Solid and Liquid Waste Management

Download as pdf or txt
Download as pdf or txt
You are on page 1of 68

Technological Options for

Solid and Liquid Waste


Management in Rural Areas

MINISTRY OF DRINKING WATER AND SANITATION


SWACHH BHARAT MISSION (GRAMIN)
GOVERNMENT OF INDIA
April 2015
Technological Options
for
Solid and Liquid Waste Management in Rural Areas

Ministry of Drinking Water and Sanitation


Swachh Bharat Mission (Gramin)
Govt. of India

April 2015
iii
v
Technological Options for
Solid and Liquid Waste Management in Rural Areas

Contents
Page
0. Executive Summary ................................................................................................................. iii
1. Chapter - 1: Introduction ........................................................................................................ 1
1.1. Introduction ....................................................................................................................... 1
1.2 Solid and Liquid Waste Management under SBM (G) ..................................................... 2

2. Chapter – 2: Technological Options for Liquid Waste Management .................................. 4


2.1 Criteria for selection of Technology ............................................................................... 4
2.2 generation and characterisation .................................................................................... 4
2.3 Wastewater collection and treatment systems in rural areas in India ....................... 5
2.4 Wastewater collection systems ........................................................................................ 8
2.4.1 Covered surface drains ......................................................................................... 8
2.4.2 Small bore sewers ............................................................................................... 9
2.4.3 Conventional / simplified sewer ......................................................................... 11
2.5 On-site Waste water treatment systems ....................................................................... 11
2.5.1 Septic tanks ......................................................................................................... 11
2.5.2 Bio-tank System ................................................................................................. 13
2.5.3 Advanced on-site systems .................................................................................. 14
2.5.3.1 Package type anaerobic filter system .................................................................. 15
2.5.3.2 Package contact aeration system ........................................................................ 16
2.5.3.3 Package anaerobic filter contact aeration system ............................................... 16
2.5.4 On site waste water disposal system (soakage pit) ............................................ 17
2.6 Decentralised Waste water treatment systems ............................................................ 18
2.6.1 Site selection criteria .......................................................................................... 21
2.6.2 Waste Stabilisation Ponds Technology ............................................................... 21
2.6.3 Duckweed pond system ...................................................................................... 23
2.6.4 Constructed Wetland .......................................................................................... 26
2.6.5 Phytorid Technology for Sewage Treatment ...................................................... 28
2.6.6 Soil Bio Technology (SBT) for Sewage Treatment ............................................ 30
2.6.7 Anaerobic Baffled Reactor (ABR) ..................................................................... 31

vii
Solid and Liquid Waste Management in Rural Areas

2.6.8 Up flow Anaerobic Sludge Blanket (UASB) Reactor ........................................ 32


2.6.7 Settling Contact Aeration System ...................................................................... 33
2.6.8 Extended Aeration ............................................................................................. 35
2.6.9 Sequencing Batch Reactor (SBR) Process ........................................................ 36
2.7 Septage and sludge Management ................................................................................ 37
2.7.1 Desludging of septic tanks and advanced on-site systems ................................. 37
2.7.2 Treatment of Septage ......................................................................................... 37
2.8 Karnal Technology ........................................................................................................ 38
2.9 Workers safety issues .................................................................................................... 39
2.9.1 Personal Hygiene against pathogens .................................................................. 39
2.9.2 Health check ...................................................................................................... 39

3. Chapter- 3: Technological Options for Solid Waste Management


3.1 Solid Waste Management in rural areas ..................................................................... 40
3.2 Technological options for composting of Organic wastes ......................................... 41
3.2.1 NADEP Composting .......................................................................................... 41
3.2.2 Bangalore Method of Composting .....................................................................43
3.2.3 Indore Method of Composting ........................................................................... 43
3.2.4 Vermi Composting .............................................................................................. 44
3.2.5 Rotary Drum Composting .................................................................................. 46
3.2.6 Biogas Technology ............................................................................................. 47

References ..................................................................................................................................... 54

viii
CHAPTER- 1
INTRODUCTION

1.1 INTRODUCTION as fodder, cattle dung for fuel and compost and ash
as manure in rice fields etc., such that there is no
Proper management of solid and liquid wastes is waste generated beyond the assimilative capacity
an important determinant of improved sanitation of the environment. However, due to increasing
in any community. The goals of sanitation population, growing consumerism, changing food
fail miserably when solid and liquid waste habit, increasing use of plastics, packaging and
management aspect is not given proper attention use and throw items etc, the management of waste
to improve health and living environment of the is emerging as an issue needing urgent attention
community. In rural areas, this aspect is mostly from the point of view of health and environment
neglected due to lack of proper infrastructure, even in rural settings.
unavailability of sustainable technology at
household or community level and moreover lack There are also increasing concerns on liquid waste,
of adequate O&M infrastructure and awareness of especially the grey water generated in households,
common people. In most of the rural areas it is not institutions and common places and wash water
a felt-need problem. from kitchen, bathroom, markets etc. The stagnant
water provides conducive domain for breeding
Management of solid or liquid wastes in rural areas for disease vectors. The absence of storm water
is much easier than in urban areas due to the fact drains or dilapidated streamlets etc. enhances
that there are no highly contaminated industrial the water logging scenario, creating unhygienic
wastes. In rural areas, most of the wastes can be and anaesthetic conditions. The liquid waste also
safely reused for beneficial purposes with limited poses serious problems by contaminating surface
resources. Further, in rural areas there are usually water as well as ground water, the later especially
less space constraints allowing for the application in high water table regimes. There are several
of natural wastewater treatment systems therefore technologies suitable for different socio-economic
increasing to choice of options. and geological conditions of rural areas. Some of
the natural wastewater treatment technologies
A number of waste prevention techniques for solid evaluated by Starkl et al. (2013), also been
and liquid waste management are available, and included in this handbook. This handbook aims
they are commonly summarized as the so-called to provide complete information on sustainable
4Rs: Reduction, Reuse, Recycling and Recovery. technologies for wastewater as well as solid
In India with its great diversity of climate, terrain, wastes for rural areas. Selection of technology by
resource availability, livelihood, culture and community should be based on the availability of
habit, the quantity and quality of waste generated space requirement, onetime cost and operation
vary significantly. In general, typical indigenous and maintenance costs of the system. Their needs
systems prevail in different regions, whereby a active involvement of community right from
chain of material use exists based on zero disposal planning, designing, execution and operation and
and discharge. There are specific uses attributed to maintenance of the systems for solid and liquid
each part of the farm products. For example, rice waste management.
is used for cooking, rice husk for fuel, rice straw

1
Solid and Liquid Waste Management in Rural Areas

1.2 SOLID AND LIQUID WASTE managed sanitation systems focusing on


MANAGEMENT UNDER THE SBM scientific Solid & Liquid Waste Management
(G) GUIDELINES systems for overall cleanliness in the rural
areas.
To accelerate the efforts to achieve universal
sanitation coverage and to put focus on sanitation, The objective of SBM (G) is to bring about
the Prime Minister of India launched the Swachh improvement in the cleanliness, hygiene and
Bharat Mission on 2nd October, 2014. The the general quality of life in rural areas. Solid
Mission Coordinator shall be Secretary, Ministry and Liquid Waste Management (SLWM) is one
of Drinking Water and Sanitation (MDWS) with of the key components of the programme. To
two Sub-Missions, the Swachh Bharat Mission create clean villages, it is essential that the IEC
(Gramin) and the Swachh Bharat Mission interventions focus on Solid and Liquid Waste
(Urban), which aims to achieve Swachh Bharat Management so as to create a felt need for these
by 2019, as a fitting tribute to the 150th Birth activities amongst the population. This must lead
Anniversary of Mahatma Gandhi, which in to the setting up of systems for the scientific
rural areas shall mean improving the levels of disposal of waste in such a way that has a tangible
cleanliness in rural areas through Solid and Liquid impact on the population. The Community / Gram
Waste Management activities and making Gram Panchayat have to be motivated to come forward
Panchayats Open Defecation Free (ODF), clean and demand for such a system, which they have to
and sanitised. The Mission shall strive for this by subsequently operate and maintain.
removing the bottlenecks that were hindering the
progress, including partial funding for Individual Once the demand is created, to ensure that the
Household Latrines from MNREGS, and focusing resources are used efficiently, SLWM is to be
on critical issues affecting outcomes. taken up in project mode for each Gram Panchayat
(GP) with financial assistance capped for a GP on
The main objectives of the SBM (G) are as under: number of household basis to enable all GPs to
a) Bring about an improvement in the general implement sustainable SLWM projects. The total
quality of life in the rural areas, by promoting assistance under SBM (G) for SLWM projects
cleanliness, hygiene and eliminating open shall be worked out on the basis of total number of
defecation. households in each GP, subject to a maximum of
Rs.7 lakh for a GP having up to 150 households,
b) Accelerate sanitation coverage in rural areas Rs.12 lakh up to 300 households, Rs.15 lakh up
to achieve the vision of Swachh Bharat by to 500 households and Rs.20 lakh for GPs having
2nd October 2019. more than 500 households. Funding for SLWM
c) Motivate Communities and Panchayati Raj project under SBM (G) is provided by the Central
Institutions to adopt sustainable sanitation and State Government in the ratio of 75:25. Any
practices and facilities through awareness additional cost requirement is to be met with
creation and health education. funds from the State / GP, and from other sources
like Finance Commission funding, CSR, Swachh
d) Encourage cost effective and appropriate
Bharat Khosh and through the PPP model.
technologies for ecologically safe and
sustainable Sanitation.
Under Solid and Liquid Waste Management, the
e) Develop where required, Community following activities inter-alia may be undertaken:

2
i. For Solid Waste Management: States ii. For Liquid Waste Management: States are
are to decide the technologies suitable to identify suitable technologies. Methods
to their areas. Technologies identified adopted for
by the Committee on Technologies may
also be considered for implementation. Management of liquid wastes may focus on
Collection, segregation and safe disposal maximum reuse of such waste for agriculture
of household garbage, decentralized purposes with least operation and maintenance
systems like household composting and costs. For collection of waste water, low cost
biogas plants shall be permitted. Activities drainage/ small bore system, soakage pit may be
related to maximum reuse of organic solid adopted.
wastes as manure should be adopted.
Such technologies may include vermi- For details of the technologies suitable for rural
composting, NADEP composting, or any areas, this handbook and other publications
other composting method, individual and under preparation to be issued by the Ministry of
community biogas plants. Funds allocated Drinking Water and Sanitation may be referred.
for Solid and Liquid Waste Management
may be used to implement safe disposal All GPs are to be targeted for coverage with a
solutions for menstrual waste (used sanitary SLWM project. SLWM Projects for each GP
cloths and pads) and setting up incinerators should be part of the annual District Plan. The
in Schools, Women’s Community Sanitary Annual District Plan should be approved by
Complexes, Primary Health Centre, or State level Scheme Sanctioning Committee
in any other suitable place in village and (SLSSC). Each individual SLWM project may be
collection mechanisms etc., can be taken approved at the DWSC level as per the technical
up. Technologies may include appropriate and financial rules of the individual states. The
options that are socially acceptable and objective is to initiate SLWM projects in all GPs
environmentally safe. without delay.

3
Solid and Liquid Waste Management in Rural Areas

CHAPTER- 2
TECHNOLOGICAL OPTIONS FOR LIQUID WASTE MANAGEMENT

2.1 CRITERIA FOR SELECTION OF All stakeholders should be involved in the


TECHNOLOGY planning and decision making process based on
their interest and experience. Different technical
There is a range of technological options for Waste options should be compared against the above
water and Solid Waste Management. Selection mentioned points and the preferred option
of technology should be made taking in account selected. It should be justified why the preferred
its sustainability in terms of social, economical option is considered the most sustainable in
and environmental aspects. Selected technology the given context and ensured that it meets the
should be socially acceptable, economically minimum required standards.
affordable and environmental friendly. It further
should be suitable for the expected capacity for 2.2 WASTEWATER GENERATION &
operation and maintenance, in both technical CHARACTERIZATION
and financial terms. This aspect is of particular
importance as different types of technologies will The wastewater from various household activities
require varying degree of technical and financial can be classified into;
inputs during the life time of the technology i. Grey water: Wastewater generated from
to keep it in sustainable operation mode. The bathing, kitchen and other household
following points should be considered in selecting activities except toilet.
any technology:
ii. Backwater: Wastewater generated from
yy Health-differences in risk of infection toilets.
between the options
iii. Combined wastewater: It can be either mix
yy Environment - differences in emissions of grey water and effluent of septic tank
into air and water and the use of energy and treating black water or effluent of septic
natural resources. tank treating black and grey water.
yy Economy - annual and recurring costs iv. Sewage: Combined grey and black water
related to the options generated from household in the absence or
yy Socio-cultural aspects - the appropriateness presence of septic tank.
to current or local cultural context,
institutional viability. The characteristics of the above mentioned types
of wastewater are the function of level of water
yy Technical function - robustness against
supply and per capita pollution load. The level
extreme conditions, maintenance
of water supply plays a major role in deciding
requirements, risk of failure, effect of
the concentration of pollutants. Other significant
failure, structural stability.
factors are settlement and decomposition in drains,
yy Capacity: Local capacity for operation& sewers under warm weather conditions, partially
maintenance in technical and financial treated sewage from septic tanks, lifestyle of
terms

4
the population. The best was to ascertain the In the absence of data, the following characteristics
characteristics is to conduct the sampling and (Table 2.1) can be assumed for various kinds of
analyse various water quality parameters of the Wastewaters: These values are obtained based on
outfall or drain. The samples should be analyzed the analysis under the sponsored research project
for the parameters like BOD, COD, TSS, Total by the Ministry of Drinking Water & Sanitation
Coliforms and Faecal Coliforms. to the Department of Civil Engineering, IIT
Roorkee, Uttranchal.

Table 2.1: Typical values for parameter for various kinds of Wastewaters

Parameters Grey Black Septic Tank Septic Tank Mixed Sewage


water water Effluent* Effluent** Wastewater***
BOD (mg/L 100-300 600-1000 300-600 80-160 150-400 250-400
COD (mg/L) 200-500 1000-2000 600-1000 200-400 300-600 500-800
TSS (mg/L) 100-300 800-1200 300-500 200-400 150-350 600-1000
Fecal Coliforms 102-103 106-107 105-106 103-105 104-105 105-107
(MPN/100 ml)
Total Coliforms 102-103 107-108 106-107 104-106 105-106 105-107
(MPN/100 ml)
*(Treating Black water only)
** (Treating Grey water + Black water)
***Septic Tank Effluent & Grey water

Note: These concentrations are analysed on-site, the values could be 20-40 % lower at the STP site due to settling, biodegradation etc.
process in the wastewater collection system depending on the climatic conditions, type and length of the collection system etc.,

2.3 WASTEWATER COLLECTION & wastewater & sewage) collection, treatment and
TREATMENT SYSTEM IN RURAL disposal/reuse as per the end user requirement.
AREAS These options are either on-site solutions, or
decentralised or mixed solutions. Which is most
In India, as per 2011 census, rural areas sanitation suitable should be elaborated in a thorough
coverage is 32.7% that constitutes 14.7 % septic feasibility study that takes into account the above
tank, 8.2% pit toilets with slab, 2.3 % pit toilets mentioned criteria for technology selection.
without slab, 2.2 % piped sewer system, 1.9 %
public toilets, 2.5 % other toilets, 0.3 % toilets The configurations could be any one of the
cleaned by humans, and 0.2% others. following options depending on the standard of
living, water availability, fund constraints, soil and
As per the prevailing rural conditions of the topographical conditions, density of population
country, 8 different options are suggested for safe etc., of the village.
wastewater (Grey water, Black water, combined

5
Solid and Liquid Waste Management in Rural Areas

Option-1: Sanitation System using Soak pits and Twin-Pit Latrines


(Sandy soil and deep groundwater table, piped water supply, sparse population)

Grey water Soakage pit


Household

Black water Twin pit latrines

Option-2: Sanitation System using Soak pits (Sandy soil and deep groundwater
table, piped water supply sparse population)

Soakage pit

Household Combined Black &


Gre y water (Sewa ge ) Septic Tank

Option-3: (Safe on-site sanitation)

Advanced Agricultural
Combined Covered
on-site /Non-
Household Black & surface
systems/ Potable
Grey water drains
Joukasou Reuse
(Sewage)

Option-4: Sanitation System using Soak pits and Covered surface drains (Sandy soil
and deep groundwater table, piped water supply, sparse population)

Covered Agricult
Grey water Small STP ural
surface drains
Household Reuse
Black water
Septic Tank Soakage pit

Option-5: (Sanitation system using covered surface drains)

Covered Agricultural
Grey water surface drains Small STP Reuse
Households

Black water Septic Tank /


Advanced on-site

6
Option-6: (Sanitation system using covered surface drains)

Covered Agricultural
Small
Combined surface drains
STP Reuse
Household Black & Grey
water
(Sewa ge ) Septic Tank/improved
septic tanks

Option-7: (Partly Sewered sanitation using small bore sewer)

Small Agricultural
Combined Small Bore Sewers
STP Reuse
Black & Grey
Household water
(Sewage)
Septic Tank/ interceptor
tanks/

Option-8 (Fully Sewered sanitation)

Combined
Black & Conventional
Household Small Agricultural / Non-
Grey water Sewers/Simplif
STP potable Reuse
(Sewa ge ) ied sewers

Note: It should be noted that the options using a soak pit may not be environmentally friendly depending on the soil type and groundwater
table and should generally be avoided if financial resources allows. Table 2.2 below summarises the 8 options:

Table 2.2: Options for wastewater management in rural areas

Sl. Type Collection Treatment/disposal* Reuse options


No.
1. On-site Not required Soakage pit for grey water. Twin No option for reuse
pit latrine for black water
2 On-site Not required Septic tank + soakage pit No option for reuse
3 On-site - advanced Not required Advanced on-site systems On-site reuse for
agriculture
4 Mixed Covered surface Decentralised STP for grey water, Reuse of treated grey
drains for grey water septic tank+ soakage pit for black water in agriculture
only water
5 Decentralised non Covered surface Septic tank for black water, Reuse of treated combined
sewered drains treatment of grey water + effluent waste water in agriculture
from Septic tank in decentralised
STP

7
Solid and Liquid Waste Management in Rural Areas

6 Decentralised –non Covered surface Septic tank for combined Reuse of treated combined
sewered drains sewage, treatment of effluent in waste water in agriculture
decentralised STP
7 Decentralised - Small bore sewer Treatment of effluent from Reuse of treated combined
sewered septic tank / interceptor tank in waste water in agriculture
decentralised STP
8 Decentralised - Conventional or Decentralised STP for combined Reuse of treated combined
sewered simplified sewer sewage waste water in agriculture.
Non potable reuse options
can be explored.

* It should be noted that septic and other tanks require regular desludging, see chapter (Septage and Sludge treatment)

2.4 WASTEWATER The objective of covered surface / storm water


COLLECTION
SYSTEM drain is to remove waste water/ rain water from the
households/ premises in a controlled and hygienic
Removing wastewater of any form i.e., grey manner in order to minimize public health and
water, combined grey water and septic tank environmental risks, inconvenience to residents
effluent or sewage and storm water is an important and the deterioration of other infrastructure. This
environmental health intervention for reducing requires:
disease. Poorly drained wastewater and storm yy Removal of grey water and/or septic tank
water forms stagnant pools that provide breeding effluent generated from various household
sites for disease vectors. Hence, there should be activities
proper systems for the collection of wastewater.
yy Removal of storm water, that is, water
There are three common types of collection which runs off the land and houses as a
systems of wastewater; result of rainfall.

i. Covered surface drains The recommended section of covered surface


ii. Small bore sewers drain is shown in the figure (Fig 2.1).The
iii. Conventional sewers half rounded central channel for the peak dry
weather wastewater flow, while the outer channel
2.4.1 Covered Surface drains

In rural areas of India, per capita water supply is


very less. It ranges from 40 lpcd to 70 lpcd only.
Consequently, generation of waste water is too
low to make conventional sewer system effective.
One of the cheapest and interim options for
disposal of grey water, grey water + septic tank
effluent is the covered surface drains. Further,
open channels often exist in rural areas and hence
can be upgraded to covered drains with little
Figure 2.1. A Typical Channel section for carrying both
efforts. dry weather wastewater flow and storm water.

8
facilitates storm water discharge. The outer black water, mixed with grey water, small bore /
channel floor should preferably gently down to swallow sewer is the appropriate and sustainable
the central channel. options for collecting waste water in rural areas.
Small bore sewer systems are designed to receive
Since, open drain/channel have a higher friction only the liquid portion of household wastewater
than a pipe. In relatively flat areas, pipe flow for off-site treatment and disposal. Grit, grease
could be better, an alternative option would be and floating materials are separated from the
laying the pipe into the open channel and cover it. waste flow in interceptor tanks similar to septic
The important design considerations are as tanks. Such interceptor tanks are installed after
follows: each household or group of households as per
yy The raising of road surfaces above the the site conditions. Depending upon the size
plinth level of nearby houses should always of interceptor tanks and inflow of waste water,
be avoided. settled solids should be removed periodically
from the interceptor tanks.
yy In the absence of rainfall data, drainage

schemes should normally be designed for
a return period of 1 year or less. Rainfall
intensity in the range of 50-100 mm per
house can be assumed.
yy Both opened and covered drains give rise to
maintenance problem and their total length
should be minimized.
yy Covered drains should not be smaller than
about 500 mm in square cross section

Applicability:
Figure 2.2: A schematic diagram of Small bore sewer
It is an interim and fast solution of wastewater (Source: Website Jhsphopen Courseware, 2013)
collection and can be applied in any village at
reasonable cost. However, to prevent clogging, Small bore sewer systems consist of:
regular cleaning service for the removal of
sludge is necessary. Further, if existing open yy House connection: The house connection
channels (Nallas) are upgraded it has to be taken is made at the inlet to the interceptor tank.
care of providing sufficient slope of the drains yy Interceptor tank: It is designed to detain
for dry weather flow as existing drains often the liquid flow for 12 to 24 hours and to
lead to stagnant dry weather flow which causes remove both floating and settleable solids
unhygienic conditions and may infiltrate in the from the liquid stream. Volume is also
ground. provided for storage of the solids, which
are periodically removed through an access
2.4.2 Small Bore Sewers port. The design of interceptor tank is
similar to conventional septic tanks
For grey water, surface drain is the cheapest
option for collecting such waste water. For yy Sewer: Sewers are small bore pipe

9
Solid and Liquid Waste Management in Rural Areas

(minimum diameter of 100 mm) which because the interceptor tanks provide some
are trenched into the ground at a depth surge storage. Expensive manholes are not
sufficient to collect the settled wastewater required in case of small bore system.
from most connections by gravity. Unlike
(d) Reduced treatment requirements.
conventional sewers, small bore sewers are
Interceptor tanks arrest floating materials,
not necessarily laid on a uniform gradient
oil and grease and most of the settleable
with straight alignment between manholes
solids from wastewater. Therefore, it
or cleanouts.
reduces cost of the treatment, as it requires
yy Cleanout Manhole: Cleanouts and lesser hydraulic retention time for treatment
manholes provide access to the sewers for of such waste water.
inspection and maintenance. Also, they can
be easily concealed to prevent tampering. Thus, small bore sewer systems provide an
They function as flushing points during economical way to upgrade existing sanitation
sewer cleaning operations. facilities to a level of service comparable to
conventional sewers. Because of the lower costs
yy Vent: The sewers must be ventilated to
of construction and maintenance and the ability
maintain free-flowing conditions.
to function with little water, small bore sewers
yy Pumping Station: Lift stations are can be used where supply of water is low and
necessary where elevation differences do consequently low volume of waste water is
not permit gravity flow. Either residential generated per household.
or major lift stations may be used
Disadvantages with small bore sewer system
The Small bore system has the following
advantages: The principal disadvantage of the small bore
sewer system is the need for periodic evacuation
(a) Reduced water requirements. It is and disposal of solids from each interceptor tank
suitable where per capita waste water in the system. The interceptors must be cleaned
generation is very low. It is more suited in regularly. Without regular desludging, the sludge
rural areas where per capita water supply will overflow into the sewer system and cause
is low, making conventional sewer system sewer blockages.Thus, concerned Panchayat /
technically unfeasible. community should be able to exercise effective
(b) Reduced excavation costs. With the control over connections to the system and
troublesome solids removed, the sewers can cleaning of interceptors. Public authority may not
be designed with minimum depth, required be not able to perform frequent sewer cleaning.
to maintain self cleansing velocity when the
slope is kept minimum, excavation costs Applicability
are minimised. yy Small bore sewer is possible applied in area
(c) Reduced materials costs. Peak flows, which has septic tanks facilities.
for which the small bore sewers must be yy I t is an alternative to conventional sewerage
designed to handle, are lower than those where water supply is less.
experienced with conventional sewers

10
2.4.3 Conventional/Simplified Sewers 2.5 On-Site Wastewater Treatment Systems

In areas where sufficient water is available, the On-site wastewater treatment systems are
best and complete option for the wastewater designed to treat and mostly dispose of effluent on
collection is the conventional sewerage system.
the same property that produces the wastewater.
The sewerage systems are designed to collect
A septic tank and soakage pit combination is the
both grey water and black water and transport
them away from homes to the treatment plant or oldest and most common type of on-site system.
disposal point. The conventional sewerage system However, due to the groundwater pollution related
is a high-cost sanitation system; it is usually issues, newer advanced onsite system have came
deep laid as per the topographical situation. up in last 2-3 decades which represent scaled
The conventional sewerage system is discussed down versions of municipal sewage treatments.
in detail in the CPHEEO Manual for sewage
treatment. In India about 14 % of rural population is covered
by septic tank systems. The following sections
As an alternative to a conventional sewer system
deals with various technologies conventional
a simplified sewer system may be constructed. A
simplified sewer system is similar to a conventional (septic tank) to advanced on-site sanitation
one; however, it uses less conservative design systems are discussed.
criteria which mean that smaller diameters and
slopes can be used. Further, a simplified sewer 2.5.1 Septic Tanks
system is usually located on properties which are
accessible but not used for heavy traffic (cars, A septic tank is a combined sedimentation
etc.) which allows more shallow construction. and digestion tank where the retention time of
Hence, a simplified sewer system can be
sewage is one to two days. During this period,
considerably cheaper than a conventional one.
settleable solids settle down to the bottom. This
Design guidelines can be found at:
is accompanied by anaerobic digestion of settled
http://www.efm.leeds.ac.uk/CIVE/Sewerage/ solids (sludge) and liquid, resulting in reasonable
manual/pdf/simplified_sewerage_manual_full.pd reduction in the volume of sludge, reduction in
biodegradable organic matter and release of
Applicability: gases like carbon dioxide, methane and hydrogen
sulphide. The effluent although clarified to a large
The conventional/simplified sewerage system extent, will still contain appreciable amount of
is the ultimate sanitation solution and can be
dissolved and suspended putrescible organic
applied in all rural areas with adequate piped
solids and pathogens, as the efficiency is only 30-
water availability and funds are not a constraint.
If a simplified sewerage system is constructed 50 % for BOD and 60-70 % TSS removal.
special care should be taken for cleaning access
as a simplified sewer system may be more prone A typical two compartment septic tank is shown
to blockages than a conventional one. in figure 2.3.

11
Solid and Liquid Waste Management in Rural Areas

Figure 2.3. Structure of a septic tank, (Source: CPHEEO, 1993)

Hence, the effluent of septic tank should be every two to three years, or when the tank become
discharged into the small bore sewer or covered one-third full. The most satisfactory method of
surface drains. The outfall from such drains sludge removal is by vacuum tankers. Regular
should be connected to a small sewage treatment desludging activities require well-organized
plant. The second option of septic tank effluent community and public/private service providers.
discharge could be a soak pit. It should be noted
that the option using a soak pit may not be Applicability
environmentally friendly depending on the soil
type, groundwater table, population density and The conventional septic tank system is particularly
should generally be avoided if financial resources applicable for:
allow. i. Primary treatment of wastewater from
individual houses.
In order to control the effluent quality and prevent
the clogging of soakage pits, septic tank requires ii. It is suitable even for high water table
desludging. Though desludging frequencies vary, areas where drainage facility for effluent
it is generally recommended to desludge tanks discharge is available.

12
iii. Septage/Sludge collection and treatment
facility is available nearby.

Disadvantages of septic tank

i. Safe removal of septage from septic tank is


a problem. Due to lack of any such policy
septage is disposed of in open space, low
land areas or drains causing health and
environmental pollution.

ii. Lower treatment efficiency (30-60 % BOD


and SS Removal) and associated cost and
Fig. 2.5 A completely covered DRDO Biotank
space requirements for the construction of
soakage pit is comparatively higher. The effluent from the biotank, is released into
iii. Septic tank is incapability to handle reed bed. A reed bed system performs secondary
hydraulic shock loads, as peak flow disturbs treatment of the wastewater coming out of the
the settling zone and causes high suspended biotank. The reed bed system comprises of bed of
solids in the effluent. sand and pebbles along with reed plants capable
of natural amelioration of the wastewater coming
out of the bio tank. It eliminates smell, suspended
2.5.2 Biotank System
particulates, pathogenic and other microorganisms
The system is developed by DRDO for the more than 99%.
treatment of toilet wastewater. It is made of FRP
and consist of different chambers for the primary Natural reed plants-microbial consortium work
treatment of wastewater. efficiently at wide range of temperature and
effluent is very safe to discharge into environment
and may be used for irrigation purposes.

Fig. 2.4 DRDO Biotanks showing different chambers Fig. 2.6 Reed Bed system:

13
Solid and Liquid Waste Management in Rural Areas

Fig. 2.7 BioTank cum Reed Bed systems at DRDO, Tezpur, Assam

The effluent from the reed bed may be stored to ii. Reed bed system is useful to treat any
a tank for further use or may be released directly domestic waste water. However, its cost and
to the agro fields for irrigation when available or space requirement is the limiting factor for
in a drain. acceptance at household level.

Applicability
2.5.3 Advanced On-Site Systems
i. The system can be implemented in any
soil condition. It is more suitable for high To enhance the efficiency of septic tank system,
ground water table areas as there is no one of the recommended solutions is the provision
chance for ground water pollution
of anaerobic filter type and contact aeration
ii. Due to requirement of lesser area it is system for the treatment of septic tank effluent.
suitable even for high population density Such system can be used with system made of
areas where lack of space is a major concern brick, cement or package type. The package type
for construction of toilets
is based on well established Japanese technology
iii. Recurring cost is almost nil Jouksou. The later type advanced on-site systems
iv. Effluent is suitable for reuse in agriculture were developed with light weight materials
purpose. such as plastics and fibreglass and used in many
countries.
Limitations:
i. Trained manpower is required to implement Three types of advanced on-site systems are
the system discussed herewith in the following sections;

14
2.5.3.1 Package Type Anaerobic Filter System anaerobic filter where further removal of organic
matter takes place. Anaerobic filters are made
This type of package on-site treatment system can up of synthetic plastic media with high specific
be prefabricated of LLDPE (Low Linear Density surface area (Figures 2.8 and 2.9). The high
Polyethylene) or FRP (Fiber Reinforced Plastic) specific surface area not only prevents clogging
and can be installed easily in a very short time. but also provides intensive contact between the
It consists of two chambers, i.e., settling and wastewater and the fixed film anaerobic bacteria
anaerobic filter. The first chamber works as a septic for the fast degradation of organic matter. The
tank, where settleable solids are settled down treatment performance ranges 50-70 % for BOD
and further degraded anaerobically at the bottom and SS removal.
zone. The second chamber consists of upflow

Figure 2.8. Typical cross-sectional drawings of


prefabricated septic-tank anaerobic filter type systems
(Kazmi A. A. 2003)

Figure 2.9. Typical cross-sectional drawings of


conventional septic-tank anaerobic filter type systems
(IS 2470: Part 2: 1985)

A prefabricated package Anaerobic Filter Type


advanced on-site system was installed for the
treatment of black water at Navodaya Vidhyalala
in Shikarpur Gram Panchayat, near Roorkee
City. The project was sponsored by the Ministry
of Drinking water supply & sanitation. The
installation of the system is provided in Figure
2.10. The results of initial one month monitoring
Figure 2.10: A prefabricated Anaerobic Filter are provided herewith in Table 2.3
installed under Sponsored Project by MDWS
(Source Kazmi 2003)

15
Solid and Liquid Waste Management in Rural Areas

Table 2.3: Treatment performance of the aerobic bacteria for the fast degradation of organic
system for black water matter (Figure 2.7). The treatment performance
ranges 80-95 % for BOD and SS removal. (Kazmi
Parameter Influent Effluent Avg
Removal A.A, 2003).
Efficiency

BOD (mg/L) 673-1380 310-870 58

COD (mg/L) 1005-2100 772-1140 61

TSS (mg/L) 642-1288 226-956 75

Although, at the initial start-up stage, packaged


type septic tank- anaerobic filter system only
removes BOD and TSS around 58 to 75 %
respectively, but gradually, after formation of
biofilm on the media, it improves upon the
Figure 2.11: Typical cross-sectional drawings of package
effluent quality in terms of BOD and SS without
contact aeration system ( Kazmi 2003)
any requirement of power.
Applicability
Applicability
The package type contact aeration system is
The package type anaerobic filter system is
particularly applicable for :
particularly applicable for:
- Wastewater treatment from individual
- As an alternative to conventional septic
houses where high effluent quality is desired
tank from individual houses where higher
for reuse or to discharge to sensitive water
effluent quality is desired.
bodies.
- Septage/Sludge collection and treatment
- Rural areas having continuous power
facility is available nearby.
supply.
2.5.3.2 Package Contact Aeration System - Sensitive, tourist and un-approachable
locations
It consists of two chambers, i.e., settling and - Sludge collection and treatment facility is
contact aeration with synthetic plastic media. available nearby.
The first chamber works as a septic tank, where
settleable solids are settled down and further 2.5.3.3 Package Anaerobic Filter–Contact
degraded anaerobically at the bottom zone. Aeration System.
Second stage is high specific surface area fixed
film plastic media to retain high mass of aerobic It consists of anaerobic filter chamber, contact
micro-organism to degrade the organic matter in aeration chamber, sedimentation chamber and
the wastewater. The high specific surface area not disinfection chamber in series. The anaerobic filter
only prevents clogging but also provides intensive chamber separates, anaerobically decomposes
contact between the wastewater and the fixed film and stores solid matter in the influent. The contact

16
aeration tank is used for the aerobic treatment 2.5.4 On-Site Wastewater Disposal System
of effluent from the anaerobic filter chamber by (Soakage Pit)
the action of bio film grown on the surface of
contact media (Figure 2.12). Tablets of chlorine Soakage pit is a covered, porous-walled chamber
disinfectant are stored in a cylinder and gradually that allows water to slowly soak into the ground
dissolve to disinfect effluent. There is no sludge They do not provide any direct treatment and are
treatment in the system, and the sludge that based on the principle that the effluent gets treated
produced in the treatment process is collected by as it passes through the surrounding soil before
a vacuum truck for further treatment and disposal. entering the ground water table or other water
(Kazmi A.A, 2003). body. It is only applicable for highly permeable
sandy soil with deep groundwater table.. If the
ground is not sandy and water logged during wet
season the soakage pit may not work.

A diagram of a typical soakage pit is as follows


(Figure 2.13). Soakage pits, although easy to
construct, is usually an inadequate means of
disposing the wastewater because it release the
effluent over a small area which may clogged or

Figure 2.12. Typical cross-sectional drawings of


package anaerobic filter-contact aeration system
( Kazmi. 2003)

Applicability:

The system is particularly applicable for :


i. Wastewater treatment from individual
houses where high effluent quality is desired
for reuse or to discharge to sensitive water
bodies.
ii. Rural areas having continuous power supply
with availability of skilled manpower. Figure 2.13 Typical illustrations of Soakage pit
iii. Sensitive and un approachable locations (IS 2470 : Part 2 : 1985)

iv. Climatic variation is high from season to


season. lose its ability to treat the wastewater. Many cases
v. Septage/Sludge collection and treatment of groundwater bacterial pollution are reported
facility is available nearby. in shallow aquifer near the soakage pits. The
problems are aggravated due to as septic tanks
are not desludged regularly in the country. The

17
Solid and Liquid Waste Management in Rural Areas

soakage pits should generally be avoided if in India has shown that also in India a wide
financial resources allow. diversity of different decentralised wastewater
treatment technologies is already available. These
Since, it is one of the cheapest alternative for technologies can be classified into natural and
disposal of septic tank effluent, it should be built treatment systems. Built treatment systems
further can be classified in aerobic and anaerobic
• 20 m away from drinking water source
treatment systems. Combinations of different
• 20m away from another soakage pit types of technologies are often used. Which
• Adequate contact area with the surrounding technology is most suitable depends on various
soil to absorb the effluent in to the soil. In factors such as available land, available capacity
case of less permeable soils, larger pits will for operation, financial resources, energy supply,
required effluent quality and so on (Table 2.4).
be needed.
• Adequate openings shall be left in the A. Natural treatment systems:
walls of the pit to have the contact with the
surrounding soil i. Waste Stabilization Ponds - Anaerobic-
Facultative- Aerobic/maturation

Applicability ii. Duckweed Pond System


i. Where ground is permeable. iii. Constructed wetlands
ii. Population density is less & plot sizes are B. Built treatment systems:
large
a. Anaerobic
iii. Water is supplied through pipelines.
iv. Deep water table (at least 5 m below the i. Anaerobic baffled reactor
bottom of soakage pit). ii. UASB
v. Septic tanks are well maintained and
b. Aerobic
desludged regularly,
i. Package contact aeration systems
2.6 DECENTRALISED WASTEWATER
TREATMENT SYSTEMS ii. Extended Aeration systems
There are several technologies available for rural iii. Sequencing Batch Reactor systems
wastewater treatment all over the world. A survey
Table 2.4 : Classification of Various Wastewater Treatment Technologies
Technology Natural Aerobic/ Expected effluent Area Power Existence in
or built anaerobic/ quality (low, Requirement Requirement India
mixed medium, high)* (m2/person) kWh/ person. year
Waste stabilization natural mixed Medium to high 2.0-3.0 Nil All over India
pond system
Duckweed pond natural aerobic Medium to high 2.5-6.0 Nil Larger number
system in Punjab
Constructed natural aerobic Medium 1.5-2.5 Nil Less
wetlands experience in
India

18
UASB built anaerobic low 0.1-0.2 Only for Pumping All over India
in urban areas,
but very less
experience in
rural areas
Anaerobic baffled built anaerobic low 0.2-0.4 Nil All over India
filters
Package aeration built Mixed High 0.1-0.15 20-30 All over India
systems
Extended aeration built Aerobic High 0.1-0.2 15-25 All over India
systems
Sequencing batch built Aerobic Very High 0.05-0.1 10-20 All over India
reactor systems

Low Effluent Quality: BOD- 50-150 mg/L, TSS - 100-200 mg/L


Medium Effluent Quality: BOD- 20-50 mg/L, TSS- 50-100 mg/L
High Effluent Quality: BOD < 20 mg/L, TSS <30 mg/L
Very High Effluent Quality: BOD <10 mg/L, TSS < 10 mg/L

In general each treatment system needs a pre- the situation on the ground in rural areas.
treatment and may require, depending on the
aspired effluent quality, some post treatment. Apart from wastewater stabilization ponds and
In particular, constructed wetlands require a duckweed ponds there are only little experiences
good pre-treatment to remove settleable solids so far in rural India with different types and
and avoid clogging in the CW, while Anaerobic combinations of natural treatment systems and
Baffled Reactor and UASB requires good aerobic such systems should be piloted under Indian
post treatment to achieve the desired quality. conditions.

Natural treatment systems such as wastewater In the subsequent sections various proven
ponds or constructed wetlands have a good wastewater treatment technologies options are
potential for rural areas if space is no constraint suggested for Indian conditions. Based on the
(Starkl et al, 2013). The reason is that these end user water quality requirement, there can be a
systems have no or little energy requirement and combinations of these technologies.
are simple in operation and therefore suitable for

19
Solid and Liquid Waste Management in Rural Areas

20
2.6.1 Site Selection Criteria For Rural Small the odour-producing units to the habitation
Sewage Treatment Plants is recommended (CPHEEO 2014).
However, this distance can be reduced by
Ideally, a new site for a rural sewage treatment conducting public consultation. In addition,
plant is one that can be developed economically fragrant plants are one of the effective ways
without unnecessarily stressing the environment. to control odor nuisance around the sewage
Although numerous considerations, such as treatment plants.
social and environmental factors, are difficult iii. It is important that a wastewater treatment
to quantify, cost effectiveness and construction plant site be accessible to personal and
requirements can be quantified when choosing delivery persons at all times. Access to
among potential sites. fire and other emergency vehicles must be
available.
Sewage treatment facilities are almost universally
perceived by the general public to be unacceptable iv. In general, sites with special natural features
neighbours. Public opposition is strong; however, should be avoided. The development of areas
with early involvement of the Village Panchayat designated as wild, scenic, or recreational
in the planning process and a sincere desire by under the Act may be prohibited.
designers to listen and mitigate the public’s v. A site should accommodate present and
concerns; much of the opposition can be anticipated future requirements. As growth
minimized. Public involvement, or participation, occurs in the service area and treatment
is one of the most important elements in selecting requirements increase, the plant will likely
and evaluating alternative sites. Some other require additional space. The potential for
important considering factors are as follows; such demands should be considered when
i. The site should not be liable to flooding selecting a site.
and the elevation of the site should permit
the discharge the effluent by gravity to 2.6.2 Waste Stabilisation Ponds
the receiving streams or the level of the
irrigation area to be commanded in case of Waste stabilization ponds (WSP) are shallow
reuse for irrigation. man-made basin into which wastewater flows
ii. If the selected site is surrounded by and from which, after a retention time of few
residences, adequate measures should days a well-treated effluent is discharged. WSP
be taken to control odor from STP. If systems comprise of a series of ponds- anaerobic,
deodorization system is not provided an facultative and maturation ponds in series (Figure
aerial / peripheral distance of 100 m from 2.14). All these ponds have different functions.

Figure 2.14: Waste stabilization pond system

21
Solid and Liquid Waste Management in Rural Areas

Functions of different ponds under WSP wastewater are settled down as sludge. Inorganic
system solids such as grit and silt are conservative in
nature and remain as bottom sludge, while organic
Anaerobic and facultative ponds are designed for solids are degraded anaerobically and converted
BOD removal and maturation ponds for pathogen to carbon dioxide, methane etc.. These ponds are
removal, although some BOD removal also designed for 1-2 days HRT (Hydraulic Retention
occurs in maturation ponds and some pathogen Time) and 40-60 % BOD (Biochemical Oxygen
removal in anaerobic and facultative ponds. In Demand) removal can be expected. There must
case of waste water having low BOD level (< be two anaerobic ponds in parallel, so that the
150 mg/l), like grey water, maturation ponds may wastewater can be diverted to any of the pond
not be required. Moreover number of ponds for during desludging. For proper functioning of
treatment depends on nature of reuse / disposal anaerobic ponds desludging at every 1-2 years
of effluent. In case of agriculture use of treated interval is necessary (Figure 2.11). As anaerobic
effluent such maturation pond is not required. pond is one of the source of H2S foul odour due
to the reduction of sulphate to sulphide, options
Anaerobic Pond: It is 2.5-5 m deep pond, for covering and thereby recovering of biogas can
settleable inorganic and organic solids in the also be explored (Figure 2.16).

Figure. 2.15 An anaerobic pond of a WSP Figure 2.16 Desludging of anaerobic pond
(Source: Kazmi 2003)

Fig.2.17 Covering of base of pond with plastic sheet Fig.2.18 A WSP pond with boulders at the base of
Source- (Duncan Mara 1997) embankment. Source- (Duncan Mara 1997)

22
In areas having high water table there is chance Maturation Pond
of ground water pollution through stabilisation
pond system. It is equally true for any pond - These are 1-1.5 m deep and essentially designed
based technology of wastewater treatment. To for pathogen removal. The HRT of these ponds can
avoid such problem it is recommended that the be kept between 3-5 days. In general maturation
base of the ponds should be made impervious by ponds will be required only when the treated
having brick lining or covering base of the pond wastewater is to be used for unrestricted irrigation
with plastic sheet topped with soil (Fig-2.17). Use and has to comply with the WHO guideline of
of plastic sheet is a cheaper option and will not <1000 faecal Coli forms per 100 ml, and when
affect the overall cost of the system much. stronger wastewaters (BOD >150 mg/l) are to be
treated prior to surface water discharge. Effluent
To check the embankments of the pond from soil from a well designed WSP can be safely used for
erosion particularly during rainy season, there agriculture purpose or surface discharge.
should be provision of putting boulders at the base
of embankments up to the height of water level in If properly maintained and by desludging
the pond. It will help minimise the maintenance anaerobic ponds regularly, the Waste stabilization
of embankment of ponds (Fig 2.18). ponds (WSPs) are a low-cost, low-energy, low-
maintenance and, above all, the most sustainable
Facultative Pond. It is 1-1.5 m large shallow pond method of wastewater treatment. It is the most
receives pre-settled wastewater from anaerobic appropriate method of wastewater treatment in
pond. The functioning of the facultative pond India particularly in rural areas as the climate in
is based on algal-bacterial symbiosis. In the top India is very favourable for the efficient operation
aerobic layer, where oxygen is supplied through of WSP. The high temperatures that occur
algal photosynthesis is taken up by the bacteria for throughout the year in most of the country are
degrading non-settleable and dissolved organic especially favourable for anaerobic ponds.
matter. The algal and microbial biomass finally
settled at the bottom and degraded anaerobically. Applicability
A typical photograph of Stabilisation Pond System
in Dewatwal village (Ludhiana District, Punjab) is The Waste stabilization pond is particularly
shown in Figure 2.19. applicable for:
- Wastewater treatment in rural areas where
large unused lands, away from homes and
public spaces are available.
- Cheap labour is available for regular
maintenance of pond system.

2.6.3 Duckweed Pond System

Duckweed based wastewater treatment is


potentially suitable for small scale application
at rural level and for medium-sized facilities
at community, (peri-) urban level. Duckweed
Fig 2.19. A Stabilisation Pond System in Dewatwal is a group name belonging to botanical family
village, Punjab Lamnaceae that consists of four genera namely-

23
Solid and Liquid Waste Management in Rural Areas

Spirodela, Lemna, Wolffia and Wolfiella; first solids, bacterial and helminthic pathogens, some
3 genera are commonly found in India. It is organic compounds, ions of potassium, nitrogen,
cosmopolitan and found everywhere in organic phosphate and even heavy metals of wastewater to
nutrients rich stagnant water. It has very high a level, quite safe for disposal.
growth rate; at optimum nutrient environment
it doubles within 2-3 days. It tolerates wide range Duckweed based pond system can be used to give
of temperature- between 100-460C, depending further treatment to effluent from facultative pond
upon the genera. Size of the plant is very small. to meet more stringent BOD and TSS regulation
Wolffiella is the smallest plant having pin head and can generate some financial returns from
size, while Spirodella is the largest one, having its duckweed-fish cultivation. Some kind of pre-
size of 2-3 cm only. The most important feature treatment such as anaerobic pond/anaerobic
with this plant is that it contains up to 30 % edible baffled reactor and facultative pond are required
protein, vitamins A and C. It is a complete feed for duckweed pond.
for certain species of fish like Grass carp, Silver
carp, Common carp, Rehu and Mrigal. High yield Since duckweed is a free floating plant, it requires
of fish has a direct linkage with economic return only bamboos or PVC cubicles (4m x5 m), to check
and thus, employment avenue with the system. drifting of duckweed to one end, along with wind.
The system is being adopted in several developing Bamboos are more preferred as there is chance of
countries (Sascha Iqbal, 1999). theft of PVC articles in villages. Duckweed can be
found everywhere in stagnant water in villages. No
Since duckweed grow very fast in waste water, it other equipments are required for this treatment
uptakes nutrients from waste water very quickly process.
and form green mat over water (Fig. 2.20). Thus,
in addition to normal settling of waste water, there Required size of the pond depends on quantity
is bioaccumulation of nutrients in duckweed. of waste water generated per day. For a half mld
Duckweed has the ability to bio accumulate up of waste water, one hectare of pond surface area
to 99% of the nutrients, dissolved solids and even (0.5 hac for duckweed and 0.5 for fish pond)
heavy and toxic elements of wastewater up to is required. It is suitable for a village having
certain extent. These are permanently removed population of 4000-5000. Size of the fish pond
from wastewater as plants are harvested. Hence, normally should be half of the treatment pond.
it reduces Biochemical Oxygen Demand (BOD), However, additional larger size of the fish pond
Chemical Oxygen Demand (COD), suspended is more useful to have more economic return in
terms of fish production. Duckweed forms a green
mate over waste water, thus reduces the chance of
mosquitoes to breed in waste water.

Since duckweed grows very fast, its regular


harvesting is required. 25% of the area of
duckweed pond should be harvested daily. It
can be harvested manually through a simple net
device attached with a bamoo (Fig 2.21). Freshly
harvested duckweed is filled into a wickerwork
basket, where it remains for some time to allow
Fig. 2.20: A duckweed pond with bamboo barriers some water drainage and pathogen removal by
(Source: Iqbal Sascha, 1999) sunlight irradiation (Fig 2.22).

24
Fig. 2.21 Harvesting of duckweed through net (source Fig. 2.22 Freshly harvested duckweed
(Iqbal Sascha, 1999) (source (Iqbal Sascha, 1999)

There should be four nos. of fish feeding stations (Figure 2.23) at the fish feeding stations. It fixes
made up of bamboos in a pond. Freshly harvested biological clocks in fish and the same accumulates
duckweed should be put at any fixed time daily at the fixed time at fixed locations.

2.23. A pond with fish feeding stations Fig 2.24. Harvesting of various carp species fed
(Source: Iqbal Sascha, 1999) exclusively on duckweed. The vigorously jumping
fish indicate healthy fish and good pond water quality.
Up to 10 tonnes of fish can easily be harvested (Photograph: PRISM).
per year per hectare of fish pond (Fig 2.24). Little
specific information is available on the health and Smith (1987) reported acceptable levels
risks associated with bioaccumulation of heavy of heavy metals and pesticides in fish grown in
metals and toxins in fish and other animals fed on sewage stabilisation ponds. Adhikari et.al (2009)
duckweed grown in wastewater. However, there also reported that concentration of different heavy
is no chance of such effects when duckweed is metals tested in fish were below the permissible
grown in domestic sewage in rural areas as there level of WHO. The reason could be growth rate of
is no chance of heavy metals in sewage. Krishnan fish being much higher than the bioaccumulation

25
Solid and Liquid Waste Management in Rural Areas

of heavy metals, resulting in acceptable level of Applicability


such metals in fish.
The Duckweed pond is particularly applicable for:
Advantages of duckweed based treatment of - Large land area is available after facultative
waste water pond system.
 Duckweed grows rapidly and is capable - Cheap labour is available for the
of nutrient uptake under a wide range maintenance of the pond system.
of environmental conditions. Compared
to most other aquatic plants, it is less 2.6.4 Constructed Wetlands
sensitive to low temperatures, high nutrient
levels, pH fluctuations, pest, and diseases A horizontal flow constructed wetland (horizontal
(Dinges1982). flow CW) is a planted filter bed for secondary or
tertiary treatment of wastewater (e.g. grey water
 Duckweed and its associated microorganisms or black water). After primary treatment for solids
are capable of absorbing and disintegrating removal in a UASB or Anaerobic baffled reactor,
a number of toxic compounds (Landolt and the wastewater is fed at the inlet zone and flows
Kandeler 1987). horizontally through the porous filter medium
(sand or gravel) until it reaches the outlet zone
 Duckweed has been observed to efficiently
( Fig.2.25). The water is treated by a combination
absorb heavy metals (Landolt and
of biological and physical processes. The effluent
Kandeler 1987). This characteristic may be
of a well-functioning constructed wetland can be
detrimental if duckweed is used as feed.
used for irrigation and aquaculture or safely been
 When grown on nutrient-rich waters, discharged to receiving water bodies. Horizontal
duckweed has a high protein and a relatively flow CW are relatively inexpensive to build
low fibre content and is, thereby, suitable where land is affordable and can be maintained by
for use as high-quality feed supplement. the local community as no high-tech spare parts,
electrical energy or chemicals are required.
 Harvesting of duckweed plants from the
water surface is easy. A horizontal subsurface flow constructed wetland
 A complete duckweed cover on the is a large gravel and sand-filled channel that is
wastewater may efficiently prevent the planted with aquatic vegetation. As wastewater
growth of algae in the water body and result flows horizontally through the channel, the filter
in a clear effluent of low TSS content. material filters out particles and microorganisms
degrade organics. The water level in a Horizontal
 The presence of a dense duckweed mat has Subsurface Flow Constructed Wetland is
been reported to decrease and control the maintained at 5 to 15 cm below the surface to
development of mosquito and odour in a ensure subsurface flow (Tilley, et al 2008). To
wastewater body. avoid clogging of the wetland, pre-treatment is
 There is economic return and employment necessary. It has been established that a horizontal
avenue in term of pisciculture when filter bed area of about 2 m2 /PE is sufficient for
duckweed is used as fish feed grown on the complete secondary and tertiary treatment of
domestic sewage. wastewater including the removal of pathogenic
germs (Sonavane et.al 2008), (CPCB, 2008).

26
this. Another management technique used to
be prevent clogging is draining the wetland
two to three times a year during the growing
season. Simply unplug the wetland, allow it to
completely drain, and immediately re-plug. This
also encourages root penetration to the bottom
of the wetland, particularly in the few years of
operation.

Selection of species for Constructed wetland


Figure 2.25. Horizontal flow constructed wet land:
Tilley et al. (2008)
With the available experience the following list of
Pre-treated wastewater flows slowly through the species can be given:
porous medium under the surface of the bed in i. Phragmites australis (reed)
a horizontal path until it reaches the outlet zone.
At the outlet, the water level is controlled with an ii. Phragmites karka (reed)
adjustable standpipe. A common design suggests iii. Arundo donax (mediteranean reed)
a water level of about 60 cm which is maintained
iv. Typha latifolia (cattail)
at ca. 5 to 15 cm below the surface of the CW to
avoid anaerobic conditions in the bed. v. Typha angustifolia (cattail)
vi. Juncus (bulrush)
An important role of treatment efficiency is the
oxygen supply. Horizontal filter beds have a very
small external oxygen transfer and a smaller inlet The vegetation is a critical component for the
compared to a vertical flow constructed wetland. successful operation of wetlands. For horizontal
Therefore, they require a larger area. If topography CW, in principle, all helophytes can be used, which
allows for gravity flow, horizontal flow filters are are deep rooted and oxygenate the Rhizosphere
not dependent on energy and can be operated by through the roots.The most common maintenance
gravity. The treatment process of constructed activities are pulling out undesirable plant species
wetlands is based on a number of biological and such as willow tree saplings, removing dead
physical processes (adsorption, precipitation, vegetation and cleaning pipes. Other maintenance
filtration, nitrification, predation, decomposition, activities include replanting, fertilizing, cleaning
etc.) (Hoffmann et al. 2010). / brushing screens and pipes, and installation of
barriers to exclude deer.
Maintenance of all wetlands can include dredging,
sediment build-up, mowing of impoundment Planting Techniques
structures to control trees, and pest control of
insects, muskrats, and beavers. The water level Planting of reeds can be done in the following
should be maintained 5cm below the wetlands ways:
gravel surface to control/ eliminate odors. The - Reeds can be planted as rhizomes, seedlings
gravel at the inlet end of some systems if clogged, or planted clumps.
require the first 30 to 60cm of gravel to be - Clumps can be planted during all seasons.
replaced. Dosing with small doses may prevent (2 / m2)

27
Solid and Liquid Waste Management in Rural Areas

- Rhizomes grow best when planted in Pre- of Gravel media etc. However these systems are
Monsoon. (4 - 6/ m2) quite cheaper than the conventional treatment
- Seedlings should be planted in Pre-Monsoon systems. In addition to low capital, operational
(3 - 5/ m2) and maintenance cost, treatment of domestic
waste through constructed wetland technology in
localized areas affects sufficient savings in:-
Vegetation Management
• Laying long distance sewage pipelines
The vegetation is a critical component wetlands for collecting and transporting it to long
and successful performance depends on a distances for centralized treatment.
relatively dense stand of healthy plants. Disease • Expenditure on energy and maintenance
and insect infestation can cause problems, but this of conventional treatment system cost of
has not been experienced to date at operational technical manpower.
constructed wetlands. The oxygen transfer
capability of the plant can be overwhelmed by Recycling and reuse of root zone treated water in
very-high-strength wastes, and affected plants irrigation and washing of vehicles etc. will reduce
may die. A major threat to some of the emergent pressure on drinking water and also will save
vegetation used in constructed wetlands is damage high cost involved in treating water for drinking
from muskrat and nutria. These animals use both standards which is generally used for above
Typhalatifolia and scirpus as a food source and for purposes (Vipat, 2003)
nesting material. The most common maintenance
activities are pulling out undesirable plant species Applicability
such as willow tree saplings, removing dead
vegetation and cleaning pipes. Other maintenance - For all kind of pre-treated wastewaters.
activities include replanting, fertilizing, cleaning - Availability of large land areas
/ brushing screens and pipes, and installation
- Availability of cheap labour for the
of barriers to exclude deer. The need to control
operation and maintenance of the system
turtles and burrowing animals has also been
reported (Taylor, 1998). Several techniques that
2.6.5
Phytorid Technology for Sewage
may be used to harvest wetland plants include
Treatment
thinning or weeding vegetation using modified
farm equipment or floating harvesters, controlled
Phytorid technology is developed by NEERI
burning on as area basis to maintain the system’s
for sewage treatment NEERI is a government
hydraulic profile, and complete removal of
research institute under Council of Scientific
the excessive accumulations of litter and the
and Industrial Research. This is one of the most
upper sediment or soil layer using construction
reputed laboratories for environmental research
equipment (Robert, 1991).
and consultancy. This technology has world
patent to its credit. The national environmental
Cost Benefit
policy recommends use of constructed wetland
systems for efficient sewage treatment.
The cost of installing a constructed wetland
varies depending on quantity of water to be
Simple Solution for sewage treatment: The
treated, pollution load, site location, availability
main objective of the proposed project is to

28
provide a simple, feasible, practically sound, Advantage of Phytorid technology: Treatment
eco-friendly, maintenance free and cost-effective efficiencies of the removal of fecal coliforms,
technology, which can handle the sewage waste BOD, COD, nutrients are up to 80%, which is
water treatment leading to reuse of treated greater than the traditional chemical methods
water for purposes like gardening. Phytorid is
yy It is a very cost effective technology when
a scientifically developed systematic treatment
compared with the traditional wastewater
methodology for waste water.
treatment methods.
yy hytorid combines Physical, Biological and
P yy Since it utilizes natural vegetation and
Chemical processes rhizosphere microorganisms, it is eco-
yy Works on gravity friendly method of treating sewage.
yy An important factor to be considered is the
yy No electric power requirement
aesthetic improvement that is provided by
yy Scalable technology this methodology.
yy Easy to maintain yy No mosquitoes and odor nuisance

yy Adds to aesthetics yy The treated water can be used for


enhancement of environmental architecture
yy Cost effective such as roadside fountains.

Typical Design features: The sub-surface yy he quality of treated water is comparable


T
flow type, Phytorid system is proposed for the to irrigation standards.
treatment of sewage or domestic wastewater
which will consists of a basin or a channel with Methodology: The treatment process consists
a barrier to prevent seepage, but the systems / of primary treatment plant followed by Phytorid
cells / beds contain a suitable depth of porous treatment system. The hydraulic loading shall
media. A primary treatment facility would also be be started with 40% capacity in the beginning
constructed along with basic for effective removal till the time of acclimatization of the plants to
of solids and thus reduces the marginal BOD. the hydraulic load and shall be later increased to
100%. The further loading and efficiency shall be
The porous media also supports the root structure monitored to establish how much more of either
of emergent vegetation. The design of the hydraulic or BOD load can be effectively used.
Phytorid system assumes that the water level in This would entirely depend upon the variation in
the cells will remain below the top of the filter the sewage characteristics used for treatment.
media.
Land area requirements:The total areas required
The vegetation to be utilized for the said Phytorid for sewage treatment plant for a capacity of 25m3/
system is very important. Various species of day is approximately 30 m2. The area includes
aquatic plants have been utilized to attain area requirements settler tank, Phytorid bed and
maximum efficiency in the treatment of domestic treated water collection tank.
wastes. These include species like Phramites
australis, Phalaris arundinacea, Glyceria maxima, Treatment efficiencies: Phytorid system being
Typha spp., other common grasses etc. natural method, the final efficiencies as indicated

29
Solid and Liquid Waste Management in Rural Areas

in Table 2.5, will be achieved after the system is Primary and Secondary treatments are achieved
stabilized which may require a period of 6 months in the SBT. The organic & inorganics in waste
after commission. water is consumed and converted into useful by-
products and simultaneously water of desirable
Table 2.5. Performance of Phytorid Technology quality is produced. SBT thus removes BOD,
COD, Ammonia, Nitrogen, Nitrate nitrogen
Pollutant Performance suspended solids bacteria, colour, odour. The SBT
(% removal) is ideal for treating waste water less than 5 MLD.
Total suspended solids 75-95
Biochemical oxygen demand 70-80 Soil Bio Technology (SBT) is an efficient process
of synthesis to completely utilize solids and
Chemical oxygen demand 60-75
liquids. It is economical in capital and recurring
Total nitrogen 60-70 costs. It has a simple looking construction, free
Phosphate 50-60 from conventional electro-mechanical systems
Fecal coliform 85-95 which are prone to breakdowns. It efficiently
integrates the physical,chemical and biological
Operation and Maintenance: This technology processes into a single aerobic system based on
is natural system; as a result operation is mostly natural biophysical and bio-chemical principles.
passive and requires little operator intervention. A specified additive is added in a predefined
Requirement for area can change on various proportion. SBT is a synthesis process which
factors such as load (kg BOD / day), ambient harnesses the energy, carbon and other elements
temperature, topography of the region, flow of the waste and converts them to precious “ Bio-
characteristics, etc. Maintaining uniform flow energy” products like vegetation, energy rich
across the Phytorid system through inlet and outlet soil, complete Bio-fertilizer and water. It offers
adjustment is extremely important to achieve the a bacterial removal of approx. 99.99 % thus
expected treatment performance. Sampling of ensuring a healthier environment in a sustained
inlet and outlet will be carried out for a period of manner without any side effects.
3 months every fortnight after stabilization of the
treatment systems of first one year. Some of the salient features of SBT:
yy Rejuvenation/creationof soil.
2.6.6 Soil Bio Technology (SBT) for Sewage
Treatment yy Can be utilizable for all sorts of organic and
inorganic molecules present in the effluents.
This technology has been developed by IIT, yy No req. of electricity and chemical
Mumbai. SBT engages three fundamental (Electricity requirement only for pumping).
process of Nature – Photosynthesis, respiration
yy Generate Bio-energy
and mineral weathering. This is achieved by soil
micro-organisms which are regulated by soil yy Little space area as per requirement per
micro –organisms (geophagus earthworms). person ( 100 litre per day) is 0.021 m2

30
2.6.7 Anaerobic Baffled Reactor (ABR)

An anaerobic baffled reactor (ABR) is an improved


septic tank, which, after a primary settling
chamber, uses a series of baffles to force all kind
of wastewater to flow under and over the baffles
as it passes from the inlet to the outlet (Figures
2.28, 2.29 & 2.30). The wastewater is introduced
into the chamber at the bottom, leading to an
enhanced contact with the active biomass which
results in an increased retention and anaerobic
degradation of suspended and dissolved organic
Fig 2.26 Application of SBT
pollutants. ABRs are robust and can treat a wide
range of wastewater, but both remaining sludge
and effluents still need further treatment in order
to be reused or discharged properly (Tilley et al.,
2008).

Fig 2.27 Design of a typical SBT

Fig. 2.28. Anaerobic Baffled Reactor;


(Source: Morel & Diener 2006)

Fig. 2.30. An ABR after completion


(http://cseindia.org/content/wastewater-recycling)
Fig. 2.29: An ABR under construction

31
Solid and Liquid Waste Management in Rural Areas

ABRs are suitable for a wide range of wastewater,


but its efficiency increases with higher organic
load. The system must be followed by polishing
aerobic treatment such as facultative pond,
constructed wetland etc., ABRs take advantage
of the easy construction, low cost and strong
resistance of septic tanks but allow for much
higher treatment efficiency. The BOD removal
efficiency is reported between 60-80 %, much
higher than conventional septic tank. The most
important design parameter is the upflow velocity
which should not exceeds 2 m/h. The organic
loading should also be less than 3 kg COD/m3/d. Figure 2.31. Schematic Diagram of UASB based plant
(Source Kazmi A. A.2003)
Applicability
a separate settler. The settling zone is relatively
yy Wastewater treatment in rural areas where
free of the mixing effect of the gas, allowing the
land is limited.
solid particles to fall back into the reactor. The
yy Septage/Sludge collection and treatment clarified effluent is collected in gutters at the
facility is available nearby. top of the reactor and removed. The biogas has
methane content typically around 75 percent and
2.6.8.
Upflow Anaerobic Sludge Blanket may be collected and used as a fuel or flared.
(UASB) Reactor
A properly designed UASB reactor eliminates the
The UASB is a high rate suspended growth type need for mechanical mixing and has few moving
of reactor in which a pre-treated raw influent is parts. If gravity distribution of the influent is
introduced into the reactor from the bottom and possible, the treatment plant may need pumps
distributed evenly. “Flocs” of anaerobic bacteria only to remove excess sludge from the reactor
will tend to settle against moderate flow velocities. periodically for transfer to drying beds.
The influent passes upward through, and helps
to suspend, a blanket of anaerobic sludge. In India, many UASB plants are working
Particulate matter is trapped as it passes upward satisfactorily for sewage treatment in urban areas
through the sludge blanket, where it is retained of India. The BOD and TSS removal efficiency
and digested. Digestion of the particulate matter generally varies from 60 to 70 %. In some areas
retained in the sludge blanket and breakdown corrosion and odor issues were noted for systems
of soluble organic material generates gas and treating high incoming sulphates in the sewage.
relatively small amounts of new sludge. The
rising gas bubbles help to mix the substrate with However, the main problem in achieving high
the anaerobic biomass (Figure 2.31). quality effluent was due to non-suitable post
treatment method. Generally, The 1-day HRT
The biogas, the liquid fraction and the sludge are pond is used for the post treatment of UASB
separated in the gas/liquid/solids (GLS) phase effluent., it requires very large area and able to
separator, consisting of the gas collector dome and remove additional 20-40 % BOD & TSS. The

32
final effluent BOD of UASB & pond system primary sedimentation zone in which settled
varies between 20-50 mg/L. sludge is stabilized by anaerobic digestion.
The treatment efficiency of the chamber is
Apart from wastewater stabilization ponds and in the range of 30 % BOD removal. Second
duckweed ponds there are only little experiences stage is the aerobic zone along with plastic
so far in rural India with different types and media installed inside the tank which in turn
combinations of natural treatment systems and increases the surface area and retain micro-
such systems should be piloted under Indian organism long enough to digest the organic
conditions. substance remained. Final stage involves
the sedimentation where organic wastes
In rural areas, the treated wastewater is generally are settled in the Sedimentation zone. The
used for irrigation, if medium to low quality settled waste in the bottom of the tank is
effluent is needed, then the system is very
pumped back to the primary sedimentation
promising. In addition, very limited experience
zone as a return sludge having active
is available on the application of UASB in rural
biomass (MLSS) to increase the efficiency
areas; there is a need of piloting the system for
of the system and ensure the effluent quality
rural conditions.
meets the stipulated standards (Fig. 2.32).
Applicability

1. In rural areas where electricity is available


for pumping the wastewater.
2. Where land cost is high and limited area is
available.
3. Influent sulphates in the wastewater is low
4. Strength of wastewater is high.

2.6.9 Settling-Contact Aeration System

It can be a concrete, steel, LLDPE or FRP tank Fig. 2.32: A Typical Package Contact Aeration System
which can be used anywhere for aerobic treatment (Source: Nishihara Env. Technology, Japan)
of sewage. It is ideal for schools, hospitals and
other complexes in rural areas. The system The system is compact tubular tank easy to
consists of three zones, Solid Separation Zone, transport. Sludge removal is once in 3 years.
Aeration Zone and Final Sedimentation Zone It works from no load to peak load. Can take
respectively. weight up to 30 tones, hence may be installed
underground and may be relocated or upgraded
A. A settling –contact aeration system – steel easily. Many Package Contact Aeration systems
tank. Solid Separation Zone transforms were installed for various residential housing
colonies, institutions, offices and hotels all over
the influent solids to settled solids while
India.
allowing scum to float on the surface. It is a

33
Solid and Liquid Waste Management in Rural Areas

B. A settling–contact aeration system– 12 hrs where as larger (2nd tank) has of two
LDDPE type. A simplified method for days. 1st tank works as anaerobic settling
settling - contact aeration system has chamber and 2nd as aerobic & treatment
been developed and tested. The system chamber (Fig 2.33). In the 2nd chamber,
is connected with a toilet block having 3 air is provided through air pump having
nos. of WCs and one bath used by over 20 flow of 60-80 lpm. It is desirable to provide
persons per day. The system has two Linear air for 24 hrs. However, due to limited
Low Density Polyethylene (LLDPE) tanks elecric supply it is not feasible always.At
of different sizes. They are connected in reduced air supply level of BOD and other
series with inlet chamber of waste water. parameters of waste water will increase.
Smaller tank (1st tank) has retention time of

Figure. 2.33 LDDPE made settling– Fig. 2.34 Coirs used as growth medium
contact aeration system

Table 2.6

Parameters Value (mg/l) except pH, of effluent


Aerobic Anaerobic
condition condition
BOD 7 65
COD 19 125
TKN 3.4 35
Phosphorus 2.2 10
TSS 25 52
Fig 2.35 Schematic diagram of settling –contact aeration pH 7.5 7.4
system

34
Air pump operates on 50 watt electricity. Air 2.6.10 Extended Aeration
diffuser is provided at the bottom of the tank
through non- return valves fitted in ½”- ¼’’ inter The extended aeration process is a modified
connecting G.I. pipes at multiple points. For the activated sludge process which provides biological
bacteria growth media, coir rope which is having treatment for the removal of BOD and TSS under
huge rough surface area can be used (Jha, P.K, aerobic conditions. Air may be supplied by
2010). Such growth medium is easily available in surface or diffused aeration to provide the oxygen
most of rural areas and much cheaper than other required to sustain the aerobic biological process
plastic media. Required length of 5-10 coir ropes As depicted in Figure 2.36, wastewater enters
can be tied at one end and with a brick/ stone and the treatment system and is typically screened
put in aeration chamber. In this way coirs remain and degritted immediately to remove large
submerged and float in waste water (Figs. 2.34) suspended, settleable, or floating solids that
Removal of coir is much easier as they are tied could interfere with or damage equipment
and pulled out of chamber easily. A schematic downstream in the process. If the plant requires
diagram of the system is depicted (Fig 2.35). the flow to be regulated, the effluent will then
Treated waste water is stored in a storage tank flow into equalization basins which regulate peak
from where it is reused for agriculture purposes. wastewater flow rates. Wastewater then enters
Results of different parameters of effluent under the aeration tank, where it is mixed and oxygen
aerobic and under anaerobic conditions from is provided to the microorganisms. The mixed
different plants using same design and methods liquor then flows to a sedimentation tank where
are presented in Table-2.6. Effluent is chlorinated most microorganisms settle to the bottom of the
to make bacteria free, whenever required. Such sedimentation tank and a portion is pumped back
effluent, under aerobic condition, is free from to the incoming
any odour and colour making suitable for use
in agriculture and other non- potable purposes. wastewater at the beginning of the plant. This
Effluent from anaerobic condition can be used for returned material is the return activated sludge
agriculture purpose. (RAS) (US EPA, 2000). The material that is not
returned, the waste activated sludge (WAS), is
Applicability removed for treatment and disposal. The clarified
wastewater then flows over a weir and into a
The Package Contact Aeration System is
particularly applicable for:
- Wastewater treatment in rural areas
connected to small bore sewers or
conventional sewerage or on-site where
high effluent quality is desired for reuse or
to discharge to sensitive water bodies.
- Rural areas having continuous power supply
for much better quality of effluent
- Sensitive and unapproachable locations
- Where land cost is high and limited area is Figure 2.36 A typical flow sheet of Extended Aeration
system (Source: USEPA 2000)
available

35
Solid and Liquid Waste Management in Rural Areas

collection channel before being diverted to the Plants are fully automatic and require least
disinfection system. manpower for maintenance.

Thousands of extended aeration plants and its


variants such as oxidation ditches, sequencing
batch reactor are installed all over the globe for the
treatment of rural area wastewater and working
very efficiently. The extended aeration process
has a special ability to handle extremely high
organic and hydraulic shock loads, no washout of
biomass, reliable performance. More than 95 %
BOD removal is reported in many plants.

Applicability

The Extended Aeration System is particularly Figure 2.37. A Typical Cycle of Sequencing Batch Reactor
applicable for: (USEPA 2000)

- Wastewater treatment in rural areas


connected to small bore sewers or a. The SBR is a time-oriented, periodic
conventional sewerage where high effluent process that can be designed and operated
quality is desired for reuse or to discharge to simulate virtually all conventional
to sensitive water bodies. continuous-flow activated sludge systems,
from contact stabilization to extended
- Large villages with wastewater discharge >
aeration.
500 m3/d
b. Improved effluent quality: extended aeration
- Rural areas having continuous power
mode, a special ability to handle extremely
supply.
high organic and hydraulic shock loads, no
washout of biomass, reliable performance.
2.6.11 Sequencing Batch Reactor Process
More than 95 % BOD removal advantages
same as extended aeration processes.
A sequencing batch reactor (SBR) is another type
of extended aeration activated sludge system in c. No primary & secondary settling tanks,
which equalization, aeration and clarification all no return sludge pumping, hence lesser
occur in a single reactor, by cycling through a operation & maintenance.
series of steps: fill with anoxic mixing, aeration, d. Low volume of sludge production.
settling, and decanting. Typically, sludge is wasted Lower Annual Operating Costs due to
during the decant phase of the cycle (Figure low volume sludge pumping, low waste
2.37). Typically two or more batch reactors are sludge production, savings in precipitating
used to optimize system performance. SBR chemicals (optimized biological
phosphorous removal) and savings for cost
systems are typically used for flow rates starting
of operating personnel and equipment.
from 0.1 MLD onwards and have the advantages
of operational flexibility and minimal footprint. e. Because of the flexibility of working in time

36
rather than space, the operating policy can be Proper management of septage from rural areas is
modified to meet new effluent limits, handle the need of hour.
changes in wastewater characteristics, and
accommodate the fluctuations in seasonal 2.7.1 Desludging of Septic Tanks and Advanced
flow rate, all without increasing the sizes of On-Site Systems
the physical plant.
f. Proven effluent quality below 10 mg/l In most of the cases the septic tanks are desludged
BOD5, TSS and COD < 50 ppm, T-N to 10 manually. This is considered as an unpleasant and
mg/L and T-P to 2 mg/L. repulsive job since the sludge (including fresh
excreta) generally gets spilled around the tank
during emptying, and poses a risk of transmission
Applicability of diseases of faecal origin. The most satisfactory
method of sludge removal is by vacuum tankers.
The SBR technology based system is particularly Though desludging frequencies vary, it is generally
applicable for : recommended to desludge tanks once every three
- Wastewater treatment in rural areas to five years, or when the tank becomes one
connected to small bore sewers or third full. Frequent desludging also helps reduce
conventional sewerage where high effluent the pollution levels in the liquid effluent, which
quality is desired for reuse or to discharge normally enters waterways untreated.
to sensitive water bodies.
2.7.2 Treatment of Septage
- Rural areas having continuous power supply
with availability of skilled manpower. Co-treatment of septage along with domestic
- Large villages with wastewater discharge > sewage at a sewage treatment plant (STP) of a
500 m3/d nearby city is a feasible and acceptable alternative
for septage treatment. Though septage is much
- Sensitive and un approachable locations concentrated in its strength than the domestic
- Where land cost is high sewage, its constituents are similar to municipal
wastewater. Sewage treatment plant should have
- Nutrient removal is required for discharging
an adequate capacity in order to accept the septage
the treated effluent in lakes and oceans
without hampering the normal functioning of
- Climatic variation is high from season to other processes. The nearby city municipality
season. should check the incoming load to the STP, if it is
lower than the design capacity, then the difference
2.7 SEPTAGE AND SLUDGE TRATMENT in BOD and SS load can be accepted as septage.
It is perhaps the best option as most of the sewage
Septage is the sludge generated from septic tanks, treatment plants in the country are working under
advanced-on-site systems, package plants, which capacity.
is a fluid mixture of untreated and partially treated
sewage solids, liquids and sludge of human When the distance or the capacity of the plant
or domestic origin. It has an offensive odour, becomes a limiting factor, it is not a feasible
appearance and contains significant levels of oil, option to transport and treat the septage to the
grit, hair, debris and pathogenic microorganisms. sewage treatment facilities. In this case treatment

37
Solid and Liquid Waste Management in Rural Areas

plants specially meant for septage treatment type of plants, climatic conditions, soil texture and
becomes an attractive option. Independent quality of effluents. The total discharge of effluent
septage treatment plants are designed specifically is regulated in such a way that it is consumed
for septage treatment and usually have separate within 12-18 hours and there is no standing water
unit processes to handle both the liquid and solid left in the trenches. Through this technique, it is
portions of septage. These facilities range from possible to dispose off 0.3 to 1.0 ML of effluent
mechanical dewatering, sludge drying beds, per day per hectare. This technique utilizes the
Waste stabilization ponds etc., The benefit of entire biomass as living filter for supplying
using these treatment plants is that they provide nutrients to soil and plant; irrigation renovates
a regional solution to septage management. Many the effluent for atmospheric re-charge and ground
septage treatment plants use lime to provide both storage. Further, as forest plants are to be used for
conditioning and stabilization before the septage fuel wood, timber or pulp, there is no chance of
is de-watered. Dewatered sludge can be used as pathogens, heavy metals and organic compounds
organic fertilizer after frying and composting. to enter into the human food chain system, a point
The remaining effluent/filtrate/supernatant can that is a limiting factor when vegetables or other
be released to another treatment process such crops are grown with sewage.
as WSP, Anaerobic baffled reactor, constructed
wetland or combination of these of extended
aeration activated sludge where it can undergo
further treatment and then finally can be safely
discharged.

For the treatment of septage from rural areas the


following option is suggested;

Septage Pretreatment ----- lime stabilization


(optional)-------- Pumping------- Sludge Drying
beds (FRP covered in regions of high rainfall)
------------Dewatered & Dried Sludge----
Composting----- Reuse as Organic Fertilizer;
Filtrate of Sludge Drying Bed------ Pumping ----
-- Anaerobic Baffled Reactor/Covered Anaerobic
Ponds ------- Facultative ----- Aerobic/Maturation
Ponds----- chlorination ----- discharge

2.8 KARNAL TECHNOLOGY

The Karnal Technology involves growing trees


on ridges 1m wide and 50cm high and disposing
of the untreated sewage in furrows (Reference
Figure 2.38. Outline of Karnal technology and a STP
source not found.). The amount of the sewage/ based on Karnal Technology
effluents to be disposed off depends upon the age, (punenvis.nic.in/water/technologies3.htm)

38
Though most of the plants are suitable for utilizing sludge run into the danger of contracting infection
the effluents, yet, those tree species which are fast or disease. The workers should be aware of this.
growing can transpire high amounts of water and The workers should wash themselves thoroughly
are able to withstand high moisture content in after being around wastewater or practising first
the root environment, are most suitable for such aid if when an injury occurs in the treatment or
purposes. Eucalyptus is one such species, which sewer systems. These are the biggest steps in
has the capacity to transpire large amounts of avoiding problems with sickness and infection
water, and remains active throughout the year. from the work.

This technology for sewage water use is relatively The following preventive measures should be
cheap and no major capital is involved. The taken to prevent any kind of diseases;
expenditure of adopting this technology involves
cost of making ridges, cost of plantation and their 2.9.1 Personal Hygiene Against Pathogen
care.
The worker should take precautions because a
This system generates gross returns from the sale large number of coliform 835 groups, various
of fuel wood. The sludge accumulating in the kinds of micro-organisms, and egg parasites exist
furrows along with the decaying forest litter can in sewage. The workers should strive to maintain
be exploited as an additional source of revenue.
good health by taking care of the following points:

As the sewage water itself provides nutrients and • Wear clean uniform, work boots, etc.
irrigation ameliorates the sodic soil by lowering
the pH, relatively unfertile wastelands can be used • After work and before having a meal,
for this purpose. This technology is economically always wash hands and disinfect them.
viable as it involves only the cost of water • After work, take a shower if possible.
conveyance from source to fields for irrigation and
does not require highly skilled personnel as well. • Do not enter the offices and lounges wearing
This technology seems to be most appropriate dirty clothes.
and economical viable proposition for the rural
• If necessary, take vaccinations against
areas as this technology is used to raise forestry,
which would aid in re-storing environment and to tetanus, leptospirosis fever, and so on.
generate biomass. Five systems have been setup
in Madhya Pradesh, 1 in Uttar Pradesh and 1 in 2.9.2 Health Check
Uttarakhand
Workers should have health check once a year so
2.9 WORKERS SAFETY ISSUES as to maintain their health, and prevent illnesses
or detect them at an early stage. The results of the
Workers who come in contact with wastewater or health check should be maintained as records.

39
Solid and Liquid Waste Management in Rural Areas

CHAPTER - 3
TECHNOLOGICAL OPTIONS FOR SOLID WASTE MANAGEMENT

3.1 SOLID WASTE MANAGEMENT IN composting by using systematic and scientific


RURAL AREAS methods.

Solid waste management in rural areas is perhaps Principle of composting


the most neglected aspect of environmental
sanitation. However, it is comparatively much Decomposition and stabilisation of organic waste
easier to maintain solid wastes in rural areas than matter is a natural phenomenon. Composting is an
in urban areas. A number of waste prevention organised method of producing compost manure.
techniques are available, and they are commonly Compost is particularly useful for organic matters.
summarized as popularly known as 4Rs: reduction, In rural areas there is higher percentage of organic
reuse, recycling and recovery. To overcome the matters making more applicability of composting
problem of solid wastes, following steps need to technology.
be taken:
i. Wherever possible, waste reduction should Composting can be carried out in two ways i.e.,
be preferred. aerobically and anaerobically. During aerobic
ii. Every effort should be made to reuse composting aerobic micro-organisms oxidize
produced wastes organic compounds to Carbon dioxide, Nitrite and
iii. Recycling should be the third option for the Nitrate. Due to exothermic reaction, temperature
wastes. of the mass rises up to 650 C. At such temperature
mesophilic bacteria present in the heap die off and
iv. There are several options for recycling.
condition inside heap becomes anaerobic. To
Such options should be selected taking in
maintain aerobic condition with environmental
view social and economical acceptability.
temperature inside heap, it is churned up
v. Attempts should be made to recover
side down at regular intervals. The process is
materials or energy from waste which
comparatively faster than anaerobic condition.
cannot be reduced, reused or recycled.
During anaerobic process, the anaerobic micro
organisms, while metabolising the nutrients,
In rural areas most of the household contains
break down the organic compounds through a
organic wastes, with little quantity of inorganic
process of reduction. In this case temperature
wastes and it is completely free from toxic wastes.
inside the heap does not raise much. The gases
Due to organic nature of wastes, composting is
evolved are mainly Methane and Carbon dioxide.
the most suitable, sustainable and environment
friendly method of recycling and reuse of solid This process does not require churning. It takes
wastes in rural areas. Composting of household longer time than aerobic composting.
wastes in rural areas is an age old practice. As per
the information available in literatures, these are 3.1.1 Advantages of composting
based on the practices adopted in field conditions. i. Large amounts of vegetation, such as
In recent years there has been improvement of crop remains, garden weeds, kitchen and

40
household wastes, hedge cuttings, garbage, can be prepared from a wide range of organic
etc, are put to use. materials including dead plant material such as
ii. When properly made, compost becomes crop residues, weeds, forest litter, cattle dung and
immediately available as plant food without kitchen wastes. Compost making is an efficient
the need to be first broken down by soil way of converting all kinds of biomass into high
microorganisms. value fertilizer that serves as good alternative to
farmyard manure, especially for crop-growing
iii. Compost does not cause excessive weed households without livestock. In this method
growth, as is the case with ordinary farm composting materials are put in layers (Fig 3.1)
manure.
iv. Good crops can be obtained without the Description
need for extra chemical inputs.
This method of making compost involves the
v. All farmers, regardless of their financial
construction of a simple, rectangular brick tank
abilities, can make and use compost.
with enough spaces maintained between the
bricks for necessary aeration (Figs. 3.2, 3.3).
3.1.2 Limitations for composting
The size of the tank is 3m x 1.8 m or 3.6 m x
i. Compost requires a lot of labour to prepare 1.5 internally with 25 cm thick perforated brick
and spread it over the farm. wall all around in mud or cement mortar to a
ii. The nutrient composition of the compost height of 0.9 m above ground. The above ground-
varies a great deal. It depends on the perforated structure facilitates passage of air for
materials used and the preparation methods. aerobic decomposition. The floor of the tank is
laid with bricks.
3.2.
TECHNOLOGY OPTIONS FOR
COMPOSTING OF ORGANIC WASTES The tank is covered on top with a thatched
roof. The ingredients for making compost are
There are following options of composting of agro-wastes, animal dung and soil in the ratio of
wastes 45:5:50 by weight. The ingredients are added in
layers starting with vegetable matter, followed by
1. NADEP Method
2. Bangalore method
3. Indore method
4. Vermi composting
5. Rotary drum composting
6. Biogas Technology

3.2.1. NADEP Method

The NADEP method of organic composting


was developed by a Gandhian follower namely
Narayan Deotao Pandharipande of Maharastra
Fig. 3.1 Source: Pandhariponde, 2008
(Pusad) (N.D. Pandharipande 2008). Compost

41
Solid and Liquid Waste Management in Rural Areas

dung and soil in that order. Each layer can be not disturbed for about 3 months, when organic
of about 45 kg vegetable matters, 5 kg of dung matters are almost completely degraded by the
mixed in 70 lts of water and 50 kg of soil so that help of different groups of micro organisms. About
30 layers will fill the tank. For Convenience, the 22-50 lts of water is to be sprinkled twice a week
number of layers could be reduced to half, this after the tank is fully loaded. After degradation,
number the quantities of ingredients in each layer. nutrients produced in the compost tank are
After 15-30 days of filling the organic biomass absorbed by the soil layers thus preventing their
in the tank gets automatically pressed down to 2 loss. In some compost methods such nutrients
ft. The tank is refilled by giving 2-3 layers over especially nitrogen is lost in soil.
it and is 9 resealed. After this filling, the tank is

Fig. 3.2 A NADEP Composting in a shade Fig. 3.3 A NADEP composting showing aeration
(Source: Pandhariponde, 2008) (Source: Pandhariponde, 2008)

One tank can be used three times in a year. With i. It is very simple to construct and easier to
production of 3 tons to 3.5 tons of compost operate.
produced per cycle, about 9 to 10 tons of compost
ii. In this method, compost can be prepared
can be made annually from one tank. The compost
with small quantity of cow dung (5Kg) and
can be stored for future use. It is advisable to
hence, it can be considered as appropriate
sprinkle cultures like Trichoderma, Azatobacter,
rural model.
whenever available to enhance the composting
process. It enhances nitrogen contents of manure. iii. Labour is required only for the construction
It is necessary that a farmer should have at least and one time filling of the tank and
2 tanks so that when one is filled up the other one excavation of manure. No labour is required
is available for loading the material generated in during composting period for churning of
the farm. wastes.

Advantages of NADEP iv. There is no loss of plant nutrients in


In addition to have organic manure for its compost. Therefore, percentage of nutrients
economical use and improvement of sanitation in in manure is high in comparison to other
villages, the NADEP method of composting has composting methods.
the following advantages:

42
Limitations with NADEP method animal dung are laid (CPHEEO 2000). The pit
i. Filling of tank is cumbersome during the method of making compost conserves moisture,
raining season, so it is useful in areas with low rainfall and a long
dry season. It should not be used in wet areas, as
ii. Expenditure on transport of soil is high the compost may become waterlogged.
when the unit is away from the field.
However, if the tanks are installed in the The pit is completely filled and a final soil layer
same field, where agro-wastes are generated is laid, to prevent fly breeding, entry of rain water
and manure to be used, this is not a limiting into the pit. The material is allowed to decompose
factor. for 4 to 6 months after which the stabilised material
is taken out and used as compost. The Bangalore
3.2.2. Bangalore Method method requires longer time for stabilisation of
the material & hence needs larger land space. The
Acharya (1939) had initiated the work of gases generated in this anaerobic process also
composting the town refuse and night soil. pose smell & odour problems.
This process is also called Hot Fermentation
Mechanism of composting or the Bangalore 3.2.3 Indore Method
method. The raw materials used are mixed plant
residues, animal dung and urine, earth, wood ash This process was developed by Howard and Wad
and water. All organic material wastes available in 1931 at Indore, Madhya Pradesh. In this method,
on a farm such as weeds, stalks, stems, fallen waste materials such as plant residues, animal
leaves, prunings, chaff, fodder leftovers and wastes, weeds, street refuse and other organic
so on, are collected and stacked in a pile. Hard wastes can be composted. The waste materials
woody material like cotton or pigeon pea stalks are cut into small pieces and spread in layers of
and stubble are first spread on the farm road and 10-15 cm thickness either in pits or in heaps of 1
crushed under vehicles such as tractors or bullock m wide, I m deep and of convenient length. It is
carts before being piled. Such hard materials properly moistened with cow dung using earth.
should in any case not exceed ten percent of the To ensure 50 % moisture sufficient water should
total plant residues. Green materials, which are be sprinkled for making the composting materials
soft and succulent, are allowed to wilt for two moist. Periodically, three to four turnings are
to three days to remove excess moisture before given. This method of composting in pits involves
stacking; they tend to pack closely if they are filling of alternate layers of similar thickness as
stacked in the fresh state. The mixture of different in Bangalore method. For starting the turning
kinds of organic material residues ensures a operation, the first turn is manually given using
more efficient decomposition. While stacking, long handled rakes, 4 to 7 days after filling. The
each type of material is spread in layers about 15 second turn is given after 5 to 10 more days. Third
centimeters thick until the heap is about one and a turn is also given after 5-10 days. Further turning
half meters high. is normally not required and the compost is ready
in 4-5 weeks. The Indore method stabilizes the
This is a pit method of composting where anaerobic material in shorter time and needs lesser land
condition is conventionally carried out in pits. space. As no odourous gases are generated in
Initially the waste is anaerobically stabilized in this process, it is environment friendly & hence
pits where alternate layers of organic wastes and commonly preferred. The composted material

43
Solid and Liquid Waste Management in Rural Areas

obtained by this method will contain 1.5 %


nitrogen, 1.0 % phosphorus and 1.5 % potassium.
Advantages and Limitations

The Indore process requires relatively high labour


requirement and inadequate protection from rain,
sun and wind. Loss of nutrients is rapid. Upper
portion of heap gradually dries as a result of poor
decomposition. However, this method can be
applied by a farmer easily. No much technical
inputs are required to complete the process.

3.2.4. Vermi composting


Fig 3.4
Vermi compost is a natural compost of organic
c) It enhances the decomposition of organic
wastes through Earthworms,( Fig. 3.4) who
matter in soil.
take up organic wastes and after degradation
and digestion, convert such wastes in the form d) It contains valuable vitamins, enzymes and
of granules, rich in nitrogen content. Such hormones like auxins, gibberellins etc.
vermin cast or vermin compost has good plant
nutrients and therefore compost. This is a natural
Nutrient content of vermin compost
composting method being used in India and other
Depending upon the types of substrate, contents
countries for centuries. However, in recent years
of plant nutrients vary with vermin compost.
there has been systematic methods developed
However, a typical vermicompost has the
to enhance such composting by using improved
following percentage of plant nutrients:
methods and strains of earthworms in rural as
well as urban areas in India also.
Nitrogen- 1.5 – 2.5 % Calcium- 0.5 – 1.0 %,
Phosphorus- 0.9 – 1.7 % Magnesium- 0.2 – 0.3 %
Advantages of vermicompost:
Potash- 1.5 – 2.4 % Sulphur- 0.4 - 0.5 %, and other
a. Vermi compost is rich in all essential plant micronutrients with enzymes and hormones.
nutrients.
b. Vermi compost is easy to apply, handle and Materials for preparation of Vermicompost:
Any type of biodegradable waste is suitable for
store and does not have bad odour.
vermicompost. Kitchen wastes, animal/ cow
c. It improves soil structure, texture, aeration, dung and leafy biomass are more suitable for
and water holding capacity. Vermi compost vermicompost.
contains earthworm cocoon and increases
the population and activity of earthworm in Efficient earthworm species:
the soil. The following species of earth worm commonly
found in India are used for vermicomposting:
a) Vermi compost is free from pathogens,
toxic elements, weed seeds etc. i. Eisenia foetida
ii. Amyanthes diffrigens
b) Vermi compost minimizes the incidence of
pest and diseases. iii. Eudrillus engineac

44
Methods of preparation of pit for vermicompost iv. Sprinkling of cow dung slurry to the heap
i. The vermicompost can be prepared in may be done.
concrete tank (Fig 3.5) or in soil pit lined v. A thin layer of half decomposed cow dung
with plastic sheet. (1-2 inches) should be placed at the bottom
ii. Inn household a cement ring can be used as of the pit.
pit for vermin composting. vi. Place the chopped weed biomass and
iii. The available bio-wastes should be collected partially decomposed cow dung layer wise
and are to be heaped for pretreatment for (10-20 cm) in the tank / pot up to the depth
4-5 days of 2 ½ ft. The bio waste and cow dung ratio
should be 60: 40 on dry wt. basis.

Fig. 3.5 vermicomposting in concrete ring


(Source: Nagavallemma et.al 2004) Fig. 3.7 Processed vermin compost (Source:
Nagavallemma et.al 2004)

i) Release about 2 kg earthworms per tonne of


biomass or 100 nos. earthworms per one sq.
ft. area.
ii) Place gunny bag on top of the cement ring
to maintain moisture content of compost
material.
iii) Sprinkling of water should be done to
maintain 70-80 % moisture content..
iv) Sprinkling of water should be stopped when
90 % bio-wastes are decomposed. Maturity
could be judged visually by observing
the formation of granular structure of the
Fig 3.6. Concrete ring cover with gunny bag compost at the surface of the tank.
(Source: Nagavallemma et.al 2004)

45
Solid and Liquid Waste Management in Rural Areas

v) Harvest the vermicompost by scrapping Once a day clockwise turning was carried out
layer wise from the top of the tank and heap manually by handle, which ensures proper mixing
under shed. This will help in separation of and aeration. Thereafter, aerobic condition was
earthworms from the compost. Sieving may maintained by opening half side doors. Two to
also be done to separate the earthworms and three rotations at a time were made to ensure
cocoons. that the material on the top portion moved to the
central portion, where it was subjected to higher
Advantages of using Bio-fertilizer temperature (Kalamdhad et al., 2008).
i. Can replace 20 to 50 % of chemical fertilizer
‘N’ and 15 – 25 % of phosphatic fertilizers.
ii. Bio-fertilizers being cheap, provide highly
cost effective supplement of chemical
fertilizers.
iii. Increase farm productivity, generally 10-40
% in grain yield and 15 – 30 % in vegetable
growth.
iv. Activates soil biologically thereby
increasing natural fertility of soil, which
causes sustainable agriculture.
v. Help in stimulating plant growth in general
and roots in particular as they serve various
growth promoting hormones like auxin,
gibberellins etc. They help in better nutrient Figure 3.8. Single Household Rotary Drum Composter
uptake and increase tolerance towards installed in IIT Roorkee (Source: Kalamdhad & Kazmi 2009)
drought and moisture stress. Methodology
The drum is operated for the following waste
3.2.5 Rotary drum composting combination:

A. For single household Uncooked vegetables waste, cow dung, tree leaves
A batch Rotary drum of 250 L capacity is used and sawdust were collected from various places
for batch composting of household organic waste and the mixture is shredded to 1 cm in order to
(Kalamdhad and Kazmi, 2008). The inner side of provide better aeration and moisture control.
the drum is covered with anti-corrosive coating.
The drum is mounted on four rubber rollers, Applicability
attached to metal stand and the drum is rotated The drum is applicable for rapid composting of
manually. In order to provide the appropriate kitchen and other organic waste generating from
mixing of wastes, 40mm long angles are welded a single household in all seasons without causing
longitudinally inside the drum. In addition, two any odour, vector, leachate in all seasons. Primary
adjacent holes are made on top of the drum to stabilized compost was achieved within 15-20
drain excess water (Fig 3.8). days.

46
B. For Community purpose ii. The composting can be conducted in all
Community scale continuous rotary drum seasons without causing any nuisance such
composter of 3.5 m3 capacity is used for high rate as odor, vectors, leachate etc.,
composting of 150-200 kg organic waste per day
(Figure 3.9). The drum has 3.5 m3 capacity and 3.2.6 Biogas Technology
3.7 m in length and 1.1 m in diameter, made up
of a 4 mm thick metal sheet was operated. 7.5 kW Quantum of energy utilised is regarded as socio-
motor with gear reducer is used to turn the drum economic status of any society. Due to lack
in clockwise direction at a speed of 2 rpm. of fuel, people in villages spend most of their
valuable time to collect fire woods for cooking.
In villages, most of the people use animal dung-
cakes for cooking purpose. Such animal dung
along with human wastes can be effectively used
for biogas generation through on-site biogas
plant linked with toilet. Biogas plant is important
in providing sustainable energy sources in
rural communities. Generation and utilization
of bioenergy has multiple advantages. It helps
improve sanitation, provide bioenergy at almost
nil recurring expenditure and finally slurry /
effluent of biogas plant has plant nutrient value
to be used for agriculture purposes. Thus toilet
Fig.3.9 A community rotary drum linked biogas plant has additional benefits in
(source Kalamdhad & Kazmi 2009) terms of improving sanitation. In villages where
household wastes contain mainly organics, they
In order to provide the appropriate mixing and are also suitable for biogas generation. Such
agitation, 400 mm long angles with 4 mm width wastes can also be mixed in the same biogas
and 150 mm height were welded longitudinally. plant to generate biogas production. In case of
A 2.5 kW air blower fixed at the inlet end was community toilets, biogas generation from human
used to suck the air from outlet end for aeration. waste is sustainable option (Jha, 2005).
It also promoted the escape of water vapours and
foul gases generated during composting. Two Biogas is a mixture of gas produced by
ports are provided at the middle and outlet zone of methanogenic bacteria while acting upon
drum to drain possible excess water and to collect biodegradable materials in an anaerobic condition.
compost samples. Biogas is mainly composed of 50 to 70 percent
methane, 30 to 40 percent carbon dioxide (CO2)
Applicability and low amount of other gases. Biogas is an
i. The rotary drum can be successfully applied odourless and colourless gas that burns with clear
in a small land area for rapid composting blue flame similar to that of LPG gas.
of all kind of organic waste (kitchen, cow
dung, dry leaves etc.,) generated from Quantity of biogas production from different
household, institutions, and dairies in rural feed materials
areas. i. From animal dung- per animal, per day,

47
Solid and Liquid Waste Management in Rural Areas

around 10 kg dung is produced. Gas In the KVIC model gas holder is made up of
production rate from dung is about 1.4 iron sheet (mild steel). During winter season
cft per kg, i.e., per animal per day, 14 cft
when temperature fall down to 10 degree Celsius
biogas is produced. or so, this model ceases to function as the iron
ii. From per person per day 0.3 kg of waste is sheet gas holder acts as good conductor of heat
generated that produces 1 cft of biogas. and inner temperature of the digester also attains
iii. A total amount of biogas of one cum can be the same temperature. Secondly, this gas holder
produced per day from a family having 4 requires regular care and maintenance to prevent
members and 2 cattle heads. from getting worn out because of corrosion. It has
short working life. Manufacturing of gas holder
requires sophisticated workshop facility that is
Utilizations of biogas
rarely found in rural areas. Therefore, in rural or
One cum of biogas per day can be utilized in a in urban areas the success rate of this model of
family as follows: biogas plant is far below the level of satisfaction.
a. Cooking of 3-4 family members for two
times a day Night Soil Digesters
b. Mantle lamps (2nos.) can be used for 6 The night soil can be anaerobically digested
hours per 24hrs. Such mantle lamps gives either alone or in combination with cattle dung. It
illumination equivalent to 4o watt bulb at is rich in nitrogen and phosphorus in comparison
220 volt of electricity. to cow dung. The characteristics of night soil are
different from the cow dung and are mentioned in
Manure value of sludge from biogas plant table below:
Besides biogas, the manure of the biogas plant
Characteristics of night-soil and cow-dung
has much plant nutrient value. It is directly
Table -3.2
used for agriculture purpose. The following is
the comparative value of plant nutrients (N,P,K,
value ) from biogas manure and other compost ( No. Characteristics Night soil Cow dung
Table 3.1). 1 Moisture 85-90 74-82
Table 3.1 content,%

2 Volatile solids as 80-88% 70-80


Sl. Name of Compost Biogas slurry % of total solid
No. constituent Manure (%) (%)
1. Nitrogen 0.50-0.75 1.30-1.50 3 Total Nitrogen as 3-5 1.4-1.8
N,% on dry basis
2. Phosphorus 0.70-0.80 0.85-0.92
3. Potash 1.20-1.50 1.50-1.65 4 Total Phosphorus 2.5-4.4 1.1-2.0
as P2O5, % on dry
basis
Design of biogas plant
5 Potassium as 0.7-1.9 0.8-1.2
For family size biogas plant there are basically K2O,% on dry
two designs (1) Floating drum type popularly basis
known as KVIC model and (2) Fixed dome type,
popularly known as Deenbandhu Model. Source: CPHEEO, 1993

48
Design Criteria Whereas, when plant is linked with toilet, only
The design criteria for night soil digester are listed 17-20 kg of cow dung is required for the same
in table below: quantity of biogas, depending on number of
Table 3.3 users of toilets in a family. Further percentage
of methane in toilet linked biogas plant is higher
No Items Magnitude (63.8%) over without toilet linked (60.4%). Such
1 Volumetric organic loading, Kg 1.6 toilet linked biogas plants have been implemented
VS/m3 d in many families in Navsari District ( Gujarat).
2 Hydraulic residence time , d 25-30 Families having such plants do not use LPG or any
3 Solid concentration of slurry 5 other fuel except. Produced biogas is sufficient to
fed to digester , % meet their cooking requirement.
4 Volatile solids destroyed during 45-55
digestion,%
5 Gas yield, m3 kg of VS added 0.5
in m3 / capita/d
6 m3 / capita/d 0.034

Source: CPHEEO, 1993

Deenbandhu model - This model is predominately


found in India. It is an underground fixed dome
digester made up of complete brick or RCC
structure (Fig. 3.10). It is a permanent structure
having almost nil operation and maintenance costs. Fig. 3.10 A section of family size biogas plant of
Deenbandhu Model (Source: Grassrootindia.com2013)
There is no separate gas holder, biogas is stored
inside plant through liquid displacement chamber.
This design is suitable also for generation of
biogas from human wastes along with cow dung
and kitchen wastes. There is almost no effect of
atmospheric variation of temperature on biogas
generation during winter season. It has several
advantages over the KVIC design. The following
section describes different aspects of Deenbandhu
biogas plant.

Toilet linked biogas plants fed with cow dung-


Cow dung biogas plant linked with toilet has
additional advantages. There is additive effect
on biogas production rate when cow dung based
biogas plant is linked with toilet. For one cum of
biogas production 25 kg of cow dung is required. Fig 3.11. A cow dung based biogas plant linked with toilet

49
Solid and Liquid Waste Management in Rural Areas

Materials required for biogas plant


The biogas plant can be set up with Bricks,
Cement, Stone chips of 1/2" Coarse Sand, G.I.
pipe 3/4" dia. sockets, 30 cm,, A.C./ PVC pipe 6"
dia, Iron bars (6mm dia) for outlet tank cover, Paint
(gas leak proof dibhapoxy), labour for digging
pit, labour for construction, skilled masons, BG
Stove, 10 m pipe line, lamp, accessories.

Components of a biogas plant:


Foundation
The foundation of the plant is bowl shaped with a
collar around the circumference. The construction
of the digester dome is based on this collar. Dome
is divided in 2 parts, Digester & Gas storage.
Digester: The bottom part is called the digester,
where the mixture of dung and water passes
through inlet chamber and anaerobic digestion by
the help of different bacterial groups takes place
producing biogas. Retention time of digester is
kept normally as 40 days.

Gas storage: gas produced by the bacterial activity


Fig 3.12 Drawing of a 4 cum biogas plant – is stored in the upper part of the digester dome
Deenbandhu Model called gas storage. Capacity of the gas storage
is designed for 50 % of the daily gas production
Selection of site capacity of the plant. However, as per requirement,
Site of biogas plant should be selected properly, gas storage capacity can be increased, depending
it should not be water logged and soil should on use of biogas.
be hard (high bearing capacity). It should
not be constructed in a shaded area. Sunlight Gas outlet pipe:
helps increase digester temperature therefore, A nipple is fitted on the top of the dome, which is
production of biogas. Biogas plant should be as connected to a GI pipe of ½ inch. The gas reaches
near to its use points- cooking and mantle lamps the kitchen through this pipe.
lighting. Longer the distance between biogas
plant and its use will reduce gas pressure in gas Inlet chamber:
pipe and hence will create problem. Inlet is the point where cow dung is mixed with
water before it passes to biogas plant through inlet
Selecting a biogas plant size: pipe connected with chamber.
A biogas plant of specific capacity can be selected
based on the daily availability of cattle dung, Outlet chamber
users of toilet (in case of toilet linked) and water Outlet chamber or liquid displacement chamber
requirements. has two functions- it allows passage of effluent

50
from the biogas plant and it determines the storage Testing the digester;
capacity of biogas plant. The digester of the Deenbandhu plant on
completion is tested before commissioning
Factors affecting biogas generation through smoke test for detecting gas leakages.
Temperature Smoke producing material is burnt inside the
For optimum biogas production, a temperature of digester and thereafter all vents of the digester are
35- 370C is optimum. At lower temperatures gas closed and checked for leakage. Any section of
production rate decreases. In winter season when the dome emitting smoke is identified and can be
temperature falls to 100 C or so, gas production sealed.
almost ceases. However, in case of underground
fixed dome digester like that of Deenbandhu Hydraulic testing for water leakages is done by
model, there is least affect on biogas production filling half of the digester with water and marking
due to atmospheric temperature difference. This the level. Thereafter, after a period of 6 to 7 days,
is due to the fact that digester dome is covered the water level is rechecked. In case of leakages
with soil that acts as insulator. It has least impact the water level will go down.
on inside temperature.
Starting a digester with feed material;
pH Initial digestion process with cattle dung feed
The pH range suitable for biogas production is should start within few weeks depending upon
rather narrow i.e. between 6.6 to 7.5. A pH value the temperature. If available, effluent (5-10%)
below 6.2 (acidic slurry) and above 8.0 (alkaline from a running biogas plant should be added to
slurry) becomes toxic to the bacteria. new biogas plant once at the start as an inoculums.
Cow dung itself contains a lot of mathanogenic
Total solid concentration in feed material bacteria, therefore, in case of unavailability of
Total solid in feed material is an important aspect. working biogas plant and its effluent, biogas
Around 8% TS is optimum for biogas production. production will continue.
In case of cow dung, this concentration is achieved
after mixing cow dung with water in the ratio of Uses of biogas for cooking
1:1, i.e., 10 kg of cow dung is mixed with 10 lit. Common uses of biogas are for cooking and
of water. lighting through mantle lamps. Biogas cooking

Fig 3.13, Use of biogas for cooking purpose in a rural family fitted with gas flow meters.

51
Solid and Liquid Waste Management in Rural Areas

burners are available in markets (Fig. 3.13). A Do's and Don’ts while operating a biogas plant
cooking burner consumes 8-24 cft of biogas Do's
per hour depending on its size. Biogas burns
in blue flame without any shoot or odour like i. Select the size of the biogas plant depending
LPG. It contains around 1 % hydrogen sulphide on the quantity of dung available with the
that has pungent odour, but for cooking during beneficiaries.
burning there is no such odour at all such odour ii. Install the biogas plant at a place near the
is useful to detect any leakage of biogas due to kitchen as well as the cattle shed as far as
loose connection of pipe etc. In rural areas where possible.
people are mostly dependant on fire wood or dung
iii. Ensure that the outer side of the plant is
cake for cooking purpose, biogas is a boon in
firmly compacted with soil.
improving health, environment and is economical.
iv. Ensure that the plant is installed in an open
Use of biogas for lighting space, and gets plenty of sunlight for the
Lighting through mantle lamp is another common whole day, all round the year.
use of biogas (Fig 3.14). Such mantle lamps are v. Feed the biogas plant with cattle dung and
available in markets. A Mantle lamp consumes water mixture in the right proportion-add
2-3 cft of biogas per hour. It gives illumination
1 part of cattle dung to 1 part of water by
equivalent to 40 watt bulb at 220 volt of
weight to make a homogeneous mixture.
electricity. In rural areas in most of the families
student can’t study in night due to unavailability vi. Ensure that the slurry (mixture of dung and
of electric supply and high cost of kerosene oil, water) is free from soil, straw, etc.
biogas is a sustainable option and boon for such vii. For efficient cooking, use good quality and
communities approved burners and gas lamps.
viii. Open the gas regulator cock only at the time
of its actual use.
ix. Adjust the flame by turning the air regulator
till a blue flame is obtained, this will give
maximum heat.
x. Light the match first before opening the gas
cock.
xi. Cover the top of the inlet and outlet tank
opening with wooden, stone or RCC cover,
to avoid accidental falling of cattle and
children.

Don’t do
i. Don’t install a bigger size of biogas plant
if sufficient cattle dung or any other feed-
Fig. 3.14 Biogas being used as lighting through mantle lamp stock to be used for biogas production is
not available.

52
ii. Don’t install the gas plant at a long distance vii. Don’t allow soil or sand to enter into the
from the point of gas utilisation to save the digester.
cost of pipeline and loss of biogas. viii. Don’t use the gas if the flame is yellow.
iii. Don’t install the plant under a tree, inside Adjust the flame by the air regulator till it is
the house or under shade. blue in colour.

iv. Don’t add more than required quantity of ix. Don’t use the gas after initial loading of
either dung or water-doing so might affect slurry, as it may take 15- 25 days for gas
production in freshly loaded plants. No
the efficient production of gas.
foreign material should be added.
v. Don’t leave the gas regulator (valve) open
x. Don’t let any water accumulate in the gas
when the gas is not in use.
pipeline; otherwise the required pressure of
vi. Don’t inhale the biogas as it may be gas will not be maintained and the flame
hazardous. will not be proper.

53
Solid and Liquid Waste Management in Rural Areas

REFERENCES:

yy Adhikari,S , I. Ghosh , S.P. Rai & S. solid waste management –Ministry of


Ayyappan ( 2009). Metal concentration in Urban Development. Government of India.
water, sediment and fish from sewage –
yy Dinges, R. 1982. Natural systems for water
fed aquaculture ponds of Kolkata, India,
pollution control. Van Nostrand Reinhold.
Environ Monit. Assess 159; 217-230
New York
yy Ajay S. Kalamdhad and A. A. Kazmi (2009)
yy Jhsphopen Courseware, Johns Hopkins
Rotary Drum composting of different
Bloomberg School of Public Health, 2013)
organic waste mixtures. Waste Management
website: www.ocw.jhsph.edu, assessed on
& Research. , v 27, n 2, p 129-137,
10.9.2013.
yy CPCB, (1986), Standard of Discharge of
yy Hoffmann, H.; Platzer, C.; Winker, M.;
Sewage, The Environment (Protection)
Muench, E., v.; GTZ (Editor) (2011):
Rules, Ministry of Environment and
Technology Review of Constructed
Forests, Government of India, 1986
Wetlands. Subsurface Flow Constructed
yy CPCB (2001), Guidelines for duckweed Wetlands for Greywater and Domestic
based wastewater treatment system, Wastewater Treatment. Eschborn:
Government of India. Deutsche Gesellschaft für Technische
Zusammenarbeit GmbH (GTZ) Sustainable
yy CPCB (2008). Report on decentralized
sanitation - ecosan program. URL
treatment & recycling of domestic waste
[Accessed: 14.11.2011]. PDF
water – an integrated approach to water
management at Sangamam community- A yy IS 2470 : Part 2 : 1985 Code of practice
village model in out-skirts of Auroville, for installation of septic tanks: Part II
Tamil Nadu. Secondary treatment and disposal of septic
tank effluent
yy Duncan Mara (1997), Design Manual for
Waste Stabilization Ponds in India, first yy Jha, P.K.(2005), "Recycling and reuse of
published in 1997 by Lagoon Technology human excreta from public toilets through
International Ltd., Newton House, Newton biogas generation to improve sanitation,
Road, Leeds LS7 4DN, England. community health, and environment"
International Seminar, organized by the
yy CPHEEO (1993). Manual on Sewage and
Asian and Pacific Centre for Agricultural
Sewage Treatment. Ministry of Urban
Engineering and Machinery (APCAEM)
Development, Government of India, Delhi
and Department of Science, Technology
yy CPHEEO ( 2013). Manual on Sewage and Education of Ministry of Agriculture,
and Sewage Treatment. Ministry of Urban Government of People’s Republic of China,
Development, Government of India, Delhi at Beijing, China.

yy CPHEEO, (2000), Manual on municipal yy Jha. P.K. (2010) Presented a paper on


“Sustainable technical options for effective

54
decentralized waste water treatment KL. 2004, ICRISAT, Vermicomposting:
system”, at the International Conference Recycling Wastes into Valuable Organic
on Decentralized Wastewater Treatment Fertilizer
Solution in Developing Countries,
yy Pandharipande, N.D. ( 2008): NADEP
organized by BORDA and IWA at Surabaya,
method of compost manufacture
Indonesia.
yy PRISM Bangladesh. May 1990. Shobuj
yy Kazmi A.A (2003), On site wastewater
Shona Progress Report 3.
treatment in Japan-An overview. Journal
of Institution of Engineers, (India). Vol. 83, yy Richard J. Otis and D. Duncan Mara, (1985).
March 2003, pp.41-45. The Design of Small Bore Sewer Systems,
TAG Technical Note No. 14 World Bank,
yy Kazmi et al. (2013). Documentation of
Washington, DC.
wastewater treatment plants in India.
Document produced within the project yy Robert, A. (1991); Constructed wetland for
Saraswati under the EU-India cooperation treatment of wastewater, Applied wetlands
on water technologies. science and Technology, Lewis Publishers.
yy Krishnan, S. B., and J. E. Smith (1987). yy Sascha Iqbal, (1999). Duckweed
Public health issues of aquatic systems Aquaculture, Potentials, Possibilities and
used for wastewater treatment. In Aquatic Limitations, for Combined Wastewater
plants for water treatment and resource Treatment and, Animal Feed Production in
recovery, Reddy, K. R., and W. H. Smith Developing Countries, EAWAG, SANDEC
eds. Magnolia, Orlando, FL. pp. 855-878 Report No. 6/99.
yy Landolt, E., and R. Kandeler. 1987. The yy Sasse, L. (1998), Book on Decentralised
family of Lemnaceae - A monographic study: Wastewater Treatment in Developing
Phytochemistry, Physiology, Application, Countries, Bremen Overseas Research
and bibliography. In Biosystematic and Development Association publication,
Investigations in the Family of Duckweeds Bremen, Germany.
(Lemnaceae). Veroeffentlichungen des
Geobotanischen Institutes der ETH, Stiftung yy Sonavane PG, et.al. (2008). Nutrient
Ruebel, Zuerich. Vol. 4, No. 95: pp. 638. removal by root zone treatment systems: a
review. J Environ Sci Eng. Jul; 50(3):241-8
yy Morel, A.; Diener, S. (2006): Greywater
Management in Low and Middle-Income yy Starkl M, Amerasinghe, P, Essl,l,
Countries, Review of different treatment Jampani,M, Kumar D, & Asolekar, S.R.
systems for households or neighbourhoods. (2013). Potential of natural treatment
Duebendorf: Swiss Federal Institute of technologies for wastewater management
Aquatic Science (EAWAG), Department in India. Journal for Water, Sanitation and
of Water and Sanitation in Developing Health for Development. In press.
Countries (SANDEC) yy Taylor Catherine, Don Jones, Joe Yahner,
yy Nagavallemma KP, Nagavallemma KP, Michael ogden and Alan Dunn, (1998);
Wani SP, Stephane Lacroix, Padmaja VV, Individual Residence Wastewater Wetland
Vineela C, Babu Rao M and Sahrawat Construction in Indiana, Agronomy and

55
Solid and Liquid Waste Management in Rural Areas

Agricultural and Biological Engineering, yy US EPA (2000) Wastewater Technology


Purdue University Fact Sheet Package Plants, EPA 832-F-00-
016
yy Tilley, E.; Luethi, C, Morel, A, Zurbruegg,
C, Schertenleib, R (2008): Compendium yy Vipat, V. (2003); Treatment of domestic
of Sanitation Systems and Technologies. wastewater through root zone Constructed
Duebendorf and Geneva: Swiss Federal wetland technology, Paryavaran Today, 17-
Institute of Aquatic Science and Technology 18, 4, 1-9.
(EAWAG). URL [Accessed: 15.02.2010].
PDF

Feedbacks, Suggestions may be sent to G. Balasubramanian, Deputy Adviser (PHE), Swachh Bharat Mission (Gramin),
Government of India, Ministry of Drinking Water and Sanitation, 12th Floor, Paryavaran Bhavan, CGO Complex, Lodi
Road, New Delhi - 110003. Email: [email protected], [email protected] Ministry's Website: www.mdws.gov.in

56
Design & Printed at Viba Press Pvt. Ltd. - 9810049515

For any further information contact:

Ministry of Drinking Water and Sanitation


Government of India
4th Floor, Paryavaran Bhawan, CGO Complex
Lodhi Road, New Delhi-110003
Phone: 011-24362705; Fax: 011-24361062
E-mail: [email protected]
Website: www.mdws.nic.in

You might also like