the model accurate
enough to produce results that you can rely on for system qualification?

The only way to test whether your model is real-time capable is to run it on your
actual real-time target hardware using fixed-step, fixed-cost solvers. You can, however,
estimate whether the model is both fast and accurate enough for real-time simulation by
analyzing the results from desktop simulation. To estimate whether your model is real-
time capable, see “Determine Step Size” on page 7-15 and “Estimate Computation
Costs” on page 7-76.

If the analysis from the desktop simulation indicates that your model likely is not real-
time capable, increase model speed or accuracy before deploying your model to your real-
time target. Increasing the speed of your simulation tends to decrease the accuracy, and
conversely increasing accuracy decreases speed. To make your model real-time capable,
maintain a balance between speed and accuracy.

Balancing Speed and Accuracy


Simulation speed and accuracy correlate to your choices for:

• Model fidelity and scope


• Real-time hardware computing power
• Solver sample time (step size) and number of iterations

To try to increase simulation speed, potentially at the expense of accuracy:

• Decrease model fidelity or scope.


• Increase sample time.
• Decrease the number of solver iterations.

To try to increase simulation accuracy, potentially at the expense of speed:

• Increase model fidelity or scope.


• Decrease sample time.
• Increase the number of solver iterations.

7-11
7 Real-Time Simulation

To try to increase both accuracy and speed, or either one without sacrificing the other,
increase computing power. To increase computing power, use a faster real-time processor
or compute in parallel.

The type of solver that you specify also affects simulation speed and accuracy. For fixed-
step simulation, Simscape local solvers are faster and as accurate as Simulink global
solvers. Implicit solvers are faster, but less accurate than explicit solvers. However, the
numerical stiffness of the network is also a determinant for deciding whether to use
an implicit solver or an explicit solver. Explicit solvers yield more accurate results for
numerically stiff networks.

For more information on how model complexity affects speed and accuracy, see
“Eliminating Effects That Require Intensive Computation” on page 7-12. For more
information, on how solver configurations affect speed and accuracy, see “Optimizing
Local and Global Solver Configurations” on page 7-13.

It is possible that there is no combination of model complexity and solver settings that
can make your model real-time capable. If the simulation does not run in real time on the
target, or if the accuracy is unacceptable, consider these options for increasing speed and
accuracy:

• “Upgrading Target Hardware” on page 7-13


• “Simulating Parts of the System in Parallel” on page 7-13

Eliminating Effects That Require Intensive Computation


If your desktop simulation analysis indicates that your model likely is not fast enough
for real-time simulation, eliminate effects that require intensive computation. Identify
elements in your model that cause costly effects, such as discontinuities and rapid
changes, that tend to slow down simulations.

Elements that cause discontinuities include:

• Hard stops or backlash


• Stick-slip friction
• Switches or clutches

Elements with small time constants that cause rapid changes include:

• Small masses attached to stiff springs with minimal damping

7-12
Improving Speed and Accuracy

• Electrical circuits with low capacitance, inductance, and resistance


• Hydraulic circuits with small compressible volumes

To eliminate or modify the elements that are responsible for the effects that slow down
your simulation, use these approaches:

• Replace nonlinear components with linearized versions.


• Replace complex equations with lookup tables for their solution.
• Replace complicated components with simplified models.
• Smooth discontinuous functions (step changes) with filters, delays, and other
techniques.

Optimizing Local and Global Solver Configurations


You can also influence the speed and accuracy of your simulation by way of your
solver specifications. The level of accuracy that your real-time target delivers does not
necessarily correlate to a specific step size across all networks in a single model. A real-
time target can give accurate results for a simple network in your model but inaccurate
results for a more complex network. Take advantage of the ability to specify different
solver configurations for each network in your Simscape model. To help make your
model real-time capable, configure your fixed-step global solver and each local solver
individually.

For information on solver options and determining the solvers that help to make your
Simscape model real-time capable, see “Solvers for Real-Time Simulation” on page
7-63.

Upgrading Target Hardware


Different targets give varying levels of accuracy when using the same step size to
simulate the same model. You can speed up or increase the accuracy of the real-time
simulation by using a faster real-time target computer.

Simulating Parts of the System in Parallel


Another approach for increasing speed while maintaining accuracy is to configure your
model to evaluate multiple physical networks in parallel. You can partition your model if

7-13
7 Real-Time Simulation

the networks are not dependent upon one another. Work with and experiment with your
model, the generated code, and the real-time target to use this approach.

Related Examples
• “Determine Step Size” on page 7-15
• “Estimate Computation Costs” on page 7-76
• “Reduce Computation Costs” on page 7-25
• “Reduce Numerical Stiffness” on page 7-31
• “Reduce Zero Crossings” on page 7-41

More About
• “Model Preparation Objectives” on page 7-2
• “Real-Time Model Preparation Workflow” on page 7-5
• “Solvers for Real-Time Simulation” on page 7-63

7-14
Determine Step Size

Determine Step Size


For the first step in “Real-Time Model Preparation Workflow” on page 7-5, you obtain
results from a variable-step simulation of the reference version of your Simscape model.
The reference results provide a baseline against which you can assess the accuracy of
your model as you modify it. This example shows how to analyze the reference results
and the step size that the variable-step solver takes to:

• Estimate the maximum step size that you can use for a fixed-step simulation
• Identify events that have the potential to limit the maximum step size

Discontinuities and rapid changes require small step sizes for accurately capturing these
dynamics. The maximum step size that you can use for a fixed-step simulation must be
small enough to ensure accurate results. If your model contains such dynamics, then it is
possible that the required step size for accurate results, Tsmax, is too small to allow your
real-time computer to finish calculating the solution for any given step in the simulation.

The analysis in this example helps you to estimate the maximum step size that fixed-
step solvers can use and still obtain accurate results. You can also use the analysis
to determine which elements influence the maximum possible step size for accurate
results. For more information on how obtaining reference results and performing a
step-size analysis helps you to prepare your model for real-time simulation, see “Model
Preparation Objectives” on page 7-2.

1 To open the reference model, at the MATLAB command prompt, enter:

ssc_pneumatic_rts_reference

7-15
7 Real-Time Simulation

2 Simulate the model.


3 Create a semilogarithmic plot that shows how the step size for the solver varies
during the simulation.

h1 = figure;
semilogy(tout(1:end-1),diff(tout),'-x')
title('Solver Step Size');
xlabel('Time (s)');
ylabel('Step Size (s)');

7-16
Determine Step Size

For much of the simulation, the step size is greater than the value of the Tsmax in
the plot. The corresponding value, ~0.001 seconds, is an estimated maximum step
size for achieving accurate results during fixed-step simulation with the model. To
see how to configure the step size for fixed-step solvers for real-time simulation, see
“Choose Step Size and Number of Iterations” on page 7-79.

The x markers in the plot indicate the time that the solver took to execute a single
step at that moment in the simulation. The step-size data is discrete. The line that
connects the discrete points exists only to help you see the order of the individual
execution times over the course of the simulation.

7-17
7 Real-Time Simulation

A large decrease in step size indicates that the solver detects a zero-crossing event.
Zero-crossing detection can happen when the value of a signal changes sign or
crosses a threshold. The simulation reduces the step size to capture the dynamics
for the zero-crossing event accurately. After the solver processes the dynamics for a
zero-crossing event, the simulation step size can increase. It is possible for the solver
to take several small steps before returning to the step size that precedes the zero-
crossing event. The areas in the red boxes contain variations in recovery time for the
variable step solver.
4 To see different post-zero-crossing behaviors, zoom to the region in the red box at
time (t) = ~1 second.

h1;
xStart = 0; xEnd = 10; yStart = 0; yEnd = 10e0;
xZoomStart1 = 0.99; xZoomEnd1 = 1.06;
yZoomStart1 = 10e-20; yZoomEnd1 = 10e-1;
axis([xZoomStart1 xZoomEnd1 yZoomStart1 yZoomEnd1]);

7-18
Determine Step Size

Between t = 0 and 1 second, the solver takes a step every 0.01 seconds. The step size
decreases to less than 10e-10 seconds to capture an event that occurs one second into
the simulation. The step size increases quickly to 10e-5 seconds, and then increases
slowly to the step size from before the event. The slow rate of recovery indicates
that the simulation is using small steps to capture the dynamics of elements in your
model. If the required step size limits the maximum fixed-step size to a small enough
value, then an overrun might occur when you attempt simulation on your real-time
computer.

The types of elements that require small step size are:

• Elements that cause discontinuities, such as hard-stops and stick-slip friction

7-19
7 Real-Time Simulation

• Elements that have small time constants, such as small masses with undamped,
stiff springs and hydraulic circuits with small, compressible volumes

The step size recovers more quickly after it slows down to process events that occur
between the simulation times where t = 1.02 and 1.06 seconds. The events that occur
during this time are less likely to require small step sizes to achieve accurate results.
5 To see different types of slow solver recoveries, zoom to the region within the red box
at t = ~4.2 seconds.

h1;
xZoomStart2 = 4.16; xZoomEnd2 = 4.24;
yZoomStart2 = 10e-20; yZoomEnd2 = 10e-1;
axis([xZoomStart2 xZoomEnd2 yZoomStart2 yZoomEnd2]);

7-20
Determine Step Size

Just as there are different types of events that cause solvers to slow down, there are
different types of slow solver recovery. The events that occur just before t = 4.19 and
4.2 seconds both involve zero-crossings. The solver takes a series of progressively
larger steps as it reaches the step size from before the event. The large number of
very small steps that follow the zero crossing at Slow Recovery A indicate that the
element that caused the zero crossing is also numerically stiff.

The quicker step-size increase after the event that occurs at t = 4.2 seconds indicates
that the element that caused the zero crossing before Slow Recovery B, is not as stiff
as the event at Slow Recovery A.
6 To see the results, open the Simscape Results Explorer.

7-21
7 Real-Time Simulation

sscexplore(simlog)
7 In the Simscape Results Explorer window, in the simulation log tree hierarchy,
expand the Measurements node and the Ideal_Rotational_Motion_Sensor
node. Select the w Plot to see the plot for angular speed.

8 To add the gas flow results to the Simscape Results Explorer window, expand the
Measure_Flow node and the Pneumatic_Mass_Heat_Flow_Sensor node. Use Ctrl
+click to select both the G_ps Plot and the w Plot .

7-22
Determine Step Size

The slow recovery times occur when the simulation initializes, and approximately at
t = 1, 4, 5, 8, and 9 seconds. These periods of small steps coincide with these times:

• The motor speed is near zero rpm (simulation time t = ~ 1, 5, and 9 seconds)
• The step change in motor speed is initiated from a steady-state speed to a new
speed (time t = ~ 4 and 8 seconds)
• The step change in flow rate is initiated from a steady-state speed to a new flow
rate (time t = ~ 4 and 8 seconds)
• The volumetric flow rate is near zero m^3/min (t = ~ 1, 4, and 5 seconds)

7-23
7 Real-Time Simulation

These results indicate that the slow step-size recoveries are most likely due to
elements in the model that involve friction or that have small, compressible volumes.
To see how to identify the problematic elements and modify them to increase
simulation speed, see “Reduce Numerical Stiffness” on page 7-31 and “Reduce
Zero Crossings” on page 7-41.

Related Examples
• “Choose Step Size and Number of Iterations” on page 7-79
• “Reduce Numerical Stiffness” on page 7-31
• “Reduce Zero Crossings” on page 7-41

More About
• “About Simulation Data Logging” on page 9-2
• “Events and Zero Crossings” on page 4-3
• “Improving Speed and Accuracy” on page 7-10
• “Log and View Simulation Data for Selected Blocks” on page 9-17
• “Model Preparation Objectives” on page 7-2
• “Real-Time Model Preparation Workflow” on page 7-5
• “Real-Time Simulation Workflow” on page 7-57
• “Solvers for Real-Time Simulation” on page 7-63
• “Stiffness” on page 4-3
• “Zero-Crossing Detection”

7-24
Reduce Computation Costs

Reduce Computation Costs


In this section...
“Data Logging and Monitoring Guidelines” on page 7-25
“Improve Data Logging and Monitoring Efficiency” on page 7-25
“Additional Methods for Reducing Computational Cost” on page 7-29

Computational cost is a measure of the number and the complexity of tasks that a
processor performs per time step during a simulation. Lowering the computational cost of
your model increases simulation execution speed and helps you to avoid overruns when
you simulate in real time on target hardware.

Data Logging and Monitoring Guidelines


Data logging and monitoring are interactive procedures that consume memory and
processing power. One way to reduce computational cost is to reduce the amount
of interactive processing that occurs during simulation. Best practices for limiting
computational costs while logging and monitoring data are:

• Use an outport block only if you need to log data for your analysis via the Simulink
model on your development computer.
• Use a scope block only if you need to monitor data during real-time simulation via the
Simulink model on your development computer.
• If you need to log data or monitor a variable, limit the number or the decimation of
data points that you collect whenever your analysis requirements permit you to do so.
• Log data only once.
• If you use Simscape data logging, use local settings to log only the blocks that contain
variables that you need for your analysis.

Note: Simscape simulation data logging is not supported for generated code.

Improve Data Logging and Monitoring Efficiency


Examine the configuration of the model and the simulation results to determine if the
model is logging and monitoring data efficiently.

7-25
7 Real-Time Simulation

1 To open the model, at the MATLAB command prompt, enter:

ssc_pneumatic_rts_zc_redux

The model contains three scope blocks and one outport block. The Power (kW) scope,
RPM scope and outport block receive data from the Measurements subsystem.
2 Simulate the model.

The model logs five variables to the workspace, including a Simscape simulation
data logging node.

7-26
Reduce Computation Costs

3 To determine the source for the Pneu_rts_RPM_DATA, In the MATLAB workspace,


open the structure.

The blockName variable shows that the RPM scope logs the data. In the model, the
outport that logs data to yout connects to the signal between the Measurements
subsystem and the RPM scope block.
4 To compare the data that Pneu_rts_RPM_DATA and yout log, plot both data sets to
a single figure.

h1 = figure;
plot(tout,yout);
h1;
hold on;
plot(Pneu_rts_RPM_DATA.time,Pneu_rts_RPM_DATA.signals.values,'r--');
title('Speed');
xlabel('Time (s)');
ylabel('Speed (rpm)');
h1Leg = legend({'yout','Pneu-rts-RPM-DATA'});

7-27
7 Real-Time Simulation

The data is the same, which means that you are logging the same data twice.

To reduce the computational cost for logging or monitoring the speed data via the
Simulink model on your development computer during real-time simulation:

• If you only need to log the speed data, delete the RPM scope block.
• If you need to log and monitor the speed data, delete the outport block.
• If you only need to monitor the speed data, delete the outport block and disable data
logging for the RPM scope.

7-28
Reduce Computation Costs

If you do not need to log or monitor the speed data via the Simulink model on your
development computer during real-time simulation with target hardware, delete both the
RPM scope block and the outport block.

If you want to reduce costs by deleting the scope and outport blocks, but you need to
log data while you prepare your model for real-time simulation, configure the model to
log only the data that you need with the simlog node in the MATLAB workspace. For
information, see “Log Data for Selected Blocks Only” on page 9-5.

Additional Methods for Reducing Computational Cost


In addition to reducing the number of logged and monitored signals, you can use these
methods for decreasing the number and complexity of tasks that the processor performs
per time step during simulation:

• Avoid using large images and complex graphics.


• Disable unnecessary error and warning diagnostics.
• Reconfigure tolerances.
• Simplify complex subsystems or replace them with lookup tables.
• Linearize nonlinear effects.
• Eliminate redundant calculations, for example, multiplication by one.
• Reduce the number of differential algebraic equations (DAEs).

Related Examples
• “Determine Step Size” on page 7-15
• “Estimate Computation Costs” on page 7-76
• “Reduce Numerical Stiffness” on page 7-31
• “Reduce Zero Crossings” on page 7-41

More About
• “About Simulation Data Logging” on page 9-2
• “Limitations” on page 9-3
• “Improving Speed and Accuracy” on page 7-10
• “Log, Navigate, and Plot Simulation Data” on page 9-21

7-29
7 Real-Time Simulation

• “Model Preparation Objectives” on page 7-2


• “Real-Time Model Preparation Workflow” on page 7-5
• “Real-Time Simulation Workflow” on page 7-57

7-30
Reduce Numerical Stiffness

Reduce Numerical Stiffness


This example helps you to complete the steps outlined in “Real-Time Model Preparation
Workflow” on page 7-5 and to meet the goals described in “Model Preparation Objectives”
on page 7-2.

In “Determine Step Size” on page 7-15, you use the results of a variable-step simulation
of your Simscape model to identify when step size decreases to capture behavior
accurately at discontinuities and for rapid dynamics in numerically stiff systems. These
types of events often require solvers to take steps that are too small to support real-time
simulation. This example shows how to use the results from “Determine Step Size” on
page 7-15 to identify a numerically stiff element in your model. It also shows how to
modify the element for faster simulation without sacrificing accuracy.

Why Reduce Stiffness?


Numerical stiffness can prevent your model from being real-time capable. A real-time-
capable model is one that produces acceptable results without incurring overruns when
you simulate it on your target processor. Stiff systems contain dynamics that vary both
quickly and slowly. When solvers take large steps, they usually capture slowly changing
dynamics, but they tend to miss rapid changes unless they are taking small steps. Small
step sizes cause overruns when they do not provide enough time for a real-time computer
to complete calculating solutions during a single step.

To you reduce numerical stiffness, you eliminate rapid changes. If there are no rapid
changes, the solver can take larger steps and still obtain accurate simulation results. The
larger the step size, the less likely it is that your model generates an overrun during real-
time simulation.

Review Reference Results


1 To open the model, at the MATLAB command prompt, enter:

ssc_pneumatic_rts_reference

7-31
7 Real-Time Simulation

2 Simulate the model.


3 Create a figure that contains a semilogarithmic plot of the solver step size, a plot of
the motor speed results, and a plot of the gas flow results.

h1 = figure;
subplot(3,1,1)
semilogy(tout(1:end-1),diff(tout),'-x')
title('Solver Step Size and Results');
ylabel('Step Size (s)');
subplot(3,1,2)
plot(tout,Pneu_rts_RPM_DATA.signals.values);
ylabel('Speed (rpms)');
subplot(3,1,3);
plot(tout,Pneu_rts_Vol_Flow_DATA.signals.values);
xlabel('Time (s)');
ylabel('Flow Rate (m^3/min)');

7-32
Reduce Numerical Stiffness

The simulation takes steps smaller than 1e-10 seconds when:

• The motor speed is near zero rpm (simulation time t = ~ 1, 5, and 9 seconds)
• The step change in motor speed is initiated from a steady-state speed to a new
speed (time t = ~ 4 and 8 seconds)
• The step change in flow rate is initiated from a steady-state speed to a new flow
rate (time t = ~ 4 and 8 seconds)
• The volumetric flow rate is near zero m^3/min (t = ~ 1, 4, and 5 seconds)

The results indicate that small step sizes are required to achieve accuracy when
the simulation is capturing dynamics that involve friction or small, compressible

7-33
7 Real-Time Simulation

volumes. Elements that generate zero crossings might also be responsible for the
small steps and slow recovery times.
4 Assign the simulation results to new variables in the MATLAB workspace so that
you can compare the data to results from a model that you modify.

timeRef = tout;
simlogRef = simlog;

Identify and Modify a Stiff Element


Examine the friction load in the model to determine if it incorporates discontinuities or
has a small time constant that causes numerical stiffness. Modify the element if it causes
any rapidly changing dynamics that require a small step size.

1 Save the model as rts_stiffness_model in a writable folder on the MATLAB


path.
2 Open the Friction Load block dialog box, a Rotational Friction block. The figure
shows the friction torque/relative velocity characteristic for the simple approximation
of continuous friction that the block models.

7-34
Reduce Numerical Stiffness

The breakaway torque is modeled as a function of the velocity threshold. When


velocity is close to zero, a small change in velocity yields a large change in torque.
When velocity is not close to zero, the torque change is more gradual. This block
represents a stiff element. To make the element less stiff, specify a value for the
Linear region velocity threshold that is not close to zero.
3 On the Parameters tab of the dialog box, change the value of the Linear region
velocity threshold from .005 to .5 rad/s.

7-35
7 Real-Time Simulation

4 Simulate the modified model.

Analyze Results
To see how modifying the velocity threshold for the friction block affects the stiffness
of the component, compare the step sizes for the two simulations. The reference results
meet expectations based on empirical and theoretical data. You can assess the accuracy
of the modified model by comparing the speed results from the modified model to those
from the original version of the model.

1 Plot the step size for the reference results for modified model to the figure that
contains the reference data.

h2 = figure;
semilogy(timeRef (1:end-1),diff(timeRef),'-x',...
'LineWidth',1,'MarkerSize',7);
hold on;
semilogy(tout(1:end-1),diff(tout),'--x','Color','r',...
'LineWidth',.1,'MarkerSize',5);
title('Solver Step Size');
xlabel('Time (s)');
ylabel('Step Size (s)');
h1Leg = legend({'Reference','Modified'},'Location','best');

7-36
Reduce Numerical Stiffness

The step size recovers more quickly from events that occur at simulation time t = ~4,
5, 8, and 9 seconds. The simulation is less stiff at these times.
2 Extract the speed and time data from the logging nodes for the original and modified
models.

speedRefNode = simlogRef.Measurements.Ideal_Rotational_Motion_Sensor.R.w;
speedRef = speedRefNode.series.values ('rpm');
timeRef = speedRefNode.series.time;
speedModNode = simlog.Measurements.Ideal_Rotational_Motion_Sensor.R.w;
speedMod = speedModNode.series.values ('rpm');
timeMod = speedModNode.series.time;

7-37
7 Real-Time Simulation

3 Plot and compare the results for the speed data for both simulations to make sure
that the modified model is accurate.

h3 = figure;
plot(timeRef,speedRef)
h3;
hold on;
plot(timeMod,speedMod,'r--');
title('Speed');
xlabel('Time (s)');
ylabel('Speed (rpms)');
h3Leg = legend({'Reference','Modified'},'Location','best');

4 Zoom for a closer look at the inflection point at time (t) = ~5 seconds.

7-38
Reduce Numerical Stiffness

h3;
xStart = 0; xEnd = 10; yStart =-4000; yEnd = 4000;
xZoomStart1 = 4.8; xZoomEnd1 = 5.2;
yZoomStart1 = -400; yZoomEnd1 = 150;
axis([xZoomStart1 xZoomEnd1 yZoomStart1 yZoomEnd1]);

At this zoom level, you can see a small difference in the results, but the simulation
results for the modified model are accurate enough to meet expectations based on
empirical and theoretical data.

The Friction Load is now less numerically stiff. The figure of step size during simulation
shows that other elements in the model are also responsible for slow recovery times.

7-39
7 Real-Time Simulation

Reduce more slow-recovery steps by examining and modifying the other elements that
cause stiffness.

You can also increase speed by modifying the model using methods in “Reduce
Computation Costs” on page 7-25 and “Reduce Zero Crossings” on page 7-41. If you
can eliminate all small steps that might generate an overrun, you can attempt to run a
fixed-step simulation using the methods in “Choose Step Size and Number of Iterations”
on page 7-79.

See Also
Rotational Friction

Related Examples
• “Determine Step Size” on page 7-15
• “Estimate Computation Costs” on page 7-76
• “Reduce Computation Costs” on page 7-25
• “Reduce Zero Crossings” on page 7-41

More About
• “About Simulation Data Logging” on page 9-2
• “Events and Zero Crossings” on page 4-3
• “Log and Plot Simulation Data” on page 9-8
• “Model Preparation Objectives” on page 7-2
• “Real-Time Model Preparation Workflow” on page 7-5
• “Stiffness” on page 4-3

7-40
Reduce Zero Crossings

Reduce Zero Crossings


In this section...
“Why Reduce Zero Crossings?” on page 7-41
“Obtain Reference Results and Plot Simulation Step Size” on page 7-41
“Identify and Modify Elements That Cause Zero Crossings” on page 7-45
“Analyze the Results of the Modified Model” on page 7-50

Why Reduce Zero Crossings?


Real-time deployment requires using a fixed-step solver. You might want to run the same
model using a variable-step solver for desktop simulation. Variable-step solvers take
smaller steps when they detect a zero-crossing event. Smaller steps help to capture the
dynamics that cause the zero crossing accurately. Fixed-step solvers do not vary the size
of the steps that they take. If your model relies heavily on detecting zero crossings, you
might need to specify a very small fixed-step size to capture the dynamics accurately. A
small step size can lead to overruns during real-time simulation. By reducing the number
of zero crossings, you can configure your solver to use a larger step size for both variable-
step and fixed-step deployment while generating results that are accurate enough.

Obtain Reference Results and Plot Simulation Step Size


Simulate your model to generate data that you can use to:

• Decide which model elements to change to reduce the number of zero-crossing events.
• Assess the accuracy of your modified model.

1 To open the model, at the MATLAB command prompt, enter:

ssc_pneumatic_rts_stiffness_redux
2 Simulate the model.
3 Save the data to the workspace.

simlogRef = simlog;
timeRef = tout;
4 Plot the step size against the simulation time.

h1 = figure;

7-41
7 Real-Time Simulation

semilogy(timeRef(1:end-1),diff(timeRef),'-x')
title('Solver Step Size');
xlabel('Time (s)');
ylabel('Step Size (s)');

The simulation slows down repeatedly at the beginning of the simulation and at time
t = ~4, 5, 8, and 9 seconds.
5 Zoom to examine the data between time t = 0.4 and 0.8 seconds.

h1;
xStart = 0; xEnd = 10; yStart = 0; yEnd = 10e0;
xZoomStart1 = 0.4; xZoomEnd1 = 0.8;
yZoomStart1 = 10e-20; yZoomEnd1 = 10e-1;

7-42
Reduce Zero Crossings

axis([xZoomStart1 xZoomEnd1 yZoomStart1 yZoomEnd1]);

The blue x markers in the figure indicate that the simulation has completed
executing a step. The circled markers indicate a very small step size and represent
zero-crossing events. The step size decreases to approximately 10e-15 seconds for
each zero-crossing detection.
6 To obtain the reference results for motor speed, open the Measurements subsystem.
Select the Ideal Rotational Motion Sensor block. With the block selected, use the
simscape.logging.sli.findNode function to find and save the node that
contains the data for W, the signal for the angular velocity of the motor.

nRef = simscape.logging.sli.findNode(simlogRef,gcbh)

7-43
7 Real-Time Simulation

nRef =

Node with properties:

id: 'Ideal_Rotational_Motion_Sensor'
w: [1x1 simscape.logging.Node]
phi: [1x1 simscape.logging.Node]
R: [1x1 simscape.logging.Node]
W: [1x1 simscape.logging.Node]
t: [1x1 simscape.logging.Node]
A: [1x1 simscape.logging.Node]
C: [1x1 simscape.logging.Node]
7 Use the simscape.logging.plot function to plot the reference results for W.

simscape.logging.plot(nRef.W);

7-44
Reduce Zero Crossings

Identify and Modify Elements That Cause Zero Crossings


Analyze the simulation data to determine the elements responsible for the zero crossings.
Modify the model to reduce the number of zero crossings that those elements cause.

1 Use the Simscape sscprintzcs function to print zero-crossing information for


logged simulation data.

sscprintzcs(simlogRef)

ssc_pneumatic_rts_stiffness_redux (155 signals, 101 crossings)


+-Directional_5_way_valve (144 signals, 36 crossings)

7-45
7 Real-Time Simulation

| +-Area_A_R (12 signals, 2 crossings)


| +-Area_B_S (12 signals, 2 crossings)
| +-Area_P_A (12 signals, 2 crossings)
| +-Area_P_B (12 signals, 2 crossings)
| +-Variable_Area_Orifice_1 (24 signals, 6 crossings)
| +-Variable_Area_Orifice_2 (24 signals, 8 crossings)
| +-Variable_Area_Orifice_3 (24 signals, 8 crossings)
| +-Variable_Area_Orifice_4 (24 signals, 6 crossings)
+-Friction_Load (2 signals, 4 crossings)
+-Pipe_1 (2 signals, 0 crossings)
| +-Constant_Chamber (2 signals, 0 crossings)
+-Pipe_2 (2 signals, 0 crossings)
| +-Constant_Chamber (2 signals, 0 crossings)
+-Pneumatic_Motor (5 signals, 61 crossings)
The results show that many of the 101 detected zero crossings occur in the
Directional 5-way valve block (36 crossings) and the Pneumatic Motor block (61
crossings).
2 Use the sscexplore function to open the Simscape Results Explorer to interact
with logged simulation data.

sscexplore(simlogRef)
3 In the results tree, select the Pneumatic_Motor node to see the results for the
motor.

7-46
Reduce Zero Crossings

7-47
7 Real-Time Simulation

Most of the zero crossings occur between t = 0 and t =1 seconds, when the other
signals in the block are near zero. The few remaining zero crossings occur at t = 5
and 10 seconds.
4 To identify the source code that triggers most of the zero crossings, expand the
Pneumatic_Motor node and the SimulationsStatistics (ZeroCrossings)
node. Click the zc_0 - 43 crossings Zero Crossing button and then the
PneumaticMotor.PneumaticMotor link that appears in the lower, left corner of
the window.

7-48
Reduce Zero Crossings

The source code for the Pneumatic Motor block opens with the cursor at this code:

% Flow direction - "dir" is positive if flow is from port A to port B, otherwise ne


dir = if A.p>B.p, 1 else -1 end;

The conditional statement that is responsible for the zero crossings is related to
the flow direction in the pipe blocks. The Pipe 1 and Pipe 2 blocks simply model

7-49
7 Real-Time Simulation

pneumatic pipes with constant parameters. The Directional 5-way valve block feeds
the pipe blocks.
5 Look under the mask of the valve block. The spool position dictates the orifice that
receives the gas flow, and therefore, the direction of flow in the pipes that lead to the
motor.
6 Open the Signal Builder block that determines the spool position. Between the
simulation time, t, of 0 and 1 second, the signal puts the spool at position 0. The zero
crossings reflect the chatter that occurs as the system fills.
7 Decrease the chatter, and therefore the number of zero crossings, by increasing the
leakage area of the Directional 5-way valve. Open the Directional 5-way valve block
dialog box and specify 1e-2 for the Leakage area at x=0 (mm^2).

Analyze the Results of the Modified Model


Compare the results to the reference results to ensure the accuracy of your modified
model. Confirm that your modified model has fewer zero crossings.

1 Simulate the model.


2 Print the zero crossing data.

sscprintzcs(simlog)

ssc_pneumatic_rts_stiffness_redux (155 signals, 65 crossings)


+-Directional_5_way_valve (144 signals, 28 crossings)
| +-Area_A_R (12 signals, 2 crossings)
| +-Area_B_S (12 signals, 2 crossings)
| +-Area_P_A (12 signals, 2 crossings)
| +-Area_P_B (12 signals, 2 crossings)
| +-Variable_Area_Orifice_1 (24 signals, 4 crossings)
| +-Variable_Area_Orifice_2 (24 signals, 6 crossings)
| +-Variable_Area_Orifice_3 (24 signals, 6 crossings)
| +-Variable_Area_Orifice_4 (24 signals, 4 crossings)
+-Friction_Load (2 signals, 4 crossings)
+-Pipe_1 (2 signals, 0 crossings)
| +-Constant_Chamber (2 signals, 0 crossings)
+-Pipe_2 (2 signals, 0 crossings)
| +-Constant_Chamber (2 signals, 0 crossings)
+-Pneumatic_Motor (5 signals, 33 crossings)

The overall number of zero crossings has decreased from 101 to 65. The number of
zero crossings in the motor has decreased from 50 to 33.

7-50
Reduce Zero Crossings

3 To compare the results, use the simscape.logging.plot function to plot the


reference results and the results from the modified model to a single plot.

simscape.logging.plot...
({simlogRef.Measurements.Ideal_Rotational_Motion_Sensor.W...
simlog.Measurements.Ideal_Rotational_Motion_Sensor.W}, ...
'names', {'Reference','Modified'});

The results look the same.


4 Zoom control for a closer look at the inflection point at t = ~ 5 seconds.

xStart = 0; xEnd = 10; yStart = -400; yEnd = 400;


xZoomStart1 = .9; xZoomEnd1 = 1.6;

7-51
7 Real-Time Simulation

yZoomStart1 = -20; yZoomEnd1 = 220;


axis([xZoomStart1 xZoomEnd1 yZoomStart1 yZoomEnd1]);

At this zoom level, you can see a small difference in the results for the modified
model. However the simulation is accurate enough that the results meet
expectations based on empirical and theoretical data.
5 Examine the step size for the simulation with the modified model.

h1;
axis([xStart xEnd yStart yEnd]);
h1;
hold on;
semilogy(tout(1:end-1),diff(tout),'--x', 'Color','r',...

7-52
Reduce Zero Crossings

'LineWidth',.1,'MarkerSize',5);
title('Solver Step Size');
xlabel('Time (s)');
ylabel('Step Size (s)');
h1Leg2 = legend({'Reference','Modified'},[300,65,0.3,0.7]);

You have reduced the number of zero crossings by eliminating most of the chatter
at the beginning of the simulation. Events still slow the simulation at t = ~1, 4, 5, 8,
and 9 seconds. To improve simulation speed further before performing the real-time
simulation workflow with this model, try:

• Repeating the method shown in this example to identify and adjust other
elements that cause zero crossings that are responsible for the small steps

7-53
7 Real-Time Simulation

• Reducing any numerical stiffness that is responsible for the small steps

See Also
simscape.logging.plotxy | simscape.logging.sli.findNode | sscexplore |
sscprintzcs

Related Examples
• “Determine Step Size” on page 7-15
• “Estimate Computation Costs” on page 7-76
• “Improving Speed and Accuracy” on page 7-10
• “Log, Navigate, and Plot Simulation Data” on page 9-21
• “Reduce Computation Costs” on page 7-25
• “Reduce Numerical Stiffness” on page 7-31

More About
• “About Simulation Data Logging” on page 9-2
• “About the Simscape Results Explorer” on page 9-26
• “Events and Zero Crossings” on page 4-3
• “Model Preparation Objectives” on page 7-2
• “Improving Speed and Accuracy” on page 7-10
• “Real-Time Model Preparation Workflow” on page 7-5
• “Using Conditional Expressions in Equations”
• “Zero-Crossing Detection”

7-54
Fixed-Cost Simulation for Real-Time Viability

Fixed-Cost Simulation for Real-Time Viability


The step size and number of iterations that you specify affect the computational cost
of your real-time simulation. As you decrease the step size or increase the number of
iterations, the results become more accurate, but the simulation costs more so it can
take longer to simulate. Simulation overrun occurs if the step size is too small or if
there are too many iterations for the solver to calculate a solution in a single real-time
computational frame.

Limit the computational cost by specifying the solver step size and, for implicit solvers,
the number of iterations for the Simulink global solver and for each Simscape local solver
in your model.

For best results when specifying the step size of a fixed-step solver for real-time
simulation:

• Specify a sample time that results in time steps that are no greater than the
maximum step size.
• Specify the sample time for each local solver independently and as an integer multiple
of the sample time that you specify for the global solver.
• Choose a step size that is larger than the minimum step size for required speed and
smaller than the maximum step size for required accuracy.

To configure the number of iterations for real-time simulation with a fixed-step solver:

• For local solvers, specify the number of nonlinear iterations for each independently
configured Solver Configuration block.
• For global solver ode14x, specify the number of Newton’s iterations.

To obtain accurate results, for both local and global solvers start with two or three
iterations and increase as required.

Related Examples
• “Choose Step Size and Number of Iterations” on page 7-79

More About
• “Simulating with Fixed Cost” on page 4-22
• “Simulating with Fixed Time Step — Local and Global Fixed-Step Solvers” on page
4-21

7-55
7 Real-Time Simulation

• “Solvers for Real-Time Simulation” on page 7-63

7-56
Real-Time Simulation Workflow

Real-Time Simulation Workflow


The figure shows the real-time simulation workflow. The connectors are exit points for
returning to the real-time model preparation workflow.

7-57
7 Real-Time Simulation

7-58
Real-Time Simulation Workflow

The figure shows the real-time model preparation workflow. The connector is an entry
point for returning to the real-time model preparation workflow from other real-time
workflows (for example, the real-time simulation workflow or the hardware-in-the-loop
simulation workflow).

Before performing this workflow, prepare your model for real-time simulation using the
“Real-Time Model Preparation Workflow” on page 7-5. The real-time model preparation

7-59
7 Real-Time Simulation

workflow shows you how to obtain reference results, determine the maximum step size,
and modify your model to simulate quickly and produce accurate results.

Use the real-time simulation workflow to increase the likelihood that your model is real-
time capable. Your model is real-time capable if it meets both of these criteria when you
simulate it on your real-time computer:

• The results match your expectations, based on empirical data or theoretical models.
• The model simulates without incurring an overrun.

The real-time simulation workflow uses bounded, that is fixed-step, fixed-cost,


simulation. Fixed-step, fixed-cost simulation sets an upper boundary on computational
cost by limiting both the step size and the number of iterations that the solver uses.

Make Your Model Real-Time Viable


Perform Fixed-Step, Fixed-Cost Simulation

Run your model on a desktop computer using fixed-step, fixed-cost configurations for
the global solver and local solvers. For more information on specifying fixed-step, fixed-
cost solver configurations for real-time simulation, see “Choose Step Size and Number of
Iterations” on page 7-79 and “Fixed-Cost Simulation for Real-Time Viability” on page
7-55.

Evaluate Model Accuracy

Compare the results from the simulation on the target computer to your reference
results. Are the reference and modified model results the same? If not, are they similar
enough that the empirical or theoretical data also supports the results from the
simulation of the modified model? Is the modified model representing the phenomena
that you want it to measure? Is it representing those phenomena correctly? If you plan on
using your model to test your controller design, is the model accurate enough to produce
results that you can rely on for system qualification? The answers to these questions help
you to decide if your real-time results are accurate enough.

Improve Accuracy by Adjusting Solver Settings

If your fixed-step, fixed-cost simulation results do not match your reference results, try to
improve accuracy by adjusting solver configurations. Increasing the number of iterations
or decreasing the step size can improve accuracy.

7-60
Real-Time Simulation Workflow

For an implicit global solver (ode14x), increase the number of Newton’s iterations. For
a Backward Euler or Trapezoidal Rule local solver, increase the number of nonlinear
iterations.

For the global solver, and for any local solvers, decrease the step size. Configure the step
size for each local solver as an integer multiple of the step size you specify for the global
solver.

Return to the Real-Time Model Preparation Workflow

If changing solver configurations does not improve or speed enough, try to make your
model real-time capable by returning to the real-time model preparation workflow.

Adjust the fidelity or scope of your model, and then step through the other processes and
decisions in the real-time model preparation workflow. Iterate on adjusting, simulating,
and analyzing your model until it is fast and accurate enough for you to attempt the real-
time simulation workflow again. For information, see “Real-Time Model Preparation
Workflow” on page 7-5.

Evaluate Overrun Risk

In terms of speed, the only method for definitively determining that your model is real-
time capable is to test for overruns during simulation on your target hardware. You
can, however, use fixed-step, fixed-cost simulation to estimate the likelihood that your
solver executes quickly enough for real-time simulation. For information on estimating
simulation time, see “Estimate Computation Costs” on page 7-76.

Improve Simulation Speed by Adjusting Solver Settings

If your computational cost estimate indicates that your model executes too slowly to
avoid an overrun on a real-time target, try to increase simulation speed by adjusting
solver configurations. Decreasing the number of iterations or increasing the step size can
improve accuracy.

For an implicit global solver (ode14x), decrease the number of Newton’s iterations.
For either a Backward Euler or Trapezoidal Rule local solver, decrease the number of
nonlinear iterations.

For the global solver, and for any local solvers, increase the step size. Configure the step
size for each local solver as an integer multiple of the step size you specify for the global
solver.

7-61
7 Real-Time Simulation

Model Is Real-Time Viable

When fixed-step, fixed-cost simulation results indicate that your model is likely real-time
capable, you can attempt real-time simulation on the target hardware. For information
on how you can use real-time simulation to test your controller hardware, see “What Is
Hardware-in-the-Loop Simulation?” on page 7-96.

Insufficient Computational Capability for Real-Time Viability


It is possible that your real-time target lacks the computational capability for running
your model in real time. If, after multiple iterations of the workflow, it appears that there
is no combination of model complexity and solver settings that can make your model real-
time viable, consider these options for increasing processing power:

• “Upgrading Target Hardware” on page 7-13


• “Simulating Parts of the System in Parallel” on page 7-13

Related Examples
• “Choose Step Size and Number of Iterations” on page 7-79
• “Determine System Stiffness” on page 7-68
• “Estimate Computation Costs” on page 7-76

More About
• “Fixed-Cost Simulation for Real-Time Viability” on page 7-55
• “Hardware-in-the-Loop Simulation Workflow” on page 7-100
• “Improving Speed and Accuracy” on page 7-10
• “Real-Time Model Preparation Workflow” on page 7-5
• “Solvers for Real-Time Simulation” on page 7-63
• “What Is Hardware-in-the-Loop Simulation?” on page 7-96

7-62
Solvers for Real-Time Simulation

Solvers for Real-Time Simulation

In this section...
“Choosing Between Discrete and Continuous Solvers” on page 7-64
“Computational Cost for Continuous Solvers” on page 7-64
“How Numerical Stiffness Affects Solver Choice” on page 7-65
“Using Simscape Local Fixed-Step Solvers” on page 7-66

To run your model on a real-time target, configure your model for fixed-step, fixed-cost
simulation. The type of fixed-step solver, step size, and number of iterations that you
specify affect the speed and accuracy of your real-time simulation.

Each distinct Simscape physical network in your model has its own Simscape Solver
Configuration block. You can set the solver choice differently for each physical network.
If you do not check the local solver option for a physical network, then that network will
use the Simulink global solver that you specify.

When choosing a fixed-step solver type, the main factors to consider for each network in
your model are:

• Whether the network is discrete or continuous


• The computational cost of the solver

• The numerical stiffness of the network

The following table summarizes the types of fixed-step solvers in the Simulink and
Simscape libraries.

Realm Type Numerical Method Solver


Simulink Continuous Explicit ode1 (Euler's method)
global solver ode2 (Huen’s method)
ode3 (Bogacki-Shampine)
ode4 (Fourth-Order Runge-Kutta, RK4)
ode5 (Dormand-Prince,RK5)
ode8 (Dormand-Prince, RK8)

7-63
7 Real-Time Simulation

Realm Type Numerical Method Solver


Implicit ode14x (extrapolation)
Discrete Not applicable Discrete (no continuous states)
Simscape local Continuous Implicit Backward Euler
network Trapezoidal Rule

Choosing Between Discrete and Continuous Solvers


To perform real-time simulation on a discrete model, for example, for the design of a
digital controller, specify the Simulink global discrete solver. If the network that contains
the controller has any continuous states, discretize the network. For an example that
shows how to discretize a controller, see Hydraulic Actuator Configured for HIL Testing.

Note: A physical network using a local solver appears to the global Simulink solver as if
it has discrete states.

If your controller model does contain continuous states, for example, if you are modeling
an analog controller, use a Simulink global continuous solver.

Computational Cost for Continuous Solvers


Computation cost is the number of calculations per time step that a processor performs.
Real-time readiness varies inversely with computation cost. The lower the computational
cost of a model is, the more likely it is that a real-time simulation of the model proceeds
without overruns and generates sufficiently accurate results.

The figure shows the normalized computational cost of all global and local continuous
fixed-step solvers. The data comes from a series of fixed-step, fixed-cost simulations using
the different solver types. The model is nonlinear and contains one physical network.
Although the solver type varies, the simulations use the same step size and a similar
setting for the total number of solver iterations. They do so because the step size and
number of iterations also affect the computational cost of a simulation.

7-64
Solvers for Real-Time Simulation

For a given accuracy, explicit global solvers generally have a lower computational cost
than implicit global solvers. Local (Simscape only) solvers are less costly than global
solvers.

How Numerical Stiffness Affects Solver Choice


To determine whether to use an explicit or implicit fixed-step solver for simulating your
model in real time, consider these two factors:

• The numerical stiffness of the system


• The computational cost of the solver

To determine if your system is stiff or nonstiff, simulate with different fixed-step solver
configurations and compare results from each to the reference results. If the step size is
too large, stiff systems can produce oscillations because they contain dynamics that vary
both quickly and slowly. For more information, see “Stiffness of System” and “Determine
System Stiffness” on page 7-68.

Explicit solvers are faster than implicit solvers, but they provide less accurate solutions
for numerically stiff systems because they tend to damp out oscillations. Implicit solvers

7-65
7 Real-Time Simulation

can better capture the oscillations that occur in stiff systems because they are more
robust than explicit solvers. However, implicit solvers deliver better accuracy at the
expense of speed.

If your controller model is continuous and numerically stiff, use the implicit solver
ode14x. If ode14x does not allow your model to simulate fast enough for real-time
simulation, at the expense of accuracy, you can:

• Improve simulation speed by increasing the step size or decreasing the number of
iterations.
• Reduce the stiffness of your model and specify an explicit solver instead of ode14x.

To determine the explicit solver that is the best choice for your less stiff or numerically
nonstiff, continuous controller model, perform bounded simulation using each of the
explicit continuous solvers. Configure each solver to use the same step size and a similar
number of solver iterations. Compare the simulation results and choose the solver that
provides the best combination of accuracy and speed.

To increase the accuracy of the results that your explicit solver provides, at the
expense of speed, decrease the step size or increase the number of iterations. For
more information on configuring your model for fixed-step, fixed-cost simulation, and
evaluating the results of bounded simulation, see “Choose Step Size and Number of
Iterations” on page 7-79.

Using Simscape Local Fixed-Step Solvers


You can usually further minimize computational cost by using a Simscape local solver for
each independent physical network in your model. For similar levels of accuracy, local
solvers have a lower computational cost than Simulink global solvers.

Simscape allows you to specify a different solver configuration for each independent
physical system (subsystem) in your model. You can use an implicit fixed-step solver on
the stiff local networks and an explicit fixed-step solver on the nonstiff local networks.
Optimizing solvers for each network minimizes the overall number of computations
done per time step and makes it more likely that the model can run in real time without
generating an overrun.

Choose between two Simscape fixed-step solvers for real-time simulation. Both are
implicit.

• Backward Euler

7-66
Solvers for Real-Time Simulation

• Trapezoidal Rule

The Backward Euler solver is more robust, and therefore more stable than the
Trapezoidal Rule solver. It tends to damp oscillations. The Trapezoidal Rule solver
is more accurate, but less stable than the Backward Euler solver. It tends to capture
oscillations, like those found in electrical systems with AC waveforms. Regardless of the
local solver you choose, the simulation uses the Backward Euler whenever numerical
stability is at risk:

• At the start of simulation.


• After an instantaneous change, when the corresponding block undergoes an internal
discrete change.

See Also
Solver Configuration

Related Examples
• “Determine System Stiffness” on page 7-68
• “Reduce Numerical Stiffness” on page 7-31
• “Choose Step Size and Number of Iterations” on page 7-79

More About
• “Choose a Fixed-Step Solver”
• “Fixed-Cost Simulation for Real-Time Viability” on page 7-55
• “Making Optimal Solver Choices for Physical Simulation” on page 4-21
• “Solver Classification Criteria”
• “Solvers”

7-67
7 Real-Time Simulation

Determine System Stiffness


In this section...
“Obtain Reference Results” on page 7-68
“Simulate with an Implicit Fixed-Step Solver” on page 7-69
“Simulate with an Explicit Fixed-Step Solver” on page 7-71
“Analyze the Results” on page 7-73

Determining the numerical stiffness of your model helps you to decide between using an
implicit or an explicit fixed-step solver for real-time simulation. To determine numerical
stiffness, first use the real-time model preparation workflow to optimize the speed and
accuracy of your model. Then, simulate your model using both explicit and implicit fixed-
step solvers. Compare the simulation results to see how the solvers behave. If your model
is numerically stiff, an explicit solver typically exhibits small oscillations around the
desired solution.

Implicit solvers are more robust than explicit solvers, however, explicit solvers are
faster. For robust results when performing real-time simulation with numerically stiff
model, use an implicit fixed-step solver. If your model is not stiff, use an explicit solver to
maximize simulation speed.

In this example, you obtain reference results by simulating a pneumatic model with a
variable-step solver. You also configure and simulate the model using an explicit and
then an explicit fixed-step global Simulink solver. Then you compare the results from all
three simulations to determine if the pneumatic model is numerically stiff.

Obtain Reference Results


1 To open the model, at the MATLAB command prompt, enter:

ssc_pneumatic_rts_reference
2 Save the model as stiffness_model to a writable folder on the MATLAB path.
3 Simulate the model.
4 Assign the simulation results to new variables.

yRef = yout;
tRef = tout;

7-68
Determine System Stiffness

5 Plot the results of the variable-step simulation.

h1 = figure;
plot(tRef,yRef);
h1Leg = legend({'Reference'});
title('Speed');
xlabel('Time (s)');
ylabel('Speed (rpm)');

Simulate with an Implicit Fixed-Step Solver


1 Configure the model for fixed-step simulation with implicit solver ode14x. In the
configuration parameters Solver pane, set:

7-69
7 Real-Time Simulation

• Type to Fixed-step
• Solver to ode14x (extrapolation)
• Under Additional options, Fixed-step size (fundamental sample time) to
1e-3
• Number of Newton's iterations to 1.

Click OK.
2 Simulate the model.
3 Assign the simulation results to new variables.

yOde14x = yout;
tOde14x = tout;
4 Use the stairs function to plot the results of the implicit fixed-step simulation so
you can see how the solver behaves when it executes each step in the simulation.

h1;
hold on;
stairs(tOde14x,yOde14x,'g--');
h1Leg = legend({'Reference','Impicit Solver'});

The results appear the same.

7-70
Determine System Stiffness

Simulate with an Explicit Fixed-Step Solver


1 Configure the model for fixed-step simulation with explicit fixed-step solver ode5. In
the configuration parameters Solver pane, set:

• Type to Fixed-step
• Solver to ode5 (Dormand-Prince)

Click OK.

7-71
7 Real-Time Simulation

2 Filter the input signal to provide the required input derivative for the explicit solver.
In the PS-S Simulink Converter block dialog box, on the Input Handling tab, set
Filtering and derivatives to Filter Input. Click OK.
3 Simulate the model.
4 Assign the simulation results to new variables.

yOde5 = yout;
tOde5 = tout;
5 Use the stairs function to plot the results of the explicit fixed-step simulation.

h1;
hold on;
stairs(tOde5,yOde5,'r-');
h1Leg = legend({'Reference','Impicit Solver','Expicit Solver'});

7-72
Determine System Stiffness

The results appear the same.

Analyze the Results


1 To see the results more closely, zoom to the inflection point at time t = ~ 1 second.

7-73
7 Real-Time Simulation

The implicit solver follows a path that is similar to the path that the variable-step
solver takes when generating the reference results. The oscillations that the explicit
solver exhibits indicate that the model is numerically stiff. The oscillations also
indicate that the explicit solver is more computationally costly than the implicit
solver for simulating the stiff model. Use a global or local implicit fixed-step
solver for real-time simulation with numerically stiff models to avoid unnecessary
computational cost.

See Also
stairs

7-74
Determine System Stiffness

Related Examples
• “Reduce Numerical Stiffness” on page 7-31
• “Determine Step Size” on page 7-15

More About
• “Filtering Input Signals and Providing Time Derivatives” on page 4-14
• “Real-Time Model Preparation Workflow” on page 7-5
• “Solvers for Real-Time Simulation” on page 7-63
• “Stiffness” on page 4-3

7-75
7 Real-Time Simulation

Estimate Computation Costs


Estimating computational cost helps you to determine if your model is likely to cause
an overrun when you simulate it on your real-time processor. Computational cost is the
execution time per time step during simulation. To estimate the time that it takes for
your model to execute on a real-time hardware target, estimate the simulation execution-
time budget for your real-time target.

To estimate the simulation execution-time, first, measure the execution time of desktop
simulation for a particular model. Then determine the average execution time per time
step on the real-time target for the same model. Knowing how these execution times
compare for one model means that you can estimate execution time on the real-time
target from desktop simulation execution time when you test other models. Having an
estimate for the execution-time budget helps you to choose a feasible combination of
solver settings for fixed-step, fixed-cost simulation.

During each time step, the real-time target must perform the procedures that the figure
shows.

The equation for determining the minimum step size to specify for the fixed-step solver to
avoid simulation overrun is

7-76
Estimate Computation Costs

Tsmin = TETmax + HLTmax ,

where

• TET is the task execution time. Task execution time involves calculating the
simulation results for the time step, processing inputs from and writing outputs to the
development computer, and performing general computing tasks such as buffering
data and accessing memory.
• THL is the hardware latency time. Hardware latency time includes scheduling,
interrupt and input/output (I/O) latency.
• Tsmin is the minimum step size.

If the time that it takes for the target to execute the simulation and handle latency
processes is less than the specified time step, the processor remains idle during the
remainder of the step. That is,

Ts = TETmax + HLTmax + IT ,

where

• Ts is the step size that you specify for the fixed-step solver.
• IT is the idle time.

This equation can be rearranged as:

TETmax = Ts - HLTmax - IT ,

The task execution, hardware latency and idle times vary, but you can implement a
safety margin by specifying the idle time in the budget calculation as a function of the
step size for the fixed-step solver. For example, if you specify a step size of 1e-5 for the
solver, and you want a 20% safety margin, then IT = (0.2)*(1e-5).

Therefore, the amount of time available for simulation execution can be calculated as
follows:

TETmax = Ts - HLTmax - ÈÎ( SMT ) * (Ts ) ˘˚ ,

where

7-77
7 Real-Time Simulation

• SMT is the desired safety margin, specified as a percent.

Related Examples
• “Reduce Computation Costs” on page 7-25

More About
• “Fixed-Cost Simulation for Real-Time Viability” on page 7-55
• “Simulation Phases in Dynamic Systems”

7-78
Choose Step Size and Number of Iterations

Choose Step Size and Number of Iterations

In this section...
“Obtain Reference Results” on page 7-80
“Determine Maximum Step Size for Accurate Results” on page 7-82
“Parameterize Global and Local Solver Settings” on page 7-84
“Perform Fixed-Step, Fixed-Cost Simulation” on page 7-85
“Adjust Solver Settings to Improve Accuracy” on page 7-89

The step size and number of iterations that you specify for solvers in your model affect
the speed and accuracy of your real-time simulation. If you decrease the step size or
increase the number of iterations, the results are more accurate, but the simulation runs
slower. If you increase the step size or decrease the number of iterations, the simulation
runs faster, but the results are less accurate.

To optimize your model for simulation on a real-time target, specify a combination of step
size (Ts) and number of iterations (N) that provides acceptable accuracy and the speed to
avoid an overrun. As with solver type, you can specify different combinations of Ts and N
values for the Simulink global solver and for each independent Simscape network in your
model.

This workflow helps you to select the step size and number of iterations for real-time
simulation:

• Obtain reference results by performing variable-step simulation on a model of a


hydraulic actuator.
• Use a modified version of the model to determine the maximum step size to use to
achieve accurate enough results from a fixed-step, fixed-cost simulation. Fixed-step,
fixed-cost simulation is required for real-time simulation.
• Specify global and local fixed-step, fixed-cost solver settings for the modified version of
the model.
• Perform a timed simulation with the modified model and evaluate the accuracy of the
results.
• Adjust the step size and number of iterations to find solver settings that provide the
required speed and accuracy for real-time simulation.

7-79
7 Real-Time Simulation

Obtain Reference Results


To obtain reference results, simulate the original version of the hydraulic actuator model.

1 To open the hydraulic actuator model, at the MATLAB command prompt, enter:

ssc_hydraulic_actuator_digital_control

2 Simulate the model.


3 Extract the data for pressure and simulation-step time from the logged Simscape
node.

simlogRef = simlog_ssc_hydraulic_actuator_digital_control;
pRefNode = simlogRef.Hydraulic_Actuator.Hydraulic_Cylinder.Chamber_A.A.p;
pRef = pRefNode.series.values ('Pa');
tRef = pRefNode.series.time;
4 Plot the step size.

h1 = figure;
semilogy(tRef(1:end-1),diff(tRef),'-x')
title('Solver Step Size');
xlabel('Time (s)');
ylabel('Step Size (s)');

7-80
Choose Step Size and Number of Iterations

The maximum step size (Tsmax) for obtaining accurate real-time results for the
original model is approximately 1e-2 seconds. For information on determining Tsmax,
see “Determine Step Size” on page 7-15.
5 Plot the simulation results.

h2 = figure;
plot(tRef,pRef, 'b-');
h2Legend1 = legend({'Reference'},'Location','southoutside');
title('Cylinder Pressure');
xlabel('Time (s)');
ylabel('Pressure (Pa)');

7-81
7 Real-Time Simulation

Determine Maximum Step Size for Accurate Results


In a modified version of the hydraulic actuator model, you can change the value of Tsmax,
the maximum step size for achieving accurate real-time simulation results.

1 Open the modified hydraulic actuator model.

ssc_hydraulic_actuator_HIL

7-82
Choose Step Size and Number of Iterations

This version of the hydraulic actuator contains a discretized, partitioned controller.


The local solver for the hydraulic actuator subsystem is enabled for fixed-step, fixed-
cost simulation. The step size is parameterized (ts) so that you can make solver
adjustments that decrease the likelihood of generating an overrun. For an example
that shows how to discretize the controller for the hydraulic actuator, see Hydraulic
Actuator Configured for HIL Testing.
2 To determine the maximum step size to use for achieving accurate real-time
simulation results, you simulate with a global, variable-step solver. To configure
the modified model for variable-step simulation using the global solver, disable
the local solver configuration. In the Hydraulic Actuator subsystem, in the Solver
Configuration block dialog box, clear the Use local solver check box.
3 Simulate the model.
4 Extract the data for pressure and time from the logged Simscape node.

simlog0 = simlog_ssc_hydraulic_actuator_HIL;
pNodeSim0 = simlog0.Hydraulic_Actuator.Hydraulic_Cylinder.Chamber_A.A.p;
pSim0 = pNodeSim0.series.values ('Pa');
tSim0 = pNodeSim0.series.time;
5 Plot the step size to the figure that contains the step-size data for the original model.

figure(h1)
hold on;
semilogy(tSim0(1:end-1),diff(tSim0),'--x', 'Color','r',...
'LineWidth',.1,'MarkerSize',5);
title('Solver Step Size');
xlabel('Time (s)');

7-83
7 Real-Time Simulation

ylabel('Step Size (s)');


h1Legend1 = legend({'Reference','Modified'},...
'Location','southoutside');

The discretized controller makes the modified model less stiff than the original model,
but it also reduces the maximum step size for obtaining accurate real-time results. For
the discretized model, Tsmax is between 1e-2 and 1e-3 seconds.

Parameterize Global and Local Solver Settings


To reduce the number of steps for finding the optimal real-time-simulation solver
settings, parameterize the solver configuration with workspace variables. In the
Hydraulic Actuator Discrete Model, the step size for the local solver configuration

7-84
Choose Step Size and Number of Iterations

is specified as the workspace variable ts. For this example, you also use workspace
variables to parameterize the global step size (tsG) and the local number of nonlinear
iterations (N).

1 For the modified model, in the model configuration parameters dialog box specify
these settings:

Pane Parameter Value Purpose


Solver Type Fixed-step Configure the global
solver of the modified
model for fixed-step
simulation.
Solver discrete (no Configure the global
continuous solver to match the
states) state of the controller.
Additional tsG Parameterize the
options > global step size.
Fixed-step size
(fundamental
sample time)
Simscape Limit data points Clear the check box. As you decrease the
solver step size, the
number of data points
that the simulation
generates increases.
Clear the option to
ensure that you collect
all the data that you
need for evaluating
simulation accuracy.
2 Configure the local solver for fixed-step simulation. In the Hydraulic Actuator
subsystem, in the Solver Configurationblock dialog box, select Use local solver.
3 To parameterize the cost of the simulation, set Nonlinear iterations to N.

Perform Fixed-Step, Fixed-Cost Simulation


You can determine if your solver settings are appropriate for real-time simulation by
simulating the model and then evaluating the accuracy of the results and the speed

7-85
7 Real-Time Simulation

of the simulation. To evaluate accuracy, compare the results to the reference results
and to the results of other fixed-step, fixed-cost simulations. To evaluate simulation
speed, compare the elapsed time to the specified simulation time and to the simulation
execution budget. If the speed or accuracy is not acceptable, adjust the step size and
number of iterations to make your model real-time capable.

The simulation execution-time budget for this example is four seconds. For information
on determining the execution-time budget for your model, see “Estimate Computation
Costs” on page 7-76.

1 For the first simulation, specify both the global and local step size as the largest
possible value of Tsmax from the step plot. Specify a relatively large value for the step
size for both solvers and three for the number of nonlinear iterations for the local
solver.

ts = 1e-2;
tsG = 1e-2;
N = 3;
2 Perform a timed fixed-step, fixed-cost simulation.

tic; sim('ssc_hydraulic_actuator_HIL'); tSim1 = toc;


time1 = max(tSim1);
3 Extract the data for pressure and simulation time from the logged Simscape node.

simlog1 = simlog_ssc_hydraulic_actuator_HIL;
pNodeSim1 = simlog1.Hydraulic_Actuator.Hydraulic_Cylinder.Chamber_A.A.p;
pSim1 = pNodeSim1.series.values ('Pa');
tSim1 = pNodeSim1.series.time;
4 Plot the simulation results to the figure that contains the reference results. Write
the elapsed time to the figure legend.

figure(h2)
hold on;
plot(tSim1, pSim1, 'g--');
delete(h2Legend1)
configSim1L = ['Local: Ts= ',num2str(ts),'s, N= ',num2str(N),'.'];
configSim1G = [' Global: Ts= ',num2str(tsG),'s.'];
timeSim1T = ['Time=',num2str(time1)];
cfgSim1 = [configSim1L,configSim1G,timeSim1T];
h2Legend2 = legend({'Reference',num2str(cfgSim1)},...
'Location','southoutside');

7-86
Choose Step Size and Number of Iterations

The elapsed time varies because it depends on the immediate computational capacity
of the computer that runs the simulation. The elapsed times in the legend are from
simulation on a 3.6 GHz Intel® CPU with a 16 GB memory. Your legend contains the
elapsed time for the simulation on your computer.

The simulation took less time to complete than the specified simulation time (10 s)
so it runs faster than real time on the development computer. The elapsed time is
also less than the simulation execution-time budget for this example (four seconds).
Therefore, the specified solver configuration provides an acceptable safety margin for
real-time simulation on the target that provided the budget data.
5 Zoom to an inflection point to evaluate the accuracy of the results.

7-87
7 Real-Time Simulation

figure(h2);
xStart = 0; xEnd = 10; yStart = 0; yEnd = 3.5e6;
xZoomStart = 0.3; xZoomEnd = 0.6;
yZoomStart = 2.6e6; yZoomEnd = 3.4e6;
axis([xZoomStart xZoomEnd yZoomStart yZoomEnd]);

Theoretical and empirical data support the reference results. The accuracy of the
simulation results is not acceptable because the solver oscillates before it converges
on the solution in the reference data.

7-88
Choose Step Size and Number of Iterations

If you can achieve acceptable result accuracy, but the simulation runs too slowly for a
given execution-time budget, increase speed by increasing the step size or decrease the
number of iterations.

When you find a combination of solver settings that provide accurate enough results
and a simulation speed that fits your execution-time budget, you can attempt to run
your model on a real-time target by performing the hardware-in-the-loop simulation
workflow. If you cannot find the right combination of solver settings, perform the real-
time model preparation workflow or increase your real-time computing capability to
improve simulation speed and accuracy. To increase your real-time computing capability,
upgrade your target hardware or partition your model for parallel processing.

Adjust Solver Settings to Improve Accuracy


You can generally improve accuracy by increasing the number of iterations or by
decreasing the step size.

1 Try to improve accuracy by increasing the number of iterations (N) to 10.

N = 10;
2 Run a timed simulation.

tic; sim('ssc_hydraulic_actuator_HIL'); tSim2 = toc;


time2 = max(tSim2);
3 Extract the pressure and simulation time data.

simlog2 = simlog_ssc_hydraulic_actuator_HIL;
pNodeSim2 = simlog2.Hydraulic_Actuator.Hydraulic_Cylinder.Chamber_A.A.p;
pSim2 = pNodeSim2.series.values ('Pa');
tSim2 = pNodeSim2.series.time;
4 Plot the results.

figure(h2)
hold on;
plot(tSim2, pSim2, 'r:');
delete(h2Legend2)
axis([xStart xEnd yStart yEnd]);
configSim2L = ['Local: Ts= ',num2str(ts),'s, N= ',num2str(N),'.'];
configSim2G = [' Global: Ts= ',num2str(tsG),'s.'];
timeSim2T = ['Time=',num2str(time2)];
cfgSim2 = [configSim2L,configSim2G,timeSim2T];

7-89
7 Real-Time Simulation

h2Legend3 = legend({'Reference',num2str(cfgSim1),num2str(cfgSim2)},...
'Location','southoutside');

The simulation is fast enough for real-time simulation because it took less time to
run than the four-second simulation execution budget.
5 Zoom to evaluate accuracy.

figure(h2);
axis([xZoomStart xZoomEnd yZoomStart yZoomEnd]);

7-90
Choose Step Size and Number of Iterations

Overall, the results are not much more accurate than the results from the simulation
with fewer iterations.
6 Try to improve accuracy by decreasing the step size to 1e-3 seconds for the local and
global solvers. Specify 3 for the number of iterations (N).

ts = 1e-3;
tsG = 1e-3;
N = 3;
7 Run a timed simulation.

tic; sim('ssc_hydraulic_actuator_HIL'); tSim3 = toc;


time3 = max(tSim3);

7-91
7 Real-Time Simulation

8 Extract the pressure and simulation time data.

simlog3 = simlog_ssc_hydraulic_actuator_HIL;
pNodeSim3 = simlog3.Hydraulic_Actuator.Hydraulic_Cylinder.Chamber_A.A.p;
pSim3 = pNodeSim3.series.values ('Pa');
tSim3 = pNodeSim3.series.time;
9 Plot the results.

figure(h2)
hold on;
plot(tSim3, pSim3, 'k--');
delete(h2Legend3)
axis([xStart xEnd yStart yEnd]);
configSim3L = ['Local: Ts= ',num2str(ts),'s, N= ',num2str(N),'.'];
configSim3G = [' Global: Ts= ',num2str(tsG),'s.'];
timeSim3T = ['Time=',num2str(time3)];
cfgSim3 = [configSim3L,configSim3G,timeSim3T];
h2Legend4 = legend...
({'Reference',num2str(cfgSim1),num2str(cfgSim2),num2str(cfgSim3)},...
'Location','southoutside');

7-92
Choose Step Size and Number of Iterations

The simulation takes longer (1.68 s) but is fast enough given the four-second
simulation execution-time budget.
10 Zoom to better evaluate accuracy.

figure(h2);
axis([xZoomStart xZoomEnd yZoomStart yZoomEnd]);

7-93
7 Real-Time Simulation

The accuracy of the results is acceptable. For real-time simulation with the modified
model, use the solver settings that provided acceptable speed and accuracy:

• Three nonlinear iterations


• Global and local step sizes of 1e-3 seconds

If you can achieve accurate enough results, but the simulation runs too slowly for your
execution-time budget, improve speed by increasing the step size or decreasing the
number of iterations.

When you find a combination of solver settings that provides accurate enough results and
a simulation speed that is less than your execution-time budget, you can run your model

7-94
Choose Step Size and Number of Iterations

on a real-time target. To run your model on a real-time target, perform the hardware-in-
the-loop simulation workflow.

If you cannot find the right combination of solver settings for real-time simulation,
improve simulation speed and accuracy by modifying the scope or fidelity of your model.
For more information, see “Real-Time Model Preparation Workflow” on page 7-5.

If you cannot make your model real-time capable by changing the scope or fidelity of
your model, increase your real-time computing capability. For more information, see
“Upgrading Target Hardware” on page 7-13 and “Simulating Parts of the System in
Parallel” on page 7-13.

Related Examples
• “Determine Step Size” on page 7-15
• “Determine System Stiffness” on page 7-68
• “Estimate Computation Costs” on page 7-76

More About
• “Filtering Input Signals and Providing Time Derivatives” on page 4-14
• “Fixed-Cost Simulation for Real-Time Viability” on page 7-55
• “Hardware-in-the-Loop Simulation Workflow” on page 7-100
• “Improving Speed and Accuracy” on page 7-10
• “Log and Plot Simulation Data” on page 9-8
• “Real-Time Model Preparation Workflow” on page 7-5
• “Solvers for Real-Time Simulation” on page 7-63
• “What Is Hardware-in-the-Loop Simulation?” on page 7-96

7-95
7 Real-Time Simulation

What Is Hardware-in-the-Loop Simulation?


Hardware-in-the-loop (HIL) simulation is a type of real-time simulation. You use HIL
simulation to test your controller design. HIL simulation shows how your controller
responds, in real time, to realistic virtual stimuli. You can also use HIL to determine if
your physical system (plant) model is valid.

In HIL simulation, you use a real-time computer as a virtual representation of your plant
model and a real version of your controller. The figure shows a typical HIL simulation
setup. The desktop computer (development hardware) contains the real-time capable
model of the controller and plant. The development hardware also contains an interface
with which to control the virtual input to the plant. The controller hardware contains the
controller software that is generated from the controller model. The real-time processor
(target hardware) contains code for the physical system that is generated from the plant
model.

7-96
What Is Hardware-in-the-Loop Simulation?

Why Perform Hardware-in-the-Loop Simulation?


Use HIL simulation to test the design of your controller when you are performing Model-
Based Design (MBD). The figure shows where HIL simulation fits into the MBD design-
to-realization workflow.

7-97
7 Real-Time Simulation

Validation involves using actual plant hardware to test your controller in real-life
situations or in environmental proxies (for example, a pressure chamber). In HIL
simulation, you do not have to use real hardware for your physical system (plant). You
also do not have to rely on a naturalistic or environmental test setup. By allowing you
to use your model to represent the plant, HIL simulation offers benefits in cost and
practicality.

There are several areas in which HIL simulation offers cost savings over validation
testing. HIL simulation tends to be less expensive when it comes to design changes. You
can perform HIL simulation earlier than validation in the MBD workflow so you can
identify and redesign for problems relatively early the project. Finding problems early
includes these benefits:

• Your team is more likely to approve changes.


• Design changes are less costly to implement.

7-98
What Is Hardware-in-the-Loop Simulation?

In terms of scheduling, HIL simulation is less expensive and more practical than
validation because you can set it up to run on its own.

HIL simulation is more practical than validation for testing your controller’s response
to unusual events. For example, you can model extreme weather conditions like
earthquakes or blizzards. You can also test how your controller responds to stimuli that
occur in inaccessible environments like deep sea or deep space.

Related Examples
• “Generate, Download, and Execute Code” on page 7-108

More About
• “Hardware-in-the-Loop Simulation Workflow” on page 7-100

7-99
7 Real-Time Simulation

Hardware-in-the-Loop Simulation Workflow

In this section...
“Perform Hardware-in-the-Loop Simulation” on page 7-104
“Insufficient Computational Capability for Hardware-in-the-Loop Simulation” on page
7-105

You must have a Simulink Real-Time license to perform this workflow.

This figure shows the hardware-in-the loop simulation workflow. The connectors are exit
points for returning to the real-time model preparation workflow.

7-100
Hardware-in-the-Loop Simulation Workflow

This figure shows the real-time model preparation workflow. The connector is an entry
point for returning to the real-time model preparation workflow from other real-time
workflows such as the hardware-in-the-loop simulation workflow.

7-101
7 Real-Time Simulation

This figure shows the real-time simulation workflow. The connectors are exit points for
returning to the real-time model preparation workflow.

7-102
Hardware-in-the-Loop Simulation Workflow

7-103
7 Real-Time Simulation

Before performing the hardware-in-the-loop (HIL) simulation workflow:

1 Prepare and configure your model for real-time simulation. For information, see
“Real-Time Model Preparation Workflow” on page 7-5 and “Real-Time Simulation
Workflow” on page 7-57.
2 Set up and configure the software, I/O interfaces, and connectivity for your
development computer, target computer, and I/O board. For information, see
Simulink Real-Time Setup and Configuration.
3 If you are performing HIL simulation to test your controller:

• Configure your controller.


• Connect your controller to the real-time computer.

Perform Hardware-in-the-Loop Simulation


Generate, Download, and Execute Code

Use Simulink Real-Time to:

• Generate and compile code on the development computer.


• Download the real-time application to the target computer.
• Execute the real-time application remotely from the development computer.

For information, see “Generate, Download, and Execute Code” on page 7-108.

Evaluate Accuracy

Compare the results from the simulation on the target computer to your reference
results. Are the reference and modified model results the same? If not, are they similar
enough that the empirical or theoretical data also supports the results from the
simulation of the modified model? Is the modified model representing the phenomena
that you want it to measure? Is it representing those phenomena correctly? If you plan on
using your model to test your controller design, is the model accurate enough to produce
results that you can rely on for system qualification? The answers to these questions help
you to decide if your real-time results are accurate enough.

Evaluate Speed

To find out if your simulation generates an overrun, examine the task execution time
(TET) report that Simulink Real-Time generates for the simulation.

7-104
Hardware-in-the-Loop Simulation Workflow

Return to the Real-Time Model Preparation Workflow

Your model is not real-time capable if simulation on your real-time target generates an
overrun or produces results that do not match your reference results closely enough. To
make your model real-time capable, return to the real-time model preparation workflow.

Adjust the fidelity or scope of your model, and then step through the other processes and
decisions in the real-time model preparation workflow. Iterate on adjusting, simulating,
and analyzing your model until it is fast and accurate enough for you to perform the real-
time simulation workflow. Perform the real-time simulation workflow, and then attempt
the hardware-in-the-loop simulation workflow again. For information, see “Real-Time
Model Preparation Workflow” on page 7-5 and “Real-Time Simulation Workflow” on page
7-57.

Insufficient Computational Capability for Hardware-in-the-Loop


Simulation
Your real-time target can lack the computational capability for running your model in
real time. If your model fails to run in real time or produces unreliable results on your
target after multiple iterations of the real-time workflows, consider these options for
increasing processing power:

• “Upgrading Target Hardware” on page 7-13


• “Simulating Parts of the System in Parallel” on page 7-13

Related Examples
• “Generate, Download, and Execute Code” on page 7-108

More About
• “Real-Time Model Preparation Workflow” on page 7-5
• “What Is Hardware-in-the-Loop Simulation?” on page 7-96
• “Real-Time Simulation Workflow” on page 7-57
• “Code Generation Requirements” on page 7-106

7-105
7 Real-Time Simulation

Code Generation Requirements

In this section...
“Hardware Requirements” on page 7-106
“Software Requirements” on page 7-107

Performing hardware-in-the-loop (HIL) simulation with Simulink Real-Time requires


specific hardware and software.

Hardware Requirements
The minimum hardware requirements for HIL simulation with Simulink Real-Time are:

• Development computer with a network or serial interface. For information on


development computer specifications, see Development Computer Requirements.
• Real-time target computer system, containing this hardware:

• CPU. For information on real-time target computer specifications, see “Target


Computer Requirements”
• I/O board. For information on supported I/O boards and for writing device drivers
for unsupported boards, see Supported Hardware: Hardware Drivers, “I/O
Boards”, and “I/O Driver Support”.
• Protocol interface
• Controller, preconfigured with code from your controller model
• Connection cable for linking the development computer to the real-time target. For
information, see “Links Between Development and Target Computers”.
• Peripherals that provide a way to:

• Boot the real-time target computer


• Transfer the Simulink Real-Time operating system and executable code to the
real-time target computer

For information, see “Peripherals”.


• Wiring harness to connect the real-time target computer to the controller.

7-106
Code Generation Requirements

Software Requirements
For information on the minimum software requirements for HIL simulation with
Simulink Real-Time, see Simulink Real-Time Software Requirements. The Simulink
Real-Time requirements include a C compiler. For information, see Simulink Real-Time
C Compiler Requirements and “Command-Line C Compiler Configuration”.

Note: If you want more configuration options for code optimization, use Embedded
Coder® to generate code for your real-time computer. For information, see “Embedded
Coder Product Description”.

Related Examples
• “Set Up and Configure Simulink Real-Time”
• “Create and Run a Real-Time Application”

More About
• “About Code Generation from Simscape Models” on page 8-2
• “How Simscape Code Generation Differs from Simulink” on page 8-5
• “Limitations” on page 9-3
• “Real-Time Test Environment”
• Simulink Real-Time Setup and Configuration
• “Simulink Real-Time Explorer”
• “What Is Hardware-in-the-Loop Simulation?” on page 7-96
• “Hardware-in-the-Loop Simulation Workflow” on page 7-100

7-107
7 Real-Time Simulation

Generate, Download, and Execute Code


In this section...
“Requirements for Building and Executing Simulink Real-Time Applications” on page
7-108
“Create, Build, and Download a Real-Time Application” on page 7-108
“Execute Real-Time Application” on page 7-109

You must have a Simulink Real-Time license to perform this workflow.

To perform hardware-in-the-loop simulation on target hardware, use Simulink Real-Time


to:

• Generate and compile code on the development computer.


• Download the real-time application to the target computer.
• Execute the real-time application remotely from the development computer.

Requirements for Building and Executing Simulink Real-Time Applications


Before building and executing your real-time application:

1 Prepare and configure your model for real-time simulation. For information, see
“Real-Time Model Preparation Workflow” on page 7-5 and “Real-Time Simulation
Workflow” on page 7-57.
2 Set up and configure the software, I/O interfaces, and connectivity for your
development computer, target computer, and I/O board. For information, see
Simulink Real-Time Setup and Configuration.

Create, Build, and Download a Real-Time Application


To generate code for the model on your development computer and transfer it to your
real-time computer:

1 Set the Simulink Real-Time code generation configuration parameters. For


information, see “Set Configuration Parameters”.
2 Start the target computer. For information, see “Start Target Computer”.

7-108
Generate, Download, and Execute Code

3 To compile your code, link your hardware, and download the real-time application to

your target in one step, in the Simulink editor, click the Build Model button .
For information, see “Build and Download Real-Time Application”.

Execute Real-Time Application


After you build and download a real-time application to the target computer, you can run
the real-time application.

1 In the Simulink window, on the toolbar, set the simulation mode to External.

Selecting external mode allows you to connect your development computer to your
real-time target.
2 To connect your development and target computers and to transfer your model

parameters to the target, click the Connect to Target button .


3 To execute your real-time application on the target computer, click the Run button

See Also
slrtexplr

Related Examples
• “Set Up and Configure Simulink Real-Time”
• “Create and Run a Real-Time Application”

More About
• “Hardware-in-the-Loop Simulation Workflow” on page 7-100
• “What Is Hardware-in-the-Loop Simulation?” on page 7-96
• “Hardware-in-the-Loop Simulation Process”

7-109
7 Real-Time Simulation

• “About Code Generation from Simscape Models” on page 8-2


• “How Simscape Code Generation Differs from Simulink” on page 8-5
• “Code Generation Requirements” on page 7-106
• “Configuration Parameters”
• “Real-Time Application Execution”
• “Simulink Real-Time Options Configuration Parameters”

7-110
Requirements for Using Alternative Platforms

Requirements for Using Alternative Platforms


In this section...
“Hardware Requirements” on page 7-111
“Software Requirements” on page 7-111

Performing hardware-in-the-loop (HIL) simulation with a custom standalone application


requires specific hardware and software.

Hardware Requirements
The minimum hardware requirements for HIL simulation with a custom application are:

• Development computer with a network, serial, or USB interface, as appropriate for


communicating with the real-time processor
• Real-time target, that is, a real-time capable CPU or computer
• I/O board that the real-time target supports
• Controller, preconfigured with code from your controller model
• Peripheral for transferring code to the real-time target
• Wiring harness to connect the real-time target to the controller

Note: You might also need a real-time operating system, depending on the requirements
of your real-time target.

Software Requirements
The minimum software requirements for HIL simulation with a custom application are:

• Embedded Coder and the Embedded Coder Software Requirements, including:

• Simulink Coder and the Simulink Coder Software Requirements.


• C compiler. For more about the Embedded Coder C compiler requirements, see
Embedded Coder C Compiler Requirements.
• Cross compiler.

7-111
7 Real-Time Simulation

• Template example main function that you can manually or automatically combine
with generated code
• I/O driver. Options are:

• C code I/O driver for the code generation build


• Precompiled static or dynamic library with the necessary documentation

More About
• “About Code Generation from Simscape Models” on page 8-2
• “How Simscape Code Generation Differs from Simulink” on page 8-5
• “Hardware-in-the-Loop Simulation Workflow” on page 7-100
• “Limitations” on page 9-3
• “What Is Hardware-in-the-Loop Simulation?” on page 7-96

7-112
8

Code Generation

• “About Code Generation from Simscape Models” on page 8-2


• “Reasons for Generating Code” on page 8-3
• “Using Code-Related Products and Features” on page 8-4
• “How Simscape Code Generation Differs from Simulink” on page 8-5
8 Code Generation

About Code Generation from Simscape Models


You can use Simulink Coder software to generate standalone C or C++ code from your
Physical Networks models and enhance simulation speed and portability. Certain
features of Simulink software also make use of generated or external code. This section
explains code-related tasks you can perform with your Simscape models.

Code versions of Simscape models typically require fixed-step Simulink solvers, which
are discussed in the Simulink documentation. Some features of Simscape software are
restricted when you translate a model into code. See “How Simscape Code Generation
Differs from Simulink” on page 8-5, as well as “Limitations” on page 4-32.

Note: Code generated from Simscape models is intended for rapid prototyping and
hardware-in-the-loop applications. It is not intended for use as production code in
embedded controller applications.

Add-on products based on the Simscape platform also support code generation, with some
variations and exceptions described in their respective documentation.

8-2
Reasons for Generating Code

Reasons for Generating Code


Code generation has many purposes and methods. There are two essential rationales:

• Compiled code versions of Simulink and Simscape models run faster than the original
block diagram models. The time savings can be dramatic.
• An equally important consideration for Simscape models is the standalone
implementation of generated and compiled code. Once you convert part or all of your
model to code, you can deploy the standalone executable program on virtually any
platform, independently of MATLAB.

Converting a model or subsystem to code also hides the original model or subsystem.

8-3
8 Code Generation

Using Code-Related Products and Features


With Simulink, Simulink Coder, and Simulink Real-Time software, using several
code-related technologies, you can link existing code to your models and generate code
versions of your models.

Code-Related Task Component or Feature


Link existing code written in C or Simulink S-functions to generate customized
other supported languages to Simulink blocks
models
Speed up Simulink simulations Accelerator mode
Rapid Accelerator mode
Generate standalone fixed-step code Simulink Coder software
from Simulink models
Generate variable-step code from Simulink Coder Rapid Simulation Target
Simulink models, well-suited for batch (RSim)
or Monte Carlo simulations
Convert Simulink model to code and Simulink Coder and Simulink Real-Time
compile and run it on a target PC software

8-4
How Simscape Code Generation Differs from Simulink

How Simscape Code Generation Differs from Simulink


In this section...
“Simscape and Simulink Code Generated Separately” on page 8-5
“Compiler and Processor Architecture Requirements” on page 8-5
“Precompiled Libraries Provided for Selected Compilers” on page 8-5
“Simscape Code Reuse Not Supported” on page 8-6
“Tunable Parameters Not Supported” on page 8-6
“Simscape Run-Time Parameter Inlining Override of Global Exceptions” on page
8-6

In general, using the code generated from Simscape models is similar to using code
generated from regular Simulink models. However, there are certain differences.

Simscape and Simulink Code Generated Separately


Simulink Coder software generates code from the Simscape blocks separately from the
Simulink blocks in your model. The generated Simscape code does not pass through
model.rtw or the Target Language Compiler. All the code generated from a single model
resides in the same directory, however.

Compiler and Processor Architecture Requirements


To generate and execute Simscape code, you must have a compiler and a processor that
support:

• 64-bit precision floating-point arithmetic


• 32-bit integer size

For details on supported compiler versions, see

http://www.mathworks.com/support/compilers/current_release

Precompiled Libraries Provided for Selected Compilers


Simscape software and its add-on products provide static runtime libraries precompiled
for compilers supported by Simulink Coder software. These are the standard UNIX

8-5
8 Code Generation

compilers for UNIX operating systems, lcc and Microsoft® Visual Studio® for 32-bit
Windows®, and Microsoft Visual Studio for 64-bit Windows.

For all other compilers, the static runtime libraries needed by code generated from
Simscape models are compiled once per model during the code generation build process.

Simscape Code Reuse Not Supported


Reusable subsystems in Simulink reuse code that is generated once from the subsystem.
You cannot generate reusable code from subsystems containing Simscape blocks.

Tunable Parameters Not Supported


A tunable parameter is a Simulink run-time parameter that you can change while the
simulation is running. Simscape blocks do not support tunable parameters in either
simulations or generated code.

Simscape Run-Time Parameter Inlining Override of Global Exceptions


If you choose to enable parameter inlining for code generated from a Simscape model,
the software inlines all its run-time parameters. If you choose to make some of the global
Simscape block parameters exceptions to inlining, the exceptions are ignored. You can
change global tunable parameters only by regenerating code from the model.

8-6
9

Data Logging

• “About Simulation Data Logging” on page 9-2


• “Enable Data Logging for the Whole Model” on page 9-4
• “Log Data for Selected Blocks Only” on page 9-5
• “Data Logging Options” on page 9-6
• “Log and Plot Simulation Data” on page 9-8
• “Log Simulation Statistics” on page 9-13
• “Log and View Simulation Data for Selected Blocks” on page 9-17
• “Log, Navigate, and Plot Simulation Data” on page 9-21
• “About the Simscape Results Explorer” on page 9-26
• “Use Custom Units to Plot Simulation Data” on page 9-27
• “View Sparkline Plots of Simulation Data” on page 9-31
9 Data Logging

About Simulation Data Logging


In this section...
“Suggested Workflows” on page 9-2
“Limitations” on page 9-3

Suggested Workflows
You can log simulation data to the workspace for debugging and verification. Data
logging lets you analyze how internal block variables change with time during
simulation. For example, you might want to see that the pressure in a hydraulic cylinder
is above some minimum value or compare it against the pump pressure. If you log
simulation data to the workspace, you can later query, plot, and analyze it without
rerunning the simulation.

Simulation data logging can also replace connecting sensors and scopes to track
simulation data. These blocks increase model complexity and slow down simulation. “Log
and Plot Simulation Data” on page 9-8 shows how you can log and plot simulation
data instead of adding sensors to your model. It also shows how you can print the
complete logging tree for a model and plot simulation results for a selected variable.

You can log data either for the whole model, or on a block-by-block basis. In the second
case, the workspace variable will contain simulation data for selected blocks only. To log
data for selected blocks only, you have to:

• Set the logging configuration parameter


• Select the blocks in your model

You can perform these two steps in any order. For more information, see “Log Data for
Selected Blocks Only” on page 9-5.

After running the simulation, you can use the Simscape Results Explorer tool to navigate
and plot the data logging results.

For additional information on how you can query, plot, and analyze data stored in the
simulation log variable, see the reference pages for the classes simscape.logging.Node,
simscape.logging.Series, and their associated methods.

You can also configure your model to automatically record Simscape logging data, along
with the rest of the simulation data obtained from a model run, using the Simulation

9-2
About Simulation Data Logging

Data Inspector. Set up your model to log simulation data, either for the whole model or
on a block-by-block basis, and enable data recording. Simulate the model, and then open
the Simulation Data Inspector and view the results. For detailed information on how to
enable data recording and how to configure and use the Simulation Data Inspector, see
“Inspect Signal Data with Simulation Data Inspector”.

To make your model simulation and data logging compatible with the parfor command,
select the Save simulation output as single object check box on the Data Import/
Export pane of the Configuration Parameters dialog box. In this case, Simscape log data
will be part of the single output object instead of being stored as a separate workspace
variable. For more information, see “Save simulation output as single object”.

Limitations
Simulation data logging is not supported for:

• Model reference
• Generated code
• Accelerator mode
• Rapid Accelerator mode

Related Examples
• “Log, Navigate, and Plot Simulation Data” on page 9-21
• “Log and View Simulation Data for Selected Blocks” on page 9-17
• “Log and Plot Simulation Data” on page 9-8
• “Log Simulation Statistics” on page 9-13

More About
• “Data Logging Options” on page 9-6

9-3
9 Data Logging

Enable Data Logging for the Whole Model


Using data logging is a best practice for Simscape models because it provides access to
important simulation and analysis tools. Therefore, when you create a model by using
the ssc_new function or any of the Simscape model templates, data logging for the whole
model is turned on automatically.

However, for models created using other methods, simulation data is not logged
by default. To turn on the data logging for a model, use the Log simulation data
configuration parameter.

1 In the model window, from the top menu bar, select Simulation > Model
Configuration Parameters. The Configuration Parameters dialog box opens.
2 In the Configuration Parameters dialog box, in the left pane, select Simscape.
The right pane displays the Log simulation data option, which is set to None, by
default.
3 From the drop-down list, select All, then click OK.
4 Simulate the model. This creates a workspace variable named simlog (as specified
by the Workspace variable name parameter), which contains the simulation data.

For information on how to access and use the data stored in this variable, see
the related examples listed below. For information on additional data logging
configuration options, see “Data Logging Options” on page 9-6.

Related Examples
• “Log, Navigate, and Plot Simulation Data” on page 9-21
• “Log and Plot Simulation Data” on page 9-8
• “Log Simulation Statistics” on page 9-13

More About
• “Data Logging Options” on page 9-6

9-4
Log Data for Selected Blocks Only

Log Data for Selected Blocks Only


Instead of logging the simulation data for the whole model, you can log data just for the
selected blocks.

1 Set the logging configuration parameter to enable simulation data logging on a


block-by-block basis.

In the model window, from the top menu bar, select Simulation > Model
Configuration Parameters. In the Configuration Parameters dialog box, in the
left pane, select Simscape, then set the Log simulation data parameter to Use
local settings. Click OK.
2 Select the blocks in your model. You can do this before or after setting the logging
configuration parameter.

For each block that you want to select for data logging, right-click on the block. From
the context menu, select Simscape > Log simulation data. A check mark appears
in front of the Log simulation data option.
3 Simulate the model. When the simulation is done, the simulation data log contains
only the data from the selected blocks.

To stop logging data for a previously selected block, right-click on it and select Simscape
> Log simulation data again to remove the check mark.

If you set the Log simulation data parameter to All, the simulation log will
contain data from the whole model, regardless of the block selections. Setting the Log
simulation data parameter to None disables data logging for the whole model.

Related Examples
• “Log and View Simulation Data for Selected Blocks” on page 9-17

More About
• “Data Logging Options” on page 9-6

9-5
9 Data Logging

Data Logging Options


When you set the Log simulation data configuration parameter to All or Use local
settings, other options in the Data Logging group box become available.

• Log simulation statistics — Select this check box if you want to access and analyze
information on zero crossings during simulation. By default, this check box is not
selected and the zero-crossing data is not logged. For more information on using this
check box, see “Log Simulation Statistics” on page 9-13.
• Open viewer after simulation — Select this check box if you want to open
Simscape Results Explorer, which is an interactive tool that lets you navigate and
plot the simulation data logging results. By default, this check box is not selected. For
more information, see “About the Simscape Results Explorer” on page 9-26.
• Workspace variable name — Specifies the name of the workspace variable
that stores the simulation data. Subsequent simulations overwrite the data in
the simulation log variable. If you want to compare data from two models or two
simulation runs, use different names for the respective log variables. The default
variable name is simlog.
• Decimation — Use this parameter to limit the number of data points saved, by
outputting data points for every nth time step, where n is the decimation factor.
The default is 1, which means that all points are logged. Specifying a different value
results in the first step, and every nth step thereafter, being logged. For example,
specifying 2 logs data points for every other time step, while specifying 10 logs data
points for just one in ten steps.
• Limit data points — Use this check box in conjunction with the Data history
(last N steps) parameter to limit the number of data points saved. The check box is
selected by default. If you clear it, the simulation log variable contains the data points
for the whole simulation, at the price of slower simulation speed and heavier memory
consumption.
• Data history (last N steps) — Specify the number of simulation steps to limit
the number of data points output to the workspace. The simulation log variable
contains the data points corresponding to the last N steps of the simulation, where
N is the value that you specify for the Data history (last N steps) parameter. You
have to select the Limit data points check box to make this parameter available.
The default value logs simulation data for the last 5000 steps. You can specify
any other positive integer number. If the simulation contains fewer steps than the
number specified, the simulation log variable contains the data points for the whole
simulation.

9-6
Data Logging Options

Saving data to the workspace can slow down the simulation and consume memory. To
avoid this, you can use either the Decimation parameter, or Limit data points in
conjunction with Data history (last N steps), or both methods, to limit the number
of data points saved. The two methods work independently from each other and can be
used separately or together. For example, if you specify a decimation factor of 2 and
keep the default value of 5000 for the Data history (last N steps) parameter, your
workspace variable will contain downsampled data from the last 10,000 time steps in the
simulation.

Note The Output options parameter, on the Data Import/Export pane of the
Configuration Parameters dialog box, also affects which data points are logged. For more
information, see “Data Import/Export Pane” in the Simulink documentation.

After changing your data logging preferences, rerun the simulation to generate a new
data log.

Related Examples
• “Enable Data Logging for the Whole Model” on page 9-4
• “Log Data for Selected Blocks Only” on page 9-5

More About
• “About Simulation Data Logging” on page 9-2

9-7
9 Data Logging

Log and Plot Simulation Data


This example shows how you can log and plot simulation data instead of adding sensors
to your model.

The model shown represents a permanent magnet DC motor.

This model is very similar to the Permanent Magnet DC Motor example, but, unlike the
example model, it does not include the Sensing unit w (Ideal Rotational Motion Sensor
and PS-Simulink Converter block) along with the Motor RPM scope. For a detailed
description of the Permanent Magnet DC Motor example, see “Evaluating Performance of
a DC Motor”.

1 Build the model, as shown in the preceding illustration.


2 To enable data logging, open the Configuration Parameters dialog box, in the left
pane, select Simscape, then set the Log simulation data parameter to All and
click OK.

9-8
Log and Plot Simulation Data

3 Simulate the model. This creates a workspace variable named simlog (as specified
by the Workspace variable name parameter), which contains the simulation data.
4 The simlog variable has the same hierarchy as the model. To see the whole variable
structure, at the command prompt, type:

simlog.print

This command prints the whole data tree.


mlog_ex_dcmotor1
+-Electrical_Reference2
| +-V
| | +-v
| +-i
+-Friction_Mr

9-9
9 Data Logging

| +-C
| | +-w
| +-R
| | +-w
| +-t
| +-w
+-L
| +-i
| +-i_L
| +-n
| | +-v
| +-p
| | +-v
| +-v
+-Load_Torque
| +-C
| | +-w
| +-R
| | +-w
| +-S
| +-t
| +-w
+-Mechanical_Rotational_Reference
| +-W
| | +-w
| +-t
+-Mechanical_Rotational_Reference1
| +-W
| | +-w
| +-t
+-Motor_Inertia_J
| +-I
| | +-w
| +-t
+-Rotational_Electromechanical_Converter
| +-C
| | +-w
| +-R
| | +-w
| +-i
| +-n
| | +-v
| +-p
| | +-v
| +-t
| +-v
| +-w
+-Rotor_Resistance_R
| +-i
| +-n
| | +-v
| +-p
| | +-v
| +-v
+-Simulink_PS_Converter

9-10
Log and Plot Simulation Data

+-x1_5V
+-i
+-n
| +-v
+-p
| +-v
+-v

5 Every node that represents an Across, Through, or internal block variable contains
series data. To get to the series, you have to specify the complete path to it through
the tree, starting with the top-level variable name. For example, to get a handle on
the series representing the angular velocity of the motor, type:
s1 = simlog.Rotational_Electromechanical_Converter.R.w.series;

From here, you can access the values and time vectors for the series and analyze
them.
6 You do not have to isolate series data to plot its values against time, or against
another series. For example, to see how the motor speed (in revolutions per minute)
changes with time, type:
plot(simlog.Rotational_Electromechanical_Converter.R.w,'units','rpm')

9-11
9 Data Logging

7 Compare this figure to the RPM scope display in the Permanent Magnet DC Motor
example. The results are exactly the same.
8 To plot the motor torque against its angular velocity, in rpm, and add descriptive
axis names, type:
plotxy(simlog.Rotational_Electromechanical_Converter.R.w,simlog.Motor_Inertia_J.t,...
'xunit','rpm','xname','Angular velocity','yname','Torque')

For more information on plotting logged simulation data, see the


simscape.logging.plot and simscape.logging.plotxy reference pages.

9-12
Log Simulation Statistics

Log Simulation Statistics


This example shows how you can access and analyze information on zero crossings
during simulation. By default, the zero-crossing data is not logged. If you select the Log
simulation statistics check box, the simulation log variable contains an additional
SimulationStatistics node for each block that can produce zero crossings, at the
price of slower simulation speed and heavier memory consumption.

The model shown represents a permanent magnet DC motor.

This model is the same as the one used in the “Log and Plot Simulation Data” on page
9-8 example.

1 Build the model, as shown in the preceding illustration.


2 To enable data logging, open the Configuration Parameters dialog box, in the left
pane, select Simscape, then set the Log simulation data parameter to All, select
the Log simulation statistics check box, and click OK.

9-13
9 Data Logging

3 Simulate the model. This creates a workspace variable named simlog (as specified
by the Workspace variable name parameter), which contains the simulation
data. Because you selected the Log simulation statistics checkbox, the workspace
variable contains additional nodes that represent zero-crossing data.
4 The simlog variable has the same hierarchy as the model. To see the whole variable
structure, at the command prompt, type:

simlog.print

This command prints the whole data tree.


mlog_ex_dcmotor1
+-Electrical_Reference2
| +-V

9-14
Log Simulation Statistics

| | +-v
| +-i
+-Friction_Mr
| +-C
| | +-w
| +-R
| | +-w
| +-SimulationStatistics
| | +-zc_0
| | | +-crossings
| | | +-values
| | +-zc_1
| | | +-crossings
| | | +-values
| | +-zc_2
| | +-crossings
| | +-values
| +-t
| +-w
+-L
| +-i
| +-i_L
| +-n
| | +-v
| +-p
| | +-v
| +-v
+-Load_Torque
| +-C
| | +-w
| +-R
| | +-w
| +-S
| +-t
| +-w
+-Mechanical_Rotational_Reference
| +-W
| | +-w
| +-t
+-Mechanical_Rotational_Reference1
| +-W
| | +-w
| +-t
+-Motor_Inertia_J
| +-I
| | +-w
| +-t
+-Rotational_Electromechanical_Converter
| +-C
| | +-w
| +-R
| | +-w
| +-i
| +-n
| | +-v

9-15
9 Data Logging

| +-p
| | +-v
| +-t
| +-v
| +-w
+-Rotor_ResistanceR
| +-i
| +-n
| | +-v
| +-p
| | +-v
| +-v
+-x1_5V
+-i
+-n
| +-v
+-p
| +-v
+-v

5 If you compare this tree to the one used in the “Log and Plot Simulation Data” on
page 9-8 example, you can see that under the Friction_Mr node there is now an
additional node called SimulationStatistics. The rest of the tree is unchanged.
This means that Friction Mr is the only block in the model that can generate zero-
crossings during simulation.
6 You can access and analyze this data similar to other data that is logged to
workspace during simulation. For more information, see simscape.logging.Node
class and simscape.logging.Series class reference pages.

9-16
Log and View Simulation Data for Selected Blocks

Log and View Simulation Data for Selected Blocks


This example shows how you can set your model to log simulation data for selected blocks
only and how to view simulation data using Simscape Results Explorer.

1 Open the Permanent Magnet DC Motor example model by typing ssc_dcmotor in


the MATLAB Command Window. Double-click the DC Motor subsystem to open it.

2 Open the Configuration Parameters dialog box and then, in the left pane, select
Simscape. This example model has data logging for the whole model enabled.
To enable data logging on a block-by-block basis, set the Log simulation data
parameter to Use local settings and click OK.

9-17
9 Data Logging

3 Select the blocks for data logging. Right-click the Rotational Electromechanical
Converter block. From the context menu, select Simscape > Log simulation data .

9-18
Log and View Simulation Data for Selected Blocks

After you select a block for data logging, a check mark appears in front of the Log
simulation data option in the context menu for that block.
4 Right-click the Motor Inertia block and select it for data logging, as described in the
previous step.
5 Simulate the model. This creates a workspace variable named
simlog_ssc_dcmotor (as specified by the Workspace variable name parameter),
which contains the simulation data for selected blocks only.
6 To open the Simscape Results Explorer, right-click one of the blocks previously
selected for data logging, for example, the Rotational Electromechanical Converter
block. From the context menu, select Simscape > View simulation data >
simlog_ssc_dcmotor.

Note: If you right-click a block that has not been selected for simulation data
logging, for example, the Load Torque block, the View simulation data option is
not available.

If you change the name of the log variable between simulation runs, the context
menu lists the names of all the log variables associated with the block. For example,
to compare data from two simulation runs, you can use different variable names
(such as simlog1 and simlog2). Open a Simscape Results Explorer window with
simlog1 results, then unlink it from the session and open another window with
simlog2 results. For more information, see “About the Simscape Results Explorer”
on page 9-26.

9-19
9 Data Logging

The Simscape Results Explorer window opens, with the


Rotational_Electromechanical_Converter node already selected in the left
pane, and all the node plots for this block displayed in the right pane. You can
see that it contains simulation data only for the two selected blocks, Rotational
Electromechanical Converter and Motor Inertia.

Related Examples
• “Log, Navigate, and Plot Simulation Data” on page 9-21

More About
• “About Simulation Data Logging” on page 9-2
• “About the Simscape Results Explorer” on page 9-26

9-20
Log, Navigate, and Plot Simulation Data

Log, Navigate, and Plot Simulation Data


This example shows the basic workflow for logging simulation data for the whole model
and then navigating and plotting the logged data using Simscape Results Explorer.

1 Open the Permanent Magnet DC Motor example model by typing ssc_dcmotor in


the MATLAB Command Window.

2 Open the Configuration Parameters dialog box and then, in the left pane, select
Simscape. You can see that this example model already has data logging for the
whole model enabled, as well as simulation statistics, and that the workspace
variable name is simlog_ssc_dcmotor. Select the Open viewer after simulation
check box and click OK.

9-21
9 Data Logging

3 Simulate the model. When the simulation is done, the Simscape Results Explorer
window opens. In the left pane, it contains the simulation log tree hierarchy, which
corresponds to the model hierarchy.

9-22
Log, Navigate, and Plot Simulation Data

4 When you click on a node in the left pane, the corresponding plots
appear in the right pane. Expand the DC_Motor node, and then click the
Rotational_Electromechanical_Converter node to see all the node plots for
this block.

9-23
9 Data Logging

5 To isolate the plot of the rotor angular velocity series against time, keep expanding
the nodes in the left pane until you get to the series data.

9-24
Log, Navigate, and Plot Simulation Data

Related Examples
• “Log and View Simulation Data for Selected Blocks” on page 9-17

More About
• “About Simulation Data Logging” on page 9-2
• “About the Simscape Results Explorer” on page 9-26

9-25
9 Data Logging

About the Simscape Results Explorer


Simscape Results Explorer is an interactive tool that lets you navigate and plot the
simulation data logging results.

When you configure the model to log simulation data (for the whole model or just
the selected blocks), you can make the Simscape Results Explorer window open
automatically upon completing a simulation run by selecting the Open viewer after
simulation check box in the Configuration Parameters dialog box. For more information
on this workflow, see “Log, Navigate, and Plot Simulation Data” on page 9-21.

Another way to open the Simscape Results Explorer window is to right-click on a block
and, from the context menu, select Simscape > View simulation data. For more
information, see “Log and View Simulation Data for Selected Blocks” on page 9-17.

You can control whether the Simscape Results Explorer window is reused when you
rerun the simulation, or a new window is opened after the next simulation run, by
linking and unlinking the window.

When you first open the Simscape Results Explorer window, it is linked to the current
MATLAB session. This means that when you run a new simulation, the results in the
window will be overwritten. To retain the current results and open a new window after

the next simulation, click the button located in the toolbar above the left pane. The

button appearance changes to and, when the new window opens after simulation,
that window will be linked to the session. Only one window can be linked to the session,

so if you have multiple windows open, linking one of them (by clicking on its button)
unlinks the previous one.

Related Examples
• “Log, Navigate, and Plot Simulation Data” on page 9-21
• “Log and View Simulation Data for Selected Blocks” on page 9-17
• “Use Custom Units to Plot Simulation Data” on page 9-27

9-26
Use Custom Units to Plot Simulation Data

Use Custom Units to Plot Simulation Data


Simscape Results Explorer has a set of default units for plotting the logged data. This
example shows how you can change to a custom unit; for example, to plot rotations in
degrees rather than radians.

1 Create a file named ssc_customlogunits.m and save it anywhere on the


MATLAB path. The file should contain a function called ssc_customlogunits,
which returns a cell array of the units to be used:

function customUnits = ssc_customlogunits()


customUnits = {'deg/s','deg'};
end

Include only the units you want to customize. For everything else, Simscape Results
Explorer will use the default units.
2 Open the Permanent Magnet DC Motor example model by typing ssc_dcmotor
in the MATLAB Command Window. This example model has data logging enabled
for the whole model, with the Workspace variable name parameter set to
simlog_ssc_dcmotor.

9-27
9 Data Logging

3 Simulate the model to log the simulation data.


4 Open the Simscape Results Explorer window and plot the rotational velocity of the
Inertia block:

sscexplore(simlog_ssc_dcmotor,'DC_Motor.Inertia.w')

By default, Simscape Results Explorer plots rotational velocity in rad/s.

9-28
Use Custom Units to Plot Simulation Data

5
To switch to custom units, click the Plot options icon and then, in the Options
dialog box, change Units from Default to Custom and click OK. The rotational
velocity plot is redrawn in deg/s.

Tip Use the function pm_getunits to get the full list of available units.

9-29
9 Data Logging

Related Examples
• “Log, Navigate, and Plot Simulation Data” on page 9-21
• “Log and View Simulation Data for Selected Blocks” on page 9-17

More About
• “About Simulation Data Logging” on page 9-2
• “About the Simscape Results Explorer” on page 9-26

9-30
View Sparkline Plots of Simulation Data

View Sparkline Plots of Simulation Data


This example shows the basic workflow for viewing sparkline plots of logged simulation
data for selected blocks and variables directly on the model canvas. Before viewing
sparkline plots, you must enable data logging for the whole model, or at least for those
blocks where you want to display the data, and run the simulation.

1 Open the Permanent Magnet DC Motor example model by typing ssc_dcmotor in


the MATLAB Command Window. This example model has data logging for the whole
model enabled.

2 Double-click the DC Motor subsystem to open it.


3 Simulate the model.
4 To enable display of the sparkline plots on the model canvas, in the model window,
from the top menu bar, select Display > Simscape > Toggle Sparklines When
Clicked. This action adds the check mark next to the Toggle Sparklines When
Clicked menu option, and you can start selecting blocks to display sparkline plots of
logged data for their variables. Repeatedly selecting a block toggles the display of its
sparkline plots on and off.

9-31
9 Data Logging

5 Select the Rotational Electromechanical Converter block. Sparkline plots of the first
three variables available for this block are displayed on the canvas, and the field
below the plots shows that 5 more variables are available.

6 To customize which plots are shown on the canvas, click the little wrench symbol in
the field below the plots.

9-32
View Sparkline Plots of Simulation Data

This action displays a list of all the block variables available, with check marks next
to the one currently plotted.

9-33
9 Data Logging

7 Clear all the check marks and select the last variable w instead. Then click anywhere
on the model canvas to close the variable selection box.

As you hover over the field with the variable name on the canvas, it expands into a
sparkline plot of logged simulation data for that variable.

9-34
View Sparkline Plots of Simulation Data

The plot display includes the minimum and maximum values, as well as time and
value for the current cursor position.
8 As you move your cursor past the right edge of the plot, the current value is replaced
with the last value of the variable. Clicking or hovering over the arrow to the right
of the sparkline plot opens an additional field underneath, which contains a link
to the Simscape Results Explorer. When you click the icon, the Simscape Results
Explorer window opens, displaying the corresponding plot in the right pane, with the
appropriate node selected in the left pane.

9-35
9 Data Logging

Tips

9-36
View Sparkline Plots of Simulation Data

• If you select a block for which simulation data is not being logged, it displays No
variables instead of the sparkline plots. Right-click the block, select Simscape >
Log simulation data, and rerun the simulation.

• To clear all plots and start again with a clean canvas, select Display > Simscape >
Remove All Sparklines. Then you can select more blocks and variables to display
their sparkline plots.
• Repeatedly selecting the Toggle Sparklines When Clicked menu option toggles the
ability to view the sparkline plots for the model on or off, as indicated by the check
mark. When the check mark is on, repeatedly selecting a block toggles the display of
its sparkline plots on and off.

Related Examples
• “Log, Navigate, and Plot Simulation Data” on page 9-21
• “Log and View Simulation Data for Selected Blocks” on page 9-17

More About
• “About Simulation Data Logging” on page 9-2
• “About the Simscape Results Explorer” on page 9-26

9-37
10

Model Statistics

• “Simscape Model Statistics” on page 10-2


• “1-D Physical System Statistics” on page 10-4
• “3-D Multibody System Statistics” on page 10-7
• “1-D/3-D Interface Statistics” on page 10-10
• “View Model Statistics” on page 10-11
• “Access Block Variables Using Statistics Viewer” on page 10-16
10 Model Statistics

Simscape Model Statistics


Viewing Simscape model statistics is a good way to evaluate the model prior to
simulation. Model statistics provide feedback on the model complexity, so that you can
make informed choices about whether you want to simulate the model in its current
configuration or make changes to it. This approach helps you achieve the desired
simulation performance and goals.

Unlike other derived data (such as data logging or simulation statistics), which is
generated during simulation, model statistics is compile-time data that is generated
before the model is simulated. When you generate model statistics, the model must
be in a compilable state, that is, it must satisfy the requirements described in “Model
Validation” on page 4-7.

Use model statistics as part of the iterative model building process. For example, after
you make a change to the model, you can view model statistics to answer the following
questions:

• Did the change increase the number of variables?


• Does the model have redundant constraints or have I resolved them?
• How many potential zero-crossing signals does the model have?
• Is the circuit high-index, and therefore hard to solve? Did my change have any effect
on the index?

The Statistics Viewer analysis tool is available for models containing Simscape blocks
and blocks from add-on products. Depending on the types of blocks in the model, the
analysis can produce any or all of the following statistics categories:

• 1-D Physical System — This node represents aggregate statistics generated from
all physical networks that are associated with blocks from Simscape, SimDriveline™,
SimHydraulics, SimElectronics®, and SimPowerSystems™ Simscape Components
libraries.
• 3-D Multibody System — This node represents aggregate statistics generated from
all physical networks that are associated with blocks from SimMechanics™ Second
Generation library.
• 1-D/3-D Interface — This node lists the connections between the two types of
physical networks. It appears only for models that connect blocks from SimMechanics
Second Generation library to Simscape blocks, or blocks from other add-on products.

10-2
Simscape Model Statistics

Each statistic is generated separately from each topologically distinct physical network of
these blocks and then aggregated to appear as a single statistic in the Statistics Viewer.

The Sources section of the Statistics Viewer window lists variable sources for the
selected statistic:

• If you select a connection under the 1-D/3-D Interface statistic category, the
Sources section lists the source and destination for this connection, with links to
relevant blocks.
• If you select a statistic with a nonzero value under the 1-D Physical System
category, the Sources section lists all the variables that fall under this statistic.

For each variable, the Source column contains the full path to the variable, starting
from the top-level model, with a link to the relevant block. If you click the link in the
Source column, the corresponding block is highlighted in the block diagram. The
Value column contains the name of the variable, as it would appear in the Variables
tab of the block dialog box.

Related Examples
• “View Model Statistics” on page 10-11
• “Access Block Variables Using Statistics Viewer” on page 10-16

More About
• “1-D Physical System Statistics” on page 10-4
• “3-D Multibody System Statistics” on page 10-7
• “1-D/3-D Interface Statistics” on page 10-10

10-3
10 Model Statistics

1-D Physical System Statistics


This node represents aggregate statistics generated from all physical networks that are
associated with blocks from Simscape, SimDriveline, SimHydraulics, SimElectronics, and
SimPowerSystems Simscape Components libraries.

Each statistic is generated separately from each topologically distinct physical network of
these blocks and then aggregated to appear as a single statistic.

The individual statistics are:

• Number of variables — This statistic represents the number of variables associated


with all 1-D physical systems in the model. Variables are categorized further as
continuous, eliminated, and discrete variables.
• Number of continuous variables (retained) — This statistic represents the
number of continuous variables associated with all 1-D physical systems in the model.
Continuous variables are those variables whose values vary continuously with time,
although some continuous variables can change values discontinuously after events.
Continuous variables are categorized further as algebraic and differential variables.

This statistic represents the number of continuous variables in the system after
variable elimination. If a system is truly input-output with no dynamics, it is possible
to completely eliminate all variables and, in that case, the number of variables is zero.

• Number of differential variables — This statistic represents the number


of differential variables associated with all 1-D physical systems in the model.
Differential variables are continuous variables whose time derivative appears in
one or more system equations. These variables add dynamics to the system and
require the solver to use numerical integration to compute their values.

This statistic represents the number of differential variables in the model after
variable elimination.
• Number of algebraic variables — This statistic represents the number
of algebraic variables associated with all 1-D physical systems in the model.
Algebraic variables are continuous system variables whose time derivative
does not appear in any system equations. These variables appear in algebraic
equations but add no dynamics, and this typically occurs in physical systems due
to conservation laws, such as conservation of mass and energy.

This statistic represents the number of algebraic variables in the model after
variable elimination.

10-4
1-D Physical System Statistics

• Number of continuous variables (eliminated) — This statistic represents the


number of eliminated variables associated with all 1-D physical systems in the model.
Eliminated variables are continuous variables that are eliminated by the software
and are not used in solving the system. Eliminated variables are categorized further
as algebraic and differential variables.

• Number of differential variables — This statistic represents the number of


eliminated differential variables associated with all 1-D physical systems in the
model. Differential variables are continuous variables whose time derivative
appears in one or more system equations. These variables add dynamics to the
system and require the solver to use numerical integration to compute their
values.

This statistic represents the number of differential variables in the model that
have been eliminated.
• Number of algebraic variables — This statistic represents the number of
eliminated algebraic variables associated with all 1-D physical systems in the
model. Algebraic variables are continuous system variables whose time derivative
does not appear in any system equations. These variables appear in algebraic
equations but add no dynamics, and this typically occurs in physical systems due
to conservation laws, such as conservation of mass and energy.

This statistic represents the number of algebraic variables in the model that have
been eliminated.
• Number of discrete variables — This statistic represents the number of discrete,
or event, variables associated with all 1-D physical systems in the model. Discrete
variables are those variables whose values can change only at specific events. Discrete
variables are categorized further as integer-valued and real-valued discrete variables.

• Number of integer-valued variables — This statistic represents the number of


integer-valued discrete variables associated with all 1-D physical systems in the
model. Integer-valued discrete variables are system variables that take on integer
values only and can change their values only at specific events, such as sample
time hits. These variables are typically generated from blocks that are sampled
and run at specified sample times.
• Number of real-valued variables — This statistic represents the number of
real-valued discrete variables associated with all 1-D physical systems in the
model. Real-valued discrete variables are system variables that take on real values
and can change their values only at specific events.

10-5
10 Model Statistics

If you select a local solver in the Solver Configuration block, then all continuous
variables associated with that system are discretized and represented as real-
valued discrete variables.
• Number of zero-crossing signals — This statistic represents the number of scalar
signals that are monitored by the Simulink zero-crossing detection algorithm. Zero-
crossing signals are scalar functions of states, inputs, and time whose crossing zero
indicates discontinuity in the system. These signals are typically generated from
operators and functions that contain discontinuities, such as comparison operators,
abs, sqrt functions, and so on. Times when these signals cross zero are reported
as zero-crossing events. During simulation it is possible for none of these signals to
produce a zero-crossing event or for one or more of these signals to have multiple zero-
crossing events.
• Number of dynamic variable constraints — This statistic represents the number
of constraints involving only dynamic variables and inputs. Such constraints result in
high-index differential algebraic equations (DAEs) and therefore can cause numerical
difficulties or slow down your simulation.

If you select a statistic with a nonzero value, the Sources section lists all the variables
that fall under this statistic. For each variable:

• The Source column contains the full path to the variable, starting from the top-level
model, with a link to the relevant block. If you click the link in the Source column,
the corresponding block is highlighted in the block diagram.
• The Value column contains the name of the variable, as it would appear in the
Variables tab of the block dialog box.

Related Examples
• “View Model Statistics” on page 10-11
• “Access Block Variables Using Statistics Viewer” on page 10-16

10-6
3-D Multibody System Statistics

3-D Multibody System Statistics


This node represents aggregate statistics generated from all physical networks that are
associated with blocks from SimMechanics Second Generation library.

Each statistic is generated separately from each topologically distinct physical network of
these blocks and then aggregated to appear as a single statistic.

The individual statistics are:

• Number of rigidly connected components (excluding ground) — This statistic


provides the number of rigid components present in a mechanical system. Rigid
components are subsets of rigidly connected blocks that represent rigid bodies or rigid
frame networks in a model. These subsets generally include blocks from the Body
Elements library as well as Rigid Transform blocks.

Rigid connections within a rigid component can include Rigid Transform blocks but
not Weld Joint blocks. Rigid Transform blocks provide rigid connections between
blocks in the same rigid component. Weld Joint blocks, like all joint blocks, provide
connections between blocks in different rigid components.

This statistic excludes from the count any rigid component that rigidly connects to the
World Frame block.
• Number of joints (total) — This statistic provides the total number of joints
present in a mechanical system. This number equals the sum of three types of joints:
explicit tree, cut, and implicit 6-DOF joints. For more information, see the statistic
descriptions for these joints.

The kinematic graph provides a practical means to understand the topology of


a model. This graph is a connected, undirected diagram in which each vertex
corresponds to a rigid component and each edge corresponds to a joint. The total
number of joints equals the total number of edges present in this graph.

The kinematic tree is a spanning tree of the kinematic graph in which each closed
loop is opened by cutting one of its edges. If the kinematic graph contains no closed
loops, it is identical to the kinematic tree.
• Number of explicit tree joints — This statistic provides the number of joints in the
kinematic tree of a mechanical system that correspond to explicit joint blocks. Each
tree joint corresponds to an edge in the kinematic tree. The number of explicit tree
joints excludes joints cut from the kinematic graph to generate the kinematic tree.

10-7
10 Model Statistics

For more information about kinematic graphs and trees, see the statistic description
for Number of joints (total).
• Number of implicit 6-DOF tree joints — This statistic provides the number of 6-
DOF joints in the kinematic tree of a mechanical system that do not correspond to
explicit joint blocks. SimMechanics adds implicit 6-DOF joints when the kinematic
graph of a model is not fully connected. These implicit joints connect previously
disconnected portions of the graph to the ground body, adding the edges required to
fully connect the graph. Implicit joints are always tree joints and do not create loops.

For more information about kinematic graphs and trees, see the statistic description
for Number of joints (total).
• Number of cut joints — This statistic provides the number of joints that are
cut from the kinematic graph of a mechanical system to generate the associated
kinematic tree. The number of cut joints equals the number of closed loops present in
the kinematic graph.

For more information about kinematic graphs and trees, see the statistic description
for Number of joints (total).
• Number of constraints — This statistic provides the total number of constraint
blocks in a mechanical system.
• Number of tree degrees of freedom — This statistic provides the total number of
degrees of freedom in the kinematic tree of a mechanical system. This number equals
the sum of all degrees of freedom that the tree joints provide. It excludes degrees of
freedom associated with cut joints.

For more information about kinematic graphs and trees, see the statistic description
for Number of joints (total).
• Number of position constraint equations (total) — This statistic provides the
number of scalar equations that impose position constraints on a mechanical system.
Constraint equations arise from two types of blocks: Constraints and Joints. Joint
blocks contribute constraint equations only if the joints are cut in the kinematic tree.
The number of position constraint equations that a cut joint contributes equals six
minus the number of degrees of freedom that joint provides.

For more information about kinematic graphs and trees, see the statistic description
for Number of joints (total).
• Number of position constraint equations (non-redundant) — This statistic
provides the number of unique position constraint equations associated with a model.

10-8
3-D Multibody System Statistics

This number is smaller than or equal to the total number of position constraint
equations. The difference between the two is the number of redundant position
constraint equations, which are satisfied whenever the unique position constraint
equations are satisfied. SimMechanics attempts to remove redundant equations to
improve simulation performance.
• Number of mechanism degrees of freedom (minimum) — This statistic provides
a lower bound on the number of degrees of freedom in a mechanical system. It equals
the difference between the number of tree degrees of freedom and the number of non-
redundant position constraint equations. The actual number of degrees of freedom can
exceed this lower bound if SimMechanics fails to detect a position constraint equation.

Some position constraint equations become redundant only in certain configurations.


If an equation becomes redundant during simulation, the actual number of degrees of
freedom in a model can change. However, that number must still equal or exceed the
lower bound that this statistic provides.
• State vector size — This statistic provides the number of scalar values in the state
vector of a mechanical system.
• Average kinematic loop length — This statistic provides the average number
of edges—or, equivalently, vertices—in the closed loops of a kinematic graph. The
average number is taken over all loops in the graph. If the graph has no kinematic
loops, this number equals zero.

For more information about kinematic graphs and trees, see the statistic description
for Number of joints (total).

10-9
10 Model Statistics

1-D/3-D Interface Statistics


This node lists statistics related to the interface between all 1-D physical and 3-D
multibody systems present in the model. It appears only for models that connect blocks
from SimMechanics Second Generation library to blocks from Simscape, SimDriveline,
SimHydraulics, SimElectronics, and SimPowerSystems Simscape Components libraries.

All connections are listed individually as Connection 1, Connection 2, and so on. If


you select an individual connection, the Sources section lists the source and destination
ports for this connection:

• The Source column contains the full path to the interface port, starting from the
top-level model, with a link to the relevant block. If you click the link in the Source
column, the corresponding block is highlighted in the block diagram.
• The Value column specifies whether the port is the source or destination.

If you expand a connection node, the Statistics Viewer provides the filtering information:
whether a filter is used, and, if yes, the filter order and time constant.

10-10
View Model Statistics

View Model Statistics


This example shows how you can use model statistics to determine the effect of a change
on model complexity.

1 Open the Simple Mechanical System example model.

2 To view model statistics, in the top menu bar of the model window, select Analysis >
Simscape > Statistics Viewer.

The Simscape Statistics window opens, displaying the name of the model and an
overview of the models statistics in a collapsed state.
3 Click to expand all nodes.

10-11
10 Model Statistics

You can see that, after variable elimination, the model contains five continuous
differential variables, no algebraic variables, no discrete variables, and no zero-
crossing signals.
4 Replace the Translational Damper block in the model diagram with a Translational
Friction block, as shown in the following figure.

10-12
View Model Statistics

5 Select Analysis > Simscape > Statistics Viewer to refresh the model statistics.

10-13
10 Model Statistics

The revised model contains five differential variables, six algebraic variables,
and two zero-crossing signals. This happened because you replaced a linear block
(Translational Damper) with a nonlinear one (Translational Friction). Therefore
the linear optimization that the solver initially performed on the model no longer
applies.

10-14
View Model Statistics

Related Examples
• “Access Block Variables Using Statistics Viewer” on page 10-16

More About
• “1-D Physical System Statistics” on page 10-4

10-15
10 Model Statistics

Access Block Variables Using Statistics Viewer


This example shows how you can use the Sources section of the Statistics Viewer to
access a block variable of interest, to verify (or change) its initialization priority and
target value.

1 Open the Permanent Magnet DC Motor example model.

2 To view model statistics, in the top menu bar of the model window, select Analysis >
Simscape > Statistics Viewer.

The Simscape Statistics window opens, displaying the name of the model and an
overview of the models statistics in a collapsed state.
3 Expand the Number of variables node, then Number of continuous variables
(retained), and then click Number of differential variables.

10-16
Access Block Variables Using Statistics Viewer

You can see that, after variable elimination, the model contains three continuous
differential variables, and the Sources section of the Statistics Viewer lists these
three variables. For each variable:

• The Source column contains the full path to the variable, starting from the top-
level model, with a link to the relevant block.
• The Value column contains the name of the variable, as it would appear in the
Variables tab of the block dialog box.
4 Click the first link in the Source column. The full path indicates that the source
variable w belongs to the Inertia block in the DC Motor subsystem of the top-level
example model, therefore the DC Motor subsystem opens and the corresponding
block is highlighted in the block diagram, as shown in the following figure.

10-17
10 Model Statistics

5 Double-click the highlighted block.


6 In the block dialog box, click the Variables tab.

10-18
Access Block Variables Using Statistics Viewer

According to the Value column in the Statistics Viewer, the name of the variable in
the block dialog box is Rotational velocity. The dialog box shows that this variable
has high initialization priority and a target value of 0 rad/s. You can modify the
priority and value, if needed, and then open the Variable Viewer to see the model
initialization results.

Related Examples
• “Set Priority and Initial Target for Block Variables” on page 5-5

More About
• “1-D Physical System Statistics” on page 10-4
• “About Variable Initialization” on page 5-2
• “Variable Viewer” on page 5-23

10-19
11

Physical Units

• “How to Work with Physical Units” on page 11-2


• “Unit Definitions” on page 11-4
• “How to Specify Units in Block Dialogs” on page 11-9
• “Thermal Unit Conversions” on page 11-11
• “Angular Units” on page 11-15
• “Units for Angular Velocity and Frequency” on page 11-16
11 Physical Units

How to Work with Physical Units


Unlike Simulink signals, which are essentially unitless, physical signals can have units
associated with them. You specify the units along with the parameter values in the block
dialogs, and Simscape unit manager performs the necessary unit conversion operations
when solving a physical network. Simscape blocks support standard measurement
systems. The default block units are meter-kilogram-second or MKS (SI).

Simscape software comes with a library of standard units, and you can define additional
units as needed (see “Unit Definitions” on page 11-4). You can use these units in
your block diagrams:

• To specify the units of an input physical signal, type a unit name, or a mathematical
expression with unit names, in the Input signal unit field of the Simulink-PS
Converter block dialog. You can also select a unit from a drop-down list, which
is prepopulated with some common input units. Signal units that you specify in a
Simulink-PS Converter block must match the input type expected by the Simscape
block connected to it. For example, when you provide the input signal for an Ideal
Angular Velocity Source block, specify angular velocity units, such as rad/s or
rpm, in the Simulink-PS Converter block, or leave it unitless. If you leave the block
unitless, with the Input signal unit parameter set to 1, then the physical signal
units are inferred from the destination block.
• Simscape block dialogs have drop-down combo boxes of units next to a parameter
value, letting you either select a unit from the drop-down list, or type a unit name
(or a mathematical expression with unit names) directly into the box. These drop-
down lists are automatically populated by those units that are commensurate with
the unit of the parameter, based on the current list of unit definitions. For example,
if a parameter is specified, by default, with the units of meters per second, m/s, the
drop-down list of units contains commensurate units, such as mm/s, in/s, fps (feet
per second), fpm (feet per minute), and so on, including any other linear velocity units
currently defined in your unit registry.
• To specify the units of an output physical signal, type a unit name, or a mathematical
expression with unit names, in the Output signal unit field of the PS-Simulink
Converter block dialog. You can also select a unit from a drop-down list, which is
prepopulated with some common output units. The system compares the units you
specified with the actual units of the input physical signal coming into the converter
block and applies a gain equal to the conversion factor before outputting the Simulink
signal. The default value is 1, which means that the unit is not specified. If you do not

11-2
How to Work with Physical Units

specify a unit, or if the unit matches the actual units of the input physical signal, no
gain is applied.

For more information, see “How to Specify Units in Block Dialogs” on page 11-9.

Note Currently, the blocks in the Physical Signals library (such as PS Add, PS Gain, and
so on) ignore the physical unit of the input signal and just perform calculations on the
value. The output signals of the Physical Signals library blocks are unitless.

11-3
11 Physical Units

Unit Definitions
Simscape unit names are defined in the pm_units.m file, which is shipped with the
product. You can open this file to see how the physical units are defined in the product,
and also as an example when adding your own units. This file is located in the directory
matlabroot\toolbox\physmod\common\units\mli\m.

Default registered units and their abbreviations are listed in the following table. Use the
pm_getunits command to get an up-to-date list of units currently defined in your unit
registry. Use the pm_adddimension and pm_addunit commands to define additional
units.

Physical Unit Abbreviations Defined by Default in the Simscape Unit Registry


Quantity Abbreviation Unit
Acceleration gee Earth gravitational
acceleration (9.80665 m/s^2)
Amount of substance mol Mole
Angle rad Radian

deg Degree

rev Revolution
Angular velocity rpm Revolutions/minute
Capacitance F Farad

pF Picofarad

nF Nanofarad

uF Microfarad
Charge c Coulomb
Conductance S Siemens

nS Nanosiemens

uS Microsiemens

mS Millisiemens

11-4
Unit Definitions

Quantity Abbreviation Unit


Current A Ampere

pA Picoampere

nA Nanoampere

uA Microampere

mA Milliampere

kA Kiloampere
Energy J Joule

Btu British thermal unit

eV Electronvolt
Flow rate lpm Liter/minute

gpm Gallon/minute
Force N Newton

dyn Dyne

lbf Pound-force

mN Millinewton
Frequency Hz Hertz

kHz Kilohertz

MHz Megahertz

GHz Gigahertz
Inductance H Henry

uH Microhenry

mH Millihenry

11-5
11 Physical Units

Quantity Abbreviation Unit


Length m Meter

cm Centimeter

mm Millimeter

km Kilometer

um Micrometer

in Inch

ft Foot

mi Mile

yd Yard
Magnetic flux Wb Weber
Magnetic flux density T Tesla

G Gauss
Mass kg Kilogram

g Gram

mg Milligram

lbm Pound mass

oz Ounce

slug Slug
Pressure Pa Pascal

kPa Kilopascal

MPa Megapascal

GPa Gigapascal

11-6
Unit Definitions

Quantity Abbreviation Unit


bar Bar

kbar Kilobar

atm Atmosphere

psi Pound/inch^2

Power W Watt

uW Microwatt

mW Milliwatt

kW Kilowatt

MW Megawatt

HP Horsepower
Resistance Ohm Ohm

kOhm Kiloohm

MOhm Megaohm

GOhm Gigaohm
Temperature K Kelvin

C Celsius

Fh Fahrenheit

R Rankine
Time s Second

min Minute

hr Hour

ms Millisecond

11-7
11 Physical Units

Quantity Abbreviation Unit


us Microsecond

ns Nanosecond

Velocity mph Miles/hour

fpm Feet/minute

fps Feet/second
Viscosity absolute Poise Poise

cP Centipoise

reyn Reyn
Viscosity kinematic St Stokes

cSt Centistokes

Newt Newt
Volume l Liter

gal US liquid gallon

igal Imperial (UK) gallon


Voltage V Volt

mV Millivolt

kV Kilovolt

Note This table lists the unit abbreviations defined in the product. For information
on how to use the abbreviations above, or mathematical expressions with these
abbreviations, to specify units for the parameter values in the block dialogs, see “How to
Specify Units in Block Dialogs” on page 11-9.

11-8
How to Specify Units in Block Dialogs

How to Specify Units in Block Dialogs


Simscape block dialogs have drop-down combo boxes for units next to a parameter value.
For example, in the Constant Volume Chamber block dialog box, the drop-down list for
the Chamber volume parameter contains l, gal, in^3, ft^3, mm^3, cm^3, m^3, and
km^3, and the drop-down list for the Initial pressure parameter contains Pa, bar, psi,
and atm.

You can either select a unit from the drop-down list, or type a commensurate unit name
(or a mathematical expression with unit names) directly into the unit combo box of the
block dialog. You can use the abbreviations for the units defined in your registry, or
any valid mathematical expressions with these abbreviations. For example, you can
specify torque in newton-meters (N*m) or pound-feet (lbf*ft). To specify velocity, you
can use one of the defined unit abbreviations (mph, fpm, fps), or an expression based on
any combination of the defined units of length and time, such as meters/second (m/s),
millimeters/second (mm/s), inches/minute (in/min), and so on.

Note Affine units (such as Celsius or Fahrenheit) are not allowed in unit expressions. For
more information, see “About Affine Units” on page 11-11.

The following operators are supported in the unit mathematical expressions:

* Multiplication
/ Division
^ Power
+ Plus — for exponents only
- Minus — for exponents only
() Brackets to specify evaluation order

Metric unit prefixes, such as kilo, milli, or micro, are not supported. For example, if you
want to use milliliter as a unit of volume, you have to add it to the unit registry:
pm_addunit('ml', 0.001, 'l');

The drop-down lists next to parameter names are automatically populated by those
units that are commensurate with the unit of the parameter. If you specify the units by
typing, it is your responsibility to enter units that are commensurate with the unit of the

11-9
11 Physical Units

parameter. The unit manager performs error checking when you click Apply or OK in
the block dialog box, and issues an error if you type an incorrect unit.

In the Simulink-PS Converter and the PS-Simulink Converter block dialog boxes,
the drop-down lists are prepopulated with some common input and output units, and it
is your responsibility to select or type a unit expression commensurate with the expected
input or output units. The error checking for the converter blocks is performed at the
time of simulation. See “Model Validation” on page 4-7 for details.

11-10
Thermal Unit Conversions

Thermal Unit Conversions


In this section...
“About Affine Units” on page 11-11
“When to Apply Affine Conversion” on page 11-11
“How to Apply Affine Conversion” on page 11-12

About Affine Units


Thermal units often require an affine conversion, that is, a conversion that performs both
multiplication and addition. To convert from the old value Told to the new value Tnew, we
need a linear conversion coefficient L and an offset O:
Tnew = L * Told + O

For example, to convert a temperature reading from degrees Celsius into degrees
Fahrenheit, the linear term equals 9/5, and the offset equals 32:
TFahr = 9 / 5 * TCels + 32

Simscape unit manager defines kelvin (K) as the fundamental temperature unit. This
makes Celsius (C) and Fahrenheit (Fh) affine units because they are both related to
kelvin with an affine conversion. Rankine (R) is defined in terms of kelvin with a zero
linear offset and, therefore, is not an affine unit.

The following are the default Simscape unit registry definitions for temperature units:
pm_adddimension('temperature', 'K'); % defines kelvin as fundamental temperature unit
pm_addunit('C', [1 273.15], 'K'); % defines Celsius in terms of kelvin
pm_addunit('Fh', [5/9 -32*5/9], 'C'); % defines Fahrenheit in terms of Celsius
pm_addunit('R', [5/9 0], 'K'); % defines rankine in terms of kelvin

When to Apply Affine Conversion


In dealing with affine units, sometimes you need to convert them using just the linear
term. Usually, this happens when the value you convert represents relative, rather than
absolute, temperature, ΔT = T1 – T2.
ΔTnew = L * ΔTold

In this case, adding the affine offset would yield incorrect conversion results.

11-11
11 Physical Units

For example, the outdoor temperature rose by 18 degrees Fahrenheit, and you need
to input this value into your model. When converting this value into kelvin, use linear
conversion

ΔTkelvin = 5 / 9 * ΔTFahr

and you get 10 K, that is, the outdoor temperature changed by 10 kelvin. If you apply
affine conversion, you will get a temperature change of approximately 265 kelvin, which
is incorrect.

This is even better illustrated if you use degrees Celsius for the input units because the
linear term for conversion between Celsius and kelvin is 1:

• If the outdoor temperature changed by 10 degrees Celsius (relative temperature


value), then it changed by 10 kelvin (do not apply affine conversion).
• If the outdoor temperature is 10 degrees Celsius (absolute temperature value), then it
is 283 kelvin (apply affine conversion).

How to Apply Affine Conversion


When you specify affine units for an input temperature signal, it is important to consider
whether you need to apply affine conversion. Usually this decision depends on whether
the signal represents absolute or relative temperature (see “When to Apply Affine
Conversion” on page 11-11).

For example, you model a house-heating system, and you need to input the outdoor
temperature. In the following diagram, the Constant source block represents the average
outdoor temperature, in degrees Celsius, and the Sine source block adds the daily
temperature variation. The average outdoor temperature, in this case, is 12 degrees
Celsius. Daily variation with an amplitude of 8 makes the input outdoor temperature
vary between 4 and 20 degrees Celsius.

11-12
Thermal Unit Conversions

This signal is an absolute temperature reading. Therefore, when the signal converts into
kelvin for further computations, you need to specify that it should use affine conversion.
Double-click the Simulink-PS Converter block, type C in the Input signal unit field, and
select the Apply affine conversion check box.

11-13
11 Physical Units

As a result, the Simulink-PS Converter block outputs a value varying between 277 K and
293 K.

11-14
Angular Units

Angular Units
Simscape implementation of angular units relies on the concept of angular units,
specifically radians, being a unit but dimensionless. The notion of angular units being
dimensionless is widely held in the metrology community. The fundamental angular unit,
radian, is defined in the Simscape unit registry as:
pm_addunit('rad', 1, 'm/m');

which corresponds to the SI and NIST definition [1]. In other words, Simscape unit
manager does not introduce a separate dimension, 'angle', with a fundamental unit
of 'rad' (similar to dimensions for length or mass), but rather defines the fundamental
angular unit in terms of meter over meter or, in effect, 1.

The additional angular units, degree and revolution, are defined respectively as:
pm_addunit('deg', pi/180, 'rad');
pm_addunit('rev', 2*pi, 'rad');

As a result, forward trigonometric functions, such as sin, cos, and tan, work directly
with arguments expressed in angular units. For example, cosinus of 90 degrees equals
the cosinus of (pi/2) radians and equals the cosinus of (pi/2). Expansion of forward
trigonometric functions works in a similar manner.

Another effect of dimensionless implementation of angular units is the convenience of


the work-energy conversion. For example, torque (in N*m) multiplied by angle (in rad)
can be added directly to energy (in J, or N*m). If you specify other commensurate units
for the components of this equation, Simscape unit manager performs the necessary unit
conversion operations and the result is the same.

References
[1] The NIST Reference on Constants, Units, and Uncertainty, http://
physics.nist.gov/cuu/Units/units.html

11-15
11 Physical Units

Units for Angular Velocity and Frequency


Angular velocity units, such as rad/s, deg/s, and rpm, can also be used to measure
frequency for cyclical processes. This is consistent with frequency defined as revolutions
per second in a mechanical context, or cycles per second in an electrical context, and lets
you write frequency-dependent equations without requiring the 2*pi conversion factor.
In the SI unit system, however, the unit of frequency is hertz (Hz), defined as 1/s.

Simscape software defines the unit hertz (Hz) as 1/s, in compliance with the SI unit
system. This definition works well when frequency refers to a nonrotational periodic
signal such as the frequency of a PWM source. For cyclical processes, however, the block
equations have to contain the 2*pi conversion factor, to convert the numerical value
specified in Hz, or s-1, to angular frequency.

As a result, frequency units (based on Hz) and angular velocity units (based on rpm) are
not directly convertible, and using one instead of the other may result in unexpected
conversion factors applied to the numerical values by the block equations. For example,
the AC Voltage Source block explicitly multiplies the value you specify for its
Frequency parameter by 2*pi, to convert it to angular frequency before calculating the
sine function.

Drop-down lists of suggested units in block dialogs reflect this distinction. For example,
if a block has a Frequency parameter with the default unit of Hz, the drop-down list
for this parameter contains only units directly convertible to Hz (such as kHz, MHz, and
GHz) and does not contain the angular velocity units. Conversely, if you define a custom
block where the Frequency parameter has the default unit of rpm, its drop-down list of
suggested units will include deg/s and rad/s, but will not contain Hz, kHz, MHz, or GHz.

When you type a unit expression in the parameter units combo box (instead of selecting
a value from the drop-down list), the Simscape unit manager considers the units of
frequency and angular velocity to be commensurate. For example, when the default
parameter unit is Hz, you are able to type not only 1/s, but also expressions such as
deg/s and rad/s. This behavior is consistent with the Simscape implementation of
angular units (see “Angular Units” on page 11-15). It is your responsibility to verify that
the unit expression you typed works correctly with the block equations and reflects your
design intent.

Note: Prior to Release R2013a, the unit definition for Hz was rev/s. For information on
how to update legacy models and custom Simscape libraries written in R2012b or earlier,

11-16
Units for Angular Velocity and Frequency

see Compatibility Considerations under “Unit definition of Hz now consistent with SI”, in
the R2013a Release Notes.

11-17
12

Add-On Product License Management

• “About the Simscape Editing Mode” on page 12-2


• “Set the Model Loading Preference” on page 12-9
• “Save a Model in Restricted Mode” on page 12-11
• “Work with a Model in Restricted Mode” on page 12-14
• “Switch from Restricted to Full Mode” on page 12-28
• “Editing Mode Information” on page 12-30
12 Add-On Product License Management

About the Simscape Editing Mode

In this section...
“Suggested Workflows” on page 12-2
“What You Can Do in Restricted Mode” on page 12-3
“What You Can Do in Full Mode” on page 12-4
“Switching Between Modes” on page 12-4
“Working with Block Libraries” on page 12-7

Suggested Workflows
The Simscape Editing Mode functionality is implemented for customers who perform
physical modeling and simulation using Simscape platform and its add-on products:
SimDriveline, SimElectronics, SimHydraulics, SimMechanics, and SimPowerSystems. It
allows you to open, simulate, and save models that contain blocks from add-on products
in Restricted mode, without checking out add-on product licenses, as long as the products
are installed on your machine. It is intended to provide an economical way to distribute
simulation models throughout a team or organization.

Note Unless your organization uses concurrent licenses, see the Simscape product page
on the MathWorks Web site for specific information on how to install add-on products on
your machine, to be able to work in Restricted mode.

The Editing Mode functionality supports widespread use of Physical Modeling products
throughout an engineering organization by making it economical for one user to develop
a model and provide it to many other users.

Specifically, this feature allows a user, model developer, to build a model that uses
Simscape platform and one or more add-on products and share that model with other
users, model users. When building the model in Full mode, the model developer must
have a Simscape license and the add-on product licenses for all the blocks in the model.
For example, if a model combines Simscape, SimHydraulics, and SimDriveline blocks,
the model developer needs to check out licenses for all three products to work with it in
Full mode. Once the model is built, model users need only to check out a Simscape license
to simulate the model and fine-tune its parameters in Restricted mode. As long as no

12-2
About the Simscape Editing Mode

structural changes are made to the model, model users can work in Restricted mode and
do not need to check out add-on product licenses.

Another workflow, available with concurrent licenses only, lets multiple users, who all
have Simscape licenses, share a small number of add-on product licenses by working
mostly in Restricted mode, and temporarily switching models to Full mode only when
they need to perform a specific design task that requires being in Full mode.

Note MathWorks recommends that you save all the models in Full mode before
upgrading to a new version of Simulink or Simscape software.

If you have saved a model in Restricted mode and, upon upgrading to a new product
version, open the model and it does not run, switch it to Full mode and save. You can
then again switch to Restricted mode and work without problem.

What You Can Do in Restricted Mode


When your model is open in Restricted mode, you can:

• Simulate the model.


• Inspect parameters.
• Change certain block parameters. In general, you can change numerical parameter
values, but cannot change the block parameterization options. See the block reference
pages for specifics.
• Generate code.
• Make data logging or visualization changes.
• Add or delete regular Simulink blocks (such as sources or scopes) and appropriate
connections.

For other types of changes, listed in the following section, your model has to be in Full
mode. Some of these disallowed changes are impossible to make in Restricted mode (for
example, Restricted parameters are grayed out in block dialog boxes). Other changes, like
changing the physical topology of a model, are not explicitly disallowed, but if you make
these changes in Restricted mode, the software will issue an error message when you try
to run, compile, or save such a model.

12-3
12 Add-On Product License Management

What You Can Do in Full Mode


You need to open a model in Full mode if you need to do any of the following:

• Add or delete Physical Modeling blocks (that is, Simscape blocks or blocks from the
add-on product libraries).
• Make or break Physical connections (between Conserving or Physical Signal ports).
• Change the types of signals going into actuators or out of sensors (for example, from
velocity to torque).
• Change configuration parameters.
• Change block parameterization options and other restricted parameters.
• Change physical units of parameters.
• Protect a referenced model containing Physical Modeling blocks (for more information,
see “Protected Model”).

Switching Between Modes


The following flow chart shows what happens when you switch between modes.

12-4
About the Simscape Editing Mode

New models are always created in Full mode. You can then either save the model in Full
mode, or switch to Restricted mode and save the model in Restricted mode.

12-5
12 Add-On Product License Management

When you load an existing model, the license manager checks whether it has been saved
in Full or Restricted mode.

• If the model has been saved in Restricted mode, it opens in Restricted mode.
• If the model has been saved in Full mode, the license manager checks whether all the
add-on product licenses for this model are available and, if so, opens it in Full mode. If
a add-on product license is not available, the license manager issues an error message
and opens the model in Restricted mode. See also “Example with Multiple Add-On
Products” on page 12-6.

Note You can set a Simulink preference to specify that the models are always to open in
Restricted mode, regardless of the way they have been saved.

When a model is open, you can transition it between Full and Restricted modes at any
time, in either direction:

• When you try to switch from Restricted to Full mode, the license manager checks
whether all the add-on product licenses for this model are available. If a add-on
product license is not available, the license manager issues an error message and the
model stays in Restricted mode. See also “Example with Multiple Add-On Products”
on page 12-6.
• No checks are performed when switching from Full to Restricted mode.

Note If a add-on product license has been checked out to open a model in Full mode, it
remains checked out for the remainder of the MATLAB session. Switching to Restricted
mode does not immediately return the license.

Example with Multiple Add-On Products

When you try to open a model in Full mode or to switch from Restricted to Full mode, the
license manager scans the model and attempts to check out the required add-on product
licenses as it encounters them in the model. If a license is not available, the license
manager issues an error message and the model stays in Restricted mode. The licenses
are checked out sequentially. As a result, if a model uses blocks from multiple add-on
products, some of the add-on product licenses may have already been checked out by the
time the license manager encounters an unavailable license. In this case, these add-on

12-6
About the Simscape Editing Mode

product licenses stay checked out until you quit the MATLAB session, even though the
model is in Restricted mode.

For example, consider a model that uses blocks from SimHydraulics and SimDriveline
libraries, but the user who tries to open it has only the SimDriveline license available.
It may happen that the license manager checks out a SimDriveline license first, and
then tries to check out a SimHydraulics license, which is not available. The license
manager then issues an error message and opens the model in Restricted mode, but the
SimDriveline license stays checked out until the end of the MATLAB session.

Working with Block Libraries


This section describes the specifics of working with block libraries while using the
Editing Mode functionality. These rules are applicable to any physical modeling blocks,
that is, blocks from all Simscape libraries, including the add-on products. In general, you
need to work in Full mode when you modify a library block. However, when you open
a model that references the modified block, you may work in Restricted mode, under
certain conditions. The following summary details the Editing Mode rules for modifying
and using library blocks:

• To add physical modeling blocks to a library block, you need to work in Full mode.

• If this library block had not previously contained physical modeling blocks, you
need to work in Full mode to load a preexisting model that uses this library block
or to drag this block to a model.
• If this library block had previously contained physical modeling blocks, you can
work in Restricted mode when loading a preexisting model that uses this library
block. However, you have to work in Full mode to drag this block from the library
to a model.
• To add external physical ports to a library block, you need to work in Full mode.

• You can work in Restricted mode when loading a preexisting model that uses this
library block.
• However, to connect these additional ports, you need to work in Full mode because
you are changing the model topology.
• To delete external physical ports from a library block, you need to work in Full mode.
If these ports were connected in a model saved in Restricted mode, loading the model
causes the topology to change, so you need to switch to Full mode to save or compile
the model.

12-7
12 Add-On Product License Management

Resolving Block Library Links

All Simscape blocks in your models, including the add-on products' blocks, must have
resolved block library links. You can neither disable nor break these library links. This
is a global requirement of Simscape platform, which is necessary to enforce the Editing
Mode rules for modifying and using library blocks, listed above. A model with broken
library links will neither compile nor save. You must restore all the broken block library
links for your model to be valid.

If you want to customize certain blocks and use them in your models, you must add these
modified blocks to your own custom library, then copy the block instances that you need
to your model.

Related Examples
• “Set the Model Loading Preference” on page 12-9
• “Save a Model in Restricted Mode” on page 12-11
• “Work with a Model in Restricted Mode” on page 12-14
• “Switch from Restricted to Full Mode” on page 12-28

More About
• “Editing Mode Information” on page 12-30

12-8
Set the Model Loading Preference

Set the Model Loading Preference


By default, when you load an existing model, the license manager checks whether it has
been saved in Full or Restricted mode and tries to open it in this mode. However, you can
set your preferences so that the models are always open in Restricted mode, regardless of
the way they have been saved.

1 On the MATLAB Toolstrip, click Preferences. The Preferences dialog box opens.
2 In the left pane of the Preferences dialog box, select Simscape. The right pane
displays the Editing Mode group box. By default, the Load models using option is
set to Editing mode specified in models.
3 Select Restricted mode always from the drop-down list, as shown, and click OK.

Now, when you open a model, the license manager does not attempt to check out add-on
product licenses and always opens the model in Restricted mode.

Related Examples
• “Save a Model in Restricted Mode” on page 12-11

12-9
12 Add-On Product License Management

• “Work with a Model in Restricted Mode” on page 12-14


• “Switch from Restricted to Full Mode” on page 12-28

More About
• “About the Simscape Editing Mode” on page 12-2
• “Editing Mode Information” on page 12-30

12-10
Save a Model in Restricted Mode

Save a Model in Restricted Mode


Rather than setting your preferences so that all the models always open in Restricted
mode, you can switch an individual model to Restricted mode before saving it. Such a
model will then, by default, open in Restricted mode.

1 From the top menu bar in the model window, select Simulation > Model
Configuration Parameters. The Configuration Parameters dialog box opens.
2 In the left pane of the Configuration Parameters dialog box, select Simscape. The
right pane displays the Editing Mode option, which is by default set to Full.
3 Select Restricted from the drop-down list, as shown, and click OK.

4 Save the model.

Note The Simscape entry does not appear in the left pane of the Configuration
Parameters dialog box until you add at least one Physical Modeling block to your model.
If you create an additional configuration set for a model, the Simscape entry does not
appear in it until you either activate it or perform a Physical Modeling operation, such as

12-11
12 Add-On Product License Management

adding or deleting a Physical Modeling block or connection, opening a Physical Modeling


block dialog box, and so on.

Once you have switched a model to Restricted mode, working with it follows the rules
described in “Work with a Model in Restricted Mode” on page 12-14. Note, however,
that the add-on product licenses for this model stay checked out until you quit the
MATLAB session.

When you open a model that has been saved in Restricted mode, the license manager
opens it in Restricted mode and does not check out the add-on product licenses.

Example of Saving a Model in Restricted Mode


In this example, you switch a model to Restricted mode and save it.

1 Open the Simple Mechanical System example model


(ssc_simple_mechanical_system).

12-12
Save a Model in Restricted Mode

2 From the top menu bar in the model window, select Simulation > Model
Configuration Parameters. The Configuration Parameters dialog box opens.
3 In the left pane of the Configuration Parameters dialog box, select Simscape. The
right pane displays the Editing Mode option, which is set to Full by default.
4 Select Restricted from the drop-down list and click OK.
5 Save the model as model_test_edit_mode.

Related Examples
• “Set the Model Loading Preference” on page 12-9
• “Work with a Model in Restricted Mode” on page 12-14
• “Switch from Restricted to Full Mode” on page 12-28

More About
• “About the Simscape Editing Mode” on page 12-2
• “Editing Mode Information” on page 12-30

12-13
12 Add-On Product License Management

Work with a Model in Restricted Mode


When you open a model in Restricted mode, you can perform a variety of tasks: simulate
the model, inspect and fine-tune block parameters, add and delete basic Simulink blocks,
and so on. For a complete list of allowed operations, see “What You Can Do in Restricted
Mode” on page 12-3.

When you open a block dialog box in Restricted mode, some of the block parameters
may be grayed out. These are the so-called restricted parameters that can be modified
only in Full mode. In general, you can change numerical parameter values in Restricted
mode, but you cannot change the block parameterization options. See the block
reference pages for specifics. Note also that when a restricted parameter defines the
block parameterization schema, nonrestricted parameters available for fine-tuning in
Restricted mode depend on the value of this restricted parameter. For example, in a
Constant Volume Chamber block, the Chamber specification parameter is restricted.
If, at the time the model entered Restricted mode, this parameter was set to By volume,
then the nonrestricted parameters available for fine-tuning would be Chamber volume,
Specific heat ratio, and Initial pressure. If, however, it was set to By length and
diameter, you will have a different set of parameters available in Restricted mode.

You cannot change physical units in Restricted mode. When you open a block dialog box
in Restricted mode, the drop-down lists of units next to a parameter name and value are
grayed out. When you open a PS-Simulink Converter or Simulink-PS Converter block
dialog box, the Unit parameter is grayed out.

The following examples illustrate operations allowed and disallowed in Restricted mode:

In this section...
“How to Simulate and Fine-Tune a Model in Restricted Mode” on page 12-14
“How to Add and Delete Simulink Blocks in Restricted Mode” on page 12-19
“Performing an Operation Disallowed in Restricted Mode” on page 12-24

How to Simulate and Fine-Tune a Model in Restricted Mode


This example shows how you can work with a model in Restricted mode by changing
certain parameter values and observing the simulation results.

1 Open the model_test_edit_mode model, which you saved in Restricted mode in


“Example of Saving a Model in Restricted Mode” on page 12-12. The model opens in
Restricted mode.

12-14
Work with a Model in Restricted Mode

2 Open the Lever C Position scope and simulate the model. The models runs and
simulates in Restricted mode.

12-15
12 Add-On Product License Management

3 Double-click the Wheel and Axle A block to open its dialog box. Notice that the
Mechanism orientation parameter is grayed out, because you cannot modify the
block driving direction in Restricted mode.

12-16
Work with a Model in Restricted Mode

4 Change the Wheel radius parameter value to 0.1.


5 Simulate the model again. Notice that the motion amplitude of node C became
smaller as a result of the wheel radius change.

12-17
12 Add-On Product License Management

6 Double-click the Mass block and change the Mass parameter value to 24.
7 Simulate the model. Notice that doubling the mass resulted in increased vibrations.

12-18
Work with a Model in Restricted Mode

How to Add and Delete Simulink Blocks in Restricted Mode


This example shows how you can change the model input signal in Restricted mode by
adding and deleting basic Simulink blocks.

1 Open the model_test_edit_mode model, which you saved in Restricted mode in


“Example of Saving a Model in Restricted Mode” on page 12-12. The model opens in
Restricted mode.

12-19
12 Add-On Product License Management

2 Open the Lever C Position scope and simulate the model.

12-20
Work with a Model in Restricted Mode

3 Double-click the Force Input subsystem to open it.

12-21
12 Add-On Product License Management

4 Inside the subsystem, delete the Signal Builder block named Force Input. Replace it
with a Sine Wave block from the Simulink Sources library, as shown below.

12-22
Work with a Model in Restricted Mode

5 Simulate the model again. The model successfully compiles and simulates in
Restricted mode.

12-23
12 Add-On Product License Management

Performing an Operation Disallowed in Restricted Mode


This example shows what happens when you perform an operation that is disallowed in
Restricted mode.

1 Open the model_test_edit_mode model, which you saved in Restricted mode in


“Example of Saving a Model in Restricted Mode” on page 12-12. The model opens in
Restricted mode.

12-24
Work with a Model in Restricted Mode

2 Double-click the P subsystem to open it.

12-25
12 Add-On Product License Management

3 Delete the connection line between port P of the Ideal Translational Motion Sensor
block and the PS-Simulink Converter block. Instead, connect port V of the Ideal
Translational Motion Sensor block to the input port of the PS-Simulink Converter
block, to measure the velocity on node C of the lever.

12-26
Work with a Model in Restricted Mode

4 Try to simulate the model. An error message appears saying that the model cannot
be compiled because its topology has been changed while in Restricted mode. You
can either undo the changes, or switch to Full mode, as described in “Switch from
Restricted to Full Mode” on page 12-28.

Related Examples
• “Set the Model Loading Preference” on page 12-9
• “Save a Model in Restricted Mode” on page 12-11
• “Switch from Restricted to Full Mode” on page 12-28

More About
• “About the Simscape Editing Mode” on page 12-2
• “Editing Mode Information” on page 12-30

12-27
12 Add-On Product License Management

Switch from Restricted to Full Mode


If you need to perform a task that is disallowed in Restricted mode, you can try to switch
the model to Full mode.

1 From the top menu bar in the model window, select Simulation > Model
Configuration Parameters. The Configuration Parameters dialog box opens.
2 In the left pane of the Configuration Parameters dialog box, select Simscape. The
right pane displays the Editing Mode option.
3 Select Full from the drop-down list, as shown, and click OK.

The license manager checks whether all the add-on product licenses for this model
are available. If yes, it checks out the add-on product licenses and switches the model
to Full mode. If a add-on product license is not available, the license manager issues
an error message and the model stays in Restricted mode.

12-28
Switch from Restricted to Full Mode

Note If the switch to Full mode fails but some of the add-on product licenses have
already been checked out, they stay checked out until you quit the MATLAB session. For
more information, see “Example with Multiple Add-On Products” on page 12-6.

Once the model is switched to Full mode, you can perform the needed design and
simulation tasks, and then either save it in Full mode, or switch back to Restricted mode
and save it in Restricted mode.

Related Examples
• “Set the Model Loading Preference” on page 12-9
• “Save a Model in Restricted Mode” on page 12-11
• “Work with a Model in Restricted Mode” on page 12-14

More About
• “About the Simscape Editing Mode” on page 12-2
• “Editing Mode Information” on page 12-30

12-29
12 Add-On Product License Management

Editing Mode Information


In this section...
“What Is the Current Mode?” on page 12-30
“Which Licenses Are Checked Out?” on page 12-30

What Is the Current Mode?


If you are unsure whether the model is currently open in Restricted or Full mode, you
can check by following these steps.

1 From the top menu bar in the model window, select Simulation > Model
Configuration Parameters. The Configuration Parameters dialog box opens.
2 In the left pane of the Configuration Parameters dialog box, select Simscape. The
right pane displays the Editing Mode option, which is either Full or Restricted.
3 At this point, you can either try switching the mode by selecting a different option
from the drop-down list, or click Cancel to stay in the current mode.

Which Licenses Are Checked Out?


Use the MATLAB license command to get a list of all the licenses currently in use. In
the MATLAB Command Window, type
license('inuse')

This command returns a list of licenses checked out in the current MATLAB session. In
the list, products are listed alphabetically by their license feature names.

Related Examples
• “Set the Model Loading Preference” on page 12-9
• “Save a Model in Restricted Mode” on page 12-11
• “Work with a Model in Restricted Mode” on page 12-14
• “Switch from Restricted to Full Mode” on page 12-28

More About
• “About the Simscape Editing Mode” on page 12-2

12-30

You might also like