Coriolis Flowmeter Calculation Summary: Condensate Tank - CMFS040M - FCS
Coriolis Flowmeter Calculation Summary: Condensate Tank - CMFS040M - FCS
Date: 2020-11-23
Company: -
Project Name: -
Service: liquid
Sensor Model Name : CMFS040M
Sensor Model #: -
Sensor Tag(s): 32011
Transmitter Model Name : -
Transmitter Model #: -
Transmitter Tag(s): FT-32011
Wetted Material: 316L
Fluid: N-HEXANE
Fluid State: Liquid
K(Flow Consistency Index) -
n(Flow Behavior) -
Mass Flow Accuracy at Operating Flow (+/- % of Rate) 0.10
Pressure Drop at Operating Flow 45.43 psig
Velocity at Operating Flow 19.99 m/sec
Min Operating* Max Design Units
Flow Rate: - 130.00 - - m3/day
Pressure: - 550.00 - - psig
Process Fluid Temperature: - 40.00 - - C
Ambient Temperature: - 30.00 - - C
Density: - 5.36 - 0.00 lb/Gallon(US)
Viscosity: - 0.26 - - cP
-
Base Reference Temperature: C
0.12 54
Pressure Drop (psig)
0.10 45
Flow Accuracy
0.08 36
Flow Accuracy
0.06 27
Pressure Drop
0.04 18
0.02 9
0.00 0
1.7324
6.8631
11.9938
17.1245
22.2552
27.3859
32.5166
37.6473
42.7780
47.9087
53.0394
58.1701
63.3008
68.4315
73.5623
78.6930
83.8237
88.9544
94.0851
99.2158
104.3465
109.4772
114.6079
119.7386
124.8693
130.0000
* All pressure drop and velocity results are based on the process conditions (except flow rate) that are entered in the Operating column.