Autodesk Revit Best Practices #2:: Shawn Zirbes, Cad Technology Center (CTC), Minneapolis, MN
Autodesk Revit Best Practices #2:: Shawn Zirbes, Cad Technology Center (CTC), Minneapolis, MN
`
Brick Office Building – Steel and CMU Structural Systems
`
Brick Office Building – Steel and CMU Structural Systems
`
Brick Office Building – Steel and CMU Structural Systems
`
Brick Office Building – Steel and CMU Structural Systems
Structure model
`
Brick Office Building – Steel and CMU Structural Systems
Exterior Wall Type – Brick with CMU Backup & Brick with Metal Stud Backup – LOD 300
For LOD 300 model exterior walls have been developed as 2 wall types, one wall type for structure layer & one wall type for all remaining layers other than
structure.
`
Exterior brick veneer wall type remains common for both backup systems and has all layers in one single wall family.
CMU backup wall LOD 300 Metal Stud backup wall LOD 300
Brick Office Building – Steel and CMU Structural Systems
Vertically Grouted
& Reinforced Cells Drainage
Panel
Wall Ties
Brick Veneer
CMU Wall is placed in Structural Model and remaining wall layers are
CMU grouted cells placed at new scope area for LOD 350 modeling modeled as individual wall types in architectural model
Brick Office Building – Steel and CMU Structural Systems
Exterior Wall Type – Brick with Metal Stud Backup – LOD 350
Sheathing
Air Barrier
Gypsum
Board
Cold Form Rigid Insulation
Metal Framing
Masonry
Brick wall
Wall Ties
Metal Studs placed at new scope area for LOD 350 modeling All wall layers are modeled as individual wall types in architectural model
Brick Office Building – Steel and CMU Structural Systems
Brick Tie
Sectional View Brick Tie placement between Brick Veneer and CMU Backup
Brick Office Building – Steel and CMU Structural Systems
Base Detail Drafting View – Brick with CMU Backup – LOD 350 Wall Ties
Vertically grouted reinforced cells
Brick Veneer
CMU Back-Up
Insulation
Drainage
Material
Weeps
Concrete Wall
Window Sill Detail Drafting View – Brick with CMU Backup – LOD 350
Thermally Broke
Aluminum Window
Frame
Brick Veneer
Flashing Member
Sill
Head Detail Drafting View – Brick with CMU Backup – LOD 350 Adjustable Dovetail
Anchors
Weeps
Drainage
Material
Steel Lintel
Wood Nailer
Sectional View of Lintel 3D View of Lintel
Brick Office Building – Steel and CMU Structural Systems
Coping Detail Drafting View – Brick with CMU Backup – LOD 350
Strap Anchors with
Wood Blocking
PCC Coping
Metal Counter
Flashing
Insulation with
` voids for wood
blocking
Insulation layer Flashing over base insulation Coping Stone over the flashing 3D View of Coping
Brick Office Building – Steel and CMU Structural Systems
Base Detail Drafting View – Brick with Metal Stud Backup – LOD 350
Drainage
Material
Rigid
Insulation
Plan View
`
Sectional View of Base
Flashing with Brick ties on Stud Wall Air Barrier and Drainage Material Weeps and Brick Veneer
Brick Office Building – Steel and CMU Structural Systems
Window Sill Detail Drafting View – Brick with Metal Stud Backup – LOD 400 Window Frame
Flashing Member
Brick Veneer
Brick Tie
`
3D View
Sectional View of Window Sill
L-Angle support Brick Sill on Metal Flashing Slope Brick Sill Window Sill
Brick Office Building – Steel and CMU Structural Systems
Lintel Detail Drafting View – Brick with Metal Stud Backup – LOD 350 Drainage
Material Brick Veneer
Brick Ties
Weeps
Receptor
Framing
Steel Lintel
Weeps and Brick ties are placed aligned to the course mortar 3D View of Lintel
Brick Office Building – Steel and CMU Structural Systems
Coping Detail Drafting View – Brick with Metal Stud Backup – LOD 350
Metal Sheet
Coping
Wood Nailer
` Brick Veneer
Roof
Movement Joint– Brick with CMU Backup & Brick with Metal Stud Backup – LOD 350
Preformed
Gasket Silicon Sealant with
Backer Rod
Movement Joint in Metal Stud backup Wall Movement Joint in CMU backup Wall
`
Neoprene Pad
Silicon
Sealant Backer Rod
3D View 3D View
Brick Office Building – Steel and CMU Structural Systems
Worksets
In the present model, with most of the detail at LOD 300 & LOD 350, two worksets are As a sample case scenario; in case the entire model is created at
sufficient enough to accommodate all elements of the model. LOD 350, we can further subdivide the worksets to allot to each
element category as shown below:
Exterior Shell Model LOD 350 Model
Revit Link_Stru
Revit Link_Mech
Revit Link_Arch-Int
CMU Walls
` Stud Walls
Insulation Walls
Veneer Walls
“Thank You :
Shawn Zirbes, Cad Technology Center (CTC), Minneapolis, MN”