T1 PCM Ind DS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

KMT - Kraus Messtechnik GmbH

Gewerbering 9, D-83624 Otterfing, Germany,  08024-48737, Fax. 08024-5532


Home Page http://www.kmt-telemetry.com, Email: [email protected]

T1-PCM-IND
Digital telemetry system for strain gage
applications on rotating shafts

• Easy to assemble and operate • Distance up to 30mm (Range)

• Strain gage sensors (>=350 Ohm) • Powering of transmitter part inductive

• Full- and half bridge configuration • No influence through radio frequency

• Excitation fixed 4 Volt DC • Many systems can operated at the same time

• Auto-Zero adjustment • Signal bandwidth 0…1200Hz (-3dB)

• Gain: 250-500-1000-2000 or 1000-2000-4000-8000 • Output +/-10V

• 16 bit ADC • Output 4-20mA (Option)

• Digital transmission realized inductively • System accuracy <0.2%


General description
The T1-PCM-IND single-channel telemetry system offers the easiest handling for the wireless transmission of strain gage
signals from rotating shafts. The encoder 35x24x14mm with a weight of 16g. The transmitter (encoder) part is simply mounted
on the rotating shaft with a special fiber reinforced tape.
The data transfer between transmitter and receiver is digital. The powering of the transmission part by the T1-PCM-IND is
inductive!.
Functional description
The T1-PCM-IND transmitter provides a pulse code modulated signal (PCM) to an induction winding around the shaft. The
magnetic field of this winding enables the inductive transmission of the signal from coil to pickup. From there the signal is
transferred by cable (5 m) to the receiver. The maximum distance between the transmitter coil and the pickup/powerhead is
30mm.
The receiver unit offers a BNC connector at the front panel with analog outputs  10 V and optional a current output of 4-20mA
Strain gage sensors (>=350 Ohm) in full- and half- bridge configuration can be directly connected to the transmitter. The
excitation is fixed to 4 Volt DC and the gain is set by plug-In bridge in 4 steps (250-500-1000-2000 or 1000-2000-4000-8000).
An auto-zero (AZ) adjustment is executed by pressing the AZ button on the front side of the receiver. The successful AZ
operation is indicated by a yellow LED. The yellow LED flashes as long as the AZ is in progress. When the AZ completes the
LED continuously illuminates. The AZ setting is stored in a Flash-RAM and thus is not lost during power-off.
T1-PCM-IND set contains:

Inductive Pickup/Powerhead T1-PCM-DEC Mounting tape Ferrite tape - 30mm x 3 meter


with 5m cable (Decoder) 2 x 25mm x 50m (isolate magnetic field between
shaft and coil)

CUL wire
0.5mm for coil
(Enamelled copper
wire)

T1-PCM-STG-(IND) Hexagon key to


DC-Power cable (Encoder for strain gages) activate AZ switch

Version 2019-05 Technical Data are subject to change without notice!


2
Technical data transmitting part:

T1-PCM-STG
Strain gage: Full and half bridge >=350 Ohm,
Excitation: 4 VDC (fixed)
Gain: 250-500-1000-2000 standard
1000-2000-4000-8000 on request!
Gain and Sensitivity
Gain 250 = +/-10mV/V Gain 2000 = +/-1.250mV/V
Gain 500 = +/-5mV/V Gain 4000 = +/-0.625mV/V
Gain 1000 = +/-2.5mV/V Gain 8000 = +/-0.3125mV/V
AZ: Auto Zero calibration (via AZ button from receiver side)
Analog signal bandwidth: 0 - 1200 Hz (-3 dB)
Operating temperature: - 40 to + 85 °C
Resolution 16bit
Scanning rate 6.41 kHz
Static acceleration: up to 3000g
Powering: inductive
Dimensions: 35x24x14mm, weight 16g
Housing: splash-water resistant IP65 (except the connector pins)

T1-PCM-Pt100
Pt100 thermo sensor
Measurement range -50 to 250°C or -50 to 500°C (select by jumper)
Analog signal bandwidth: 0 - 10 Hz (-3 dB)
Operating temperature: - 40 to + 85 °C
Resolution 16bit
Scanning rate 6.41kHz
Static acceleration: up to 3000g
Powering: inductive
Dimensions: 35x24x14mm, weight 16g
Housing: splash-water resistant IP65 (except the connector pins)

Version 2019-05 Technical Data are subject to change without notice!


3
Technical data receiving part
T1-PCM-DEC
Analogue output: +/-10V via BNC output 1200Hz
(delay between analog IN/OUT 1.8mS constant!!)
Optional add. 4-20mA output to the analog output
Auto Zero setting: via AZ button
Autozero LED:
Yellow ON- successful AZ
Yellow OFF- not successful AZ
if flashing, call support of KMT, error in EPROM
SL LED: Red ON = if error of data transmitting
SL LED: Red Flashing = distance to far
Power ON LED: Red ON = if power switch on
Output to Powerhead: via 6-pol. Tuchel
Fuse LED: Flashing if fuse is defect
Front Rear Powering: 10-30V DC, Input via 7-pol. Tuchel
Switch: ON/OFF
Operating temperature: - 40 to +70 °C
Dimensions: 75 x 105 x 105 (without connectors!)
Optional top-hat rail clip
Weight 750 grams
Static acceleration: up to 200g
System accuracy*: +/- 0.2 %
<*measure with gain 1000, 350ohm (0.1%) full bridge - test bridge!!>
T1-PCM-Pickup/Powerhead (standard version) other on request!!
Function: Receiving inductive PCM modulated data from the coil of
the T1-PCM-STG unit
Inductive frequency is 60kHz
Distance between the transmitter coil and the pickup is 5-30*mm
Output to T1-PCM-Decoder: Via 6-pol. Tuchel plug incl. 5m cable
Operating temperature: - 40 to +80 °C
Dimensions: 53x66x30mm (without cable)
Weight: 200 grams (without cable!)
Housing: splash-water resistant IP65 (except connector).
Cable length standard 5m! Optional 10, 15, 20 or 25m
*(depend of shaft diameter!)

Version 2019-05 Technical Data are subject to change without notice!