Common Utility Grid Transformers in 60 HZ in North America, Central America, and The Caribbean. Please Verify With Appropriate Installation Manual

This document provides information on common utility grid configurations in North America, Central America, and the Caribbean operating at 60 Hz. It lists the voltage configurations for various types of utility grids including 240V delta corner ground, 208V delta corner ground, 240V delta, 208V delta, 208V WYE, 240V stinger ground, 480V delta, 480V WYE, 240V split-phase and the compatible inverter models for each configuration. An legend is also provided to identify the components in the diagrams.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views1 page

Common Utility Grid Transformers in 60 HZ in North America, Central America, and The Caribbean. Please Verify With Appropriate Installation Manual

This document provides information on common utility grid configurations in North America, Central America, and the Caribbean operating at 60 Hz. It lists the voltage configurations for various types of utility grids including 240V delta corner ground, 208V delta corner ground, 240V delta, 208V delta, 208V WYE, 240V stinger ground, 480V delta, 480V WYE, 240V split-phase and the compatible inverter models for each configuration. An legend is also provided to identify the components in the diagrams.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

INVERTERS & UTILITY GRID CONFIGURATION

Common Utility Grid Transformers in 60 Hz in North America, Central America, and the Caribbean. Please verify with appropriate installation manual.

240 V Delta Corner Ground 208 V Delta Corner Ground 240 V Delta 208 V Delta 208 V WYE

1 a) 1 b) L-L a) L-L b) L-L


SB 3.0-US SB 3.0-US SB 3.0-US SB 3.0-US SB 3.0-US
SB 3.8-US SB 3.8-US SB 3.8-US SB 3.8-US SB 3.8-US
SB 5.0-US SB 5.0-US SB 5.0-US SB 5.0-US SB 5.0-US
SB 6.0-US SB 6.0-US SB 6.0-US SB 6.0-US SB 6.0-US
SB 7.0-US SB 7.0-US SB 7.0-US SB 7.0-US SB 7.0-US
SB 7.7-US SB 7.7-US SB 7.7-US SB 7.7-US SB 7.7-US

L-N
SI 4548-US - 120 V
SI 6048-US - 120 V
240 V Stinger Ground 480 V Delta 480 V WYE 240 V Split-Phase

L-L
SB 3.0-US
SB 3.8-US LEGEND
SB 5.0-US Line 1 Line 2

SB 6.0-US Neutral
L-L c) 3ɸ 3ɸ SB 7.0-US
SB 3.0-US STP 30000TL-US STP 12000TL-US SB 7.7-US SB Sunny Boy
SB 3.8-US STP 15000TL-US SBS 3.8-US
SBS
STP
Sunny Boy Storage
Sunny Tripower

COMMONGRIDCONFIG-AUS184628
SB 5.0-US STP 20000TL-US SBS 5.0-US SI Sunny Island
SB 6.0-US STP 24000TL-US SBS 6.0-US
L-L
L-N
Line to Line
Line to Neutral
SB 7.0-US STP 30000TL-US 3ɸ 3 Phase

SB 7.7-US STP 33-US L-N


Line 3

STP 50-US SI 4548-US


L-N STP 62-US SI 6048-US
SI 4548-US - 120 V
SI 6048-US - 120 V

a) 240 V country standard must be selected during commissioning SMA America, LLC
b) 208 V country standard must be selected during commissioning www.SMA-America.com
c) For 2 and 3, 240 V country standard must be selected during commissioning