Demo Frilo: Position: FD+-001
Demo Frilo: Position: FD+-001
Position: FD+-001
System Graphics
System Values
Member Concrete Steel Width (x) Width (y) Height (z)
m m m
Foundation C 45/55 B500B 3.50 4.50 0.50
Column C 45/55 B500B 0.50 0.70 1.40
Pocket, exterior 1.30 1.50 1.40
pocket, top 0.65 0.85 1.40
pocket, bottom 0.65 0.85 1.40
Ohne Grundwasser.Anchoring depth: 1.00m.
Stability : Lateral buckling analysis (EQU) Result Load Cases Theory 2nd order
No. at M Ed,dst M Ed,st η
m kNm kNm
2 x = 1.75 60.0 436.9 0.14
2 x = -1.75 0.0 479.7 0.00
2 y = 2.25 530.0 561.7 0.94
2 y = -2.25 0.0 940.3 0.00
η = M Ed,dst / M Ed,st = 530.0 kNm / 561.7 kNm = 0.94
Stability: Stabilizing and destabilizing moments around outer edges
The vertical component of earth pressure by anchoring depth is not considered.
Gaping joint Resulting Load Case Theory 1st Order and Theory 2nd Order
No. N ex ey a*/(1/6) b*/(1/9) ηG ηG,Q
kN m m
1I 0.0 0.00 0.00 0.000/0.167 0.00
1 II 0.0 0.00 0.00 0.000/0.111 0.00
1I 428.7 0.00 0.00 0.000/0.111 0.00
2 II 265.1 0.16 1.43 0.103/0.111 0.93
a*=ex/bx+ey/by b*=(ex/bx)²+(ey/by)² ηG=a*/(1/6) ηGQ=b*/(1/9)
The proof of gaping joint is reduced by reducing factors to characteristic level.
The angle of the characteristic resulting force in bearing pressure
The slope of the characteristic or representative soil pressure resulting has not been proved.
Design value of the bearing pressure resistance σ R,d = 350.0 kN/m²
The design value of soil pressure resistance has been specified directly.
Bearing Pressure
Check not done.
Safety against sliding
Check not done.
Demo Frilo Projekt: My Project
Stuttgarter Straße 40 Phone: 0711 810020 Position: FD+-001
70469 Stuttgart Fax: 0711 858020 07.12.2020 Seite: 6
Bearing Resistance Failure Load case 1 Theory 1st order - Soil values
x d ls φ' ls*φ' c' ls*c' A γ A*γ
m m m ° °m kN/m² kN/m m² kN/m³ kN/m
1 3.03 3.03 9.56 30.0 286.9 0.0 0.0 45.5 18.5 841.9
2 4.33 1.30 4.01 30.0 120.3 0.0 0.0 12.9 18.5 238.2
3 4.73 0.40 1.59 30.0 47.8 0.0 0.0 3.0 18.5 55.3
4 5.55 0.82 6.99 30.0 209.8 0.0 0.0 3.7 18.5 68.4
22.16 30.0 664.8 0.0 0.0 0.0 18.5 1,203.8
Bearing Resistance Failure Load case 1 Theory 1st order - Factors
N N0 ν i λ ζ
Nb 7.70 10.05 0.77 1.00 1.00 1.00
Nd 25.56 18.40 1.39 1.00 1.00 1.00
Nc 42.53 30.14 1.41 1.00 1.00 1.00
m a = 1.438 m b = 1.563 m = 1.563
Bearing Resistance Failure Load case 1 Theory 1st order - System
a' b' d s β γ1 γ2 c' φ' α pv
m m m m ° kN/m³ kN/m³ kN/m² ° ° kN/m²
4.50 3.50 1.00 0.00 0.0 18.5 18.5 0.0 30.0 0.0 0.0
DIN 4017:2006 - Bearing Resistance Failure Load case 1 Theory 1st order
d' N Ek T Ekx T Eky δ ω N Ed R n,k R n,d η
m kN kN kN ° ° kN kN kN
1.00 428.7 0.0 0.0 0.0 90.0 586.9 15,301.7 10,929.8 0.05
Bearing Resistance Failure Load case 1 Theory 2nd order - Soil values
x d ls φ' ls*φ' c' ls*c' A γ A*γ
m m m ° °m kN/m² kN/m m² kN/m³ kN/m
1 3.03 3.03 9.56 30.0 286.9 0.0 0.0 45.5 18.5 841.9
2 4.33 1.30 4.01 30.0 120.3 0.0 0.0 12.9 18.5 238.2
3 4.73 0.40 1.59 30.0 47.8 0.0 0.0 3.0 18.5 55.3
4 5.55 0.82 6.99 30.0 209.8 0.0 0.0 3.7 18.5 68.4
22.16 30.0 664.8 0.0 0.0 0.0 18.5 1,203.8
Bearing Resistance Failure Load case 1 Theory 2nd order - Factors
N N0 ν i λ ζ
Nb 7.70 10.05 0.77 1.00 1.00 1.00
Nd 25.56 18.40 1.39 1.00 1.00 1.00
Nc 42.53 30.14 1.41 1.00 1.00 1.00
m a = 1.438 m b = 1.563 m = 1.563
Bearing Resistance Failure Load case 1 Theory 2nd order - System
a' b' d s β γ1 γ2 c' φ' α pv
m m m m ° kN/m³ kN/m³ kN/m² ° ° kN/m²
4.50 3.50 1.00 0.00 0.0 18.5 18.5 0.0 30.0 0.0 0.0
DIN 4017:2006 - Bearing Resistance Failure Load case 1 Theory 2nd order
d' N Ek T Ekx T Eky δ ω N Ed R n,k R n,d η
m kN kN kN ° ° kN kN kN
1.00 428.7 0.0 0.0 0.0 90.0 586.9 15,301.7 10,929.8 0.05
Settlement
Check not done.
Demo Frilo Projekt: My Project
Stuttgarter Straße 40 Phone: 0711 810020 Position: FD+-001
70469 Stuttgart Fax: 0711 858020 07.12.2020 Seite: 7
Settlement
Check not done.
Durability
Requirements durability
top bottom
attack on concrete WF X0
attack on reinforc. XC2 XC2
min. concrete class C 16/20 C 16/20
long. reinforcement φ,m = 14 mm φ,m = 14 mm
allowance in design Δcdev = 15 mm Δcdev = 15 mm
reduced cmin >=C 16/20 >=C 16/20
longitudinal bars cmin,m = 15 mm cmin,m = 15 mm
concrete coverage cnom,m = 30 mm cnom,m = 30 mm
laying dist. link c,l > = 30 mm c,l > = 30 mm
all. crack width wk = 0.30 mm wk = 0.30 mm
Pocket Geometry
Pocket Geometry X Y Z
with toothed formwork m m m
outside 1.30 1.50 1.40
inside, top 0.65 0.85 1.40
inside, bottom 0.65 0.85 1.40
The geometry of the hole is still to be examined.
Height of pocket from top edge of foundation: 1.40 m
Pocket Design
LC Direction Stirrup Selected Description F Ed req. As exist. As
kN cm² cm²
2 x Standing stirrup 2*2*0Ø12 + 2*0Ø14 max. V 63.7 1.46 0.00 1
2 y Standing stirrup 2*2*0Ø12 + 2*0Ø14 max. V 476.4 10.96 0.00 1
2 x Ring stirrup top 2*2*0Ø14 Ho 51.4 1.18 0.00
2 y Ring stirrup top 2*2*0Ø14 Ho 454.3 10.45 0.00
2 x Ring stirrup bottom 2*2*0Ø14 Hu 0.0 0.00 0.00
2 y Ring stirrup bottom 2*2*0Ø14 Hu 0.0 0.00 0.00
x,y Standing stirrup total 4*2*0Ø12 + 2*2*0Ø14 + 2*2*0Ø14 24.84 0.00 2
Design in x-direction
Köcherbewehrung:
maßg. innerer Hebelarm
z = 5/6 * t
= 5/6 * 1.40 = 1.17 [m]
Neigung Druckstrebe
tan α = z / (a0 - 0.15*a0) - dw/2
= 1.17 / (1.30 - 0.20) - 0.33/2 = 1.24 [-]
Horizontalkraft oben
ho = (6/5) * (M St/t) + (6/5) * H St
= (6/5) * 60.0/140.0 + (6/5) * 0.0 = 51.4 [kN]
Horizontalkraft unten
hu =
= = 0.0 [kN]
Bewehrung Standbügel
erf. As,v = h0 * tan α / fyd
= 63.7 / 434.783 = 1.5 [cm²]
Design in y-direction
Köcherbewehrung:
Neigung Druckstrebe
tan α = z / (a0 - 0.15*a0) - dw/2
= 1.17 / (1.50 - 0.23) - 0.33/2 = 1.05 [-]
Horizontalkraft oben
ho = (6/5) * (M St/t) + (6/5) * H St
= (6/5) * 530.0/140.0 + (6/5) * 0.0 = 454.3 [kN]
Horizontalkraft unten
hu =
= = 0.0 [kN]
Determining the overlapping joint of the longitudinal reinforcement in the column with vertical pocket reinforcement, due to
the existing cross pressure there is assumed an composite stress increased by 50%. See sheet 600 10.9.6.2 (4).Liegend
gefertigte Stahlbetonstützen sind mit einem Außenrüttler zu verdichten, damit der gute Verbundbereich gerechtfertigt ist.
Demo Frilo Projekt: My Project
Stuttgarter Straße 40 Phone: 0711 810020 Position: FD+-001
70469 Stuttgart Fax: 0711 858020 07.12.2020 Seite: 13
Anchorage in x-direction
Verankerungslänge Stützenzugbewehrung
l bd,tension = l b,rqd*(A s,erf/A s,vorh)
= 87.3*(37.69/128.68) = 0.26 [m]
Verankerungslänge Stützendruckbewehrun
l bd,pressure = l b,rqd*(A s,erf/A s,vorh)
= 87.3*(37.69/128.68) = 0.26 [m]
Verankerungslänge vorh.
l bd,vorh = t-c nom,col
= 1.40-0.03 = 1.37 [m]
lichter Stababstand
a n = a - (Ø 1 + Ø 2) / 2
= 28.8 - (1.2 + 3.2) / 2 = 0.27 [m]
Übergreifungslänge
l 0,z1,min = l 0,z1 + (a n - min(4Ø 1,5))
= 24.9 + (26.6 - min(4*1.2,5)) = 0.47 [m]
Übergreifungslänge
l 0z,2,min = l 0,z2 + (a n - min(4Ø 2,5))
= 52.4 + (26.6 - min(4*3.2,5)) = 0.74 [m]
Übergreifungslänge vorh.
l bd,vorh = t-(c nom,col+c nom,Köcher)
= 1.40-0.03-0.02 = 1.35 [m]
Druckstrebenwinkel
tan θ = l 0,z,vorh. - 0,5 * (l 0,z1 + l 0,z2) / a
= 135.0 - 0,5 * (24.9 + 52.4) /28.8 = 3.35 [-]
erforderliche Verankerungslänge
l b,z = l b,rqd*(A s,erf/A s,vorh)
= 38.2*(1.46/0.00) = 0.38 [m]
vorhandene Verankerungslänge
l b,zvorh = h-c v,k
= 50.00-10.00 = 0.40 [m]
Demo Frilo Projekt: My Project
Stuttgarter Straße 40 Phone: 0711 810020 Position: FD+-001
70469 Stuttgart Fax: 0711 858020 07.12.2020 Seite: 14
horizontale Köcherbügel
l 0,Bügel = l b,rqd
= 54.5 = 0.55 [m]
horizontale Köcherbügel
l0,Bügel,vorh =
= = 0.25 [m]
Demo Frilo Projekt: My Project
Stuttgarter Straße 40 Phone: 0711 810020 Position: FD+-001
70469 Stuttgart Fax: 0711 858020 07.12.2020 Seite: 15
Anchorage in y-direction
Verankerungslänge Stützenzugbewehrung
l bd,tension = l b,rqd*(A s,erf/A s,vorh)
= 87.3*(37.69/128.68) = 0.26 [m]
Verankerungslänge Stützendruckbewehrun
l bd,pressure = l b,rqd*(A s,erf/A s,vorh)
= 87.3*(37.69/128.68) = 0.26 [m]
Verankerungslänge vorh.
l bd,vorh = t-c nom,col
= 1.40-0.03 = 1.37 [m]
lichter Stababstand
a n = a - (Ø 1 + Ø 2) / 2
= 28.8 - (1.2 + 3.2) / 2 = 0.27 [m]
Übergreifungslänge
l 0,z1,min = l 0,z1 + (a n - min(4Ø 1,5))
= 24.9 + (26.6 - min(4*1.2,5)) = 0.47 [m]
Übergreifungslänge
l 0z,2,min = l 0,z2 + (a n - min(4Ø 2,5))
= 52.4 + (26.6 - min(4*3.2,5)) = 0.74 [m]
Übergreifungslänge vorh.
l bd,vorh = t-(c nom,col+c nom,Köcher)
= 1.40-0.03-0.02 = 1.35 [m]
Druckstrebenwinkel
tan θ = l 0,z,vorh. - 0,5 * (l 0,z1 + l 0,z2) / a
= 135.0 - 0,5 * (24.9 + 52.4) /28.8 = 3.35 [-]
erforderliche Verankerungslänge
l b,z = l b,rqd*(A s,erf/A s,vorh)
= 38.2*(10.96/0.00) = 0.38 [m]
vorhandene Verankerungslänge
l b,zvorh = h-c v,k
= 50.00-10.00 = 0.40 [m]
Demo Frilo Projekt: My Project
Stuttgarter Straße 40 Phone: 0711 810020 Position: FD+-001
70469 Stuttgart Fax: 0711 858020 07.12.2020 Seite: 16
horizontale Köcherbügel
l 0,Bügel = l b,rqd
= 54.5 = 0.55 [m]
horizontale Köcherbügel
l0,Bügel,vorh =
= = 0.25 [m]
Pocket
Laying measure the sides and top cV,s,o = 2.0 cm
Laying measure bottom cV,u = 10.0 cm
Sel. anchoring depth 1) t = 1.40 m Column
1) The pocket depth results from embedment depth plus joint width
Bewehrungsgrafik
Demo Frilo Projekt: My Project
Stuttgarter Straße 40 Phone: 0711 810020 Position: FD+-001
70469 Stuttgart Fax: 0711 858020 07.12.2020 Seite: 17
Bewehrungsgrafik
Demo Frilo Projekt: My Project
Stuttgarter Straße 40 Phone: 0711 810020 Position: FD+-001
70469 Stuttgart Fax: 0711 858020 07.12.2020 Seite: 18
Bewehrungsgrafik
Demo Frilo Projekt: My Project
Stuttgarter Straße 40 Phone: 0711 810020 Position: FD+-001
70469 Stuttgart Fax: 0711 858020 07.12.2020 Seite: 19
Bewehrungsgrafik