02 - SIM DN150 PN160 Valve 2 PDF
02 - SIM DN150 PN160 Valve 2 PDF
02 - SIM DN150 PN160 Valve 2 PDF
Valve DN 150
Valve PN 160
Insert type Customized
orifice unit Needed
All used heads are considered to be dynamic ones. We kindly encourage the hydraulic designers to check the correctness of the
used data and comment or confirm them. If heads measured on site differ from those simulated the performance of the valve will
be affected. Maximum flow may not be achieved, cavitation may be encountered.
This solution adopts an orifice system downstream of the valve. The orifice system builds up pressure to create
favorable conditions for the control valve. P2 indicated in this simulation resembles the backpressure created by the
orifice unit. The downstream pressure of the orifice unit (P3) is the pressure available in the system. and te one
provided in your data sheet.
In this case of high flow P3 = 0,16 bar
]
This chart is only valid for cavitation free operation.
Zeta curve
10000000
100
1000000
100000
10000
Zeta
1000
100
10
1
0 10 20 30 40 50 60 70 80 90 100
Opening degree [%]
v2
Dp z r
2
Dp ... head loss [Pa] (10 5 Pa = 1 bar)
z ... head loss coefficient (without dimensions)
r ... density of liquid [kg/m³]
v ... average flow velocity [m/s]
(referred to the valve size)
Name KM Zeichnungsnummer
Meßfile
Jabal Hafeet Valve 2
]
This chart is only valid for cavitation free operation.
Kv curve
35 553
30
25
kv value [m³/h]
20
15
10
0
0 10 20 30 40 50 60 70 80 90 100
Opening degree [%]
Dp
Q kv
10 r g
Name KM Zeichnungsnummer
Meßfile
Jabal Hafeet Valve 2
]
This chart is only valid for cavitation free operation.
1,00
0,10
Sigma values
0,01
0,00
0 10 20 30 40 50 60 70 80 90 100
Name KM Zeichnungsnummer
Meßfile
Jabal Hafeet Valve 2