Bond-Dek™
Composite Deck
Thickness (mm) Area of steel per Minimum reduced Reduced “I” per Effective depth of Neutral axis from
Mass per square
meter width of cross “Z” per meter width meter width Bond-Dek™ bottom of
Nominal Effective meter (kg/m2)
section (mm2) (103mm3) (105mm4) (mm) Bond-Dek™ (mm)
0,8 0,76 993 7,8 22,2 0,884 74,76 35,05
2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,25 4,50
140 2,52 10,00 8,72 7,80 6,84 6,10 5,37 4,80
150 2,75 10,00 9,61 8,60 7,53 6,70 5,93 5,30
160 2,99 10,00 10,00 9,39 8,21 7,29 6,46 5,79
170 3,22 10,00 10,00 10,00 8,79 7,89 7,01 6,29
180 3,46 10,00 10,00 10,00 9,43 8,48 7,54 6,78 6,13
190 3,69 10,00 10,00 10,00 10,00 9,17 8,11 7,27 6,50 5,87
200 3,93 10,00 10,00 10,00 10,00 10,00 8,49 7,76 6,94 6,26 5,66 5,16
210 4,17 10,00 10,00 10,00 10,00 10,00 9,03 8,24 7,36 6,64 5,99 5,44
220 4,40 10,00 10,00 10,00 10,00 10,00 9,58 8,74 7,86 7,14 6,42 5,84
230 4,64 10,00 10,00 10,00 10,00 10,00 10,00 9,23 8,28 7,553 6,75 6,13
240 4,87 10,00 10,00 10,00 10,00 10,00 10,00 10,00 8,74 7,93 7,11 6,42
250 5,11 10,00 10,00 10,00 10,00 10,00 10,00 10,00 9,14 8,32 7,51 6,82
2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,25 4,50
140 2,53 10,00 8,73 7,81 6,84 6,11 5,38 4,81
150 2,77 10,00 9,61 8,60 7,53 6,70 5,93 5,30
160 3,00 10,00 10,00 9,40 8,21 7,30 6,46 5,80
170 3,24 10,00 10,00 10,00 8,79 7,89 7,01 6,29
180 3,48 10,00 10,00 10,00 9,43 8,48 7,54 6,78
190 3,71 10,00 10,00 10,00 10,00 9,07 8,06 7,27 6,49 5,86
200 3,95 10,00 10,00 10,00 10,00 10,00 8,49 7,76 6,94 6,26 5,66 5,16
210 4,19 10,00 10,00 10,00 10,00 10,00 9,03 8,24 7,36 6,64 5,99 5,44
220 4,42 10,00 10,00 10,00 10,00 10,00 9,59 8,74 7,81 7,04 6,33 5,74
230 4,66 10,00 10,00 10,00 10,00 10,00 10,00 9,23 8,24 7,42 6,72 6,13
240 4,89 10,00 10,00 10,00 10,00 10,00 10,00 10,00 8,59 7,83 7,07 6,43
250 5,13 10,00 10,00 10,00 10,00 10,00 10,00 10,00 8,98 8,22 7,46 6,82
2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,25 4,50
140 2,56 10,00 8,75 7,80 6,80 6,00 5,34 4,80
150 2,79 10,00 9,46 8,50 7,45 6,60 5,89 5,30
160 3,03 10,00 10,00 9,29 8,16 7,29 6,45 5,79
170 3,27 10,00 10,00 10,00 8,78 7,88 7,00 6,28
180 3,50 10,00 10,00 10,00 9,48 8,48 7,54 6,78
190 3,74 10,00 10,00 10,00 10,00 9,06 8,06 7,26 6,49 5,87
200 3,97 10,00 10,00 10,00 10,00 10,00 8,76 7,76 6,94 6,26 5,66 5,16
210 4,21 10,00 10,00 10,00 10,00 10,00 9,33 8,24 7,36 6,64 5,99 5,44
220 4,44 10,00 10,00 10,00 10,00 10,00 9,69 8,74 7,81 7,04 6,33 5,74
230 4,68 10,00 10,00 10,00 10,00 10,00 10,00 9,13 8,19 7,43 6,72 6,13
240 4,91 10,00 10,00 10,00 10,00 10,00 10,00 10,00 8,63 7,83 7,07 6,42
250 5,15 10,00 10,00 10,00 10,00 10,00 10,00 10,00 9,09 8,22 7,41 6,72
2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,25 4,50
140 2,52 19,53 17,48 16,01 14,47 13,29 12,13 11,21
150 2,75 19,85 19,22 17,62 15,90 14,85 13,33 12,34
160 2,99 20,19 20,19 19,20 17,32 15,84 14,52 13,44
170 3,22 20,51 20,51 20,51 18,57 17,13 15,72 14,57
180 3,46 20,84 20,84 20,84 19,93 18,41 16,91 15,69 14,64
190 3,69 21,17 21,17 21,17 21,17 19,84 18,15 16,80 15,57 14,56
200 3,93 21,50 21,50 21,50 21,50 21,50 19,08 17,32 16,61 15,52 14,56 13,76
210 4,17 21,84 21,84 21,84 21,84 21,84 20,29 19,03 17,62 16,47 15,42 14,55
220 4,40 22,16 22,16 22,16 22,16 22,16 21,48 20,15 18,73 17,59 16,44 15,51
230 4,64 22,50 22,50 22,50 22,50 22,50 22,50 21,26 19,74 18,54 17,30 16,30
240 4,87 22,82 22,82 22,82 22,82 22,82 22,82 22,82 20,81 19,50 18,20 17,10
250 5,11 23,15 23,15 23,15 23,15 23,15 23,15 23,15 21,77 20,46 19,16 18,06
2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,25 4,50
140 2,53 19,54 17,50 16,04 14,49 13,32 12,15 11,24
150 2,77 19,88 19,25 17,64 15,93 14,60 13,36 12,36
160 3,00 20,20 20,20 19,23 17,34 15,87 14,54 13,47
170 3,24 20,54 20,54 20,54 18,60 17,15 15,75 14,59
180 3,48 20,87 20,87 20,87 19,96 18,44 16,94 15,72 14,67
190 3,71 21,19 21,19 21,19 21,19 19,70 18,09 16,82 15,59 14,58
200 3,95 21,53 21,53 21,53 21,53 21,53 19,12 17,95 16,64 15,55 14,59 13,79
210 4,19 21,87 21,87 21,87 21,87 21,87 20,32 19,05 17,65 16,49 15,45 14,57
220 4,42 22,19 22,19 22,19 22,19 22,19 21,54 20,18 18,68 17,46 16,32 15,38
230 4,66 22,52 22,52 22,52 22,52 22,52 22,52 21,28 19,71 18,40 17,27 16,32
240 4,89 22,85 22,85 22,85 22,85 22,85 22,85 22,85 20,59 19,37 18,16 17,13
250 5,13 23,18 23,18 23,18 23,18 23,18 23,18 23,18 21,55 20,33 19,12 18,09
2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,25 4,50
140 2,56 19,58 17,58 16,07 14,46 13,19 12,13 11,27
150 2,79 19,91 19,04 17,51 15,83 14,47 13,34 12,39
160 3,03 20,24 20,24 19,10 17,29 15,90 14,56 13,50
170 3,27 20,58 20,58 20,58 18,62 17,18 15,78 14,64
180 3,50 20,90 20,90 20,90 20,06 18,46 16,97 15,74 14,69
190 3,74 21,24 21,24 21,24 21,24 19,73 18,13 16,87 15,64 14,62
200 3,97 21,56 21,56 21,56 21,56 21,56 19,57 17,97 16,67 15,57 14,62 13,81
210 4,21 21,89 21,89 21,89 21,89 21,89 20,81 19,08 17,67 16,52 15,47 14,60
220 4,44 22,22 22,22 22,22 22,22 22,22 21,72 20,20 18,71 17,48 16,35 15,40
230 4,68 22,55 22,55 22,55 22,55 22,55 22,55 21,15 19,66 18,43 17,30 16,35
240 4,91 22,87 22,87 22,87 22,87 22,87 22,87 22,87 20,68 19,39 18,18 17,15
250 5,15 23,21 23,21 23,21 23,21 23,21 23,21 23,21 21,75 20,36 19,06 17,96
Installation procedure
(read entire procedure before pouring concrete)
Bond-Dek™ panels act as framework for wet
concrete and reinforcing for the slab. To
commence installation the first Bond-Dek™
panel is placed in the required position with
the male interlocking rib pointing in the
direction of laying as per sketch below. Place
the female interlocking rib to the outside.
Place the interlocking female rib of the
second panel onto the male rib of the first
panel at an approximate 45° angle and then
lower panel down onto supports locking the
side lap together (see sketch, right). Repeat
for each additional panel.
End lapping of sheets
The standard procedure is to lap Bond-Dek™
and not to butt joint it. To end lap Bond-Dek™
panels cut back 25mm on male and female
interlocking ribs on the bottom panel then
overlap top panel. Fix with Top Speed screws
into beam to ensure lateral stability at
supports.
Structural steelwork
Bond-Dek™ panels can be conveniently fixed
to steel supports with either “Top Speed”
screws or shot driven fasteners. One fixing in
each pan is required.
Shear stud
If shear studs are to be used these should
be placed in the pan of the panel over a
beam. Where panels are end lapped, this lap
of 25 mm must be to one side of the beam,
allowing for shear stud to be positioned
through the centre of the beam and fixed
through the bottom panel (see sketch below).
Preventing concrete run out at Bond-Dek ends
Fixing to concrete
Side fixing to supporting structure
For “Fire Applications” of Bond-Dek™ floors, welded steel mesh reinforcement of 8 mm diameter steel bars at 200 mm centres in
each direction is required with minimum top cover along supports (typically on top of shear studs).
Pouring concrete
Boksburg Tel: (011) 898 2900 Fax: (011) 892 1455 Zambia Tel: +260967495541
Cape Town Tel: (021) 521 1900 Fax: (021) 556 6936 Botswana Tel: +267 3105761 Fax: +267 3105762
Durban Tel: (031) 538 0940/1/2 Fax: (031) 502 3764 Namibia Tel: +264(0)61 263890 Fax: +264(0)61 263890
East London Tel: (043) 731 1895/98 Fax: (043) 731 1926 Zimbabwe Tel: +263 4 774 699
Bloemfontein Tel: (051) 432 3724/6 Fax: (051) 432 3723 GRS Exports Tel: (011) 898 2900 Fax: (011) 892 1455
Rustenburg Tel: (014) 596 6121 Fax: 086 644 8344 Helm Engineering Tel: (011) 876 1300 Fax: (011) 876 1304
www.globalroofs.co.za
[email protected]