Starting Formulation 8014

Re-Issued July 2007

Hand Lay-up FRP Matrix


EPON™ Resin 862 / HELOXY™ Modifier 68 / EPIKURE™ Curing Agent 3234

Introduction This hand lay-up system allows for high filler loading due to its low viscosity. This capability
allows this system to be used both as a laminating resin and as an adhesive system.

Suggested Uses

Pipe fittings, flanges, man-ways, etc.

General aviation parts

General adhesive applications

Features

Low viscosity

Initial room temperature cure

Post-cure recommended for optimum performance

Excellent balance of physical and thermal properties

Chemical
Description •
EPIKOTE Resin 862 is a bisphenol F epoxy resin

HELOXY Modifier 68 is a difunctional reactive diluent

EPIKURE Curing Agent 3234 is a aliphatic amine

HCD-2320 (Rev. 7/31/2017 9:57:05 AM) Page 1 of 4


SF 8014 Hand FRP Matrix 862 68 3234

Formula Material Supplier Pounds Gallons


EPON Resin 862 Hexion 90 9.1
HELOXY Modifier 68 Hexion 10 1.1
EPIKURE Curing Agent 3234 Hexion 16 2.0
Total 116.0 12.2

Mixing Instructions EPON Resin 862 and HELOXY Modifier 68 may be blended in any ratio in order to adjust the
processing and performance. The 90/10 blending ratio by weight was selected to provide a
balance of processability and performance. Both components are low in viscosity and may
easily be blended at room temperature. Once the resin and the modifier have been blended,
then the curing agent should be added. Keep in mind that the gel time of EPIKURE Curing
Agent 3234 blended with this resin blend in a 100 gram mass is only 27 minutes. Please
plan accordingly.

For adhesive applications, the addition and thorough mixing of fillers, thixotropic agents, etc.
into the resin blend should be completed prior to the addition of the curing agent.

Composite The initial cure step should be carried out at room temperature. An elevated temperature
Fabrication / Hand post cure may not be necessary depending on the requirements of the desired application.
Lay-up However, an elevated temperature post cure is recommended for optimum performance.
Four hours at 82 °C (180 °F) was utilized to allow the use of low temperature tooling. The
post-cure may be performed freestanding depending on the part geometry and tolerance
required.

Typical Handling Table 1 / Handling Properties


Properties
Units Value

EPON Resin 862 pbw 90


HELOXY Modifier 68 pbw 10
EPIKURE Curing Agent 3234 pbw 16
Viscosity at 25 °C 1 cP 460
2
Gel time min. 27
1
BrookfieldDV-11, Spindle 31.
2
Shyodu Gel Timer, paper cup.

HCD-2320 (Rev. 7/31/2017 9:57:05 AM) Page 2 of 4


SF 8014 Hand FRP Matrix 862 68 3234

Typical Cured State Table 2 / Properties of Cast Matrix System 1


Properties
Method Units Value
2
Tg DSC, dry D-3418 °C (°F) 107 (225)
3
Tg DSC, wet °C (°F) 96 (205)
4
Tg DMA D-4065 °C (°F) 105 (221)
HDT (264 psi) D-648 °C (°F) 93 (200)
Tensile strength, Ultimate D-638 psi 10800
Tensile modulus ksi 442
Tensile elongation at break % 9.0
Flexural strength, Ultimate D-790 psi 17800
Flexural modulus ksi 471
Flexural elongation % 5.8
1
Cure Schedule: 12 hours at 25 °C (77 °F), 4 hours at 82 °C (180 °F).
2
Glass Transition Temperature; Differential Scanning Calorimetry, 20 °C/minute.
3
Wet conditioning: 7 days immersed in deionized water at 63 °C (145 °F).
4
Glass Transition Temperature; Dynamic Mechanical Analysis, 1 °C/minute.

Storage Recommendations regarding storage conditions can be obtained by visiting our web site at
www.hexion.com

General Information
These are starting formulations and are not proven in the user’s particular application but are simply meant to
demonstrate the efficacy of the products and to assist in the development of the user’s own formulation. It is the user’s
responsibility to fully-test and qualify the formulation, along with the ingredients, methods, applications or equipment
identified herein (“Information”), by the user’s knowledgeable formulator or scientist, and to determine the appropriate
use conditions and legal restrictions, prior to use of any Information.

Safety, Storage & Handling


Please refer to the MSDS for the most current Safety and Handling information.

Exposure to these materials should be minimized and avoided, if feasible, through the observance of proper
precautions, use of appropriate engineering controls and proper personal protective clothing and equipment, and
adherence to proper handling procedures. None of these materials should be used, stored, or transported until
the handling precautions and recommendations as stated in the Material Safety Data Sheet (MSDS) for
these and all other products being used are understood by all persons who will work with them. Questions
and requests for information on Hexion Inc. ("Hexion") products should be directed to your Hexion sales
representative, or the nearest Hexion sales office. Information and MSDSs on non-Hexion products should be
obtained from the respective manufacturer.

Contact Information
For product prices, availability, or order placement, please contact customer service:

HCD-2320 (Rev. 7/31/2017 9:57:05 AM) Page 3 of 4


www.hexion.com/Contacts/

For literature and technical assistance, visit our website at:


www.hexion.com

® and ™ Licensed trademarks of Hexion Inc.::LicensedTrademarkDisclaimer::

DISCLAIMER

The information provided herein was believed by Hexion Inc. (“Hexion”) to be accurate at the time of preparation or
prepared from sources believed to be reliable, but it is the responsibility of the user to investigate and understand
other pertinent sources of information, to comply with all laws and procedures applicable to the safe handling and use
of the product and to determine the suitability of the product for its intended use. All products supplied by Hexion are
subject to Hexion’s terms and conditions of sale. HEXION MAKES NO WARRANTY, EXPRESS OR IMPLIED,
CONCERNING THE PRODUCT OR THE MERCHANTABILITY OR FITNESS THEREOF FOR ANY PURPOSE
OR CONCERNING THE ACCURACY OF ANY INFORMATION PROVIDED BY HEXION, except that the product
shall conform to Hexion’s specifications. Nothing contained herein constitutes an offer for the sale of any product.

HSF-2320- (Rev.7/31/2017 9:57:04 AM)