0% found this document useful (0 votes)
236 views2 pages

Controller DULCOMETER Compact: Compact Yet Fully Equipped - The Basic Water Analysis Unit

The DULCOMETER® Compact controller is a one-channel PID controller that can monitor and control water parameters like pH, ORP, chlorine and conductivity. It has inputs for sensors and temperature measurement, outputs for control and alarms, and can be used for industrial and swimming pool water treatment applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
236 views2 pages

Controller DULCOMETER Compact: Compact Yet Fully Equipped - The Basic Water Analysis Unit

The DULCOMETER® Compact controller is a one-channel PID controller that can monitor and control water parameters like pH, ORP, chlorine and conductivity. It has inputs for sensors and temperature measurement, outputs for control and alarms, and can be used for industrial and swimming pool water treatment applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Controller DULCOMETER® Compact

Compact yet fully equipped - the basic water analysis unit

The DULCOMETER® Compact controller is a one-channel be used as an alarm or limit value or to control motor-driven
PID controller for the measured variables pH, ORP, chlorine metering pumps or solenoid valves. A digital input is used
and inductive conductivity. It can monodirectionally control to switch off the control or to process a sample water limit
the measured variable, monitor limit values and transmit contact by remote control. The impact of temperature
the measured value via an mA output, e.g. to a PLC. The on the measurements can be provided by temperature
mA output can optionally also be configured as a controlled measurement or by manual input. Menu-driven operation is
variable output. The controller has one pulse frequency output language-independent.
to control one metering pump. One output relay can optionally

Your benefits
■ Flexibility in the choice of measured variable with pH and ■ Safety through sensor monitoring of pH for glass breakage
ORP and line breakage
■ Always the optimum measured value resolution by auto- ■ Various installation options: wall-mounted, installation on
ranging with conductivity measurement an upright or in a control cabinet
■ Depending on the requirement, various display options for
conductivity, such as: Conductivity, TDS (Total Dissolved
Solids), salinity and specific resistance

Field of application
■ Measurement and control of water parameters in industrial
and process water treatment plants
■ Permeate monitoring in reverse osmosis systems
■ Measurement and control of the hygiene parameters in
swimming pools
Printed in Germany, 1-4-2020.

www.prominent.com
Controller DULCOMETER® Compact
Compact yet fully equipped - the basic water analysis unit

Technical Data
Measuring range pH: 0 ... 14
ORP: -1000 ... +1000 mV
Chlorine: 0.05 ... 5 ppm, intermittent metering up to 10 ppm, max. 12 h
Conductive conductivity: 0.5 µS/cm ... 20 mS/cm (auto-ranging)
Inductive conductivity with ICT 1: 200 µS/cm ... 1000 mS/cm (auto-ranging)
Inductive conductivity with ICT 2: 20 µS/cm ... 2000 mS/cm (auto-ranging)
Inductive conductivity with ICT 5: 200 μS/cm ... 2000 mS/cm (auto-ranging)
Resolution pH: 0.01 pH
ORP: 1 mV
Chlorine: 0.01 ppm
Conductivity: 0.1 µS/cm (depends on the measuring range)
Accuracy 0.5% of the upper range value
Temperature compensation range 0 ... 120 °C, chlorine 1 ... 45 °C
Control Monodirectional PID control with selectable control direction
Inputs Sensor input for the relevant measured variable
Temperature sensor input: pH: Pt 1000, chlorine and conductivity: Pt 100/ Pt 1000
1 digital input as a remote control input for the functions pause control / sample water fault
Outputs 1 pulse frequency output for the control of metering pumps
1 active 0/4…20 mA output configurable as a measured or control variable, max. load: 400 Ω
1 output relay used as a changeover contact, can be configured as an alarm, limit value or
pulse width-modulated control output for motor-driven metering pumps
Cell constant, conductive 0.05 ... 12.0 cm-1
conductivity
Voltage supply 100 ... 230 V, 50/60 Hz, 5 W
Permissible operating temperature -10 ... +60 °C
Enclosure rating IP 67, based on NEMA 4 X Indoor
Dimensions 135 x 125 x 75 mm (H x W x D)
Weight 0.5 kg

Printed in Germany, 1-4-2020.

ProMinent Group
[email protected] www.prominent.com