General Purpose Relay: Ordering Information
General Purpose Relay: Ordering Information
General Purpose Relay: Ordering Information
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., MK3P5-S-AC120).
Part number
Mechanical Mechanical indicator
Type Terminal Coil Contact form indicator & push-to-test button
Standard Plug-in AC/DC DPDT MK2P-I MK2P-S
3PDT MK3P-5-I MK3P-5-S
LED indicator DPDT MK2PN-I MK2PN-S
3PDT MK3PN-5-I MK3PN-5-S
LED indicator and diode DC DPDT MK2PND-I MK2PND-S
3PDT MK3PND-5-I MK3PND-5-S
LED indicator and varistor AC DPDT MK2PNV-I MK2PNV-S
3PDT MK3PNV-5-I MK3PNV-5-S
Diode DC DPDT MK2PD-I MK2PD-S
3PDT MK3PD-5-I MK3PD-5-S
Varistor AC DPDT MK2PV-I MK2PV-S
3PDT MK3PV-5-I MK3PV-5-S
Note: 1. Reverse polarity versions available on DC coil types. Consult your OMRON representative for further information.
2. VDE approved versions are available. Consult your OMRON representative for further information.
Part number
Relay type Socket Relay hold-down clip Mounting track/end plate
SPDT PF083A-E PFC-A1 PFP-100N or PFP-50N and
DPDT PFP-M (end plate)
3PDT PF113A-E PFC-A1 PFP-100N or PFP-50N and
PFP-M (end plate)
MK MK
■ ACCESSORIES (continued)
Back connecting sockets
Part number
Relay type Socket Relay hold-down clip
SPDT PL08 PLC-E
DPDT PLE08-0 PLC-10
PL08-Q PLC-E
3PDT PL11 PLC-E
PLE11-0 PLC-10
PL11-Q PLC-E
Specifications
■ CONTACT DATA
Resistive load (p.f. = 1)
Load 2 Pole 3 Pole Inductive load (p.f. = 0.4)
Rated load 10 A at 250 VAC 10 A at 120 VAC 7 A at 250 VAC
10 A at 28 VDC 10 A at 28 VDC
10 A at 250 VAC
Contact material Ag
Carry current 10 A
Max. operating voltage 250 VAC, 250 VDC
Max. operating current 10 A
Max. switching capacity 2,500 VA 2,500 VA/1,250 VA (NO/NC contacts) 1,750 VA
280 W 280 W
Min. permissible load 10 mA at 1 VDC
■ COIL DATA
AC
DC
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±15% for DC
rated current and +15%, -20% for AC rated current.
2. The rated current is reference value.
3. Performance characteristic data are measured at a coil temperature of 23°C (73°F).
4. For models with the LED indicator built-in, add an LED current of approximately 0 thru 5 mA to the rated current.
2
MK MK
■ CHARACTERISTICS
Contact resistance 50 mΩ max.
Operate time AC: 20 ms max. DC: 30 ms max.
Release time 20 ms max.
Operating frequency Mechanical 18,000 operations/hour
Electrical 1,800 operations/hour (under rated load)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of same poles, between
terminals of the same polarity
2,500 VAC, 50/60 Hz for 1 minute between current-carrying parts, noncurrent-
carrying parts, and terminals of opposite polarity
Vibration Mechanical durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
Malfunction durability 10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Shock Mechanical durability 1,000 m/s2 (approx. 100 G)
Malfunction durability 100 m/s2 (approx. 10 G)
Ambient temperature Operation: -10° to 40°C (14° to 104°F)
Humidity 35 to 85% RH
Service Life Mechanical 10 million operations min. (at operating frequency of 18,000 operations/hour)
Electrical 100,000 operations at rated load (at operating frequency of 1,800 operations/hour)
Weight Approx. 0.85 g (3.0 oz)
■ CHARACTERISTIC DATA
Maximum switching capacity Electrical service life
MK2P-S, MK3P5-S MK2P-S, MK3P5-S
Service life (x 106 operations)
Rated operating current (A)
3
MK MK
Dimensions
Unit: mm (inch)
■ RELAYS
Varistor type (AC coil) LED indicator and diode type (DC coil)
MK2PV-I, -S MK3PV-5-I, -S MK2PND-I, -S MK3PND-5-I, -S
4
MK MK
■ ACCESSORIES
Track mounted socket
PF083A-E (conforming to DIN EN 50022) Terminal Mounting Mounting dimensions
arrangement holes of relay with socket
Mounting holes PL08 type sockets and MK2 relay Recommended PCB layout
PL08 Total height dimension PLE08-0
5
MK MK
Unit: mm (inch)
■ ACCESSORIES (continued)
Back connecting socket Printed circuit
MK3 sockets (11 pin) board socket
PL11 (UL File No. E87929) PL11-Q PLE11-0
Solder terminals Wire wrap terminals
Mounting holes PL11 type sockets and MK3 relay Recommended PCB layout
PL11 Total height dimension PLE11-0
Mounting tracks
PFP-100N/PFP-50N PFP-100N2
(conforming to DIN EN 500022) (conforming to DIN EN 500022)
Note: Use of Type PFP-M end plate is recommended to secure the socket on the mounting track. Be sure that the engraved arrow
mark on the surface of the end plate faces upward and then tighten the screw firmly with a screwdriver.
6
MK MK
■ APPROVALS
UL (File No. E41515)/CSA (File Nos. LR41408 and LR335535)
SEV, DEMKO
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance
characteristics individually defined in this catalog.
2. VDE, Nemko and Semko versions are available. Please consult your OMRON representative for further information.
3. In the interest of product improvement, specifications are subject to change.
Cat. No. GC RLY6 9/97 Specifications subject to change without notice. Printed in the U.S.A.