Support Arrangement Natural Frequency

This document evaluates flow induced turbulence in the discharge line of the RIMA DWD pump P-13101. It determines that the pipe has a flexible stiffness based on its natural frequency. It then calculates several factors related to flow induced vibration and turbulence, including: the flow induced vibration factor (Fv) of 5607.37, the fluid viscosity factor (FVF) of 1.0, and the likelihood of failure (LOF) of 1.26. Based on the LOF, it recommends assessing small bore connections and performing a visual survey to check for construction, geometry, support issues or potential vibration transmission from other sources.

Uploaded by

rajeevfa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
337 views3 pages

Support Arrangement Natural Frequency

This document evaluates flow induced turbulence in the discharge line of the RIMA DWD pump P-13101. It determines that the pipe has a flexible stiffness based on its natural frequency. It then calculates several factors related to flow induced vibration and turbulence, including: the flow induced vibration factor (Fv) of 5607.37, the fluid viscosity factor (FVF) of 1.0, and the likelihood of failure (LOF) of 1.26. Based on the LOF, it recommends assessing small bore connections and performing a visual survey to check for construction, geometry, support issues or potential vibration transmission from other sources.

Uploaded by

rajeevfa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

SCREENING FOR FLOW INDUCED TURBULENCE

System: RIMA DWD PUMP P-13101 DISCARGE LINE

Line No: 16"-W13452-15832

Below evaluation follows the "EI Guideleines for the Avoidance of Vibration Induced Fatigue Failure in Process Pipework", 2nd edition

Input

Outside dia. Of pipe D 406.4 mm

wall thickness of pipe T 26.19 mm

Density of fluid ρ 1000 kg/m3

Velocity of fluid v 2.65 m/s

Natural frequency fn 3 Hz (From CAESAR II CALCULATION)

Gas dynamic Viscosity µ - Pa.S (Applicable for only gas system)

Fluid type Liquid (Gas/Liquid/Multiphase)

According to table T2-1, Guideline for Support arrangement given with repsect to Natural frequncy of system as below:

Support Arrangement Natural Frequency

Stiff 14 to 16 Hz
Medium Stiff 7Hz
Medium 4Hz
Flexible 1Hz

Flow Induced Vibration Factor (Fv): (Reference Section T.2.2.3.4, Table T2-2)

Stiffness:= Flexible

According to table, A-4:

α = 770271.74 if stiffness = stiff

434289 if stiffness = Medium stiff

235349.6 if stiffness = Medium (273 <=D<=762)

NA if stiffness = Medium (60 <=D<=219)

66144.75 if stiffness = Flexible (273 <=D<=762)

NA if stiffness = Flexible (60 <=D<=219)


SCREENING FOR FLOW INDUCED TURBULENCE

System: RIMA DWD PUMP P-13101 DISCARGE LINE

Line No: 16"-W13452-15832

α = 66144.75
SCREENING FOR FLOW INDUCED TURBULENCE

System: RIMA DWD PUMP P-13101 DISCARGE LINE

Line No: 16"-W13452-15832

β = -0.78 if stiffness = stiff

-0.84 if stiffness = Medium stiff

-0.84 if stiffness = Medium (273 <=D<=762)

NA if stiffness = Medium (60 <=D<=219)

-0.9 if stiffness = Flexible (273 <=D<=762)

NA if stiffness = Flexible (60 <=D<=219)

β = -0.9

Fv NA if stiffness = stiff

NA if stiffness = Medium stiff

NA if stiffness = Medium (273 <=D<=762)

NA if stiffness = Medium (60 <=D<=219)

5607.37 if stiffness = Flexible (273 <=D<=762)

NA if stiffness = Flexible (60 <=D<=219)

Flow induced vibration number, Fv:

Fv = 5607.37

Fluid Viscosity Factor (FVF): (Reference Section T.2.2.3.2)

FVF 1 (FVF is 1.0 for Liquid and Multiphase Fluids)

Flow Induced Turbulance LOF: (Reference Section T.2.2.3.5)

The likelihood of failure, LOF:

LOF = 1.26

Recommendations: (As per Table 3-1)

As per Table 3-1, for LOF= 1.26

Small Bore Connection on Main line should be assesed as per Section T3.

A Visual survey shuold be undertaken to check poor construction and/or Gerometry and/or support for main line and/or potential vibration
transmission from other sources. (As per Section T-5)