0% found this document useful (0 votes)
110 views1 page

Wind - Loading For CW3 PDF

This document calculates wind loads for a curtain wall structure based on Indian wind code CP3: Chapter V : Part 2 :1972. It provides the basic wind speed, design wind speed, dynamic pressure, and external pressure coefficients to determine wind loads. The structure has dimensions of 160m long, 20m high, and 80m wide. The general pressure coefficient is 1.00 and suction coefficients are -1.20 at corners and -0.80 at general areas. This results in wind loads of 0.80 kN/m2 for pressure and -0.90 kN/m2 and -0.60 kN/m2 for suction.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
110 views1 page

Wind - Loading For CW3 PDF

This document calculates wind loads for a curtain wall structure based on Indian wind code CP3: Chapter V : Part 2 :1972. It provides the basic wind speed, design wind speed, dynamic pressure, and external pressure coefficients to determine wind loads. The structure has dimensions of 160m long, 20m high, and 80m wide. The general pressure coefficient is 1.00 and suction coefficients are -1.20 at corners and -0.80 at general areas. This results in wind loads of 0.80 kN/m2 for pressure and -0.90 kN/m2 and -0.60 kN/m2 for suction.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

WIND LOAD CALCULATION FOR CW-3 ALL AREA

DYNAMIC WIND SPEED BASED ON CP3: CHAPTER V : PART 2 :1972

Basic Wind Speed V = 33 m/sec


Design Wind Speed Vs = V*S1*S2*S3
Where S1 = Topography factor
S2 = Ground rougnness factor
Class A Roughness 2
S3 = Statistical factor
Dynamic pressure q = K*(Vs)2
K 0.613
Calculation of Dynamic wind Pressure q:

H V S1 S2 S3 Vs K q
(m) m/sec m/sec kN/m2

12.5 33 1 0.97 1.1 35.03 0.613 0.75


33 1 0.72 1 23.76 0.613 0.346

EXTERNAL PRESSURE COFFICIENT Cpe FOR VERTICAL WALL

Refer Table 7 Pressure Coefficient Cpe for walls of rectangular Clad Building

α
B l
A h

l = 160 m
h = 20 m
w
w = 80 m

h/w = 0.25 h/w<=1/2


l/w = 2.00 3/2<l/w<=4

Building Building
Cpe(pressure) General = 0.70 Height Ratio Plan Ratio
Cpe(Suction) Local = -1 h/w<=1/2 3/2<l/w<=4
Cpe(Suction) General = -0.60 Wind Cpe for Surface Local
angle α A B C D Cpe
ABC& D
Location of Curtain wall 0 0.70 -0.25 -0.60 -0.60
-1
Faces A&B 90 -0.50 -0.50 0.70 -0.10
C& D
Include Local Pressure coefficient
Exclude Local Pressure coefficient
Cp = Cpe - Cpi where Cpi = 0.2
or -0.3

Cp (pressure) @ General Areas = 0.7- (-0.3) = 1.00


Cp (Suction) @ corners = -1- (0.2) = -1.20
Cp (Suction) @ General Areas = -0.6- (0.2) = -0.80
(kN/m2)
Wind Load (pressure) @ General Areas Cpxq = 1x0.75 = 0.80
Wind Load (Suction) @ corners Cpxq = -1.2x0.75 = -0.90
Wind Load (Suction) @ General Areas Cpxq = -0.8x0.75 = -0.60