Written Exam With Answer Key
Written Exam With Answer Key
I. True or False
Direction: Tell whether the following statement is True or False. Write (T) if
it is True and (F) if it is False in the space provided.
_________1. Work instructions provides a detailed breakdown of instructions
required to carry out one or more steps or tasks in a procedure.
_________2. Terminal lugs are recommended for use with solid wire.
_________3. Philips Screw driver has a straight or flat tip.
_________4.Poor lighting and ventilation are examples of physical hazards.
_________5. OSH means Occupational Security and Health.
_________6. To control hazards and risks, it is necessary to conduct a hazard
assessment.
_________7. In a single phase induction motor, the resistance of the running
winding (RW) is higher than the starting winding (SW).
_________8. Wye-Delta reduced voltage starters are applicable only with
motors all nine motor leads available.
_________9. Before you test installed mechatronics devices, a report of
testing must be done.
_________10. Before you test installed mechatronics devices, a report of
testing must be done. Resistance checking of installed
mechatronics devices must be done before applying power.
A. I and IV only
B. I and II only
C. I, II and IV
D. I, II, III and IV
3. A megger is used to measure _______________.
A. reactance
B. current
C. specific gravity
D. insulation resistance
A. I only
B. I and II only
C. III only
D. I, II, and III
15. What is the first step in identifying the untagged terminal leads of
nine leads out three-phase induction motor?
A. Determine the starting and running winding
B. Determine whether the motor is connected in wye or delta
C. Check the resistance of terminal leads
D. Label the terminal leads
16. Are also known as signaling devices.
A. Input Devices
B. Output Devices
C. Processing Devices
D. Protective Devices
26. Which of the following points should be observed while working with
electro-pneumatic systems?
I. Use tools in operating electrical limit switch during fault
finding
II. Switch off the air and voltage supply before disconnecting
the circuit
III. Do not exceed the permissible working pressure
IV. Use only voltages of ≥ 24 V
A. I and II only
B. III and IV only
C. I, II, and III only
27. It is used to lubricate the compressed air with a fine fog of oil.
A. Oil-fog lubricator
B. Oil-fog regulator
C. Oil lubricator
D. Fog regulator
39. How could you say that the installed circuit is a good circuit?
A. The needle pointer deflects and reads zero
B. The needle pointer does not deflect
C. The needle pointer deflects to the right but not to zero
D. The needle pointer is in infinity
I. True or False
1. T
2. F
3. F
4. T
5. F
6. T
7. F
8. F
9. F
10. T