The document provides calculations for the annual energy output of a photovoltaic (PV) system based on location, panel specifications, mounting, and other factors. The summary is: The PV system is located in Central time zone at latitude 29.95 degrees south and longitude -95.35 degrees west. It calculates the annual energy output in kBTU/sqft for a SunPower SPR-E20-435 panel mounted at various tilt angles from 0-40 degrees and azimuth angles from -25 to 15 degrees. The peak annual energy output is 67.02 kBTU/sqft at a tilt of 25 degrees and azimuth of 0 degrees.

Uploaded by

Ndia2007
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views2 pages

PV System Design Tool

The document provides calculations for the annual energy output of a photovoltaic (PV) system based on location, panel specifications, mounting, and other factors. The summary is: The PV system is located in Central time zone at latitude 29.95 degrees south and longitude -95.35 degrees west. It calculates the annual energy output in kBTU/sqft for a SunPower SPR-E20-435 panel mounted at various tilt angles from 0-40 degrees and azimuth angles from -25 to 15 degrees. The peak annual energy output is 67.02 kBTU/sqft at a tilt of 25 degrees and azimuth of 0 degrees.

Uploaded by

Ndia2007
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PV Systems - Annual Energy Output Calculations

Input Module
Location Fixed Tilt Open Rack Mounting
Longitude -95.35 Degree (-value west of Greenwich) Orientation Landscape
Latitude 29.95 Degree (-value south of equator) Row Spacing 24.0 inch
Standard Time Zone Central
Apply Daylight Saving Yes
Elevation 0.0 Ft Optical Losses
Soiling Loss 2.0 % (5% Long dry seasons)
(2% Year-round rain)
PV Panel
PV Panel Model SunPower SPR-E20-435-COM DC Power Losses
Length 82.0 inch (longer dimension) Mismatch (Binning) Losses 2.0 % (2% default)
Width 42.0 inch (shorter dimension) Wiring Losses 1.0 % (1% default)
Efficiency 20.1 %
Power Temperature Coefficient -0.350 %/⁰C
Bypass Diodes - Landscape 6 AC Power Losses
Bypass Diodes - Portrait 3 Invertor Efficiency 98.5 % (98% default)

PV Panel Orientation And Mounting Design Safety Factor


Minimum Tilt Angle 0.0 Degree Safety Factor 0.0 %
Maximum Tilt Angle 40.0 Degree
Minimum Azimuth Angle -25.0 Degree (clockwise from south)
Maximum Azimuth Angle 15.0 Degree (clockwise from south) Output Units
Mounting Type Fixed Tilt Open Rack Units of Energy Output EUI (kBTU/Sq.Ft./yr)

Output Module

Annual Energy Output (EUI - kBTU/Sq. Ft./yr)


(Based on Total Land Area of PV System)
Tilt Angle PV Panel Azimuth Angle (Degree)
15.0 10.0 5.0 0.0 -5.0 -10.0 -15.0 -20.0 -25.0
0.0 59.7 59.7 59.7 59.7 59.7 59.7 59.7 59.7 59.7
5.0 61.2 61.4 61.6 61.7 61.9 62.0 62.1 62.2 62.3
10.0 62.6 63.0 63.3 63.5 63.8 64.0 64.1 64.3 64.3
15.0 63.6 64.1 64.6 65.0 65.3 65.5 65.7 65.8 65.8
20.0 64.1 64.8 65.5 66.0 66.3 66.5 66.7 66.7 66.6
25.0 63.8 64.7 65.4 66.0 66.4 66.8 67.0 67.0 66.9
30.0 62.7 63.4 64.3 65.0 65.5 65.8 66.2 66.5 66.4
35.0 61.7 62.5 63.3 64.1 64.7 65.1 65.3 65.4 65.5
40.0 60.5 61.3 61.9 62.6 63.3 64.0 64.2 64.5 64.4

Performance At Peak Annual Energy Output :


Peak Annual Energy Output 67.02 (EUI - kBTU/Sq. Ft./yr)
Shading Lossed 4.0 %
Reflection Losses 2.1 %
Temperature Deration 5.3 %
Low Radiance Losses 1.2 %
Invertor Losses 1.7 %
Ground Coverage Ratio 67.7 % (Area of PV Panels Divided By Total Land Area)