ISM-INTeGRATeD

SMART MODULe TM
MORe THAN JUST MONITORING.
INDIVIDUAL SOLUTIONS.
TR A N S F O R MeR C ONTROL
ISM-Integrated Smart Module TM

ISM-Integrated Smart Growing grid interconnections plus the greater need for availability and reliability of
network resources make continuous status monitoring and evaluation indispensible.
Our ISM-Integrated Smart ModuleTM and the superordinated visualization and
Module TM – INTELLIGENCE evaluation possibilities offer you a particularly inexpensive, practice-oriented method
for making both asset and operational management easier.
EX WORKS.
OR FOR UPGRADES. included ex factory. Naturally, the ISM can also be in-
stalled into a separate control cabinet. Our complete
offer also includes the construction and engineering
of the control cabinet. In either case, you can trans-
Record, collect, evaluate, control, fer the recorded data directly to the control room via
and visualize transformer data: optical fiber.
No matter what you want to do,
ISM makes it possible. This means much less wiring work during installation
and considerably lower costs compared to a conven-
The ISM-Integrated Smart Module™ can record and tional connection. In addition to an integrated web
evaluate practically all operational data of power server that makes the time-consuming installation of
transformers including, for example, monitoring the software packages unnecessary, we also offer you a
tap changer or analyzing transformer utilization. The wide selection of standard control system protocols.
ISM enables goal-oriented planning of the operation,
utilization, maintenance and exchange of your
equipment.

ISM offers you a particularly inexpensive monitoring


system which also makes sense as an upgrade for
older and smaller transformers, thereby ensuring their
fitness for future demands. Network Conventional connection –
control room
enormous amount of wiring
This builds the basis for a comprehensive monitoring work and high costs
system for your transformers.
Marshalling
box
I Mounting of the sensors in the
Our superordinated visualization and analysis solu- marshalling box
tions make the monitoring of your transformer fleet I Connection of the marshalling box
and the related access to the local ISMs child’s play. to the control room: one-on-one

Implementation of your individual requirements in a


practice-oriented system takes priority. Our services
are not just limited to the delivery of a device. We
also advise you and, together with you, develop the
optimum solution that is tailored to your needs (incl.
commissioning). Network New low-cost direct connection
control room

Minimum wiring, I Connection of the sensors to the


maximum flexibility ISM-Integrated Smart Module™
ISM I Conversion of the electrical signals
Starting immediately, you can order our dependable I Transmission of the data directly to
TAPMOTION® ED motor drives with additional intel- the control system with standard
ligence. The result: the intelligent TAPMOTION® ED communication protocols
with the ISM-Integrated Smart Module™ already I Optional: EMC-secure connection
via fiber optic conductors

2 3
ISM-Integrated SMart Module tM

For all tHoSe WHo lIKe to


Simple, inexpensive retrofitting:
Bild 1 Task: Upgrading the monitoring
system in an existing TAPMOTION® ED
Bild 2 Implementation: Installation

ConCentrate on tHe eSSentIalS. of the ISM by our experts in just a


few hours.
Bild 3 Result: Fit for the future – thanks
to intelligence in the existing motor
drive.

on-load tap-changer monitoring Individual solutions Fit for future requirements For those who would like a little
more: the tailor-made system
I Monitoring of oltC and motor drive I Customer-specific algorithms for data recording, the ISM-Integrated Smart Module tM is also
I Maintenance diagnostics regulation and control available as a retrofit module for all taPMotIon® If desired, our experts will develop solutions
I design based on customer needs ed motor drives that have been delivered to that are precisely adapted to your require-
transformer monitoring I Freely configurable inputs and outputs date. upgrade your taPMotIon® motor drive in ments. In the areas of power supply, trans-
I reduction of functional range is possible just a few hours with additional intelligence to mission and distribution we offer tailor-
I load voltage, load current meet your own individual requirements. made systems for the following areas: data
I active power, reactive power and apparent Control system communication management, control system connection,
power user-friendly visualization regulation and control, automation of
I temperatures (environment, topoil, hotspot) I IeC 61850 and evaluation equipment and monitoring of power supply
I aging rate and overload capacity of the I IeC 60870-5-101 components. take advantage of our decades
transformer I IeC 60870-5-104 the ISM-Integrated Smart Module tM accesses of experience in the control and monitoring
I Status information on the transformer I Modbus tCP your system via internet browser without any on-load tap-changers.
protection systems I Further protocols available on request extra software. Whether from the control room
I dissolved gas analysis (dga) or from external locations,thanks to the flexible our all-round service offers:
I oil level implementation in standard internet browsers I evaluation of the situation
I expanded monitoring you can call up the measured values of the ISM I Consulting
no matter where you are even while observing I development of a solution
your security requirements. the presentation I engineering
occurs in a well-organized manner without I development and implementation
network time-consuming software installation. I Commissioning
SCada control
center
I Customer support

55 MVA

Home
Visualization
(Panel PC/laptop) taPMotIon® ed ISM-Integrated SMart ModuletM ISM-Integrated SMart ModuletM
ISM-Integrated SMart ModuletM Stand-alone retroFIt
ISM
28.4 °C
I Communication I Communication I Communication 500 A 500 A 500 A
I Control I Control I Control 110 kV 110 kV 110 kV
I data accumulation I data accumulation I data accumulation
I data capturing I data capturing I data capturing Monitoring of individual transformers
Events

17
60.4 °C 62.3 °C

Connection of: Information


dga, Buchholz, oil level, tap position,
oil temperature, environmental 79.6 °C

ISM temperature, pressure relief valve,


voltage/current/performance
EN LOGIN REBOOT ADMIN 2013.07.08 10:21 Settings

4 5
ISM-Integrated Smart Module TM

Cross-regional Monitoring
of all Transformers.
Fleet management made easy: our ISM-Integrated Both within stations as well as superordinated to Important information such as oil condition or the Disruption elimination can therefore either occur very
Smart ModuleTM creates the basis for a comprehen- multiple substations our fleet monitoring provides a utilization of the individual transformers is illustrated quickly or be made unnecessary. Even subtle changes
sive monitoring system for your transformers. We clear presentation of the information regarding indi- centrally. If a critical event occurs, an email or can be identified simply and dependably via the trend
offer suitable visualization solutions which make vidual transformers thereby simplifying the condition text message is sent and, naturally, depicted in the illustration. Another basic component is the decen-
the monitoring of your fleet child’s play. analysis of the various assets. visualization. tralized or centralized storage of all recorded and
analyzed data for the purposes of trend assessment
and archiving.

Communication
Visualization
Data storage

Fleet Monitoring
Visualization
Data storage
Data interpretation

Clearly arranged
S/S 16/2
Communication City illustration of the
Communication transformer
Visualization S/S 17/4
Visualization
Data storage S/S 10/1
Data storage Recording of trends
Data recording
and events
S/S 15/3
S/S 10/2
Forwarding of
Village warnings via
SMS and email

Communication
Visualization Communication
Data storage Visualization
Data recording Data storage

Communication
Visualization
Data storage
Data recording

6
ISM-Integrated SMart Module tM

MonItorIng -
all tHat’S neCeSSarY.
the ideal solution for all operators.

low life-cycle costs


I the recording, storage and evaluation of all necessary values related to the
transformer enable maintenance based on current conditions
I direct transmission of the information to the control system reduces conventional
wiring needs
I our solution for smart asset management

Simple integration
easy to integrate into higher-level operation management since all conventional
control system protocols are supported

Flexible customizing
I Platform-independent visualization of the data via popular internet browsers
I Periodic, automatic archiving on Sd card or ftp server of all measured data recorded during
the past few years. the ftp server can also be accessed directly via the visualization
I Fast and flexible functional customization by our experts to meet your particular needs

Visualization
I Higher-level visualization of multiple transformers
(within a single substation or across multiple substations)
I trend recording and archiving of all information relevant to determining the current
transformer condition
I Superior alarm handling
Maschinenfabrik Reinhausen GmbH
Falkensteinstrasse 8
93059 regensburg, germany

Phone: +49 941 4090-0


Fax: +49 941 4090-7001
email: [email protected]

www.reinhausen.com

Please note:
the data in our publications may differ from
the data of the devices delivered. We reserve
the right to make changes without notice.

In3399192/01 en – ISM-Integrated Smart ModuletM–


F0304701 – 09/13 – uw –
©Maschinenfabrik reinhausen gmbH 2013

You might also like