Furnace Design and Operation
Furnace Design and Operation
operation
Since the target surface area increases with the distance of the sensor
from the target At/Z2 reduces to a constant and because the temperature
of the sensor is known, the temperature of the surface can be calculated
from qradiation received by the sensor, provided the emissivity is also
known
In some cases two sensors, each responding to a single waveband, are
used to produce a two-colour instrument. The latter reduces the error
Ultra-sonic measurement
Ultrasonic temperature
measurement depends on
the relationship between
the speed of sound and
the density of the medium
it passes through
The speed of sound is measured by
determining the time taken for the
sound wave to cross the duct
For gases density is related to temperature and providing the gas
composition is known the temperature can then be calculated from
the ideal gas laws
Pressure/flow instruments
Electro- In-situ or 0 – 25% 0 – 100000 NO 0 –5000 ppm 0-5000 ppm 0 55 ppm methane
chemical remote ppm X X NO2 0 – 1000 ppm
cell
Para- Remote 0 – 21%
magnetic X X X X X X
meter
Chemical Remote 0 – 21% in
adsorption ranges v v X v v v
(Drager)
Wet Remote 0 – 21%
chemical v v X X X X
(Orsat)
Wet Remote
chemical X X v X X X X
(Dwyer)
Sampling systems
Draw a sample of gas from the flue gas system These are mounted near to the stack and have
via a small tube. The sample is normally filtered, the sensor either in the stack or are close by
dried and cooled prior to analysis. Because water coupled to a short probe. The gas is sampled hot
vapour is removed, the reading is related to the and conditioning is either not required or limited
dry gas components only to filtration for particlulate removal
Advantages Disadvantages Advantages Disadvantages
The analysers can be Sampling systems are Non-sampling systems For most gases in-situ
located in a clean costly to install and are easier to install and analysers are less
environment maintain maintaim accurate then remote
units
The analyser has a Sampling system design Skills required to install Apart for oxygen, only
clean sample is a specialist skill not the systems are gases that absorb infra-
normally available on normally available on a red radiation can be
plant typical plant analysed in-situ
Greater accuracy can The instrument supplier Maintenance is normally The wet gas analysis
often be achived with may not have sufficient reduced owing to makes calculation of
remote mounted process knowledge to absence of a complex true excess air levels
analysers design an appropriate sampling system more difficult
sample system
The same sample can Even small leaks in the Errors caused by leaks The analyser is more
be analysed by a sampling system can in the sampling system vulnerable to damage
number of different create large errors in are absent owing to its location
analysers for a wide the readings, especially
range of gas for oxygen
compositions
Extractive sampling
Extractive sampling
probes
Obscuration back-scattering