Danson - Brosura Aparat Ventilatie HEYER iTernIS BASE

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

INTENSIVE CARE VENTILATION

Picture with optional accessories


THE ECONOMICAL SOLUTION FOR RELIABLE VENTILATION

Design Features
HEYER iTernIS BASE’s 12-inch touch-screen display combines comprehensive, easy-to-follow user interface and patient
monitoring.
User-friendly, intuitive programming promotes patient safety through redundancy:
Touch screen for rapid navigation
Illuminated retro-dial for navigation and confirmation
Rapid-access keys for access to critical functions
High visibility alarm indicator offers added patient safety.

Precise Control and Monitoring


Expanded flow trigger range and accuracy improves patient-ventilator synchrony
Comprehensive Respiratory Mechanics monitor offers continuous display of critical ventilation
parameters such as mandatory and spontaneous minute ventilation, spontaneous respiratory rate,
auto-PEEP, static and dynamic compliance, inspiratory and expiratory resistance, maximum
inspiratory pressure (PiMAX), leaks, trapped volume, airway occlusion pressure (P0.1), slow vital
capacity and P-V inflection points (P/VFLEX).
Separate Respiratory Mechanics menu offers a vital information tool to improve patient treatment
efficacy and safety.

Non-invasive Ventilation
Automatic leak compensation allows accurate and efficient
NIV for all patients.
Customizable alarm system allows deactivation of nuisance
alarm during NIV.
Reliable and accurate volume and leak monitoring assures patient-
ventilator synchrony and overall patient comfort.

Picture with optional accessories


SPECIFICATIONS

General Compressor DHR280 optional


Adult X Air Inlet Filter X
Pediatric X VADI Filters optional
Neonatal optional Filters Heater optional
Display Color 12" - Touch Screen Power cord 110/220
Ventilation modes Monitoring
VCV X Peak pressure X
PCV X Plateau X
PSV/CPAP X Mean Pressure X
SIMV(VCV) + PSV X PEEP X
SIMV(PCV) + PSV X Peak Flow X
MMV + PSV X (Adult/Ped) Inspiratory time X
PSV + Vt assured X (Adult/Ped) Expiratory time X
APRV X I:E Ratio X
NIV X (Adult/Ped) Total Rate X
PRVC - Spontaneous Rate X
TCPL optional with Neo Expired Tidal Volume X
TCPL + SIMV optional with Neo Total Expired Minute Volume X
Nasal CPAP optional with Neo Mandatory Expired Minute Volume X
Ventilation Settings Spontaneous Expired Minute Volume X
Tidal Volume 20 - 2500 ml (from 5 with Neo) F/VT X
Minute Volume 1 - 45 L/min Work of Breathing X
Controlled Pressure 2 - 100 cmH2O Leak X
Support Pressure 0 - 100 cmH2O % Leakage X
Peak Flow 180 L/min Endotracheal pressure -
PEEP/CPAP 0 - 50 cmH2O ETCO2 -
Breath Rate 1 - 150 BPM Vd/Vt -
Inspiratory Time 0,1 - 3 s (30 s APRV) Anatomic Dead space -
I:E Ratio 5.9:1 to 1:599 Va -
Triggering Flow / Pressure Va min -
Flow 0,2 - 15 L/min VtCO2 -
Pressure 0,5 - 20 cmH2O VCO2(STPD) -
Adjustable end inspiration criteria PSV 5 - 80% PeCO2 -
Inspiratory Flow 0,1 - 180 L/min Graphics
Continued Flow 2 - 40 L/min (optional with Neo) Pressure vs Time X
TCPL 2 - 50 cmH2O (optional with Neo) Volume vs Time X
FiO2 21 - 100 % Flow vs Time X
Inspiratory Pause up to 2 s Volume vs Pressure X
Flow waves 2 Flow vs Volume X
Others Features Flow vs Pressure X
Capnography - PeCO2 vs Time -
Trends 72hs PeCO2 vs Volume -
Autoscale X Respiratory Mechanics
Nebulizer X AutoPEEP X
Manual trigger X Static and Dynamic Compliance X
Inspiratory/Expiratory Pause X Inspiratory and Expiratory Resistance X
Oxygen sensor integrated Trapped Volume X
Activated Alarms log X Slow Vital Capacity X
Tube compensation - P 0.1 X
Leak compensation X Inflexion Points of the P/V curve X
Vt according Ideal body weight (IBW) X PImax X
Volume compensation by: Physiological VD/VT -
Altitude X Alarms
Circuit compliance X High/Low Inspiratory Pressure X
BTPS X Low inlet Pressure X
Accessories Power Loss X
CO2 sensor - Depleted Battery X
Reusable CO2 Adaptador - Continuous Pressure X
Proximal Flow sensor - Inoperant Ventilator X
Patient circuit (optional configuration) Adult/Ped/Neo Disconnection X
Hytrel or Silicone High/Low Tidal Volume X
Nebulizer X O2 Concentration High/Low X
AeroNeb Pro optional Apnea X
Humidifier MR810/MR850 optional NIV Leak X
Humidifier Chamber Adult/Neo optional Fan Failure X
Test Lung Silicone High Breath Rate X
Trolley w/ flex arms optional Low PEEP X
High pressure tubes optional High/Low Exhalated minute Volume X
Data Acquisition Software optional High/Low ETCO2 -

HEYER MEDICAL AG
CARL-HEYER-STR. 1/3
D-56130 BAD EMS / GERMANY
Subject to changes without notice!
PHONE: +49 2603 791 3 - FAX: +49 2603 70424 July 2012
[email protected] - WWW.HEYERMEDICAL.DE