FlowWatch HMI Functionality List
FlowWatch HMI Functionality List
0
Date: 28-10-2010
VIEWER AND USER LEVEL LOGIN
Issued by: F. Lucchini
1. Introduction
This document describes the functionality available for HMI software when Viewer and User login are utilized.
All operation described are more detailed explained on the HMI user manual.
USER level give access to all required setting that make the user able to work, maintain, and update the configurations
of the system.
HMI SW for viewer level login is always supplied free of password. In any case password can be decided and applied
from the user if required.
Here below is showed the HMI main page
View results
Change the well profile in use in case of multiple well application (GOSP)
Retrieve/copy/mange the database containing the processed data/results
Prepare a well test report
View and manage historical results
Change the unit in use for presentation ad for report.
FLOWATCH MPFM Doc.: Rev. 1.0
Date: 28-10-2010
VIEWER AND USER LEVEL LOGIN
Issued by: F. Lucchini
Here is reported a snapshot of the DATABASEmenu from where is possible to access on the Database management
and report preparation.
FLOWATCH MPFM Doc.: Rev. 1.0
Date: 28-10-2010
VIEWER AND USER LEVEL LOGIN
Issued by: F. Lucchini
HMI SW for USER level login is normally supplied protected by default password (panini) or free of password. In any
case password can be changed and applied from the user if required.
Here below is showed the HMI main page
The operator as USER in addition to the already exposed functionality have the possibility to operate the following
operation/activities:
Enter on the TRASMITTER menu for change/verify the configuration of the analogue input of the Flow
Computer.
Enter on the FLUID PROPERTIES menu for change/verify the fluid properties like:
o Oil density and related gradients
o Water density and related gradients
o Oil permittivity and related gradients
o Water conductivity
o Gas specific gravity
Enter on the PVT PROPERTIES menu for change/verify the fluid properties like:
o Oil shrinkage factor and related gradients
o Gas compressibility factor and related gradients
o Gas in solution and related gradients
o Reference pressure and temperature for STD condition
Enter on the FEB (Field Electronic Board) CERTIFICATE menu for load/verify and change the calibration
parameters of the FEB in case of unit replacement
Enter on the SENSOR CERTIFICATE menu for load/verify and change the calibration parameters of the sensor
if required
Enter on the MECHANICAL DIMENSION menu for change and verify the mechanical dimension of the sensor if
required
Enter on the METER FACTOR menu for change and verify the field actor if required
This menu give the control of all fluid properties used con the
calculation of the flow rates and results.
FLOWATCH MPFM Doc.: Rev. 1.0
Date: 28-10-2010
VIEWER AND USER LEVEL LOGIN
Issued by: F. Lucchini
As the previous menu also this give the full control to the
operator to change and verify all the PVT properties involved
on the STD flow rate calculation.