12 MCM3320 Hardware IO Block Diagram

The document provides an overview of the hardware inputs, outputs, and interfaces of a power control module. It includes bidirectional power inputs, communication ports, discrete and analog inputs and outputs, and breaker interfaces to control generators and utility sources. Relay outputs are used to start generator sets and control load demand.

Uploaded by

Juan Carlos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
301 views1 page

12 MCM3320 Hardware IO Block Diagram

The document provides an overview of the hardware inputs, outputs, and interfaces of a power control module. It includes bidirectional power inputs, communication ports, discrete and analog inputs and outputs, and breaker interfaces to control generators and utility sources. Relay outputs are used to start generator sets and control load demand.

Uploaded by

Juan Carlos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

B+ Input1 Master Freq Bias

B+ Input2 Master Volt Bias


B+ POWER BIDIRECTIONAL
Gnd Master Priority
Gnd
RELAY OUTPUTS Start Gensets Relay

CAN (Master)
RS485 PCCNet COMMUNICATIONS
RS485/232 Mon/MB
Load Govern Enable
Load Demand Gen1
Extended Para Start Load Demand Gen2
Sync Enable DISCRETE Load Demand Gen3
OUTPUTS Load Demand Gen4
Utility Source Failure
DISCRETE (low side drivers)
Cfg Out1 (com warn)
INPUTS
Transfer Inhibit (active low w/ Cfg Out2 (fail to sync)
pullup) Cfg Out3 (gen avail)
Retransfer Inhibit
Gen CB Tripped Cfg Out4 (util avail)
Util CB Tripped Cfg Out5 (fail to discon)
Gen CB Inhibit Cfg Out6 (sync’d)
Util CB Inhibit MCM3320 Hardware I/O Cfg Out7
Manual Cfg Out8

Paralleling Gensets
Test Start Breaker Inhibit
Fault Ack/Reset
Gen1 Available
Gen2 Available Relay Supply
B+ OUTPUTS
Gen3 Available
Gen4 Available
Override
ANALOG
OUTPUTS
kW Load Setpoint BREAKER kW Master Load Control
ANALOG
kVAR Load Setpoint INPUTS INTERFACE
kVAR Master Load Control
(0-5V) (discrete inputs /
relay outputs)
GEN BUS/UTIL
V/I V/I
Gen Position B
Gen PositionA

Util Position B
Util PositionA
Gen Close
Gen Open

Util Close
Util Open

Gen Utility

P. Dahlen
9/8/05 Load